| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC 218 D 1A JYANTIPUR NEAR SHYAM PIPE FACTORY SULEM SARAI PRAYAGRAJ UP | PRAYAGRAJ | PRAYAGRAJ | UP | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹30.7 L+₹35,045 (1.16%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹31.9 L+₹1.5 L (5.03%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹34.8 L+₹4.5 L (14.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹38.0 L+₹7.7 L (25.4%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
30 Sept 2024, 6:00 pmClosed
GE WEST PRAYAGRAJ
GE WEST PRAYAGRAJ PIN-211001
COMPREHENSIVE MAINTENANCE FOR INTERNAL AND EXTERNAL EM SERVICES OF DAD AREA AT NEW CANTT PRAYAGRAJ.
2024_MES_670563_1
8774/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NEW CANTT PRAYAGRAJ
As per tender Documents
8 documents required · 8 mandatory
₹500
GE WEST PRAYAGRAJ
₹90,000
Yes
24 Jan 2025
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Receiving complaints from Concern In charge of Internal section (Power House) lodged by the occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward KWH meter in respect of main distribution board having switch fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan/bell/light/Ceiling Fan, testing of Electronic meters or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, sunken boxes, junction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectified the fault with regard to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users. Note - (i) All spares required i.e. tube light any type, Choke any type, CFL,LED, starter, bipin holder, starter holder etc accessories, required for repairing will be paid under relevant supply only items of this schedule.
INSTRUCTIONS -(a) Attending complaint including taking down/refixing of LED light fittings and repair/ Replacement part (Labour cost ) and minor repair shall be measured against Srl item No 1 of Sch 'A' (b) Cost of material for replacement of new items shall be measured and paid separately under relevant items of sch 'A' against supply only here-in-after (Item No 2 to 34) (c) Penalty : Penalty for not attending complaints within stipulated time frame will be the liable to Rs 500.00 of per day for non attending the complaints multiple number of days of delay (d) Priority -1 (to be done within 8 hours from time of lodging complaint): No light, repair/replacement of switches, fan regulator, replacing burnt/damaged wiring, replacement of burnt MCBS and Main switch, voltage fluctuation, current leakage and replacement of tube lights. (e) Priority -2 (to be done within 72 hours from time of lodging complaint): Replacement of fittings and fixtures replacement of choke starter replacement of meter, replacement of DBs and Main DB, repair of earthling lead. (f) Priority -3 (to be done within 07 days from time of lodging complaint): Replacement of fittings and fixtures, Ceiling Fan, Call bell switch board, point wiring etc (g) Contractor shall employ suitable tradesman having sufficient experience of Electrician work with suitable helpers to rectify the internal electrification defects, breakdown current leakage, replacement of Electrical items, wiring work, electronic meter testing Etc. (h) The quantum of work under a complaint shall be comprised as the each Qtr/ complaint nature issued with unique docket No. (j) Documentation and monthly progress report of complaints shall be maintained by contractor by providing supervisor and maintenance team preferably two dedicated team for Officers and PBOR OTM ACCN. (k) All documents i.e. complaint register, complaint slip, gate pass and register for use signature must be provide by contractor from date commencement of the CA.
Supply only in replacement of switch piano flush button type 5 amps single pole one way complete all as specified and directed.
Supply only in replacement of switch piano flush button type 15 amps single pole one way complete all as specified and directed.
Supply only in replacement of socket outlet multipurpose 2/3 pin 5 amps flush button complete all as specified and directed.
Supply only in replacement of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
Supply only in replacement of 15 Amps switch socket combination, 240V complete all as specified and directed.
Supply only in replacement of ceiling fan regulator step type 240 Volt AC complete all as specified and directed.
Supply only in replacement bell push flush type 5 amps complete all as specified and directed.
Supply only in replacement ceiling rose surface type complete all as specified and directed.
Supply only in replacement angle/batten type lamp holder, PVC/Polycarbonate type with back plate complete all as specified and directed.
Supply only in replacement of call bell, ding dong type, AC, 230 V, single pole complete all as specified & directed.
Supply only in replacement single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp 'B' Curve. complete all as specified and directed.
Supply only in replacement of modular switch 1 way, 5/6 amps, 230V AC, one way complete all as specified & directed.
Supply only in replacement of modular socket out let 2-in-1, 3 pin, 15/16 amp flush type 2 module complete all as specified & directed.
Supply only in replacement of modular switch flush type 15/16 amps, 230V AC single pole two way complete all as specified & directed.
Supply only in replacement of modular socket out let 2-in-1, 3 pin, 5 & 16 amp flush type 2 module complete all as specified & directed.
Supply only in replacement of modular fan regulator, 5 stepped, electronic type, single phase, 120 watt, 1/2 module including connection complete all as specified & directed.
Supply only in replacement of Modular metal flush box of 12 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 8 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 6 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 4 module complete all as specified and directed.
Supply only in replacement of Modular metal flush box of 2 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 12 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 8 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 6 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 4 module complete all as specified and directed.
Supply only in replacement of Modular white plate cover with frame of 1/2 module complete all as specified and directed.
Supply only in replacement of Modular bell push flush type 6 amp, 1 module SP , 230V AC complete all as specified & directed.
Supply only in replacement MCB single pole, 6 to 32 amps rating, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement MCB single pole & Neutral, 40/63 amps rating, 240 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement MCB Triple pole & neutral 63/100 amp, 440 volts, 'B' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Supply only in replacement of PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where complete all as specified and directed.
Supply only in replacement of condenser of 2.5 MFD, 240 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
Supply only in replacement of condenser of 1.5 MFD, 240 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box of following sizes with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size along with new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
200 mm X 200 mm
100 mm X 100 mm
175 mm X 100 mm.
250 mm X 200 mm.
Supply and fixing in replacement of Recess swivel down light fitting 3 Watt 3000 K with pressure die-cast aluminium heat sink & clear PC as a cover in white powder coated finish with Independent electronic LED driver for low ceiling height applications complete all as specified and directed. Make Havells cat part no. LHEEAQPBIB1W003 or equivalent makes as specified in P.S.
Supply and fixing in replacement of 12 W LED down lighter Ultra slim decorative aluminium casted recess mounted round fixture in white finish with opal diffuser and separate electronic driver ,suitable for low depth ceiling complete all as specified and directed. Make Phillips Green Perform sleek cat Part No DN296B LED12S-6500 PSU W or equivalent makes as specified in P.S.
Supply and fixing in replacement of wall bracket Decorative, wall mounting, Shiny stainless steel base & glass opal paint finish including 1x10 watt LED bulb fixture With bulb base B22 complete all as specified and directed Make Havells cat Part No FLORETINE WL 1LS B22 SS. or equivalent makes as specified in P.S.
Supply and fixing in replacement of 36 W LED,6500K 2'x2' Panel Ultra slim recess mounted LED module with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for armstrong / grid ceiling complete all as specified and directed Make Philips Full glow RC380B LED36S-6500 G6 L60W60 PSU OD S1 or equivalent makes as specified in P.S.
Supply and fixing in replacement of 36 W LED 2'x2' Panel surface mounting with high brightness LED package and unique pattern de-glaring PP diffuser and PS LGP de-glaring diffuser sheet for glare free uniform light distribution suitable for surface /recess mounting applications as specified and directed. Make -Philips full glow surface mount complete all as specified and directed Make Philips Full glow SM367 LED36S-6500 G6 L54W54 PSU OD or equivalent makes as specified in P.S.
M&L for energy saver LED battan fitting 20 watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light complete all as specified and directed . Make Philips Essential Smart Bright BN170C LED20S-6500 PSU L120 or equivalent makes as specified in P.S.
M&L for energy saver LED fitting 25 watt, 230 Volts, Hanging Type , Smart Bright linear GEN 2 provides an Efficient, aesthetic 50mm extremely durable with aluminium extruded housing with suitability for stand alone & continuous version using joining kits for rapid installation. Suitable for applications like offices, including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified and directed . Make Philips Smart Bright linear GEN2 cat Part No SP170P LED25S-6500 PSU W5L113 OD WH or equivalent makes as specified in P.S.
S&F energy saver LED batten fitting 10 watt, 230 Volts, single tube mounting including with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection two core copper cable from ceiling rose to led light fitting complete all as specified and directed.
S & F in replacement of LED light fitting 1x9W/1x10W bulkhead luminaries including LED light driver holder connecting up three core flexible copper conductor cable of suitable size complete all as specified and directed. Make - Philips Cat Part No. BRP330 LED30 CW R5N PC PSU S1 V1 or equivalent makes as specified in P.S.
S & F in replacement of invertor Bulb 9 W , 230 volts. complete all as specified and directed. Make : Havells Cat part no :LED 9 W INVERTER BULB B22 CDL or equivalent makes as specified in P.S.
Supply ,fixing, testing and connecting LED Security light fittings 30 Watts , IP-65 cast aluminum housing in grey hammer tone stove enameled finish outside with electric connection of Electronic driver and LED panel to be suitable size of copper cable with base plate and complete all as specified and directed. Make - Philips Cat Part No. BRP330 LED30 CW R5N PC PSU S1 V1 equivalent makes as specified in P.S.
S&F sheet metal enclosure TPNL MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 125 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar IP 43 - IK 09 suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed.
S&F in replacement double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F in replacement, double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar IP 43 - IK 09 complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed.
S&F in replacement testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB SPN 16-32 Amps 'C curve' complete all as specified and directed.
S&F MCB TP 40-63 A 415V 'C curve' complete all as specified and directed.
S&F MCB TPN 40-63 Amps, 'C curve' complete all as specified and directed.
S&F MCCB 125 Amps, 4 Pole, 415V, 25KA complete all as specified and directed.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including conduit medium grade ISI marked not less than 19 mm dia/ Casing caping of 19-20 mm with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized standard sunken boxes as per standard as per manufacturer norms / Polycarbonate appropriate size for surface mounting with earth dolly and standard grid, crown and cover plate for fixing of switches / sockets, fan regulators, with captive screws including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing for one light, fan, call bell, 5Amp independent socket point controlled by one switch including cutting the chases and making good the surface by cement mortar 1:3 and for matching / finishing of new surfaces either by means of plaster of peris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed. Note -Sunken boxes, mounting grid, cover plate and switch sockets and regulator shall be paid and measured separately.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in existing conduit medium grade ISI marked any size /any type with earth dolly and standard grid, crown and cover plate for fixing of switches / sockets, fan regulators, with captive screws including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing for one light, fan, call bell, 5Amp independent socket point controlled by one switch including cutting the chases and making good the surface by cement mortar 1:3 and for matching / finishing of new surfaces either by means of plaster of peris/ Putty or distemper / colour wash with same existing colour surfaces complete all as specified and directed. Note -Sunken boxes, mounting grid, cover plate and switch sockets and regulator shall be paid and measured separately.
M&L Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 Sqmm drawn in MS/PVC conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ISI marked of size not less than 20 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed.
M&L Sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS/PVC conduit with 4 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including rigid PVC conduit ISI marked of size not less than 25 mm dia in concealed/surface wiring inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, sadles, pipe hooks etc fixed properly including taking down old unserviceable sub main wiring complete all as specified and directed.
M&L for cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring, sub main wiring etc and making good and plastering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 30cm girth complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC 1:3:6 type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main earthing lead upto 7.5 mtr including charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe complete all as specified and directed.
M & L for repairing of broken earthing pits chamber with PCC 1:3:6 type C-1 using 20 mm graded stone aggregate with 40 mm thick RCC cover of existing size 1:2:4 type B0 using 12.5 mm graded stone aggregate, reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe complete all as specified and directed.
Material and labour for new earthing pit with PCC 1:3:6 type C-1 using 20 mm graded stone aggregate chamber with 40 mm thick RCC cover 1:2:4 type B0, reinforced with 8 mm dia bar, 3 Nos. both way, funnel with wire mesh, water poring arrangement ,connecting main Earthing lead from Earthing pit to Test point /equipment all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed.
Supply and fixing in replacement of worn out wooden batten/ 20 mm dia PVC Conduit with Non Metallic Rigid PVC casing caping ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
Supply and fixing in replacement of worn out wooden batten/ 25 mm dia PVC Conduit with Non Metallic Rigid PVC casing caping ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
Excavation in trenches n.exceeding 1.50m wide and n.exc 1.50m depth for foundation etc or for shafts, walls, cess-pits, manholes, pier holes, cable etc n.exc. 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as specified & directed.
Returning, filling in including spreading, levelling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
M & L for sand cushioning with Ganga Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified & directed. Note:- Punned thickness shall be measured for payment.
M&L for factory made unreinforced precast concrete cable covers conforming to IS:5820, class HV type 1 size 300x180x40 mm for cable protection complete all as specified & directed.
Taking down old existing HT cable any size any location any conditions complete all as specified & directed.
M & L for HT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armourd cable (heavy duty) 11000 volt grade(earthed) with aluminium conductor having cross sectional area 120 Sq mm 3 core conforming to IS-7098 (Part-II -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified.
M & L for HT cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armourd cable (heavy duty) 11000 volt grade(earthed) with aluminium conductor having cross sectional area 95 Sq mm 3 core conforming to IS-7098 (Part-II -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified.
Taking up or down GI steel tubing and connections for cable protection of any size complete all as specified and directed.
M&L for 15 mm bore GI tubing 'light grade' with all necessary fittings laid in trenches/under road crossing/fixed on pole/wall/under floor including suitable mild steel FI clamps of required size complete all as specified & directed.
M&L for boring under road horizontally of size 40/50 mm bore using GI pipe for passing of cable in road/path in hard/soft/ loose soil including making good the disturbed surfaces complete all as specified and directed.
Disconnecting of OH line of ACSR conductor/GI earthing wire, opening of binding wires, jumper connections any size and restringing, tightening of conductor with suitable line vice, replacing all worn out jumper connection with suitable conductor, re-tightening and straightening all cross arms, insulators, clamps etc including replacement of all worn out nut bolts and washers complete all as specified and directed.
M & L for locating UG cable fault using microprocessor based fault locator suitable for low/medium and high voltage up to 11KV , XLPE/PVC/PILC of Al/Cu cables under trenches/RCC surface & on wall for finding OC/SC/Flashing faults with any one of the suitable methods Time domain reflect meter method (TDR)/Secondary impulse Method (SIM) /Impulse Current method (ICM)/decay Method to achieve pin point fault location up to 5 Km distance complete all as specified and directed. (Note : Quoted cost deemed to include all accessories , equipment's and labour cost)
M & L for preventive maintenance/ repairs to transformer step down 11 KV/0.43 KV in door/out door type of any make of 250 KVA - 630 KVA including cleaning the transformers externally thoroughly with lint free cloth, tightening the HT/LT terminal nuts, opening the top cover and replacing the worn out copper alloy nuts and tightening the earth terminals and conducting various tests as stipulated in the particular specification complete all as specified and directed.
M & L for filtration and dehydration of transformer oil on line by using streamline filtration plant the die electric strength to be brought to not less than 60 KV ( at 2.0mm gap for 1 minute) and testing the oil sample after dehydration complete all as specified and directed. Note: - (i) Test result before and after filtration to be recorded as per the sample provided by Engr-in-charge. (ii) The rate quoted deemed to be included for taking necessary connection and the connection to filtration plant from transformers and switchgear oil duly removing the inlet and outlet connections. (iii) For topping up transformer oil will be measured and paid separately under relevant items.
Supply and filling insulating oil (transformer oil) confirming to IS-315 having dielectric strength not less than 40 KV for topping up in 11/0.433 KV transformer complete all as specified and directed. Note:- Filling shall be done by on line filtration plant only. Make. Sarita/HP
M & L for Repair/Replacement of air breather any type upto 630 KVA transformer complete with filled silica gel complete all as specified and directed.
M&L for Replacement silica gel for up to 630 KVA transformer of any make type and capacity complete all as specified and directed.
M & L For Repair/Replacement of oil temperature gauge upto 400 KVA transformer complete all as specified and directed.
S & Fix in replacement of set of gasket such as top cover, conservator,bucholz relay, breather etc for transformer capacity upto 400 KVA complete all as specified and directed.
M & L for painting the transformer indoor/outdoor of capacity ranging from up to 630 KVA after preparation of surface and applying two coats of synthetic enamel (matching existing colour) paint on old steel surface and marking serial no, MES No, SM No, Date of installation etc complete all as specified and directed.
Supply and replacement of HT coils made out of super enamelled copper winding wires of same gauge and same no of turns as required as per transformer of 300 KVA to 400 KVA capacity including replacement of paper insulation ,insulating material and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 % pure and ISI Marked complete all as specified and directed.
Supply and replacement of LT coils made out of super enamelled copper winding wires of same gauge and same no of turns as required as per transformer of 300 KVA to 400 KVA capacity including replacement of paper insulation ,insulating material and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 %pure and ISI Marked complete all as specified and directed.
Disconnecting LT connection from the Transformer and transporting to workshop for repairs and shifting the transformer back to existing of 300 KVA to 400 KVA and connecting up complete (The rate included the rates fixing arrangements, any type of clamps, connection material as anything required at site) (Any type of damage of transformer while shifting will be the responsibility of contractor) complete all as specified and directed.
Supply and fixing in replacement of HT 11 KV bushing porcelain with copper alloy terminals for transformer of capacity upto 630 KVA including dismantling unserviceable complete all as specified and directed
All as per item No. 96 here-in-before but LT bushings complete all as specified and directed.
Supply and fix in replacement of burnt Brass Bush connecting rod for transformer up to 630 KVA and refixing new connecting rods with oil seal o-ring , nuts, washers etc complete all as specified and directed.
Material and labour for Painting to 2 pole structure consisting of two Nos steel tubular poles 11 m cross arms bracings supports etc. with two coats of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level/copping, remaining portion painting with two coats of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc complete all as specified and as directed.
Material and labour for Painting to 4 pole structure consisting of two Nos steel tubular poles 11 m cross arms bracings supports etc. with two coats of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level/copping, remaining portion painting with two coats of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc complete all as specified and as directed.
M & L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed
M & L for servicing of four pole and two pole structure complete including replacement of unserviceable GOD , jumpers with PVC 50 Sqmm aluminium cable single core , vice type connectors, bolts nuts washers connecting lugs/thimbles knife contacts, applying petroleum jelly to the moving as well as fixed contacts tightening all the connections for its smooth functioning and preparing the old painted surfaces of the structure such as poles, cross arms, bracing and supports clamps back plates complete painting of two coats of anticorrosive aluminium paint over a coat of red oxide zinc chrome primer and providing yellow and black paint from the ground level all as directed at site by Engineer-in-charge. Note: - No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule.
Supply and spread crushed stone aggregate of size 40 to 90 mm grade all as specified and directed.
Supply and fix in repair/replacement of switches air break gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism worked from ground level for current rating upto 200 Amps 11000 volts complete all as specified and directed
M & L for Disc type composite/polymer insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 145mm height 225mm dia 11000 volts grade including taking down old unserviceable insulator complete all as specified and directed.
M & L for pin type composite/polymer insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 150mm height 150mm dia 11000 volts grade including taking down old unserviceable insulator complete all as specified and directed.
Supply and fix lightening arrestor non linear type suitable for HT 11 KV installation out door use complete with all fittings transmission class discharge 65 Kilo Amps including taking down the unserviceable complete all as specified and directed.
Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, with accessories complete all as specified in electrical plate No 1 of SSR Part-1 complete all as specified and directed by the Engr-in-Charge. (loop type insulator, excavation and concrete measured separately).
Cutting removing the vegetation growth and surface dressing all around the installation yard including two pole structure area, around power house, substation (external only) to keep always installation clean and tidy complete all as specified and directed. Note : All the installation yards/area shall be kept clean through out the contract period by repeatedly removing the grass/seeds as many times as required depending on the growth of the grass and measurement will be made only once.
Supply & fix in replacement of drop out fuses capacity 20 Amps to 40 Amps complete all as specified and directed. Make: Jayapuria /Bussmann or Equivalent
M & L for Repair/Maintenance , cleaning, dusting and servicing Vacuum Circuit Breaker, HT 11 KV,50 Hz , 630 Amp indoor switch gear panel by Grounding of complete panel live parts, thorough cleaning, visual checking, tightness checking, and servicing of breaker panel including breaker carriage along with associated mechanism , metering panel, bushbar/cable chambers, motorised spring charging mechanism , DC shunt trip/close coils, operation counter, manual spring charging mechanism , relays, meters , indicators , heater coil, aux supply SMPS , replacing of worn out parts and fuses , applying petroleum jelly to moving and fixed mechanical parts for its smooth functioning complete all as specified and directed.
M & L for Repair/Maintenance ,cleaning, dusting and servicing, for the smooth functioning of 3 way compact RMU, HT 11 KV , 630 Amp, 3 phase 50 cycle by Grounding of complete panel live parts, thorough cleaning, visual checking, tightness checking, and servicing of breaker panel including breaker carriage along with associated mechanism , metering panel, bushbar/cable chambers , self powered over current and earth fault relay, T-off SF6 circuit breaker module , mechanical fault/on/off indicator etc including refilling of SF6 gas and replacing worn out parts when required etc and confirming smooth reliable operation of RMU unit complete all as specified and directed.
Supply and replacement of LED light Red, Blue, Yellow & green for 110 Volts for HT 11 KV panel all including taking down the unserviceable complete all as specified and directed.
Supply and fix in Replacement of Push Button with 1 NO + 1NC on existing HT VCB Panel complete all as specified and directed. Make : L &T /Seimens/Schnider or Equiv
Supply and fix in Replacement of Rotary switch for Local / Remote / Neutral / trip / Close function on existing HT VCB Panel complete all as specified and directed. Make : L &T /Seimens/Schnider or Equiv
Supply and fix in Replacement of Digital Multifuction meter PT/CT (0-110v)/(0-1/5A) operated for measuring votage / Ampere / Power factor / Frequency etc on existing HT VCB panel complete all as specified and directed. Make : Schnider/L&T/AE/MECO/SELEC or Equivalent
Supply and fix in Replacement of Panel space Heaters 80-120 watts coil element AC 230 Volt Input suitable for HT VCB panel of any make fixed inside with suitable clamps , bolts and nuts complete including necessary wiring cable connection complete all as specified and directed.
Supply and fix in Replacement of Thermostat switch for controlling the space Heaters temperature settings AC 230 Volt Input suitable for HT VCB panel of any make fixed inside with suitable clamps , bolts and nuts complete including necessary wiring cable connection with control toggle ON-OFF switch - 01 No complete all as specified and directed.
Supply and fix in replacement of damaged HT breaker cluster contacts male / female / Isolating / Moving / Fixed Contacts 630/400 amps for VCB/RMU type breaker complete all as specified and directed. Make Kirloskar /ABB or Equivalent
Supply and Replacement of closing coil complete with all accessories suitable for HT 11 KV VCB 400/630 Amps complete including taking down the unserviceable all as directed. Make: Suitable Make of Kirloskar/ABB
Supply and Replacement of tripping coil complete with all accessories suitable for HT 11 KV VCB 400/630 Amps including taking down the unserviceable complete all as directed. Make: Suitable Make of Kirloskar/ABB
Supply and replacement of HT 11 KV VCB 400/630 Amps epoxy spout insulator including taking down the unserviceable. Make: of Kirloskar/ABB
Supply and replacement of CAM wheel assembly suitable for VCB of existing make HT 11 KV,400/630 Amps capacity complete with all accessories as specified and as directed. Make: Suitable Make of Kirloskar/ABB
Supply and replacement of spring charging motor suitable for VCB of make Schnider HT 11 KV, 630 Amps capacity complete with all assembly/accessories as specified and as directed. Make: Suitable Make of Kirloskar/ABB
Supply and Replacement of spring charging gear assembly with all accessories suitable for HT 11 KV VCB 400/630 Amps complete including taking down the unserviceable all as directed. Make: Suitable Make of Kirloskar/ABB
Supply and Replacement of catch/ latchet assembly complete with all accessories suitable for HT 11 KV VCB 400/ 630 Amps complete including taking down the unserviceable complete all as specified and directed. Make: Suitable Make of Kirloskar/ABB
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq mm to 95 sq mm including taking down the unserviceable complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm to 185 sq mm including taking down the unserviceable complete all as specified and directed.
Taking down old U/S strip of any description and any size complete all as specified and directed.
M & L for laying earth continuity conductor GI Strip 32 x 6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for direct/loop earthing with proper PVC/Porcelain insulator etc complete all as specified and directed.
M & L for earthing complete with Galvanized Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level, connected to and including GI iron strip of size 32x6 mm flat by means of GI bolts, nuts, and washers, protected by 40mm bore GI light grade ISI marked pipe upto and including test points. Earthing plate shall be surrounded by alternate layers 15cm thick of charcoal or coke and common salt all around bottom and top, 20mm dia GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C2 (using 20mm graded crushed store aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling in and disposal of surplus soil to a distance not exceed ing 50 M, pit cover 40 mm thick made with RCC (1:2:4) type B-1 (using 20mm graded crushed store aggregate) including TMT reinforcement 80 mm dia @ 75 mm C/C both way, MS handle of 12 mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and as shown in electrical plate No-3 of SSR Part-I and all as directed. Note :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and earthing strip upto test point from top of the earth plate and further upto body of electrical equipment shall be including in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engr-in-charge. No extra payment shall be made on this account.
M & L for Testing of earthing resistance of existing earth pits using calibrated 3/4 wire digital Earth resistance meter and contractor is responsible to arrange calibrated earth resistance meter and also maintain earth resistance register with user signature to be submitted to concerned office complete all as specified and directed.
M & L for rubber matting one side chequered and other side plain 19 mm thick insulated for 11000 Volts ISI Marked in standard size 2m x 1m including taking down the unserviceable complete all as specified and directed.
M&L danger notice board/plate of 1.6mm thick mild steel sheet vitreous enameled white with letter, figures and conventional skull and bones in signal red colour and fixed with MS clamps, nuts and bolts of approved size of HT 25 x 20 cm size complete all as specified and directed. .
Repairing/ welding of leaking fins / body of transformer and making the same leak proof complete all as specified and directed.
Supply & fix in replacement of Tinned copper flexible jumper 200/400A rating for Gang operated /Air break switch assembly with proper nuts,bolts and applying non corrosive petroleum jelly complete all as specified and directed.
Schedule of Credit (MINUS) Rs. 150404.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. ] This amount shall be automatically deducted to arrive at tendered sum
ARADHYA ENTERPRISES (BID ID -3108470)
DINESH ELECTRICALS (BID ID -3120867)
PITAMBARI TRADERS (BID ID -3106856)
M/S Aarav Construction (BID ID -3106408)
NEXT POWER ENTERPRISES (BID ID -3107279)
M/S BHAGIRATHI ENTERPRISES (BID ID -3107505)
VIKAS INDIA ENTERPRISES (BID ID -3122485)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .