Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.1 Cr+₹5.7 L (5.27%)Rejected-Finance | ₹1.1 Cr+₹5.7 L (5.27%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹1.2 Cr+₹7.2 L (6.59%)Rejected-Finance | ₹1.2 Cr+₹7.2 L (6.59%) | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹1.2 Cr+₹10.3 L (9.50%)Rejected-Finance | ₹1.2 Cr+₹10.3 L (9.50%) | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹1.2 Cr+₹12.1 L (11.2%)Rejected-Finance | ₹1.2 Cr+₹12.1 L (11.2%) | L5 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹2.1 L
Closing Date
12 Jun 2021, 6:00 pmClosed
Commander Works Engineers AF South , Bangalore
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
SPECIAL REPAIRS TO BLDG NO.T-16,T-18, T-19 AND T-20 AT ATS BELAGAVI
2021_MES_435721_1
81173/E8
Open Tender
Civil Works
Item Rate
120 days
SAMBRA, BELGAUM
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
Yes
GE(AF) SAMBRA
₹2.1 L
Yes
2 Jul 2021
10 Apr 2021
14 Jun 2021
12 Apr 2021
12 Jun 2021
11 May 2021
12 Apr 2021 - 20 Apr 2021
Amount
Dismantling asbestos cement (Corrugated, semi corrugated, etc) sheets in roof coverings incl ridges complete all as directed.
Dismantling timber scantlings 40sqcm and over in section in any position unframed work complete all as directed.
Dismantling of wrought iron or mild steel work of any description like wind ties / purlins and rafters complete all as directed.
Dismantling framed trusses span not exc 10m complete all as directed.
Erection and fixing of rolled section as in main and cross beams, hip and jack rafters, purlinS taken out from dismantling, where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe -290(Gde E-165) complete all as specified and as directed.
S&F rolled section as in main and cross beams, hip and jack rafters, purlinS where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates confirming to Fe -290 (Gde E-165) complete all as specified and as directed.
S & F Steel work in Tubular Roof trusses (framed), trussed welded with purlins, crane gantries, rails and fastenings and heavy bracket framing ,including distance pieces, cleats etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and as directed.
S & F MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment confirming to Fe -410-W (Gde E-250) quality-A complete all as specified and as directed.
S&F Mild stell rag or lewis bolts with Dia of neck 20mm, screwed one end, with hexagonal or square nuts and washers, the other end enlarged and jagged or lewised, exc 30cm long all as specified and directed
M & L pre painted galvalume alumium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. (Note :- The length of self tapping screw may vary for wooden and steel truss. Contractor to quote rate accordingly.)
M & L pre painted galvalume alumium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in rideges, roof overing/cladding to wall, fixed with self tapping screws complete all as specified and as directed. Note :- The length of self tapping screw may vary for wooden and steel truss. Contractor to quote rate accordingly.
S&F MS flat as in wind ties for roofing incl securing bolts confirming to Fe -290 Gde E-165 complete all as specified and as directed.
Dismantling wall and ceiling boards (Fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets, frame work all as directed.
Material and labour for providing aluminium snap grid frame work supported by hanger 6mm dia GI (up to length as per site requirement) for false ceiling, adjusting level fixed to roof slabs/ walls/wooden members by means of ceiling cleats made out of GI flat 40x3 mm size 60 cm long and expansion hold fasteners 12.5mm dia 40mm long complete all as specified for false ceiling fixed with screws as per manufactures instructions
S&F for 12mm thick perforated particle board/tiles for insulation and accoustic purposes, 60x60cm in size, fixed in ceiling with screws, flat or sloping complete all as specified and directed
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided as directed.
Material and labour cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges all as specified and directed.
Material and labour cement concrete type B1, 1:2:4 (20 mm graded aggregate) with necessary formwork as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like includingweathering, slightly rounded or chamfered angles and throating, all as directed
M & L Cement concrete type B0, 1:2:4 (12.5 mm graded stone aggregate) 25 mm thick as subbase of flooring all as specified
M&L Machine cut kota stone slab flooring 20-25 mm thick over and including cement screed base of 20 mm thick in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade including rubbing and polishing complete all as specified and as directed.
All as per item No 20 above but but 15-18 mm thick kota stone in skirting on vertical surface over 10 mm thick rendering surface finished even and fair to receive stone in cement mortar 1:4 complete all as specified and as directed.
M & L Cement concrete type B1, 1:2:4 (20mm graded stone aggregate) 75 mm thick as in plinth protection complete all as specified & directed
M & L Cement concrete type B1 1:2:4 (20mm graded stone aggregate) 100 mm thick as in pavements complete all as specified & directed
Glass dividing strips, 3 mm thick and 22 mm wide inserted in position, conform to design as in plinth protection all as specified
Demolition of cement concrete (reinforced) of any description and in any position all as specified
Separating, scraping and cleaning of reinforcement all as directed.
Use & waste formwork to fair finished flat concrete surfaces of chullah hoods, chajjas, troughs and similar items in including edges complete all as specified and as directed.
M & L RCC (Nominal mix) Type B1, 1:2:4 (20mm graded aggregate) as in chajjas and the like all as specified and directed
TMT bars for reinforcement 10mm dia and over cut to length, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
All as per item No 29 above but 5mm and over upto and including 10mm dia TMT bars in stirrups, spacers and binders complete all as specified and as directed.
M&L for Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) and cured complete all as specified and directed.
M & L providing cement concrete type B0, 1:2:4 (12.5 mmm graded stone aggregate) as in padding concrete for roof all as specified and directed
M & L for applying 3 coats cement wash with protland cement slurry complete all as specified and directed
M & L rendering 10mm in CM 1:3, mixed with water proofing liquid 100 ML per bag of cement or as specified by manufacturer instruction on concrete surfaces of roof and making the surfaces finished fair and even as in required slope for draining out the rain water all as specified and directed. Note - Supply only WPC shall be measured and paid for separately
Material and labour for removal of exisitng WPT course or any other kind of treatment surfaces over roof slab and cleaning of surface with wire brushes removing of unsolvent materials and depositing of the same as directed at a distance not exceeding 50 m and applying of oil bound bituminous primer @ 0.20 Kg/sqm and providing 4 mm thick APP modified water proofing membrane weighing not less than 160 gms / sqm incl minimum 10 cm side over laps and 15 cm end lap torch sealed and bonded as per detailed procedure on note NO 6 of TD drawing NO AFB/TD/260/06 sheet No 1/1 (R) and applying a coat of blown grade @ 1.2 Kg/Sqm hot bitumen 90/15 on top of the memberane finished with solar pain/primer @0.1 Kg per sqm all as specified and as directed. Note : The work shall be carried out only through manufacturer or their authorised applicator and a written gurantee for work shall be submitted by the contractor.
Demolition of brickwork or stone/boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but all as specified.
M & L for pre cast cement concrete block masonry type C1, 1:3:6 (20 mm graded agrregate) solid blocks exc 10cm in width having minimum compressive strength of 50 kg/sq cm as per IS 2185 (Part I) 2005 and set in cement mortar (1:4) complete all as specified.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
Rendering 10 mm thick in CM 1:4 for fair faces of brickwork or concrete surfaces wall finished even & smooth without using extra cement all as specified and as directed.
Rendering 15 mm thick in CM 1:4 for fair faces of brickwork or concrete surfaces wall finished even & smooth without using extra cement all as specified and as directed.
Rendering 5 mm thick in CM 1:3 for fair faces of concrete surfaces ceiling finished even & smooth with without using extra cement all as specified and as directed.
S & F GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste all as directed
Raking out joints/ pointing to random rubble or polygonal masonry uncoursed or brought upto courses in cement mortor walls or to bricks on edges in wall surfaces, floors, roofs etc
Flush pointing to random rubble masonry uncoursed or brought upto coarses in cement mortor 1:3 all as specified and as directed.
M & L for preparation of new surfaces of walls and applying a thin layer of 3mm thick wall care putty (JK or Birla) and applying two coats of oil bound distemper all as specified and directed
M & L for complete removal of existing treatment of old surface of wall by scrapping wand washing including perpration of surface by applying a thin layer of 3mm thick wall care putty (JK or Birla) and applying two coats of oil bound distemper all as specified and directed
M&L for preparation of external new plasterd surfaces of walls by complete including washing, rubbing and cleaning and applying a coat of primer and two coats of antifungal paint all as specified.
M&L for preparation of external old plasterd surfaces of walls by complete removal of existing treatment including washing, rubbing and cleaning and applying a coat of primer and two coats of antifungal paint all as specified.
M &L preperation of new ceiling surfaces and applying three coats of white wash all as specified
M&L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified.
Taking down of chowkats with shutters (without taking off shutters from the frames) n exc 1.5 sqm each all as specified and directed.
Supply and fix steel windows with side hung shutters including projecting type hinges with guard bars, steel handles and steel peg stay complete with glazing bars devetailed or welded
S&F steel windows with side hung shutters including projecting type hinges with steel handles, and steel peg stay complete without glazing bars, dovetailed or welded complete all as specified and as directed.
Supply and fix steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and as directed.
Sheet glass, ordinary quality, in squares not exc 0.5 sqm each pane of 3 mm thickness with oil putty all as specified and directed
Figured glass 3 mm thick , pin head type and glazing with oil putty in square n. exc 0.5 sqm in each pane all as specified and directed
M/L for factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with ms square tube suppling and fixing in opening as per specification and drawing all as specified and directed
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frames made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specificattion & drawing all as specified and directed
Taking down of chowkats with shutters (without taking off shutters from the frames) exc 1.5 sqm and n exc 4 Sqm each all as specified and directed.
S & F Pressed steel frames of size 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete as specified
S & F 35 mm thick second class hardwood rail & style plain framed pannelled factory made shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I) kiln seasoned and chemically pressure treated all as specified and directed
M & L 2nd class hard woodglazed and skeleton shutters, 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, gauze etc; sizes of members of shutters as specified in SSR Part I, section 8, clause 8.24 (a) supplied and fitted to chowkats all as specified and directed
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or steel screws all as specified
M & L for preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer all as specified and directed.
M & L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified
M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified
S & F 140 mm overall length of cover plate floor door stopper of aluminum alloy body and tongue,anodised with hard drawn steel spring fixed in floor all as specified and directed
S&F 200 mm long aluminium anodised barrel tower bolt all as specified and directed
S&F 100 mm long aluminium anodised barrel tower bolt all as specified and directed
S&F 150 mm long extruded aluminium anodised handle fabricated type all as specified and directed
S & F for 300 mm long Aluminium alloy, anodised sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections all as specified and directed
Supply and fixed 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete in mild steel fixed to MS frame or wooden framed as specified
S&F extruded aluminium alloy with galvanised mild steel hinge pin, anodised 100 mm long butt hinges all as specified and directed
S & F in repairs Harrison curtain rails, anodised aluminium alloy with fixing brackets, stops, rollers etc all as specified and directed
Dismantling wall, floor, hearth tiling including cement mortar bedding (but not backing) and removing unserviceable material as directed.
Roughning surfaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust,etc. to receive the floor finishes all as directed and specified.
M & L for coloured Non skid (Joint free) tiles superior finish grade B-1 quality 7 to 8 mm thick(square/ rectangular) area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm in floor with rectified edges etc., set and jointed in neat cement slury over cement screed 15 mm thick 1:6 all as specified and directed
M & L for Coloured glazed ceramic tiles economy finish Gde B-II (b) quality of size 300 x 200 x 7mm/ 300x450x7mm thick with rectified edges as in vertical surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 cm thick backing with cm 1:4 all as specified and directed
Supply and fixing in repairs PVC water tanks of 500 Ltr capacity, triple layered, rotational moulded polyethylene water storage tank cylinderical vertical with same capacity with closed top hoisted and fixed in position all as specified in SSR part I including complete set of ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed of size 25 mm dia all as specified.
Taking down 20mm dia steel tubing and connection including bib taps, stop cock, showers etc. all as directed.
Taking down 25mm dia steel tubing and connection including bib taps, stop cock, showers etc. all as directed.
Taking down 40mm dia steel tubing and connection including bib taps, stop cock, showers etc. all as directed.
Taking down 50mm dia steel tubing and connection including bib taps, stop cock, showers etc. all as directed.
Supply and laying of CPVC pipes of 25 mm outer dia SDR 11 and plain CPVC SDR 11 fittings in wall / ceiling or laying in floors complete all as specified and directed Note :- All pipes inside the buildings should be concealed and disturbed on any type of surface be make good by the contractor in the quoted rates.
All as per item No 84 above by 20 mm outer dia all as specified and directed
S&F 15mm stop valves fancy type, chromium plated, screwed down, high pressure, with crutch or round handle screwed both ends for iron pipe or for unions and fixed as in repair all as specified and directed
Supply and fix for 25mm bore gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed including taking down unserviceable one complete all as specified and as directed.
Supply and fix for 50mm bore gun metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe fixed including taking down unserviceable one complete all as specified and as directed.
S&F 15mm bib taps fancy type chromium plated round handle, screwed down, screwed for iron pipe and fixed as in repair all as specified and directed
S & F 15mm pillar taps fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and flynuts screwed for iron pips and fixed as in repair all as specified and directed
S & F (Unions 20mm outer dia ) CPVC ll as specified and directed
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar of size 100 mm/ 75 mm ll as specified and directed
S&F in repairs 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed in wall/ floor with necessary clamping where required
All as per item No. 93 above but 110 mm bore pipe ll as specified and directed
S & F (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm dia inclduing fixing to existing pipe properly with solvent all as specified and directed
S & F PVC (SWR) bends for 75 mm bore pipe with access door ll as specified and directed
All as per item No. 96 above but for 110 mm bore pipe ll as specified and directed
S & F PVC (SWR) vent cowl 110 mm dia ll as specified and directed
Supply & Fixed in repairs vitreous china wash down water closet pan pedestal pattern white (excluding flushing cistern and flush pipe ) including all accessoreis ie., plastic seat black closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device ll as specified and directed
Supply & Fixed in repairs vitreous china white flat back wash hand basin size 450 x 300 mm including waste coupling of 32 mm dia PTMT (half or full threaded) and waste pipe fixed properly with fixing screws or bolts and make good the surface with white cement all as specified and directed.
S & F in repair PVC valve less syphonic action type low level flushing cistern 10 Ltr capacity including flange valve handle, Bracket, PVC flush down pipe length upto 1.3 m hight dia as required with bend including taking down old complete all as specified and directed.
S&F in repair Vitreous China Urinal, half stall type, including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60 mm long, brass screws, pointing around urinal back in cement fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe and waste coupling all as directed. Make : Hindustan/Cera/Parryware.
S&F PVC connection 15mm size with PTMT nuts of length 450mm all as specified and directed.
M&L cement concrete 1:2:4 type B1( 20 mm graded stone agg. )in surface channels and drains all as specified and directed.
Demolition and breaking up drain pipes of 150mm inner dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar all as specified and directed.
Excavating in trenches n exc 1.5m wide and not exc 1.5m in depth for foundation etc., or for shafts, wells, cesspits, manholes, pier holes,laying of pipes, cables etc., n exc 10 Sqm on plan and not exc 1.5m deep and getting out in hard/dense soil.
M&L cement concrete in foundations, filling and mass concrete type D-2, 1:4:8 (40mm graded stone aggregate).
M&L for cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in copings, benching concrete in manholes including necessary Use and waste of Form work etc complete all as specified and directed.
M&L for rendering 15mm thick on fair faces or brick work or concrete surface in CM 1:4 using waterproofing compound finished even and smooth without using extra cement all as specified and directed. Note :- Supply only WPC shall be measured and paid separately.
Supply only integral water proofing liquid compound all as specified and directed.
M&L for precast reinforced concrete type B-1, 1:2:4 (20mm graded aggregate) set in cement mortar 1:4 as in cover slabs all as specified and directed.
TMT bars 6mm dia and over and upto and including 8 mm dia cut to length bent to shape required including cranking bending and binding with MS wire not less than 0.90mm dia all as specified and directed.
M&L for MS round bars for handles 10mm dia and over, cut to length, bent to shape required of Ge-410-W 9Gde-E-250) quality-A or Fe-290 (gde-E-165) all as specified and directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in bed to drain pipes 150mm dia including packing under and haunching against the sides of pipes after they are laid and tested all as specified.
M & L for 150 mm dia Salt glazed stoneware drain pipes of grade 'A', laid in trenches and jointed complete with collars and required gradient all as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.
Removing excavated material (Soils) not exc 250m but n exc 500m and depositing where directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds etc.
Cutting into exising manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required for internal dia of pipe 150 mm.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed.
Taking down carefully unserviceable main switches/DB's off size from their position and removing materials from site all as specified and as directed by Engr-in-Charge
Taking down existing sub main wiring with aluminum conductor cable of 2 runs of 4/6/10 sqmm with GI earth wire on and including wooden batten and removing materials from the site and making good distrubed surface of walls and and roofs complete all as specified and as directed by Engr-in-Charge
Material and Labour for point wiring with PVC unsheathed multi standard 1.5 Sqmm FRLS copper Cable drawn in and including PVC casing capping 20/25 mm width complete with all accessories including 1.6 mm thick pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover for fixing switch,socket ,regulator etc of suitable size to be fixed on wall respectively including white washing/colour washing/distembering to match the disturbed surfaces including PVC unsheathed multi standard 1.5 Sqmm FRLS copper Cable as earth continuvity connected with common earth dolly complete for One light point controlled by one, one way switch 5 Amp complete all as directed
All as per item No 124 above but for one fan point controlled by one, one way switch 5 Amp all as specified and directed.
All as per item No 124 above but for one 3 pin switch socket outlet 5 amp independent all as specified and directed.
All as per item Sl No 124 above but for one 3 pin socket outlet 15 Amp independent with cable of size 2.5 Sqmm for piont wiring and 2.5 sqmm as in contineous earth wire all as specified and directed.
M&L complete for switch piano flush button single pole one way 5 Amp 240 V all as specified and directed.
M&L for switch socket combination 2 in 1,3 pin 5 Amp flush type 240 volts complete all as specified
M&L for switch socket combination 2 in 1,3 pin 16 Amp flush type 240 volts complete all as specified
M&L complete for ceiling rose surface backelite three terminal 240 volts complete all as specified
S&F fan regulator, electronic, step type , flush mounting complete all as specified and as directed.
Supply and Fix REGAL Batten for LED tube with single LED Lamp 1x 20 w, Ultra bright glass LED Tubelight with very high efficacy suited for installation in T5/T8 fitting with lamp holders etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed. Make & Model No for Batten :CROMPTON Cat No Regal LED Batten Cat No DIJB12LT8-20and LED Lamp LED Lamp Crompton Cat No LGT8-20-865-2 or equivellent model of other Make
S&F LED building security light made of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP-66 protection with SPD LED street light of 20 Watt all as cat part no .LSTS-20-CDL-M of Crompton make or equivalent make of Bajaj/Philips/Wipro/Havells.with sutable size bracket made to shape of 40 mm dia GI pipe medium grade of 1.4 mtr length including MS clamps 25 x 4 mm - 02 Nos with nut bolts washers complete all as specified and directed.
Supply and Fix recessed type LED Light fitting 28 Watts of size 2 x 2 LED edge-lite luminaries suitable for armstrong/grid ceiling complete for low celing application with LED Drive of 28 Watts complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as directed Model No : Havells Cat No ENDURASLIMPROPLUS2X2PLR28/36WLED840MOD and Drivers Cat Part No. LEDDRIVER36V28WS or equivellent model of other Makes .
Sub main wiring with two single core stranded copper conductor unsheathed PVC insulated FRLS cable 1100V grade with 6 sq mm drawn through suitable size of non-metallic PVC rigid conduit/casing caping with one run 6 sqmm copper conductor FRLS cable as earth conductor and conduit accessories fixed up in surface/ recessed as required, including connecting up complete all as specified and directed. NOTE ;- Two runs of 6 sq mm cable and one run of 6 sq mm earth continuity copper conductor and one run of PVC conduit / casing caping shall be measured as one unit
S&F sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 8 Way complete all as specified and as directed .
S&F sheet metal enclosure factory made double door for DB 240 volts with 200 Amps rated bus bar SPN 4 Way complete all as specified and as directed .
S&F sheet metal enclosure factory made single door for DB 240 volts SPN 2 Way complete all as specified and as directed .
M&L complete for MCB TPN 40 Amps 240 volts, 50 Hz AC supply including taking down unserviceable complete all as specified & directed.
M&L complete for MCB SPN 10 - 32 Amps 240 volts, 50 Hz AC supply including taking down unserviceable complete all as specified & directed.
M&L complete for MCB SP 06 to 32 Amps 240 volts, 50 Hz AC supply including taking down unserviceable complete all as specified & directed.
Taking down ceilng fan/ exhast fan, dismantling blades and removing fan and blades to store, Painting of fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc and refixing ceiling fan and connecting up including provision of cable from ceiling rose or connector of fan complete all as specified & directed.
S & F over surface PVC conduit complete with accessories of size 25mm AF Net complete all as directed.
S & F over surface PVC conduit complete with accessories of size 40mm AF Net complete all as directed.
Supply, installation, testing and commissioning of 1 KVA Isolation transformer, single phase, 50 Hz, copper wound, class of insulation A, metallic body powder coated designed for Input voltage range 240 +2.5 % and output voltage range 240 + 2.5 %, ratio 1:1, vector group: Dyne 11, efficiency more than 95%, potential difference between neutral to earth less than one volt with all standard fittings, including wall mounted stand for fixing/ keeping isolation transformer indoor type complete all as specified and as directed.
M&L for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth (in vertical) earth pit not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised ironl including PCC pit in PCC 1:2:4 type B-1 pre-cast RCC cover slab using reinfocement with XPM weighing not less than 1.87 kg/Sqm with suitable handle made of 12mm round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube flor watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 7.5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in Electrical Plate No 3 of SSR Part-I and testing on completion.
M & L for maintenance free chemical earthing Pipe in Pipe technology . Having 01 No GI Pipe in Pipe electrode length 3 mtr , Dia 76 mm filling with 2 Bags/ 60 Kgs EBFC chemical based ENNOV back fill compound or another equivalent compound incl construction of PCC pit and cover, earth lead protection pipe etc all as directed by engr-in-charge. Note-Copper strip will measured and paid seprately.
M&L for 20 x 3 mm Copper Strip for inter connection of earthings and to connect the earthing to the main panel .
Supplying, laying,saddling in wall by using suitable size saddle and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoure d,electric power cables (heavy duty )1100 volts grade with stranded aluminium conductor of size 10 sqmm x 2 core incl taking down old one.
Supply, laying, taking down and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured.electric power cables (Heavy duty) 1100 Volts grade with stranderd aluminium conductor of size 10 sqmm x 4 core incl taking down old one.
Supply and spread river sand for cable cushioning in trenches all as specified in clause 19.75 of SSR Part-I. Note:- Punned thickness of sand shall only be measured.
Supply and laying well burnt sub class B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
M&L for GI pipes light grade galvanised with all fitting and fixed complete to poles/route/drains etc and ceillings or laid in floors of 50 mm dia.
Excavating in trenches n exc 1.5m wide and not exc 1.5m in depth for foundation etc., or for shafts, wells, cesspits, manholes, pier holes,laying of pipes, cables etc., n exc 10 Sqm on plan and not exc 1.5m deep and getting out in hard/dense soil.
M&L for 25mm bore GI pipes, medium grade, galvanised with all fittings such as bends, tees etc complete laid in trenches all as specified and as directed.
M&L for 40mm bore GI pipes, medium grade, galvanised with all fittings such as bends, tees etc complete laid in trenches all as specified and as directed.
M&L for 50mm bore GI pipes, medium grade, galvanised with all fittings such as bends, tees etc complete laid in trenches all as specified and as directed.
M&L for 25mm bore GI pipes, medium grade, galvanised with all fittings such as bends, tees etc complete fixed on walls, ceilings or laid in floors all as specified and as directed.
M&L for 40mm bore GI pipes, medium grade, galvanised with all fittings such as bends, tees etc complete fixed on walls, ceilings or laid in floors all as specified and as directed.
M/s. VIJAY ELECTRICALS
DHANSHRI ENTERPRISES
Manak landmarks
ASHIRWAD ELECTRICALS
Phoenix Infra
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .