| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.3 L+₹1.8 L (5.76%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹36.0 L+₹4.5 L (14.3%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹38.8 L+₹7.3 L (23.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | Vee kay construction L4 | sachinder singh L2 | JYOTI ENTERPRISES L3 | CREATIVE CONSTRUCTION L1 |
|---|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | |||||||
| 1.10 | Taking down chowkats or frames exc 1.50 Sqm but n.exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. | 13 | Each | 170 ₹2,210 | 150 ₹1,950 Lowest | 155 ₹2,015 | 200 ₹2,600 |
| 2.00 | M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base, foundation, filling in mass concrete etc. including demolition of concrete in ground floors and pavings (unreinforced) nexc 15 cm thickness (below or above ground level) complete all as specified and directed. | 16 | Cum | 3,500 ₹56,000 | 2,200 ₹35,200 Lowest | 2,700 ₹43,200 | 3,300 ₹52,800 |
| 3.00 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 including demolition old bricks work build any type of mortar complete all as specified and directed. | 19 | Cum | 5,300 ₹1,00,700 | 4,700 ₹89,300 Lowest | 5,200 ₹98,800 | 7,000 ₹1,33,000 |
| 4.00 | M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed. | 2 | Cum | 5,300 ₹10,600 | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,000 ₹8,000 Lowest |
| 5.00 | M&L for 75mm thick, cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with and including bitumen and sand 1:3 by weight including demolition of concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level), complete all as specified and directed. | 15 | Sqm | 350 ₹5,250 | 280 ₹4,200 | 300 ₹4,500 | 220 ₹3,300 Lowest |
| 6.00 | M&L for vitrified glazed, light shade tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exceeding 1.00 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including demolition of old tiles work laid any type of screed bed complete all as specified and directed. | 160 | Sqm | 980 ₹1,56,800 | 900 ₹1,44,000 Lowest | 1,100 ₹1,76,000 | 1,050 ₹1,68,000 |
| 7.00 | M&L for vitrified glazed light shade tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm but not exceeding 0.36 sqm as in vertical surfaces such as skirting, risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with including demolition of old tiles work laided any type of screed bed complete all as specified and directed. | 10 | Sqm | 1,025 ₹10,250 | 855 ₹8,550 Lowest | 900 ₹9,000 | 1,050 ₹10,500 |
| 8.00 | M&L for vitrified glazed, light shade, tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm but not exceeding 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including demolition of old tiles work laided any type of screed bed/mortar complete all as specified and directed. | 200 | Sqm | 890 ₹1,78,000 | 790 ₹1,58,000 Lowest | 800 ₹1,60,000 | 880 ₹1,76,000 |
| 9.00 | M&L for screed bed or beding layer of mortar 15mm thick for laying floor finish in CM 1:6 complete all as specified and directed. | 360 | Sqm | 98 ₹35,280 | 120 ₹43,200 | 155 ₹55,800 | 40 ₹14,400 Lowest |
Tender Value
₹38.9 L
EMD Value
₹77,700
Closing Date
15 Jul 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
SPECIAL REPAIR OF DINNING SPACE FOR CANDIDATES MESS AT BLDG NO P 317 AND SPECIAL REPAIR TO BLDG NO T 16 GURUDWARA SARVA DHARMA STHAL AT SI LINES UNDER GE BHOPAL
2025_MES_715659_1
8404/E8
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹77,700
Yes
26 Sept 2025
19 Jun 2025
17 Jul 2025
19 Jun 2025
15 Jul 2025
3 Jul 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking down chowkats or frames exc 1.50 Sqm but n.exc 4 Sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base, foundation, filling in mass concrete etc. including demolition of concrete in ground floors and pavings (unreinforced) nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 including demolition old bricks work build any type of mortar complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed.
M&L for 75mm thick, cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with and including bitumen and sand 1:3 by weight including demolition of concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level), complete all as specified and directed.
M&L for vitrified glazed, light shade tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exceeding 1.00 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including demolition of old tiles work laid any type of screed bed complete all as specified and directed.
M&L for vitrified glazed light shade tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm but not exceeding 0.36 sqm as in vertical surfaces such as skirting, risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with including demolition of old tiles work laided any type of screed bed complete all as specified and directed.
M&L for vitrified glazed, light shade, tiles 8 to 10 mm thick (square/rectangular) polished, area of each tiles exc 0.18 sqm but not exceeding 0.36 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including demolition of old tiles work laided any type of screed bed/mortar complete all as specified and directed.
M&L for screed bed or beding layer of mortar 15mm thick for laying floor finish in CM 1:6 complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surface back coat to wall for tile in CM 1:4 complete all as specified and directed.
S&F in repairs 12mm thick toughfen glass for door, partitions etc similar work etc with stainless steel handle, locking arrangement and with hinges in approved shape and design complete all as specified and directed.
S&F of galvanised cold rolled steel section framed work size 600x600mm, grid size 24x38x0.60mm Tee (bottom precoated) and 24x24x0.50mm thick wall angle galvanised cold rolled steel section including expansions fasteners as in ceiling including dismantling wall and ceiling boards of any description fixed in any position, any thickness including cover fillets, complete all as specified and directed.
S&F of 5 mm thick PVC panels in ceiling of approved design by Engr-in-Charge PVC material having a minimum density of 600 kg/m3. The panel dimension will be 600 x 600 mm, PVC ceiling shall be fixed with T grade bracket system, for PVC board is resistant to the spread off lames in the class A category with the properties of being termite/borer proof, water/moisture proof, and fire retardant, complete all as specified and directed. Note:- Payment of frame will be paid separately.
S&F of solid PVC wall lining consisting of 5mm thick but wood grain printed PVC sheet used instead of plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F of 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
M&L for one coat of 1 mm thick wall care putty on walls/ceiling complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of exterior weather proof water base emulsion paint over and incl a coat white cement based putty (where ever required), complete all as specified and directed. Note :- Exterior acrylic emulsion paint used only and work should be carried out by approved manufacturer's.
M&L for preparation of old decorated surfaces of wall including brooming, scraping down, smoke spot, moss, efflorescent salts, trading oil, grasy spots and stopping nails marks and applying two coat of exterior weather proof water base emulsion paint on wall complete all as specified and directed.
S&F of pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick (AZ-150) of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified including dismantling asbestos cement (Corrugated, semi corrugated, etc) sheets including ridges in roof covering complete all as specified and directed.
All as ser item No 19 here-in-before but plain sheeting 0.5mm thick, in ridges including dismantling asbestos cement (Corrugated, semi-corrugated, etc) sheets including ridges in roof covering complete all as specified and directed.
S&F of for steel work in tubular trusses including special shaped washer etc. using ERW or induction butt welded tubes conforming to I.S.1161- 1979 grade St.-240 including dismantling of structural steel work including doors, gates etc complete all as specified and directed.
M&L for preparation of new or previouly untreated surface of steel and iron surface of over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old painted surfaces of Steel and iron based materials exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies, 35mm thick (measured solid), using 1:2:4, type B0 using 20mm graded stone aggregate including all mouldings but excluding frame including dismantling of pre-cast concrete lovres and jallies complete all as specified and directed.
S&F in repairs PVC(SWR) 110mm pipes, single socketed in any length with rubber rings joints laid in trenches or in floors including taking down eaves gutters and rain water pipes (any size or pattern) complete all as specified and directed.
S&F in repairs PVC(SWR) 110 mm bend complete all as specified and directed.
M&L for granite work 18-20 mm thick (of any type/ colour) (table rubbed and polished/ moulding) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to mactch with shade or granite including demolition complete all as specified and directed.
Taking down chowkats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
S&F of 15 mm bore GI tubing, medium grade, galvanised with all fitting and fixed to walls and ceilings or laid in floors including taking up or down 15mm bore steel tubing and connections complete all as specified and directed.
S&F of 20 mm bore GI tubing, medium grade, galvanised with all fitting and fixed to walls and ceilings or laid in floors including taking up or down 15mm bore steel tubing and connections complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
S&F in repairs factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ceosetory windows and other Frames/Chowkhat of size 50x100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with mild steel hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed.
S&F in repairs factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shuitter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (Wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having maximum density of 650 kg/cum and screw withdrawl strength of 1800 N (Face) & 900 N (Edge) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S S screws complete all as specified and directed. Note : SS butt hinges and necessary SS screws shall be measured and paid separetely.
S&F of butt hinges 100mm size butt hinges medium weight cold rolled mild steel complete all as specified and directed.
S&F of 150 mm long aluminium handles, cast type, anodised fixed to shutters complete all as specified and directed.
S&F of 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 300mm long ordinary mild steel rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing creed bed or bedding layer of mortar 20 mm thick for laying floor finish in CM 1:4 including demolition old flooring work laided any type of mortar complete all as specified and directed.
All as per ser item no 38 here-in-before but for dados and similar work on skirting 20-25mm thick kota stone.
S&F of powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat, channel etc for fixing etc. complete all as specified and directed.
S&F of 4.0mm thick plain sheet glass ordinary quality n.exc 0.50 sqm in each pane complete all as specified and directed.
S&F of stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm fixed to frames complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan (padestal pattern), white (excluding flushing costern and flush pipe) complete all as specified and directed.
S&F in repairs PVC low level flushing cistern of 10 Litres, PVC valveless, syphonic action type, flushing cistern, white, with inlet, ball valve, float and handle including brackets with all internal fittings including flush pipe and fixing to supply pipe complete all as specified and directed.
S&F in repairs plastic water closet seat cover, any colour, closed pattern with flat bottom and mild steel chromium plated for aluminised hinging device complete all as specified and directed.
S&F in repairs 15 m, fancy type, swan neck taps, cast copper alloy (rotational), with capstain head, chromium plated screw down high pressure, with long shanks and fly-nuts screwed for iron pipes and fixed complete including necessary all GI fittings as approved complete all as specified and directed.
S&F in repairs 15 mm pillar taps cast copper alloy, with capstan head, chromium plated screw down high pressure, with or without lettered HOT or Cold with long shanks and fly-nuts screwed for iron pipes and fixed in repairs including necessary small GI fittings complete all as specified and directed.
S&F in repairs vitreous china wash hand basin white flat back of size 550 x 400mm excluding tap but including brackets/CP brass 32mm waste coupling complete all as specified and directed.
S&F in repairs to CP health faucet suitable for 15mm bore with connecting pieces including all necessary fittings and accessories complete all as specified and directed.
S&F of TMT bars 6mm to 8mm dia cut to length bent to shape as required including cranking bending and binding with mild steel wire aunealed not less than 0.9mm dia complete all as specified and directed.
M&L for RCC (Nominal mix) 1:2:4 type B-0 using 12.5 mm graded stone aggregate for slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like and the like including demolition of reinforced cement concrete of any description and in any position complete all as specified and directed. Note : Reinforcement shall be measured and paid separately.
M&L for preparation of new or untreated surface of steel and iron surface of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete as specified and directed.
M&L for 15 mm thick rendering in cm 1:4 on fair aces of bricks walls surface finished even and smooth without using extra cement including water proofing compound including taking down cement plaster on brick or wall/ceiling etc. complete all as specified and directed. Note: Water proofing compound measured and paid seperately.
M&L for glazed ceramic tiles in vertical surfaces 350x250x7mm/ 450x350x7mm thick, set and jointed in neat cement slurry and pointed with white or coloured cement to match including demolition of old tiles complete all as specified and directed.
S&F in repairs 25mm stainless steel drepary curtain rod decorative type including curtain fancy type including bracket and nobs complete all as specified and directed.
M&L for complete removal of old decorated surface of wall and applying two coat of interior plastic emulsion paint white/coloured over and including one coat of white cement based putty (where it is required) complete all as specified and directed.
M&L for grinding and polishing kota/marble/terazoo/mosaic flooring complete all as specified and directed.
M&L for elegant ceiling tile made of perforated cement fiber composite of 595x595/295x1195/595x1195x5mm covered with absorptive micro fiber coating on the front side acoustics fiber on the back side, water resistance, fire resistant absorption coefficient upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti-sag and installed on T24 grid system of 0.6mm thick main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm center to center and secondary cross 'T' of length 600mm web minimum 35mm inter locked, wire support for main T to be taken at every 1200mm length wise and 600mm width wise, with a backing of 50mm 1000 GSM thick absorb wool tested as per fire resistant IS:15061-2002 for excellent results including dismantling of wall and ceiling boards of any description fixed in any position, any thickness including cover fillets complete all as specified and directed. Make: HIMALYAN ACOUSTICS
M&L for complete removal of old decorated surface of wall and applying two coat of exterior weather proof water base emulsion paint white/coloured over and including one coat of white cement based putty (where it is required) complete all as specified and directed.
S&F of hand rails, half round or other stock section of core for wooden hand rail straight portion drilled and counter sunk for balusters running bars for door balusters nosing to steps including embedding in concrete and screwing etc, wind tie for roof including securing bolts, posts and struts in fencing including cutting tops to shapes as directed, drilling holes, notching for wire, etc: flat iron fillets (for securing wiremesh etc.) including all necessary drilling, bolting or riveting, etc. and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling of water tanks of exc. 500 litres but n.exc 1000 litre capacity and removing to store complete all as specified and directed.
S&F of 1000 ltrs capacity rotational moulded polyethylene water storage tanks 3 layers (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 75 mm thick using 40mm graded stone aggregate as in plinth protection including demolition of concrete in ground floors and pavings (unreinforced) n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down carefully copper/aluminium point wiring concealed/casing caping (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls etc complete all as specified and directed.
Dismantling/taking down of unserviceable old existing service /submain wire of any size complete all as specified and directed.
Dismantling/taking down of unserviceable distribution boards with MCBs complete all as specified and directed.
M&L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed flexible conductor FRLS cables 1.5 sqmm as per IS 694:2010, ISI marked annealed multistranded copper conductor drawn through and including medium machenical strees PVC conduit as per IS:9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistaranded copper conductor FR-LS cable as continuous earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed. Note: Cost of cutting chase and making good shall be included in the quated rates.
All as per item No 67 here-in-before but one socket outlet 5 pin 5/6 Amps on independent board controlled by one, one way switch.
All as per item No 67 here-in-before but one socket outlet 5 pin 5/6 Amps on same board with other one, one way switch.
All as per item No. 67 here-in-before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire.
All as per item No 67 here-in-before but for socket outlet, 15/16 Amps on independent board with 4.0 Sqmm size cable and 4.0 Sqmm for continuty earth wire connected to common earth dolly.
S&F of modular switch, one way, 6 Amp one module, 240 volts with cover plate complete all as specified and directed.
S&F of modular switch, one way, 16 Amp one module, 240 volts with cover plate complete all as specified and directed.
S&F of modular socket outlet, 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, with cover plate controlled by one switch complete all as specified and directed.
S&F of modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts, with cover plate controlled by one switch complete all as specified and directed.
S&F of sheet metal enclosures (IP-43 protection) with socket plug top and MCB's with two pin and earth plug and socket complete with one single pole MCB 240 V grade 25/20 Amp complete all as specified and directed.
S&F of ceiling rose 3 terminals 65x25 mm dia polycarbonate isolated complete all as specified and directed.
S&F of modular fan regulator complete all as specified and directed.
S&F in replacement enviroment friendly building security light fitting made up of pressure die cast alluminium housing with high efficient 30 Watt LED as lighting source and pc over having top opening separate driver compartment with IP-66 Protection and including IK 07 protection suitable galvanized iron pipe "light grade" brackets 1.2 mtr length bent to shape to obtain required shape including clamps, nuts/bolts/washers etc connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core copper wire for connected light complete all as specified and directed.
S&F in replacement of MCB DB, TPN 4 way (IP-43 protection) vertical/horizontal type with single/three phase outgoing with provision of MCBs/MCCB as incomer 415 volt with 200 amps rated bus bar complete all as specified and directed.
S&F in replcement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series complete all as specified and directed.
All as per item No 81 here-in-before but MCB SPN 100 amps complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 using 20mm graded stone aggregate for earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long complete all as specified and directed. Note:- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately.
S&F in repairs LED ultra slim decorative aluminium casted edge ceiling light, recessed mounting LED 2 x 2, luminaire 36 watt, white in colour with all accessories internally pre-wired and including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core complete all as specified and directed.
S&F in repairs 8/10 watt LED path light (BAMBOO LED BOLLARD) new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP-65 luminaire for diffused lighting with high power LED as light source complete all as specified and directed. Make- Cat part No-BAMBOOBLS8WLED830PSYMTOPC of Havells or equivqlent Bajaj/ C&G as approved by GE.
S&F of non metalic PVC conduit ISI marked, medium grade, of size 20mm dia complete all as specified and directed.
S&F of PVC insulated PVC sheathed, flexible circular cable 3 core, 1.5 Sqmm strandered copper conductor AC, 230 V complete all as specified and directed.
S&F of ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) without remote controller complete all as specified and directed.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 1.5 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 1.5 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i) Wiring shall be done as per approved colour code in IE rule. (ii) Two runs of 1.5 sqmm cable, one run of 1.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and green for single phase circuits) with three single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 2.5 sqmm nominal cross section area and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 2.5 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring shall be done as per approved colour code in IE rule. (ii) Two runs of 2.5 sqmm cable, one run of 2.5 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Black and Green for single phase circuits) with three single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 4 sqmm nominal cross section area and drawing into 25mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 4 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring shall be done as per approved colour code in IE rule. (ii) Two runs of 4 sqmm cable, one run of 4 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
M&L for sub main wiring with approved colour coding as per IS (Red, Yellow, Blue, Black and Green for three phase circuits) with five single core PVC insulated ISI marked FRLS cable 1100V unsheathed with stranded copper conductor of 6 sqmm nominal cross section area and drawing into 25mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and PVC insulated stranded copper conductor of 6 sqmm nominal cross section area as earth wire complete all as specified and directed. Note : (i)Wiring shall be done as per approved colour code in IE rule. (ii) Two runs of 6 sqmm cable, one run of 6 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length.
S&F of lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F of 12 watt LED bulb cool day light, 230/240V, AC complete all as specified and directed.
S&F of LED tube light fitting bright 20 watt, slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fitting connector complete all as specified and directed.
Taking down and refixing of LED tube light fitting bright 18/20 Watt, slim elegant design and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector complete all as specified and directed.
S&F in replacement of DB, SPN, 12 way, double door for MCB, 240 volt with 200 amps rated bus bar complete all as specified and directed.
S&F of factory made epoxy powder coated distribution board TP & N 4 ways (VTPN MCCB DB) and space for MCCB as incomer with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated neutral Bar, insulated busbar assembly, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts complete all as specified and directed. NOTE:- MCCB shall be measured and paid seperatly.
S&F of MCCB 100 Amp, 3 Pole, breaking capacity 36 KA with electrical connections by appropriate size of copper lugs complete all as specified and directed.
S&F in replcement MCB 6-32 amps, 10 KA, SP 240 volt, 'C' series complete all as specified and directed.
S&F in replcement MCB 40 amps, 10 KA, SP 240 volt, 'C' series complete all as specified and directed.
S&F in replcement MCB 32-40 amps, 10 KA, SPN 240 volt, 'C' series complete all as specified and directed.
All as per item No 102 here-in-before but MCB SPN 63 amps.
Taking down carefully ceiling fans of any size from its position and refixing on its position in serviceable condition by petty repairing, cleaning, reasing, painting as existing colour properly complete all as specified and directed.
Taking down carefully 1.5/2 TR ACs any type of any size from its position with all precaution and refixing on its original position in fully serviceable condition by gas charging and petty repairing properly upto the satisfaction complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 47273.00
sachinder singh (BID ID -3351469)
JYOTI ENTERPRISES (BID ID -3351785)
Vee kay construction (BID ID -3351463)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .