Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC SHOP NO 107 MOHAN SINGH PLACE NEW DELHI 110001 | NEW DELHI | DELHI | 110001 | ₹6.8 L | L1 | Accepted-AOC work order has been awarded |
| 2 | L2₹7.2 L+₹36,961.17 (5.40%)Rejected-Finance A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹7.2 L+₹36,961.17 (5.40%) | L2 | Rejected-Finance Not L1 |
| 3 | L3₹9.0 L+₹2.1 L (31.4%)Rejected-Finance | ₹9.0 L+₹2.1 L (31.4%) | L3 | Rejected-Finance Not L1 |
Tender Value
₹10.2 L
EMD Value
₹21,550
Closing Date
25 Mar 2026, 1:00 pmClosed
EEE-I
MUNICIPAL CORPORATION OF DELHI Office of the Executive Engineer (Elect)-I Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Improvement of Park lights in various Municipal parks in AC-57 under Shahdara south Zone.
2026_MCD_272343_1
EEE-I/2025-26/28.1
Open Tender
Electrical Works
Percentage
60 days
work
please refer to tender documents
4 documents required · 4 mandatory
₹590
₹21,550
10 Jul 2026
20 Mar 2026
25 Mar 2026
20 Mar 2026
25 Mar 2026
20 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1LED Street light fixture, powder coated pressure die cast aluminum body (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP 66,IK-10, CRI >80, under voltage and over voltage protection, EMI EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). 36 watt | |||||
| 2Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. | |||||
| 3Providing and fixing 6 SWG dia GI Wire on surface or in recessed for loop earthing as required. | |||||
| 4Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a)Upto 35 sq. mm | |||||
| 5Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. (a)Upto 35 sq. mm | |||||
| 6Supplying and Laying of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.) | |||||
| 7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) | |||||
| 8Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq .mm | |||||
| 9Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) Single pole | |||||
| 10Supply and Fixing of 32mm dia X 1 m Long GI Pipe(Medium Class) Bracket for mounting of Fluorescent/HPMV/HPSC street light fitting on pole including bending the pipe to the required shape, 2 nos. of 25mmX6mm flat iron clamp with nuts, bolts & washer, painting the flat iron with primer and finsih paint etc as required. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
condition1.pdf
Tender Documents • 0.60 MB
BOQ_317716.xls
BOQ • 0.29 MB
viewsbd.pdf
Additional Documents • 15.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .