Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹50.3 L+₹8.0 L (18.9%)Admitted-Finance | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Ajayshwar Singh Rana L2 | kiran electrical and hardware centre L1 |
|---|---|---|---|---|---|
| 1.00 | M & L for Taking down of ceiling fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of ceiling fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 2,200 | Each Job | 80 ₹1,76,000 Lowest | 100 ₹2,20,000 |
| 2.00 | M & L for Taking down of wall fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of wall fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 220 | Each Job | 80 ₹17,600 Lowest | 100 ₹22,000 |
| 3.00 | M & L for Taking down of Exhaust fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,clamps ,nuts and bolts including refixing and reconnection of ex fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 500 | Each Job | 80 ₹40,000 Lowest | 100 ₹50,000 |
| 4.00 | M & L for comprehensive maintenance and overhauling of Geyser 25/50 Ltrs of any make and size including following works complete all as specified and directed.
(a) Checking proper working of geysers.
(b) Checking of PVC pipe/ safety valve/ heating element/ flange/ thermostat including replacement of unseviceable part
(c) Checking of unserviceable bottom cover plate/ PVC pipe/ heating element/ thermostat / indicating lamp.
(d) Cleaning of geyser 25/50 Ltr . | 600 | Each Job | 250 ₹1,50,000 | 100 ₹60,000 Lowest |
| 5.00Note for Sr 1 to 4 Above : 1.Contractor has to depute two team (comprising of 01x electrician & 01x helper in each Team) daily from commencement of work to till completion of work for day to day maintenance/ execution of work as per CA, who will report to JE E/M in MES YARD under AGE E/M . 2. Unserviceable parts to be measured & paid seperately under relevant item of Sch A. 3.All Tools & Plants incl transportation for shifting of geyser/Ceiling Fan/Exhaust Fan from user's accn to yard for repair/deposit and ladder provided to electrician at site by the contractor. | |||||
| 6.00 | M & L for Opening of ceiling fan of any make and any sweep for repair/ replacement of unserviceable parts complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items. | 800 | Each Job | 50 ₹40,000 Lowest | 80 ₹64,000 |
| 7.00 | M & L for Opening of Exhaust fan of any make and upto 450 mm sweep size for repair/ replacement of unserviceable parts complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items. | 350 | Each Job | 50 ₹17,500 Lowest | 80 ₹28,000 |
| 8.00 | Supply only ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 450 | Each | 200 ₹90,000 | 80 ₹36,000 Lowest |
| 9.00 | Supply only ball bearing of 6202/115 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 450 | Each | 200 ₹90,000 | 95 ₹42,750 Lowest |
| 10.00 | Supply only ball bearing of 6203/117 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 300 | Each | 200 ₹60,000 | 110 ₹33,000 Lowest |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
7 Sept 2026, 6:00 pmClosed
GE, GE (P) No 1 Jabalpur
GE (P) NO 1, Ridge Road, Jabalpur-482001
REPAIR MAINT OF CEILING FAN EXHAUST FAN GEYSER AND DAY TO DAY MAINTENANCE OF AGE E AND M UNDER GE P NO 1 JABALPUR
2026_MES_782678_1
8632/KH/E8
Open Tender
Civil Works
Item Rate
180 days
GE (P) NO 1, Ridge Road
D, b(i)
7 documents required · 7 mandatory
₹500
GE (P) No 1 Jabalpur
₹1 L
15 Sept 2026
4 Aug 2026
14 Sept 2026
4 Aug 2026
7 Sept 2026
18 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for Taking down of ceiling fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of ceiling fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 2,200 | Each Job | - | - |
| 2 | M & L for Taking down of wall fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,rubber reel ,clamps ,nuts and bolts including refixing and reconnection of wall fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 220 | Each Job | - | - |
| 3 | M & L for Taking down of Exhaust fan of any make and any sweep for checking of serviceablility ,loose electrical connection ,loose hanging etc and providing clean lubricating Oil/ grease,replacement of split pin,clamps ,nuts and bolts including refixing and reconnection of ex fan with required size of 3 core copper conductor complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be replaced at site (to be measured & paid seperately in respective items)
(2) Unsv Fan to be deposited to MES Yard/Store (E/M )
(3) Serviceable Fans needs requirement of parts not mentioned above and not repairable at site to be deposited to MES store/Yard or any Local shop/contractor Workshop to be deposited for defect rectification and refixing on site.. | 500 | Each Job | - | - |
| 4 | M & L for comprehensive maintenance and overhauling of Geyser 25/50 Ltrs of any make and size including following works complete all as specified and directed.
(a) Checking proper working of geysers.
(b) Checking of PVC pipe/ safety valve/ heating element/ flange/ thermostat including replacement of unseviceable part
(c) Checking of unserviceable bottom cover plate/ PVC pipe/ heating element/ thermostat / indicating lamp.
(d) Cleaning of geyser 25/50 Ltr . | 600 | Each Job | - | - |
| 6 | M & L for Opening of ceiling fan of any make and any sweep for repair/ replacement of unserviceable parts complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items. | 800 | Each Job | - | - |
| 7 | M & L for Opening of Exhaust fan of any make and upto 450 mm sweep size for repair/ replacement of unserviceable parts complete all as specified and directed.
Note: (1) Repair/ replacement of unserviceable parts to be measured & paid seperately in respective items. | 350 | Each Job | - | - |
| 8 | Supply only ball bearing of 6201/120 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 450 | Each | - | - |
| 9 | Supply only ball bearing of 6202/115 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 450 | Each | - | - |
| 10 | Supply only ball bearing of 6203/117 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 300 | Each | - | - |
| 11 | Supply only ball bearing of 6204/118 for ceiling fan/ exhaust fan of any size and make complete all as specified and directed. | 300 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
8632TenderDocuments.pdf
Tender Documents • 1.02 MB
BOQ_876902.xls
BOQ • 0.47 MB
8632corr01.pdf
PDF • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .