| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.0 L+₹2.3 L (48.1%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹7.7 L+₹3.0 L (62.6%)Rejected-Finance NOT FOUND | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹8.7 L+₹4.0 L (83.6%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹8.8 L+₹4.0 L (84.0%)Rejected-Finance NAGAR PANCHAYAT PATHARDEVA DEORIA | L5 | Rejected-Finance Other than L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
16 May 2024, 6:00 pmClosed
GE (AF) SIRSA
GE (AF) SIRSA, HARYANA-125055
REPAIR/MAINT OF FLAMEPROOF NATURE INTERNAL ELECTRIFICATION WORKS INCLUDING CONNECTED FITTING AND FIXTURE AT AF STN SIRSA
2024_MES_650888_1
GE/SRA/T-09/2024-25
Open Tender
Miscellaneous Works
Item Rate
240 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (AF) SIRSA
₹30,000
Yes
30 May 2024
23 Apr 2024
17 May 2024
23 Apr 2024
16 May 2024
2 May 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc (except light fittings), removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing steel conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit)
All as per item No. 02 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 02 above but using 2.50 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.50 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
All as per item No. 02 above but using 4.0 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 4.0 sqmm green FRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit).
M&L for Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn through and including Rigid Metallic ERW Conduit 19/20 mm in size, medium grade, ISI marked and its Accessories with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, Earth Continuity Wire connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP, complete all as specified and as directed. (NOTES :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
Add to item no 06 for each additional light/fan point on the same circuit complete all as specified by Engineer-in-charge.
M&L for Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Cable, drawn through and including Rigid Metallic ERW Conduit 19/20mm in size, medium grade, ISI marked and its Accessories in Concealed (Partly)/ Surface (Partly) with necessary grouting of required size and depth on Wall and Making Good in Cement Mortar 1:3, Earth Continuity Cable connected to Common Earth dolly for ONE 6 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed. (NOTES :- (i) Quoted rate shall be deemed to be inclusive of the cost of terminal box & laminate cover. (ii) Cost of cutting chases for concealed wiring and making good shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
-ditto- but using 4.0 sqmm FRLSH wire for both mains and earth wire in and including 19/20 mm Rigid Metallic ERW conduit complete
S&F Flame Proof Sub-main Wiring with 2-Runs of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 2.5 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in existing ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Three runs of single core 2.5 sqmm wire shall be measured as one unit. Conduit, if replaced, shall be measured and paid seperately)
S&F Flame Proof Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in existing ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Three runs of single core 4.0 sqmm wire shall be measured as one unit. Conduit, if replaced, shall be measured and paid seperately)
S&F Flame Proof Sub-main Wiring with 4-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 2-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty Cable along with the Wiring drawn in existing ERW/GI CONDUIT including taking down existing sub main wiring complete all as specified and directed. (NOTE: Six runs of single core 6.0 sqmm wire shall be measured as one unit. Conduit, if replaced, shall be measured and paid seperately)
S&F ERW Conduit of size 19/20mm dia including Taking down/out Old Unserviceable Conduit in recess on wall, ISI marked, heavy duty with all Conduit Accessories and Making Good Surfaces to match the Exiting Treatment (as per Site requirement) complete all as per specified and as directed. (NOTE: Quoted rate shall be deemed to include cost of cutting chases for concealed wiring and making good as per existing specifications. No claim in this regard shall be entertained at a later stage)
-ditto- but for ERW Conduit of size 25mm dia
-ditto- but for ERW Conduit of size 32mm dia
S&F Flameproof Fan Regulator, Single Pole, 230 Volt, Electronic type and complete all as specified and as directed.
S&F Switch Flame Proof Rotary type with Termination Box in LM6, 16 Amp, Single Pole, 250 Volt , complete all as specified and as directed.
S&F Flame Proof & Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 16 Amp, 250 Volt, 2 Pin and Earth Plug, Fully Interlocked suitable for installation in hazardous as per IS-2147/62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and, complete all as specified and as directed.
S&F Flame Proof & Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 25 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and complete all as specified and as directed.
S&F Flame Proof & Weather Proof Switch Socket with Plug Combined in LM6, Termination Box in LM6, 32 Amp, 415 Volt, TPN, 3 Pin and Earth Plug, Fully interlocked suitable for installation in hazardous as per IS-2147/ 62 Alluminium alloy/Cast Iron Neoprene Gasket Degree of Protection IP 65 and Certified CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and complete all as specified and as directed.
Taking down and Re-fixing of serviceable tube light fitting, any type, after minor repairs including necessary electric connection & testing complete all as specified and directed. (NOTE: New Tube light, if required, shall be paid seperately as "Supply Only")
Supply only LED tube light 20 watt complete all as specified and as directed.
S&F Flame Proof Weather Proof LED Tube Light Fitting 1x20 Watt (4 Feet) with product in Aluminium Die-cast Alloy LM6 complete with Construction of Gas Gr. IIA, IIB, Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Elecrically Connecting up and complete all as specified and as directed.
S&F Flame Proof Weather Proof LED Tube Light Fitting 2x20 Watt (4 Feet) with product in Aluminium Die-cast Alloy LM6 complete with Construction of Gas Gr. IIA, IIB, Tested and Certified by CIMFR DHANBAD & CCOE NAGPUR, BS with ISI marked and Elecrically Connecting up and complete all as specified and as directed.
S&F in repair Flameproof LED Flood Light fitting, of 120 WATT capacity, in high pressure die cast LM6 aluminium housing, certified by CMRI Dhanbad, with lens and toughened glass cover with integrated constant current electronic driver complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 120 lumen/watt (b) CRI not less than 80, (c) THD < 25% (d) Power factor not less than 0.95 (e) having in built short circuit and surge protection upto 5 kV (f) colour temperature not less than 5700 degree K (g) life not less than 50000 hours of operation (h) Weather protection grade: IP65 (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
-ditto- but Flameproof LED Flood Light of 200 Watt capacity
S&F in repair Flame Proof Weather Proof High-Bay LED 100 W Fitting, IP65 grade ingress protection, in Aluminium Die-cast Alloy LM6 Construction and Certified by CMRI DHANBAD with ISI marked and Elecrically Connecting up and complete all as specified and as directed. (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
S&F in repairs LED Street Light fitting, 45 WATT capacity as mentioned under, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation (NOTE: (1) List of approved makes has been provided in particular specifications. Contractor shall ensure that luminaire provided comply with the aforesaid specifications. No claim shall be entertained during currency of work.. (2) Wire for electric connection shall be measured and paid separately)
S&F in repairs PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 2.50 sqmm, 3 core,1100 Volt, conforming to IS 694 all as specified and directed
S&F in repair Bracket/Arm suitable for street light fittings, made out of 25 mm bore (light grade) GI pipe length not exceeding 1.20 metre long, fixed with 02 sets of flat iron clamp of size 40mm x 6 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed.
S&F in repair MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'C' Series for fixing on existing MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair MCB Single Pole & Neutral, 06-32 Amp, 240 Volt, AC, 'C' Series for fixing on existing MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair MCB Single Pole & Neutral, 40-63 Amp, 240 Volt, AC, 'C' Series for fixing on existing MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair MCB TPN, 32 Amp, 240 Volt, AC, 'C' Series for fixing on existing MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair MCB TPN, 63 Amp, 240 Volt, AC, 'C' Series for fixing on existing MCB DB’s, 10 kA, 50 Hz including Connecting up and testing complete all as specified and as directed.
S&F in repair MCCB, 4 pole, 63 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in existing DB complete all as specified and directed.
S&F in repair Weather proof & flame proof TPN DB, 8 way, in cast alumnium alloy LM6 construction, provided with 200 Amps neutral & earth link bar (approved by CIMFR DHANBAD & CCOE NAGPUR) and Elecrically Connecting up & testing complete all as specified and as directed and provided with the follwoing accessories :- (i) Incomer MCCB, 63 Amps, 4 Pole, 16 kA, 50 Hz, thermal magnetic, Adjustable type - 01 No (ii) Outgoing MCB, SP, 6-32 Amps, 240 Volt, AC, 'C' Series, 10 kA - 24 Nos NOTE: Quoted rate shall be deemed to be inclusive of the cost of MCCB & MCBs.
S&F in repair Weather proof & flame proof SPN DB, 8 Way, in cast alumnium alloy LM6 construction, provided with 200 Amps neutral & earth link bar (approved by CIMFR DHANBAD & CCOE NAGPUR) and Elecrically Connecting up & testing complete all as specified and as directed and provided with the follwoing accessories :- (i) Incomer MCB, SPN, 32 Amps, 240 Volt, AC, 'C' Series, 10 kA - 01 No (iii) Outgoing MCB, SP, 6-32 Amps, 240 Volt, AC, 'C' Series, 10 kA - 06 No NOTE: Quoted rate shall be deemed to be inclusive of the cost of MCBs.
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in soft/loose soil and getting complete all as specified and as directed.
Returning, filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and as directed.
Removal of excavated material to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor of size 4 Core 25 Sqmm, laid in trench or fixed to wall/passing through pipe/pole incl necessary aluminium thimbles, jointing and testing complete all as specified and directed. (Note :- Necessary earth work to be measured and paid separately.
M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, laid perpendicular to the cable for Cable Protection, complete all as specified and as directed.
M&L for replacement of Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
AMBIKA ENTERPRISES
shiv shanker enterprises
NISHTHA BUILDERS
M/s Shree Bala Ji Construction Company
M/s Satguru Traders
P.K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .