Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-Finance FLAT NO 107 C WING SKYWAYS SERENO LOHEGAON PUNE 411 047 | PUNE | PUNE | MAHARASHTRA | 411047 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹39.9 L+₹41,118 (1.04%)Rejected-Finance FLAT NO B 205 S NO 296 2 DIVINE HOMES PORWAL ROAD LOHEGAON PUNE 411047 | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance not being lowest | |
| 3 | L3₹40.8 L+₹1.3 L (3.41%)Rejected-Finance | L3 | Rejected-Finance not being lowest | |
| 4 | L4₹41.0 L+₹1.5 L (3.87%)Rejected-Finance | L4 | Rejected-Finance not being lowest |
Tender Value
₹49.8 L
EMD Value
₹99,520
Closing Date
4 Mar 2023, 6:00 pmClosed
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Kendriya vidyalay Gate , beside Unlimited (Mega Mart) Mall, Pune - 411 012
Special repair to Bldg No. P-239 (MD accn of Maj to Lt Col), provision of LT panel and allied work for regulated power supply in Bldg No. 412, 413 and 414 and provision of area drainage in single JCOs living accn at CME, Pune
2023_MES_574867_2
8391/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D, category a(I) and also refer tender document
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹99,520
Yes
6 Mar 2023
9 Feb 2023
6 Mar 2023
9 Feb 2023
4 Mar 2023
19 Feb 2023
10 Feb 2023 - 18 Feb 2023
Amount
Dismantling of single layer Mangalore Pattern roof tile laid dry complete all as specified and directed.
All as per item No.1 above, but bedded in lime or cement mortar complete all as specified and directed.
Dismantling battens for tiles, shingles etc, of any size including tilting fillets spacing exc. 15 cm complete all as specified and directed.
Dismantling timber scanttlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F Framed work such as roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
S&F rolled sections as in main and cross beams, hips and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates etc Fe-410-W (Gde E-250) Quality A complete all as specified and directed.
M & L for preparation of new or previously untreated surfaces of iron and steel of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc. complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley, gutters etc. complete all as specified and directed.
M & L for false ceiling with 4mm thick designer 'E' board fixed on GI grid work with powder coated finish on exposed surface of size 0.6 x 0.6m consisting of GI angle supported on wall of size 24mm x 28 x 0.7mm main tee of size 24mm x38mm x 0.7mm, cross tee of size 24mm x 28mm x 0.7 mm using purpose made members interlocking to each other and 40mm x 3mm flat GI mild steel strip suspender made to shape at 1200mm c/c fixed with 3mm dia GI wire and making holes etc all as directed including two coats of white wash on ceiling after preparation of surfaces and as per manufacturers instruction including taking down old ceiling Make of GI Grid work : Armstrong/Swastik/Techno Grid Make of 'E' board : Everest/Indian Gypsum/Armstrong or equivalent approved .
Dismantling water tanks and removing to store capacity exc. 500 & not exc. 1000 ltrs complete all as specified and directed.
S&F 1000 ltr. capacity rotational moulded polyethylene water storage tanks cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I all as specified and directed.
M&L 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in roof/floors other than ground level beam, stair case, landing, chajjas and similar items including water proofing treatment in any layers and removal of debris to distance exceeding 250m and not exceeding 500m from the site complete all as specified and directed.
M&L 40 mm thick, PCC 1:2:4 (Type B1 using 20 mm graded stone aggregate) as in levelling course to match the undulations of roof and in coping, roof kerbs, fins including benching etc complete all as specified and directed
M&L 10 mm thick cement screed in CM 1:3 mixed with water proofing compound of approved make over RCC roof slab and vertical surface, finished even and smooth by using steel trowel complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( wt not less than 150 gms /sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltr/Sqm by forced complete all as specified and directed. Four course roof treatment consists of as under :-
Applying one coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr per sqm.
Laying of APP based membrane as specified thickness and weight.
Applying one coat of bitumen grade 85/25 @ 1.2 Kg/Sqm.
Applying two coat of aluminium paint @ 100ml/sqm
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing and rubbish off the premises complete all as specified and directed.
Demolition of cement concrete (unreinforced ) in ground floors and pavings not exceedidng 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 75mm thick PCC type D-2 (1:4:8) using 40mm graded stone aggregate as in sub base etc complete all as specified and directed.
M&L For 25 mm thick, type B0, 1:2:4 (12.5 mm graded stone aggregate) as in sub base etc complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6. complete all as specified and directed.
M & L light shade vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
M & L coloured non-skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc. complete all as specified and directed.
M & L light shade vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting, dado, risers of steps and pillasters etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and directed.
M& L rendering 10mm thick cement mortar in 1:4 as in backing coat for fixing tiles complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface, 350mmx250mmx7mm /450mmx350mmx7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat complete all as specified and directed.
Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premisses complete all as specified and directed.
M& L 20 mm thick, Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite etc complete all as specified and directed.
M&L machine cut cuddappah stone slab 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
Rounding to edges of stone slabs, such as in steps, cooking platform and other similar situation complete all as specified and directed.
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit all as directed.
All as per item No.32 above, but 20mm bore
S&F 15mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specifeid and directed.
S&F 20mm bore medium grade galvanised steel water tubing with all fitting & fixed complete to walls or ceiling or laid in floors all as specified and directed.
Refixing 15mm bore old steel water tubing & connection in new or old position of wall, ceiling, floor etc complete all as specified and directed.
All as per item No.36 above, but 20mm bore. Note for sl item Nos. 36 & 37 :- The serviceable steel tubing obtained for sl item No. 34 & 35 shall be re-used in this item.
M& L For Cutting chases, pinning in stone concrete block or slab, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth etc. complete all as specified and directed.
S & F in repair under counter wash basin vitreous china coloured including CI bracket, 15 mm dia polythene connection, 32 mm dia chromium plated (CP), waste coupling, chain and plug waste pipe 90 cm long and all necessary inlet outlet connections etc. complete all as specified and directed. Make :- Hind ware cat No. 10065 or equivalent approved by GE.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) with and including seat cover complete all as specified and directed
S&F in repair 10 ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white, with inlet ball valve, float and handle including bracket and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed.
S&F in repair brass chromium plated two way bib cock fancy type, 15mm bore ( min Wt. 550 grams) of approved make by EIC/ GE etc. complete all as specified and directed.
S & F brass chromium plated, 15 mm bore health faucet, ( flexy type) 1.00 mtr. Long of approved make by EIC/GE etc. complete all as specified and directed.
S&F in repair 15 mm dia long body pillar taps, cast copper alloy, with capstan heads, chromium plated fancy type , screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long shanks and flynuts, screwed for iron pipe complete all as specified and directed.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F in repair 15mm dia, long body fancy type bib tap, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repair 15mm dia stop valve chromium plated fancy type screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for union complete all as specified and directed.
S & F in repair overhead shower 100 mm dia round shape single flow (ABS Body Chrome plated with grey face plate ) with Rubit cleaning system complete fixed to ceiling all as specified and directed by Engineer-in Charge. Make - Jaquar Cat No. OHS-1989 or equivalent approved make indicated in list of makes in tender as approved by GE.
M&L cement concrete type E-2, 1:5:10 (40 mm graded stone aggregate) lean concrete as in sunkun floor for filling etc. complete all as specified and directed.
M&L 40mm thick cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in sunkun floor complete all as specified and directed.
M&L 15mm thick plastering in CM 1:3 along the wall of toilet and bath mixed with 3 % WPC or as instructed by manufacturers and finished even and smooth without using extra cement complete all as specified and directed.
Supply only WPC all as specified and directed.
M&L bitumen blown any grade applied hot, two coats to concrete surfaces at the rate of 1.5 kg per sqm per coat complete all as specified and directed.
M&L Polythene film black 50 micron laid in floor complete all as specified and directed.
S&F in repair 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
All as per item No.55 above, but 110mm complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) bend any radius complete all as specified and directed
All as per item No.57 above, but 110mm dia complete all as specified and directed.
S&F in repair 75mm PVC (SWR) junction single (single T) equal or unequal complete all as specified and directed.
All as per item No.59 above, but 110mm bore of pipe complete all as specified and directed.
M&L in repair 75mm PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified and directed.
All as per item No.61 above, but 110mm complete all as specified and directed.
S&F in repair 75mm PVC (SWR) vent cowl complete all as specified and directed.
All as per item No.63 above, but 110mm complete all as specified and directed.
S&F in repair stainless steel sink, made out of 1.00 mm thick sheet for kitchen with plug, washer pipe cast iron cantilever brackets, connecting union overall size 495x420mm bowl size 410mm x 330mm x160mm all as specified and directed.
S&F in repair Brass chromium plated tubular towel rail, 20mm dia , D type 60cm long between flanges complete all as specified and directed.
M&L for stainless steel 304 material staircase railing of ht 1.00 m with Top rail pipe 50mm bore (16 gauge), vertical pipe 40mm bore (16 gauge) @ not exc 1.00 m c/c and at turning and corners with 10 mm thick toughened glass of height 0.75 m and necessary fitting for fixing of glass, including Tee, cross, bend, base coupling, fixed in floors with necessary fastner complete glossy finish complete all as specified and directed.
S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with stainless steel bracket guard and railing 60 cm long etc. complete all as specified and as directed.
S& F in repair stainless steel Soap dish holder complete as specified and directed by Engr-in-Charge. (Make : Jaquar or equivalent)
S& F in repair stainless steel Soap dish holder complete as specified and directed by Engr-in-Charge. (Make : Jaquar or equivalent )
S& F in repair Brass CP mixer for mixing hot & cold water screwed down for15 mm size iron pipe and fixed all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutters from the frames) not exc 1.5 sqm each and removing from site complete all as sepcified and directed.
All as per item No.73 above, but exc. 1.5 sqm and not exc. 4 sqm complete all as specified and directed.
S&F 2nd class hard wood, plain, solid straight chowkhats and frames, wrought, framed rebated on the solid rounded or chamferred,put together with glue pinned at joints etc. complete all as specified and directed
S& fixed 2nd class hard wood 35 mm thick factory made glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) complete all as specified and directed .
S& fixed factory made plain framed panelled shutters 35mm thick of 2nd class hard wood (any number of panels) with panels of timber flat on both sides feather edges or panel of 9mm BWP commercial ply over 12mm thick veneered particle board with commercial face veneers fixed to chowkhat . The size of rail and stile as per IS : 1003 (Part-1), kiln seasoned and chemically pressure treated complete all as specified and directed.
M&L for preparing new surface of wood of any decription , not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S & F Mild Steel works as in bands, straps, hold fasts etc, conforming to IS-2062-2006 (Fe-290), embedded portion duly painted with bituminous paint and sanded complete all as specified and directed.
M & L Preparing surface of iron and treating small articles such as stop, covers, gully, grating, holdfasts, end of posts area exc 0.1 Sqm each complete all as specified and directed.
M & L Cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm heights, copings, kneeless, kerbs, water troughts, bed plates, fixing of hold fasts and other similar works and the like incl weathering, slightly rounded or chamfered angles and throating as directed incl use and waste of necessary form work complete all as specified and directed.
S & F powder coated Aluminium sliding windows three track with two glass shutters using 5 mm thick glass tinted Modi guard and one shutter with stainless steel wire gauge wire cloth 0.31mm nominal dia of wire and width of aperture 1.61mm, using Aluminium powder coated sect, Aluminium cleat, PVC track, bearing, handle lock rubber beading, etc complete. Note: Size of aluminium sections are as under :- (i) Three track top & vertical – Jindal main – 2010 Section No 20621. (ii) Three track bottom - Jindal main – 2010 Section No 20620. (iii) Shutter vertical section - Jindal main – 2010 Section No 20606. (iv) Shutter top & bottom - Jindal main – 2010 Section No 20604 (v) Shutter vertical middle (interlock) - Jindal main – 2010 Section No 20605.
S & F Aluminium powder coated ventilators partly fix and partly lowered of aluminium section designed DG-2762 (40 mm x 32 mm x1.5 mm thick) (wt 0.668 kg/mtr) frame and DG-2763 and middle section of designed DG-2763 (40 mm x 32 mm x 1.5 mm thick) (wt 0.654 kg/mtr), middle section DG-2546 (17.27 mm x 17.15 mm x 1.22 mm thick) (wt 0.124 kg/mtr) including 5 mm thick pinheaded figured glass louvers with blades of 100 mm heavy duty including with aluminium lever handle fixed panel shall be provided with 5 mm thick pin headed figured glass including all necessary rubber packing, anodized aluminium snap beading fixed with minimum 6 Nos of suitable size galvanised screws with PVC plug etc. complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not therwise provided for all as directed.
M&L for framed work such as grills or grating etc with ends of bars shouldered as framed guard bars conforming to Fe-290 Gde-E-165 all as specified and directed.
S & F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube etc all as specified and as directed.
S & F factory made solid PVC moulded door shutter, 30 mm thick 2mm thick 3D wood grain Moulded PVC sheet polyurethane painted on the front face & 2mm plain colour PVC sheet on back face complete all as specified and as directed.
M&L 18/19mm thick Pre-laminated board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame including taking down existing board of any description complete all as specified and directed.
Extra over rates of block board or veneered particle board for external teak wood 18/19mm lipping 6mm thick fixed with nails all as specified and directed.
S&F 150mm hasp and staple, mild steel, wire type stove enamelled black, including bolt to hinge plate and fixed with screw. complete all as specified and directed.
S & F Mild steel butt hinges medium weight , cold rolled, 100mm, ISI marked, complete all as specified and directed.
M&L 200 mm aluminium anodised, barrel tower bolts of extruded section and fixed etc. complete all as specified and directed.
M&L 150 mm aluminium anodised, barrel tower bolts of extruded section and fixed etc. complete all as specified and directed.
S&F 125mm long aluminium anodised handles or extruded section complete all as specified and directed.
S&F 150 mm long aluminium anodised handles or extruded section complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp , staple, (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S&F Mild steel 300mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Demolition of brick or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L precast solid block masonry of block in precast cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate wall exceeding 10 cm in width and built in cement mortar 1:6 complete all as specified and directed.
M&L 15mm thick plastering on concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed.
Racking out joints/pointing to random rubble masonry, polygonal rubble uncoursed or brought upto course complete all as specified and directed.
M&L raised pointing in CM 1:4 to random or polygonal rubble, uncoursed or brought upto course complete all as specified and directed.
Taking down cement plaster on brick or stone walls or concrete surface etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L rendering 15mm thick on stone masonry surfaces in CM 1:6 finished even and smooth with sagol over and including dubbing out average 10mm thick on irregular face of walls in CM 1:6 complete all as specified and directed.
M&L rendering 5mm thick on concrete surfaces in CM 1:3 on ceiling, finished even and smooth with sagol all as specified and directed.
M&L for cement concrete 1:2:4, type B2, using 40 mm graded stone aggregate as in surface channels and drain all as specified and directed.
M&L preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over one coat primer on walls complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.
M&L Preparation of newly plastered or unplastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L complete removal of existing treatment and applying 3mm thick wall care putty and applying two coats of Oil bound distember white or tinned over one coat of primer on walls, etc complete all as specified and directed.
All as per item No.111 above, but two coats of cement base paint without wall care putty complete all as specified and directed.
All as per item No.111 above, but two coats of white wash on ceiling complete all as specified and directed.
S&F in repairs 19/20mm dia MS pipe powder coated of approved colour as in decorative type curtain rods with and including brackets for fixing curtain rod complete all as specified and directed.
M&L cement concrete 1:3:6 type C-2 (40mm graded stone aggregate) as in floors, plinth protection, path etc 75mm thick smooth finished surface without using extra cement including necessary form work complete all as specified and directed.
Chipping off loose concrete/plaster upto sound stratum of RCC members such as slab, chajjas, columns, beams and clean the surface with wire brush, washing down with water using water jet including necessary scaffolding & propping to support the structural members where work is to be executed and removing debries to a distance exc 250 metre but n exc 500 metre.
M & L for providing and applying rust inhibition coat system (in two coats) as per Manufacturer's instructions to exposed reinforcement after cleaning and removing scales and rust complete all as specified and directed by Engineer-in-charge.
M & L for providing and applying a bond coat (epoxy based bonding materials) to all exposed concrete surfaces all as per the manufacturer's instructions as specified and directed by Engineer-in-charge.
M & L for providing and applying latex polymer modified cement mortar in specified composition of system [i.e. cement 400 parts by weight, quartz sand 1600 parts by weight, polymer 60 parts by weight, water 120 parts by weight] to RCC surfaces all as per the Manufacturer's instructions and as directed by Engineer-in-charge. (NOTE :- Thickness of plaster/filling varies from 15 mm to 25 mm)
M&L treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors all as specified and directed.
Supply and fixing in repair stainless steel modular kitchen cabinet for kitchen cup/ saucer/ kitchen utensils, holder basket, corrosion resistance, seamless glosy finish, nickel chromium plated using 5mm dia. Wire/ SS perforated sheet assembled and fabricated as required size and finish, including telescopic drawer channel of stainless steel zinc finish ( silver colour ) of weight capacity minimum 35 kgs including necessary fixing arrangements hinges and stainless steel screws, with solid handle of stainless steel chromium plated of 200 mm 'D' shape including necessary fixing arrangements hinges and screws, ball catches with 8mm dia. steel ball and brass body and striking plate including letting in and necessary fixing arrangements hinges and stainless steel screws and veneered decorative plywood grade 1 (with BWR resin ) with decorative face veneers on one side as in drawers/ cupboards moulded as required including necessary fixing arrangements etc. and length of kitchen platform not exceeding 5m complete all as specified and directed. by Engr. - in - charge.
M&L for 60mm thick machine pressed precast concrete interlocking paver block reflective type coloured any shape and size confirming to IS 15658-2006 of M-35 grade, with grey cement and pigment including 25 mm thick grit cushioning below interlocking paver block complete all as specified and directed.
M& L for filleting in any position and to any shape in cement mortar 1:4 including all mitres, stops, including sectional area not exc. 25 Sqcm etc complete all as specified and directed.
S&F in repair steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, etc. Including gear operated type with bevel gear box and crank handle and safety lever locks mild steel with 4 levers for rolling shutter and ball bearing for rolling shutters etc. complete all as specified and directed by Engr. - in - charge
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixture and fittings such as switches, Ceiling rose, pendents, regulators, sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc . credit for above items should be made as per conditions separately.
Taking down ceiling fans any type/sweep 230 V AC and depositing to AGE E/M store complete all as specified and directed.
M&L for point wiring for light/fan/Bell with FRLSH cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.50 sqmm green in colour PVC copper conductor cable for earth continuity connected to common earth dolly incl PVC box surface type with PVC modular white cover plate for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc
All as per item No.127 above, but for one multipin 5 amps socket outlet on same board.with other switch complete all as specifed and directed.
All as per item No.127 above, but for one multipin 5 amps socket outlet on independent board with other switch complete all as specified and directed.
All as per item No.127 above, but for one light point controlled by 2, 2 way switch complete all as specified and directed.
All as per item No.127 above, but with 2.5 sqmm cable and 2.5 sqmm for earth continuity for multipin 15 amps socket outlet flush type on independent board complete all as specified and directed.
S & F ceiling rose, 3 phase PVC/polycarbonate isolated body, surface bakelite 65 x 50 mm, 3 terminal incl PVC square block complete all as specified and directed.
S & F lamp holder, PVC/polycarbonate type with back plate suitable for batten fitting incl PVC square block complete all as specified and directed.
S & F in repairs call bell ding dong AC, 230 Volts, single pole complete all as specified and directed.
S&F switch Modular, one way 6 amps, 1 module with suitable plate and cover complete as per existing make and model all as specified and directed.
S&F switch Modular, two way 6 amps, 1 module with suitable plate and cover complete as per existing make and model complete all as specified and directed.
S&F switch modular one way 16 amps, 1 module with suitable plate and cover complete as per existing make and model complete all as specified and directed.
S&F socket modular 6A, 2/3 pin combined 2 module with suitable plate and cover complete as per existing make and model all as specified and directed
S&F socket modular 6A/16A, 2/3 pin combined 2 module with suitable plate and cover complete as per existing make and model all as specified and directed
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
S&F modular bell push 6 Amps 1 module with suitable plate and cover complete as per existing make and model all as specified and directed.
S&F surface and wall mounted LED batten (LED tube light fitting 20W) with polycarbonate housing & integrated electronic driver alongwith LED tube 20 watt and 02 No PVC square blocks incl taking down old UNSV fitting. Make- Havells cat No. LUMILINEBS20WLED830SPCWH or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
S&F surface and wall mounted LED batten (LED tube light fitting 10W), extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver alongwith LED tube 10 watt and 02 Nos. PVC square blocks incl taking down old UNSV fitting. Make- Havells cat No ENDURALINEARNEOBS10WLED830SPCWH or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
S&F endura gugby NEON- IP 65 environmental friendly, ultra modern energy saving surfae mounted decorative oval bulk head edge lit LED luminaire comprising of high brightness LED 10 Watt incl taking down old UNSV fitting. Make- Havells cat No RUGBYNEONFT10WLED860SSYMTOPC or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
S&F building security LED light fitting 25 Watt , energy saving and environmental friendly long life LED fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 incl taking down old UNSV one. Make - Havells cat No ENDURAPEARLSL25WLED757SASYTOPC or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
S&F decorative wall light fittings (bracket light), CITY 3 made up of polycarbonate suitable for 10 watt LED lamp incl LED lamp incl taking down old UNSV one. Make- Havells cat No. LHDL06160099 or equivalent of Philips/ Bajaj/ Crompton Greaves/ Wipro/ Shakti/ Halonix/ Jaquar/ C & S / Bentec India Ltd./ Luker.
M&L for sub main wiring with two run of 6 sqmm single core multi stranded PVC insulated and unsheathed copper conductor (red for phase and black for neutral) of grade 1100 volt FRLSH cable in and including 1100 volt electrical grade PVC casing caping of desired colour not less than1.2 mm thick and 25 mm wide & 6 sqmm copper conductor cable PVC unsheathed green coloured for earthing with complete accessories duly connected with earth dolly complete all as specified and as directed incl taking down old unserviceable one.
All as per item No.147 above, but size 4 Sqmm two runs and with one run 4.0 sqmm FRLSH copper wire for earth continuity.
S&F in replacement enclosure, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amps, 240 volt incl taking down old UNSV one.
S&F in replacement MCB distribution board Double door SPN 240 volts 8 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls etc incl taking down old unserviceable one.
S&F in replacement MCB distribution board double door 240 volts 4 way with 200 amps rated bus bar and making good to disturbed surfaces of floors walls incl taking down old unserviceable one.
S & F MCB SP 6 to 32 Amps, 230 V AC complete all as specified and directed.
S & F MCB SPN 40 Amps, 230 V, AC complete all as specified and directed.
S & F MCB SPN 20 Amps, 230 V, AC complete all as specified and directed.
M & L for earthing complete with GI earth plate electrode of size 60 x 60 x 0.6 cms thick burried directly in ground vertically at a depth of not less than 2.25 Mtrs below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanised iton strip of 25 x 4 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, 40 mm dia GI tubing light grade protection pipe upto test point, 20 mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30x30 CM made of RCC 1:3:6 with suitable handle, angle iron frame of angle iron size 40 x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site all as specified in electric plate No.3 of SSR Part-I and directed by Engr-in-Charge.
All as per sl item No. 155 above, but galvanised iron wire 4mm dia as earthing lead.
M&L in replacement of LED lamp 9 watt complete all as specified and directed.
Supply and fix electric water heater vertical/horizontal type, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m deep and making good surface for laying /removing of cable all as specified and directed and getting out in:-
Soft/loose soil
Hard/dense soil
Returning, filling, in excavated soil in trenches, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removal of surplus excavated spoil (soil and soft/disintegratsed rock) to distance exc. 250 and not exc. 500 metre and despositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed
M & L for bituminous road cutting to a width of 45 cm and depth 50 cm for laying of pipe and UG cables and making good with PCC (1:3:6) type C1 (using 20mm grade stone aggregate) all as specified and directed.
Supply and laying GI tubing light grade of size 50mm dia bore for encasing cables for mechanical protection, laid under plinth/ floors/ paths culverts of fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/ sockets/ reducers/ saddles incl necessary threading/ drilling works all as specified and directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 1100 Volts grade in trenches/ passing through pipe/ fixing on walls, floors etc. incl connection with proper sizes lugs and gland, suyitable clamp of cross sectional area 3.5 core 70 sqmm in and including taking out old one all as specified and directed.
All as per item No. 165 above, but of the size 3.5 core 185 Sqmm
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 120 mm and inner dia 103 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed. Make : REX POLYEXTRUSION LTD or its equivalent as approved.
Supply & Laying of Telerex DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 76 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable incl couplers & bends complete all as specified and directed. Make : REX POLYEXTRUSION LTD or its equivalent as approved.
Supply, install, connect, test & commissioning factory made, dust/vermin, weather proof self ventilated, cubical of size 1.5m x 0.50m x 1.0m (Aps) with front made of and rear opening, hinged door for front and rear with MS angle iron frame 50 x 50 x 5mm for base support, 3.15mm thick CRCA sheet, LT panel board, (LT KIOSK), CPRI approved out door, cubical type, floor mounted, double door with neoprene gasket and locking arrangement with canopy including painting with powder coated on steel surfaces internally & externally and provision of two Nos. earth terminals on both sides, cable glands and PCC foundation with PCC 1:2:4, type B1 and 30cm all around the outer dimension of panel incluyding gap for insertion of cable having botton of panel at height of 60 cm above the ground lveel with cable entry glands to accommodate and including the following accessories:-
Copper bus bar rectangular 400 Amps full for phase and half for neutral and interconnection of MCCBs to Bus bar mounted on epoxy insulators with colour coding PVC sleeves.-01 job
MCCB 250 Amps, TPN, 415 Volts, 50 Hz , 36 KA - 01 No. (incoming)
MCCB 125 Amps, TPN, 415 Volts, 50 Hz, 36 KA - 04 Nos. (Outgoing)
MCB SPN 32/40A - Each 01
RYB LED phase Indicator Lamp set of three - 01 No.
Digital volt meter 0-500 Volt with selctor switch - 01 No.
Provision of cubicle to accommodate the above mentioned accessories.
Internal wiring of panel board, metering equipment with suitable size PVC insulated, unsheathed, 1100 V grade cable with multistranded copper conductor, including provision of lugs/thimbles on either ends of cable.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 sqm on plan and not exc. 1.5 m in depth and getting out in soft/disintegraded rock.
Returning, filling, including speading, levelling, watering and well ramming in layers not exc. 25 cm in soft/ disintegrated rock all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds, mitred/ stopped ends all as specified and directed.
BSK Construction
GGS Infra
N AND G CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .