Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹3.0 L+₹89,051.16 (43.0%)Accepted-Finance | L2 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
26 Mar 2020, 11:00 amClosed
EEEnMHPI
DELHI JAL BOARD GOVT OF NCT OF DELHI OFFICE OF THE EXECUTIVE ENGINEER EnM HP I HAIDERPUR WATER WORKS DELHI 110085
Supply and Fixing of Exhaust fans at CWPH HP 1. ReInvited
2020_DJB_189949_1
NIT 30
Open Tender
Miscellaneous Works
Works
60 days
haiderpur water works
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹4,600
28 Mar 2020
20 Mar 2020
26 Mar 2020
20 Mar 2020
26 Mar 2020
20 Mar 2020
Supply of new 18 Inch, (450 mm sweep) industrial type Exhaust Fan,Make Polar/Havells/Crompton
Supply of new 24 Inch, (600 mm sweep) industrial type Exhaust Fan Make Polar/Havells/ Crompton
Supply of new 12 Inch, (300 mm sweep) industrial type Exhaust Fan Make Polar/Havells/ Crompton
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Up to 450 mm sweep (DSR E&M 2018 -- 1.50.1)
For 450 mm sweep (DSR E&M 2018 -- 1.50.1)
For 600 mm sweep
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 2018 -- 1.5)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (DSR E&M 2018 -- 1.7) A) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required (DSR E&M 2018 -- 1.7) A) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. (DSR E&M 2018 – 1.23) 6 Pin 15/16 amp. Socket
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (DSR E&M 2018 – 2.3) 16 Way Double Door
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2018 – 2.12) 63 Amp
Un-installation of Exhaust Fan from the existing slots
Maa Vaishno Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .