Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.4 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹49.8 L+₹79,860 (1.63%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹52.3 L+₹3.3 L (6.70%)Rejected-Finance MB NO 180 MG ROAD JUNGLIGHAT PORT BLAIR 744 103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹52.3 L+₹3.3 L (6.80%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹54.1 L+₹5.1 L (10.4%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
26 Jul 2022, 6:00 pmClosed
GE(I)866 EWS CARNICOBAR
GE(I)866 EWS CARNICOBAR C/O 99APO 913866
REPAIR / MAINTANANCE OF CAPTIVE POWER HOUSE DG SETS OF VARIOUS CAPACITY INCLUDING PERIODICAL MAINTENANCE OF DG SETS AT AF STATION CARNICOBAR
2022_MES_533604_1
8604/22-23/E8
Open Tender
Civil Works
Item Rate
335 days
Area under GE(I)866 EWS CARNICOBAR
As per Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹90,000
Yes
26 Sept 2022
25 Jun 2022
1 Aug 2022
25 Jun 2022
26 Jul 2022
13 Jul 2022
Amount
Quarterly comprehensive and preventive maintenance of under mentioned DG Set (Engine, Alternator) along with its AMF panel through qualified OEM service engineer as per manufacturer’s/OEM standard instruction for DV2/KV series following DG sets :- (a) DG Set (500 KVA) KOEL - 02 Nos (b) DG Set (400 KVA) KOEL - 01 Nos (c) DG Set (600 KVA) KOEL - 01 No
Note :- (i) The complete Quarterly servicing, maintenance of captive DG set to be carried out during the contract period with minimum 1 Kirloskar Senior Engineer (OEM) having minimum 5 year experience in maintenance of DG set. (ii) All consumable store required for captive power DG Set will be paid separately except cotton waste, grease and any minor parts to ensure Engine and Alternator Operational (iii) The stationery and registers required should be provided for the period of contract. (iv) Any minor repair occurred to be cleared within 24 hrs and major repair will be cleared within one week through OEM auth service engineer/technician. (v) During contract period all DG set should be kept serviceable except during maintenance period and major repair. (vi) Service engineer's deployed to carry out Quarterly servicing, maintenance in DG set. Cost of transportation, Travel pass, boarding and messing be included in the quoted rates. (vii) The maintenance work should be carried out through qualified engineer as and when required. (viii) Spare parts shall be measured and paid under respective items
Note (Contd....) (ix) 1st service through OEM shall be carried out by the contractor for all DG Sets, within 15 days of commencement of work and last service shall be carried out before 30 days of completion of contract period. (x) Service engineer shall carry out all cheeks of DG set components and submit the service report to Engr in charge in duplicate. Also suggest the spare parts reqd to be changed on or before next servicing, so that the spare can be made available on site within time to avoid any major break down. If contractor fail to carry out Quarterly service within the time frame penalty of Rs. 10,000/- shall be recovered. (xi) DG Set (500 KVA) KOEL - 02 Nos, DG Set (400 KVA) KOEL - 01 No, DG Set (600 KVA) KOEL - 01 No, Measured as one Job.
All as per item No 1 above but Cummins make DG set of capacity 1010 KVA . Note: Read Note same as 1.01 and 1.02
Half yearly comprehensive and preventive maintenance of synchronization panel comprising of under mentioned DG Set (Engine, Alternator) along with its AMF panel through qualified OEM service engineer as per manufacturer’s/OEM standard instruction :- (a) DG Set 500 KVA KOEL - 02 Nos (b) DG Set 400 KVA KOEL - 01 Nos (c) DG Set 600 KVA KOEL - 01 No (d) DG Set 1010 KVA Cummins - 01 No
Note :- (i) The complete Half yearly servicing, maintenance of synchronization panel at captive DG set to be carried out during the contract period with minimum 2 Senior Engineer of (OEM)/manufacturer's having minimum 5 year experience. (ii) All consumable store required for synchronization panel at captive power DG Set will be including in quoted rate. (iii) The stationery and registers required should be provided for the period of contract. (iv) Any minor repair occurred to be cleared within 24 hrs and major repair will be cleared within one week through OEM auth service engineer/technician. (v) During contract period synchronization panel should be kept serviceable except during maintenance period and major repair. (vi) Service engineer's deployed to carry out Half yearly servicing, maintenance in synchronization panel. Cost of transportation, Travel pass, boarding and messing be included in the quoted rates. (vii) The maintenance work should be carried out through qualified engineer as and when required. (viii) 1st service through OEM shall be carried out by the contractor for synchronization panel of all DG Sets, within 15 days of commencement of work and Second service shall be carried out before 30 days of completion of contract period.
Note (Contd....) (ix) Service engineer shall carry out all cheeks of synchronization panel components and submit the service report to Engr in charge in duplicate. Also suggest the spare parts reqd to be changed on or before next servicing, so that the spare can be made available on site within time to avoid any major breck down. If contractor fail to carry out Half yearly service within the time frame penalty of Rs. 10,000/- shall be recovered. Note - (i) All DG set of captive power house will be synchronized, if any minor material is required for synchronization the cost will be borne by the contractor no extra payment will be given to contractor by the department. (ii) 500 KVA DG set No II should be synchronized if any material is required for synchronization the cost will be borne by the contractor no extra payment will be given to contractor by the department.
Supply and Fixing in replacement Fan clutch Assembly (radiator fan pully) Part No DVO.076.40.0.00 for 500 KVA KOEL DG Sets as specified and directed by Engr-in-Charge .
Supply and Fixing in replacement Permanent Magnet Generator Assembly (PMG) for any type of DG set of capacity 400 to 1010 KVA of any make in captive power house as specified and directed by Engr-in-Charge .
Rewinding of Permanent Magnet Generator Assembly (PMG) for KOEL/Cummins DG set of capacity 400 KVA to 1010 KVA including taking down burnt winding wire from PMG field and rewinding with and including same dual coated supper enamelled copper conductor wire with same size/gauge including replacement of fibre glass tape, sleavs stote wedge, terminal lead and PMG leads etc, varnishing of complete winding with H class insulation level and drying the varnish, including transportation of unserviceable PMG from site to workshop and return back for installation it on original position/location after rewinding from workshop (Rate is deemed to be inclusive of transportation, T&P and man power) complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Exciter stator coil for KOEL DG set of capacity 400 KVA to 600 KVA complete all as specified and directed by Engineer in charge .
Rewinding of Exciter stator/coil for Cummins DG set of capacity 1010 KVA including taking down burnt winding wire from Exciter field and rewinding with and including same dual coated supper enamelled copper conductor wire with same size/gauge including replacement of fibre glass tape, sleavs stote wedge, terminal lead and exicter leads etc, varnishing of complete winding with H class insulation level and drying the varnish, including transportation of unserviceable Exciter from site to workshop and return back for installation it on original position/location after rewinding from workshop (Rate is deemed to be inclusive of transportation, T&P and man power) complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Turbocharger for KOEL/Cummins make DG set of capacity 400 / 500 / 600 KVA complete all as specified and directed by Engineer in charge .
Supply and Fixing in replacement Turbocharger for KOEL/Cummins make DG set of capacity 1010 KVA complete all as specified and directed by Engineer in charge .
Supply and Filing of Engine Oil for Kirlosker Engine (type ‘K’ Oil of supper grade SAE 15w40) or as specified by manufacturer for topping up or replacement of lubricating oils during periodical maintenance/daily checks complete all as specified and directed by Engineer in charge.
Supply and Filing of Engine Oil for Cummins Engine (Supper grade SAE 15W40) or as specified by manufacturer for topping up or replacement of lubricating oils during periodical maintenance/daily checks complete all as specified and directed by Engineer in charge.
Supply and Fixing coolant premixer DFC 50 as specified by manufacturer (OEM) complete all as specified and directed by Engineer in charge.
Disconnecting Alternator from all electric connection from DG sets of capacity 400 KVA to 1010 KVA, Lowering / getting out electrically & mechanically carefully indoor / outdoor and Transportation of unserviceable Alternator of any make and type of capacity from 400 KVA to 1010 KVA from Captive power house Carnicobar to main land i.e. Chennai workshop and return back to Carnicobar for installation its on original position/location after rewinding from Chennai workshop (Rate is deemed to be inclusive of transportation, T&P and man power) complete all as specified and directed . Note: (i)The Contractor shall submit Transportation bills before claiming payment through RAR/FB. (ii) Before dispatch of Alternator to Workshop for rewinding, old wiring shall be cut / destroyed in presence of Engr-in-Charge.
Rewinding of KOEL make DG set alternator of capacity 400 KVA to 500 KVA DG sets alternator of any make any type, separate the stator and rotor assembly, taking down burnt winding wire from stator, exciter field and rewinding stator with and including same dual coated supper enamelled copper conductor with same size/gauge including replacement of fibre glass tape, sleavs stote wedge, terminal lead and exicter leads etc, varnishing of complete winding with H class insulation level and drying the varnish and reassembling the alternator complete all as directed by Engineer in charge. Note: (i) The Contractor shall undertake the warranty till Defect Liability Period (ii) 12 Hrs testing after successfully repaired shall be carried out for 12 Hrs i.e. for (2 Hrs on 25%, 2 Hrs on 50%, 2 Hrs on 75% & 4 Hrs on 100 % Load) (iii) Quoted rate shall deemed to be inclusive of all nothing extra shall be paid.
Rewinding of KOEL/Cummins make DG set alternator of capacity 600 KVA to 1010 KVA DG sets alternator of any make any type, separate the stator and rotor assembly, taking down burnt winding wire from stator, exciter field and rewinding stator with and including same dual coated supper enamelled copper conductor with same size/gauge including replacement of fibre glass tape, sleavs stote wedge, terminal lead and exicter leads etc, varnishing of complete winding with H class insulation level and drying the varnish and reassembling the alternator complete all as directed by Engineer in charge. Note: (i) The Contractor shall undertake the warranty till Defect Liability Period. (ii) 12 Hrs testing after successfully repaired shall be carried out for 12 Hrs i.e. for (2 Hrs on 25%, 2 Hrs on 50%, 2 Hrs on 75% & 4 Hrs on 100 % Load) (iii) Quoted rate shall deemed to be inclusive of all nothing extra shall be paid.
Supply and Fixing Lub oil filter suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 014.27 for DV 2 series engine complete all as directed by Engineer in charge.
Supply and Fixing Lub oil filter suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 014.11 for DV 2 Series engine all as specified and directed.
Supply and Fixing Fuel filter catridge suitable for 600/500 KVA DG Set of KOEL Part No. DVO. 020.03.0.00. for DV2 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Lub oil filter suitable for 1010 KVA DG Set of Cummins Part No. 3879488 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Lub oil filter suitable for 1010 KVA DG Set of Cummins Part No. 3238204 Series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Fuel filter catridge suitable for 1010 KVA DG Set of Cummins Part No. 3238493 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Fuel filter suitable for 400 KVA DG Sets of KOEL Part No. KVO. 110.01.0.00 all as specified and directed complete all as specified and directed by Engineer in charge.
Supply and Fixing Fuel filter element suitable for 400 KVA DG sets of KOEL Part No. KV2. 506.20.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Lub oil filter suitable for 400 KVA DG Sets of KOEL Part No. KVO. 043.03.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Water Separator filter for DV2 series engine Part No DV8.040.24.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Water Separator filter mounting assembly complete for DV2 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Water Separator filter for 1010 KVA Cummins DG set series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Water Separator with complete assembly Part No. KV2.506.05.0.00 for 400 KVA engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Primary Element for DV2 series engine 600 KVA Part No F6.986.11.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Safety Element for DV 2 series engine 600 KVA Part No F6.986.12.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Primary Element for DV2 series engine 500 KVA Part No F6.404.28.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Safety Element for DV 2 series engine 500 KVA Part No F6.404.27.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Primary Element for Cummins series engine 1010 KVA Part No 4020557 all as specified and directed.
Supply and Fixing Air Cleaner Safety Element for Cummins series engine 1010 KVA Part No 4020552 complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner Primary Element Part No. KV8.505.02.0.00 for 400 KVA engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Air Cleaner safety Element Part No. KV8.505.03.0.00 for 400 KVA engine complete all as specified and directed by Engineer in charge.
Supply and Fixing Seal ring for fuel pre filter Part No. KV2.506.09.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing Seal Ring for fuel pre filter for 1010 KVA Cummins DG Set complete all as specified and directed by Engineer in charge.
Supply and Fixing V Belt wrapped 1170 DVO.016.23.0.00 suitable for engine pully to charging alternator 600/500 KVA DV2 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing V Belt Ribbed Part No 4958411 suitable for engine pully to charging alternator 1010 KVA series engine all as specified and directed.
Supply and Fixing Fan Belt Part No 5413006 suitable for 1010 KVA series engine all as specified and directed.
Supply and Fixing in replacement V Belt Cogged B X 58 DVO.016.08.0.00 suitable for engine pully to radiator fan pully/water pump 600/500 KVA DV 2 series engine all as specified and directed.
Supply and Fixing in replacement V Belt Cogged suitable for engine pully to charging alternator 400 KVA KV series engine all as specified and directed.
Supply and Fixing in replacement V Belt Cogged suitable for engine pully to radiator fan pully/water pump 400 KVA KV series engine all as specified and directed.
Supply and Fixing in replacement automatic voltage regulator having terminal of PQR , F1,F2 and R1 R2 suitable for 500/400 KVA alternator as per standard excitation voltage with variable triacs for control the voltage, stability etc Make - Altex
Supply and Fixing in replacement of self starter motor DC 24 volts suitable for any make and any type of DG sets of capacity 400 KVA to 1010 KVA. Make - Lucas, CD TVS,Boosh or equivalent
Repair of self starter motor DC 24 volts complete suitable for any make and any type of DG sets of capacity 400 KVA to 500 KVA complete all as specified and directed by Engineer in charge.
All as per item no 48.00 here in before for 600 KVA DG set.
All as per item no 48.00 here in before for 1010 KVA DG set.
Supply and Fixing in replacement charging alternator 24 volts DC suitable for 1500 RPM engine with voltage control regulator of any make and any type of DG sets of capacity 400 KVA to 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Hose TC Drain KVO.047.19.0.00 all as specified and directed.
Supply and Fixing in replacement Hose rubber inter cooler to engine suitable for DV2 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement hose rubber engine to radiator suitable for DV2 series engine complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement flex hose for vent F6.669.09.0.00 complete all as specified and directed by Engineer in charge.
Supply and fixing MPU Magnetic Pickup unit / Magnetic Sensor unit for Cummins DG set of capacity 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and fixing MPU Magnetic Pickup unit / Magnetic Sensor unit for KOEL engine of capacity 400 KVA to 600 KVA DG Set complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement intake manifold DVO.023.09.0.00 complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Fuel pipe for tank to filter with necessary fixing arrangement complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement automatic voltage regulator /AUX105 having terminal of PQR , F1,F2 and R1 R2, Q1 Q2, A1 A2 suitable for 600KVA/1010 KVA alternator as per standard excitation voltage 67 volts with variable triacs for control the voltage, stability etc Model TVAR 30 or TVAR 15 Make - Kirloskar Green/Cummins
Supply and Fixing in replacement (Display) Generator Control Unit KG 545 or latest model as per manufacture instruction for DG set of capacity 400 KVA to 600 KVA complete all as specified and directed by Engineer in charge.
Repair , testing and commissioning of complete Cummins make Control panel board PC 3.3 including following parameters for 1010 KVA DG set comprising of following as under :-
(a) The control system is an integrated microprocessor based generator control system providing voltage regulation, engine protection alternator protection, operator interface and isochronous governing (i) Amp Sentry - Integral amp sentry protection which provides a full range of alternator protection function suitable to alternator provided (ii) Power management - control function provides battery monitoring, testing and smart starting control system (iii) Advanced control methology - Three phase sensing FET based full wave rectified voltage regulation and PWM output for stable operation with all type of loads (iv) Communication interface - control comes standard with PCC net and module interface (v) Regulation compliant - Prototype tested UL CSA and CE compliant (vi) Service - Inpower PC based service tool for detailed diagnostics setup, data logging and fault simulation and reliable operations in harsh environment with independent of PC/Laptop for setting up (vii) Operator panel feature - display the utility data / AC bus data having 320 x 240 pixels graphic LED back light LCD with bar graph for displaying electrical parameters, auto manual start stop, fault reset and lamp test/panel lamp switches , alpha numeric display with push buttons, LED lamps including genset running remote start, not in auto, common shutdown, common warning, manual run mode, auto mode and stop.
Note (Contd....) (viii) Paralleling control functions Digital frequency synchronization and voltage matching, Isochronous KW and KVAR, load sharing controls, drop KW and KVAR, Sync check, extended paralleling, Digital power transfer control (AMF) provide load transfer, operation in open or closed transition or soft (ramping) transfer mode. (ix) Alternator data - line to neutral and line to line AC volts, three phase AC current, Frequency, KW, KVAR, power factor KVA (3 phase and total) (x) Engine data DC voltage, Engine speed, lub oil pressure, coolant temperature / low level(xi) Other data Genset model, start attempts, starts, running hors, KW hours, load profile, Fault history, data logging and fault simulation (xii) Digital governing - Integrated digital electronic isochronous governor, temperature dynamic governing (xiii) Digital voltage regulation - Integrated digital electronic voltage regulator, three phase four wire line to line sensing, configurable torque matching (xiv) AC protection - Over current and short circuit shutdown, over current warning, single/three phase fault regulation, over and under voltage shutdown, over and under frequency shutdown, overload warning with alarm, Reverse power shutdown, field over load
Note (Contd....) (xv) Engine protection - Battery voltage monitoring, protection, over speed shutdown, low oil pressure warning and shutdown, high coolant temperature warning / shutdown, low coolant level warning / shutdown, low coolant temperature warning, fail to start, cranking lock out, Sensor failure indication, low fuel warning or shut down (xvi) AUX 105 replaced with New AUX 105 (xvii) PC3300 replaced with new PC3300. Note : Engineer's deployed to carry out testing and commissioning of Control panel PC 3.3 Cost of transportation, Tribal pass, boarding and messing be included in the quoted rates
Supply and Fixing in replacement Battery Cable Assembly 70 Sq mm for DG sets of capacity 400 KVA to 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Water Pump with assembly and Pulley for any make and any type of DG sets of capacity 400 KVA to 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Thermostat element with Gasket and Housing for any make and any type of DG sets of capacity 400 KVA to 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Lube Oil press Sensor LLOP for any make and any type of DG sets of capacity 400 KVA to 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Fuel pipe Return for any make and any type of DG sets of capacity 400 KVA / 500 / 600 / 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Rectifier Kit Diode for Alternator 24 Volt 45 amp of any make and any type of DG sets of capacity 400 / 500 / 600 / 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement coolant temperature sensor of any make and any type of DG sets of capacity 400 / 500 / 600 / 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Fuel Pump of any make and any type of DG sets of capacity 400 / 500 / 600 / 1010 KVA complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement Fuel Injector assembly of any make and any type of DG sets of capacity 400 / 500 / 600 /1010 KVA complete all as specified and directed by Engineer in charge.
M&L for hot air blower 1000/2000 Watts adjustable compact design suitable for working on single phase 220V, 50 Hz Ac supply Make- Bajaj/Orient
Supply and Fixing in replacement CT of capacity 1000/5 A for 600 KVA DG set (Alternator) for KOEL make DG set complete all as specified and directed by Engineer in charge.
Supply and Fixing in replacement complete control wiring including cable housing for any type of DG set of any make of capacity 400 / 500 / 600 / 1010 KVA DG set in Captive power house complete all as specified and directed by Engineer in charge.
Supply and fixing in replacement Halogen light fittings of capacity 1000 watts with lamp complete with comprising of cast aluminium housing a pair of aluminium reflector and highly transparent clear acrylic cover hinged to canopy at one end and fixed / mounting in DG sets complete all as specified and directed by Engineer in charge.
DHAKSHNA MOORTHY AND SON
Kathir Marketing Services
ISLAND SALES ENTERPRISES
M/s Karbhagam Sales Agency
MGP Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .