| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹30.5 L+₹7,330.84 (0.24%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹31.4 L+₹1.0 L (3.37%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L3 | Rejected-Finance BEING L2 BIDDER | |
| 4 | L4₹33.8 L+₹3.4 L (11.2%)Rejected-Finance | L4 | Rejected-Finance BEING L2 BIDDER | |
| 5 | L5₹34.3 L+₹3.9 L (12.8%)Rejected-Finance | L5 | Rejected-Finance BEING L2 BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Aug 2022, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPECIAL REPAIR TO BUILDING NO ET-463 AND ET-401 AND OTHER SANCTIONED WORKS AT CHANGSARI MILITARY STATION UNDER GE RANGIA
2022_MES_539984_1
8582/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
CHANGSARI
AS PER NIT
9 documents required · 9 mandatory
₹500
GE RANGIA
₹80,000
Yes
27 Aug 2022
22 Jul 2022
19 Aug 2022
22 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position, complete all as specified and as directed by Engineer-in-charge.
M&L 2nd class hard wood in scantling wrought timber unframed and fixed, complete all as specified and as directed by Engineer-in-charge.
Demolition of reed, lathing, single or double, including battens and plaster or chicken wire lathing, complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in any cement mortar complete all as specified and as directed by Engineer-in-charge.
M&L for brick work with sub-class `B' old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed by Engineer-in-charge.
M&L for G I Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste, complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or one side of lathing in cement mortar 1:4, surface finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on other than fair faces of brick work or one side of lathing in cement mortar 1:6, surface finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L rendering 15mm thick on fair faces of brick work or concrete block surface in cement mortar 1:6, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surface and applying two coats of distemper oil emulsion on wall surfaces over a coat of chalk whiting primer complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of cement based paint on walls, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated wood or wood based surfaces of any description, exceeding 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials, new or old of any description and girth, not otherwise described and treated with two coats of cresote oil, complete all as specified and as directed by Engineer-in-charge.
M&L for Mild steel TMT bars 10 mm dia. and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips, complete all as per specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O, complete all as per specified and as directed by Engineer-in-charge.
M&L for for precast cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in columns, posts, boundary pillars etc. set in cement mortar 1:4 complete all as specified and as directed by Engineer-in-charge.
Dismantling Asbestos Cement (Corrugated, Semi corrugated etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated or semi-corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/cladding to wall, fixed with self tapping screws or J hooks, complete all as specified and as directed by Engineer-in-charge.
Demolition of unreinforced cement concrete in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in footpath / hardstanding / pavings / plinth protections, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description not exc. 1 sqm each, complete all as specified and as directed by Engineer-in-charge.
Taking down shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each, complete all as per specified and as directed by Engineer-in-charge.
S&F 35 mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. for windows and ventilators etc complete all as per specified and as directed by Engineer-in-charge.
S&F 30 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both side and both faces is covered with decorative face veneer with lipping, complete all as per specified and as directed by Engineer-in-charge.
S&F 75 mm long medium weight, cold rolled mild steel butt hinges, complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm mild steel pressed handles, oval type, stove enamelled black, complete all as per specified and as directed by Engineer-in-charge.
S&F 100 mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed, complete all as per specified and as directed by Engineer-in-charge.
S&F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F aluminium alloy 300 mm anodised sliding door bolts with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast - aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F 100 mm long medium weight, cold rolled mild steel butt hinges, complete all as specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation,etc) or insulation board/Slabs/blankets of any thickness including cover fillets, complete all as specified and as directed by Engineer-in-charge.
S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600x600mm comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 22x35x0.60mm with 4mm dia GI wire as suspender and including 4mm thick E-Board classic (decorative type) including fixing arrangement from steel truss of any type and applying three coats of white wash on exposed surface, complete all as per specified and as directed by Engineer-in-charge.
S&F 3 mm thick sheet glass, ordinary quality in squares not exceeding 0.5 Sqm in each pane fixed with cut & mitred beads, complete all as specified and as directed by Engineer-in-charge.
S&F galvanised mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
S&F in repair galvanised mild steel wire cloth, 0.56 mm dia of wire and average width of aperture 1.18 mm and fixed with galvanised wire staples, complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as per specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as per specified and as directed by Engineer-in-charge.
M&L for Coloured Glazed ceramic tiles 300 x 200 x 6 or 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match over and including 10 mm thick screed in CM (1:4), complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of morter (1:6) for laying floor finishes complete all as specified and as directed by Engineer-in-charge.
M&L glossy finish chequered cement concrete tiles 20cm x 20cm x 22mm thick set jointed and pointed in with grey cement and pigment laid over floor and pointed in neat cement slurry in floors, complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:2:4) type B-1 ( using 20 mm grade crushed stone aggregate) as in coping roof kerbs or mud stops, rounded or chamfered on edges with necessary form work as required complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing treatment of old distempared surfaces and applying two coat of oil bound distemper on walls over one coat of chalk whiting primer, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of old steel surfaces of any description not otherwise described over 10cm girth or width and applying one coat of synthetic enamel paint, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing old painted surfaces of walls including washing, rubbing down and stopping and applying one coat of cement based paint, complete all as per specified and as directed by Engineer-in-charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. .frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail,; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised, complete all as per specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as per specified and as directed by Engineer-in-charge.
S&F15 mm bore fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by Engineer-in-charge.
S&F fancy type 15mm dia bore pillar tap cast copper alloy with capston heads chroumium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge.
Supply and fix fancy type, CP, stop valves 15 mm, cast copper alloy, screwed dowd, high pressure with crutch or butterfly handle, swrewed both ends for iron or for unions and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fix 100mm dia grating doom of PTMT with minimum weight 25 grams complete all as specified and as directed by Engineer-in-charge.
S&F 15mm dia PVC connection pipe with PTMT nuts of length 450 mm complete all as specified and as directed by Engineer-in-charge.
S & F Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges complete all as per specified and as directed by Engineer-in-charge.
S&F chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
S&F PVC valveless, syphonic action type 10 ltr capacity low level flushing cistern, white, with inlet, ball valve, float and handle including brackets and 32 mm bore PVC flush pipe, complete all as per specified and as directed by Engineer-in-charge.
S&F Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand etc., complete all as per specified and as directed by Engineer-in-charge.
S&F Vitreous China squatting pan "Orissa" patern size 580x440mm white with integral foot rest including connection to trap and to flushing pipe, anti-syphonage pipe, etc including 'P' or 'S' trap complete all as per specified and as directed by Engineer-in-charge.
S&F 32 mm dia waste coupling of PTMT (half or full threaded) complete all as specified and as directed by Engineer-in-charge.
S&F 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per sqcm fixed to wall complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm dia PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors, complete all as per specified and as directed by Engineer-in-charge.
S&F GI tube 15 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
S&F GI tube 20 mm bore medium grade with fittings and fixed complete to wall, ceiling or laid in floor complete all as specified and as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tanks triple layered ISI Marked (cylindrical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position all as specified and directedin SSR Pt I, complete all as specified and as directed by Engineer-in-charge.
S&F Vitreous china urinals, half stall type white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius in cement mortar 1:6, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 ( using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of guage not exc. 63mm deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders, complete all as per specified and as directed by Engineer-in-charge.
M&L 75 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) in footpath / hardstanding / pavings / plinth protections, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
S&F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel or iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer over 10cm width or girth complete all as specified and as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 60 mm thickness of M-35 grade with grey cement and pigment including, complete all as per specified and as directed by Engineer-in-charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface, complete all as per specified and as directed by Engineer-in-charge.
M&L 100 mm thick Cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in footpath / hardstanding / pavings / plinth protections, finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
'M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation, complete all as per specified and as directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 of 80 mm thickness of M-40 grade with grey cement and pigment, complete all as per specified and as directed by Engineer-in-charge.
Dismantling of unframed fillets, rails, posts, rafters, purlins etc., under 40 Sqcm in section, complete all as specified and as directed by Engineer-in-charge.
M&L second class hard wood plain fillets, square or rectangular or triangular in section, clean sawn, secured with nails or brads having sectional area exceeding 13 sqcm but not exceeding 25 sqcm complete all as specified and as directed by Engineer-in-charge.
S&F solid PVC wall paneling consisting of 5 mm thick PVC wood grain printed PVC sheet inclusive of solvent cement and fixing at site as per specification and directed in any position with screws, complete all as per specified and as directed by Engineer-in-charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as per specified and as directed by Engineer-in-charge.
M&L cement concrete type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in surface channels and drains, complete all as specified and as directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends complete all as specified and as directed by Engineer-in-charge.
M&L rendering 15mm thick on fair faces of brick work or concrete block surface in cement mortar 1:4, surface to be finished fair & even without using extra cement, complete all as specified and as directed by Engineer-in-charge.
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators etc and separating serviceable fittings for reuse in the same work and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc all complete all as specified and directed complete all as per specified and as directed by Engineer-in-charge.
Taking down carefully unserviceable main switches and DB’s including wooden boards and removing from site including making good disturbed surfaces of walls complete all as per specified and as directed by Engineer-in-charge.
Dismantling of house service brackets of any size and type and making good the distrubed wall surfaces complete all as per specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends . elbow crosses etc with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per serial item No. 94 above but for one fan point controlled by one switch.
All as per serial item No. 94 above but for one 3 pin socket outlet 5 AMPs on independent board.
All as per serial item No. 94 above but with 4 sqmm (nominal area) cable with 4.00 sq mm size copper earth continuity conductor of green colour for 15 A socket outlet on independent boards.
Supply and fix switch socket combination 05/16 Amp, 5 in 1, flush type universal, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 2 in 1, 3 pin, 5/6 Amp flush type universal, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 5 / 6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix fan regulator electronic type, rotary step, SP 240 Volt, suitable for 1200/1400 mm sweep ceiling fans complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube light fittings1 x 20 Watt, 220 V, AC decorative box type with driver holder including LED tube rodconnecting up with three core flexible copper conductor cable from ceiling rose to tube light fitting complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 350 x 300 x 50 mm deep complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 04 way DB single door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 08 way DB single door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fix sheet metal enclosure powder painted for MCB SPN 12 way DB single door with din rail and bus bar including making good to the disturbed surface matching with the existing complete all as specified and as directed by Engineer-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SP and current carrying capacity 6 To 32 AMP in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 40 to 63 AMP in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of SP and current carrying capacity 40 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed by Engineer-in-charge.
Taking down old ceiling fan/exhaust fan and refixing only serviceable fans after testing to its original position/location and handing over old unserviceable ceiling/exhaust fans to MES store yard complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 30W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F House service bracket (Hook type) complete with 40 mm dia GI pipe 3.00 m long, medium grade, two Nos. of 90 degree bends, M.S hook and stay or guy complete all as per specified and as directed by Engineer-in-charge.
Supplying and fixing 10 Sqmm, twin core, flat cable 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire including taking down old unserviceable, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no. 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply and fix electric water heater, storage type steel body with opper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, hermostate, NRV, connection piece etc., complete all as specified and as directed by Engineer-in-charge.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed by Engineer-in-charge.
S&F PVC rectangular block for mounting, DBs, etc. with 3mm thick plastic laminated sheet cover of size 250 x 200 x 50 mm deep complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .