Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC 15 BOH ROAD DEFENCE ENCLAVE AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.7 L+₹2.6 L (6.42%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹45.9 L+₹5.8 L (14.5%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹47.9 L+₹7.8 L (19.5%)Rejected-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹48.2 L+₹8.1 L (20.3%)Rejected-Finance 11 A KUTCHERY ROAD BALUGANJ AGRA 282001 UP | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance BEING L5 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
14 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF THANE
The Garrison Engineer (AF) Thane,Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR TO BUILDINGS AND INSTALATIONS POST CYCLONE NISARGA AT SITE R AFS UNDER GE AF THANE
2021_MES_455620_2
8134/E8
Open Tender
Civil Works
Item Rate
330 days
THANE
AS PER NEW NIT UPLOADED ALONG WITH TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF THANE
₹78,000
Yes
7 Mar 2022
8 Oct 2021
15 Dec 2021
8 Oct 2021
14 Dec 2021
2 Dec 2021
8 Oct 2021 - 2 Dec 2021
60 days
Amount
Taking down chowkhats or frames not exc 1.5 sqm with shutters (without taking off shutters from the frames) , complete all as specified and directed by Engr-in-charge.
Taking down door Chowkhats alongwith shutters Exc 1.5 sqm but not exc 4 sqm each , complete all as specified and directed by Engr-in-charge.
Dismentling Asbestos cement corrugated or semi corrugated sheet in roof covering , complete all as specified and directed by Engr-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engr-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws , complete all as specified and directed by Engr-in-charge.
M&L powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified and complete of as per standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws ,complete all as specified and directed by Engr-in-charge.
S&F aluminium anodized grill of 4.75 x 7.75 mm, size of opening 10cm, size of mesh RG 103 (as per royal grill) with aluminium channel `F' angle 20mmx15mm fixed to aluminium frame ,complete all as specified and directed by Engr-in-charge.
M&L machine cut cudappa stone slab 15-20mm thick over cement screed base as in jambs and soffits of lintel laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing over 10mm thick in CM 1:3 as backing coat to receive cudappa stone slab , complete all as specified and directed by Engr-in-charge.
M&L machine cut cudappa stone slab 30-40mm thick over cement screed base as in jambs and soffits of lintel laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and polishing over 10mm thick in CM 1:3 as backing coat to receive cudappa stone slab , complete all as specified and directed by Engr-in-charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples ,complete all as specified and directed by Engr-in-charge.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.5 sqm ,complete all as specified and directed by Engr-in-charge.
S&F sheet glass ordinary quality 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm each pane ,complete all as specified and directed by Engr-in-charge
S&F figured glass, pin-head type 4.00mm thick and glazing with oil putty in squares n.exc 0.5 sqm each pane ,complete all as specified and directed by Engr-in-charge.
Demolition of lime concrete in ground floors and pavings exc 15 cm thickness above ground floors including old water proofing treatment of any description and in any position , complete all as specified and directed by Engr-in-charge.
S & F 1.25 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. , complete all as specified and directed by Engr-in-charge.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and Brushing neat cement slurry with 3 kg of cement per sqm , complete all as specified and directed by Engr-in-charge.
Removing existing water proofing treatment where so ever exist (except concrete padding) and removing debris/rubbish off the site , complete all as specified and directed by Engr-in-charge.
M&L for PCC type B-0 1:2:4 (using 12.5mm graded stone aggregate) as levelling course to finished even and smooth with using extra cement, complete all as specified and directed by Engr-in-charge.
M&L for rendering 10mm thick on CM (1:3) on concrete roof top and chajjas surface finished even and smooth to get uniform level surface for laying of membrane treatement,with using water proofing compound , complete all as specified and directed by Engr-in-charge.
Material and labour for water proofing treatment with APP based standard membrane minimum 3mm thick over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (MAKE : TEXSA/BITUMAT/BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
Dismantling water tank capacity exc 500 and n exc 1000 ltr and removing to store , complete all as specified and directed by Engr-in-charge.
S&F 500 Ltr Rotational moulded polyethene water storage tank triple layered (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I , complete all as specified and directed by Engr-in-charge.
S&F 20mm Ball brass valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms) , complete all as specified and directed by Engr-in-charge.
S&F, in repair ,quarter turn stop valves 15 mm, cast copper alloy ,screwed down high pressure with crutch or butter fly handle ,screwed both ends for iron pipe or for union , complete all as specified and directed by Engr-in-charge.
S&F, in repair ,quarter turn stop valves 20 mm, cast copper alloy ,screwed down high pressure with crutch or butter fly handle ,screwed both ends for iron pipe or for union , complete all as specified and directed by Engr-in-charge.
Taking up or down 15 mm dia steel tubing and connections, including cleaning for refixing or removal to store ,complete all as specified and as directed by Engineer-in-charge.
Taking up or down 20 mm dia steel tubing and connections, including cleaning for refixing or removal to store ,complete all as specified and as directed by Engineer-in-charge.
M&L for 15mm bore medium grade, G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors, complete all as specified and directed by Engr-in-charge.
M&L for 20mm bore medium grade ,G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors , complete all as specified and directed by Engr-in-charge.
Refixing old GI steel tubing for 15 mm bore of pipe with and including necessary fitting & connections in new or old position (walls, ceiling, floors etc) , complete all as specified and directed by Engr-in-charge.
Refixing old GI steel tubing for 20 mm bore of pipe with and including necessary fitting& connections in new or old position (walls, ceiling, floors etc) , complete all as specified and directed by Engr-in-charge.
Demolition of cement Concrete (unreinforced) of any description and in any position not otherwise specifically provided , complete all as specified and directed by Engr-in-charge.
Demolition of cement Concrete (reinforced) of any description and in any position not otherwise specifically provided , complete all as specified and directed by Engr-in-charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles , complete all as specified and directed by Engr-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m n.exc 4 sqm each ,Complete all as specified and as directed by Engineer-In-Charge.
M&L for 15mm thick mineral board fine fissured in true horizontal level of size 600mm x 600 mm as in false ceiling hot dipped galvanized steel section, exposed surfaces with precoated capping, main centre to centre of size 24mm x 32mm having 0.27 mm gauge at every 1200mm centre to centre and wall angle of size 19mm x 19mm having 0.35 mm gauge fixed to the periphery of the wall . The above grid is suspended at every 1200mm c/c on both directions using 3 mm thick prestrightened GI wire, laying etc. ,Complete all as specified and as directed by Engineer-In-Charge.
S&F in repair Bands, straps,supports or stays for rainwater pipes, hold fasts etc complete all as specified and conforming to Fe-290 Gde-E-165 etc. ,complete all as specified and as directed by Engineer-in-Charge.
S & F Aluminium door handles 150 mm long ,cast type, anodised ,complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 10mm thick (1:6) cement plaster on fair faces of brick work or concrete surfaces even and smooth without using extra cement,complete all as specified and as directed by Engineer-in-Charge.
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) ,complete all as specified and as directed by Engineer-in-Charge.
M&L for rendering 5mm thick in cement mortar 1:3 cement plaster on newly plastered surface of brick work or concrete surfaces even and smooth without using extra cement ,complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of, plastered or unplastered new surfaces of ceiling and applying two coat of white wash , complete all as specified and as directed by Engr-in-charge.
M&L for preparation of, plastered or unplastered old surfaces of ceiling and applying two coat of white wash , complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new steel surface of any description over 10cm width or girth not otherwisw described and apply two coat of synthetic enamel paint over a coat of red oxide primer , complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new or previously untreated surface of wood & wood based surfaces over 10cm width & applying two coats of synthetic enamel paint ((ordinary tint) (eachcoat)) over a coat of red oxide as a priming coat , complete all as specified and directed by Engr-in-charge.
Supply only integral water proofing liquid admixture for concrete and mortar,complete all as specified and as directed by Engr-in-charge.(Make :CONPLAST X421IC of Fosroc /SIKA No 1 of SIKA/equivalent brand of PIDILITE)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing),including removing serviceable tiles and rubbish off the premises ,complete all as specified and as directed by Engr-in-charge.
M&L Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. et and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed or bedding layer in CM 1:4 for receiving floor finished,complete all as specified and directed by Engr-in-charge.
S&F 200mm long ,aluminium anodized barrel tower bolt extruded section ,complete all as specified and directed by Engr-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp 300 mm long, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy ,complete all as specified and directed by Engr-in-charge. Make:-Classic/Shalimar
M&L for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces ,complete all as specified and directed by Engr-in-charge.
M&L for preparation of Plastered or unplastered new surface of concrete or brick surfaces with and including two coat of distemper oil emulsion over a coat of alkali resistant primer, ,complete all as specified and directed by Engr-in-charge.
M&Lfor preparation of Plastered or unplastered old surface of concrete or brick surfaces with and including two coat of distemper oil emulsion over a coat of primer complete ,complete all as specified and directed by Engr-in-charge.
M&L powder coated aluminium Door/ window/ sliding window / Ventilator / partition frames and shutters using standard aluminium powder coated sections including necessary joining cleats, glazing clips, rubber packing anodised aluminium snap beading, screws, anodised aluminium fittings suitable Nylon gasket, nylon rollers, maruthi locks, handles, concealed star lock, aluminium F channel for fixing aluminium grill and all necessary fittings and fixtures etc all as specified etc complete of standard sections and fixing to cudappa stone/granite stone with necessary bolts/screws ,complete all as specified and directed by Engr-in-charge.
S&F Anodised aluminium door shutters ,powder coating of any colour (thickness of powder coating not less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. ,complete all as specified and directed by Engr-in-charge.
S&F aluminium anodized grill of 4.75 x 7.75 mm, size of opening 10cm, size of mesh RG 103 (as per royal grill) with aluminium channel `F' angle 20mmx15mm fixed to aluminium frame work ,complete all as specified and directed by Engr-in-charge.
S&F stainless steel wire mesh of 0.36mm dia of wire and average width of aperture 1.40mm & fixed with tinted tacks of galvanised over staples ,complete all as specified and directed by Engr-in-charge.
S&F sheet glass 4.00mm thick, ordinary quality and glazing n.exc 0.50Sqm in each pane , complete all as specified and directed by Engr-in-charge.
S&F Figured glass 4.00 mm thick, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane ,complete all as specified and directed by Engr-in-charge.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over 10mm thick in CM 1:3 as backing coat to receive cudappah stone slab ,complete all as specified and directed by Engr-in-charge.
S& F aluminium Mortice lock, type 2 Levers vertical type, size 100 mm ,complete all as specified and directed by Engr-in-charge.
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length of cover plate 150mm ,complete all as specified and directed by Engr-in-charge.
M&L Sheet glass 5.5mm thickness , ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed
S&F, in repair, Door closer aluminium ( extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg ,complete all as specified and directed by Engr-in-charge.
S & F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty ,complete all as specified and directed by Engr-in-charge.
S & F 12 mm thick Medium density fibre board, exterior grade, fixed to timber framework with screws ,complete all as specified and directed by Engr-in-charge.
M&L for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface ,complete all as specified and as directed Engineer-in-charge.
M & L for 80 mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2006 ,M-40 Grade ,complete all as specified and as directed Engineer-in-charge.
M & L for 75 mm thick PCC type C2,1:3:6( using 40 mm graded stone aggregate) ,complete all as specified and directed by Engr-in-charge.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard or dense soil ,complete all as specified and directed by Engr-in-charge.
Excavation in trenches, exc 1.5 mtr wide and n,exc 3.00 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and laying of Water Main /Pipe, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/loose Soil, for foundation of poles ,complete all as specified and directed by Engr-in-charge.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, in any type of soil ,complete all as specified and directed by Engr-in-charge.
Removing excavated materials, in soil ,not exc. 50 Metre and depositing where directed at a level not exc. 1.50 Metre above the starting point, ,complete all as specified and directed by Engr-in-charge.
M&L for fine sand cushioning in trenches 80 mm thick before laying the cable and 150 mm thick after laying the cable ,complete all as specified and directed by Engr-in-charge.
Supply and laying un reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches ,complete all as specified and directed by Engr-in-charge.
Supply & laying XLPE insulated , screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminum conductor, 1100 V grade, of sizes: 2 core x 10 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fix Pre stressed concrete pole of 11 meter long having 102 mm x 172 mm at top and 102 mm x 289 mm at bottom ,including foundation and coping class 10, complete all as specified and directed by Engr-in-Charge.
M&L for for applying two coat of Cement based paint on PCC poles of street lights 9m overall length including preparation of old painted surface of PCC Poles ,complete all as specified and directed by Engr-in-Charge.
Supply and fixing Reflector adhishive tape of red colour minimum 25 mm width with suitable for fixing on street light pole ,complete all as specified and directed by Engr-in-Charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete , type D-2 (1:4:8) using 40mm graded stone aggregate as in foundations, filling & mass concrete ,complete all as specified and directed by Engr-in-Charge.
M&L for PCC, type B-1,1:2:4 using 20mm graded stone aggregate, as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed by Engr-in-charge.
Supply, fixing and testing LED street light fitting of 150 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report,complete all as specified and directed by Engr-in-Charge.
Supply, fixing and testing LED Road/Flood light fitting of 200 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report , complete all as specified and directed by Engr-in-Charge. Make: Crompton, Havells, philips, C&S, Bajaj, helonix, Wipro, Shakti
Supply, fixing and testing ,in repair Bolard light of 8 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report. complete all as specified and directed by Engr-in-Charge. Make: Crompton, Havells, philips, C&S, Bajaj, helonix, Wipro, Shakti
Supply, fixing and testing , in repair,Garden light of 70 Watt Suitable for pole dia Ø 50 mm for 15 W, Suitable for pole dia Ø 76 mm for 70W LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report .Make: Crompton, Havells, philips, C&S, Bajaj, helonix, Wipro, Shakti
Supply & fixing LED aviation light 30 watt made in cast aluminium spigot housing with decorative opal acrylic diffuser with IP-65 protection complete all as specified and as directed by the Engr- in- Charge. Make: Crompton ,Havells,philips, C&S, Bajaj
Supply, fixing and testing LED bulb for security light fitting of 25/30 Watt including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report.
Taking down carefully high mast light fittings from 20 mtr height pole mechanically including re- fixing the same its in own position duely repaired, complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable and dislocated Copper/aluminium strip of any size from floor of any size hight complete all as specified and directed by Engr-in-Charge.
Supply and fix , in repair, copper strip of 20x3.00 mm as roof conductor and down conductor till test point complete all as specified and directed by Engr-in-Charge. Note-Copper strip to be jointed through brazing only
Supply and fix , in repair, Galvanised strip of 20x3.00 mm as roof conductor and down conductor till test point complete all as specified and directed by Engr-in-Charge. Note-Galvanised strip to be jointed through brazing only
Supply and fix , in repair, copper strip of 32x6.00 mm as roof conductor and down conductor till test point complete all as specified and directed by Engr-in-Charge. Note-Copper strip to be jointed through brazzing only all as directed
Refixing the old serviceable copper/aluminium strip any size on the existing location after necessary repair complete all as specified and directed by Engr-in-Charge. Note-copper strip to be jointed through brazzing only all as directed
Taking down unserviceable and dislocated air termination rod of any type from floor of any size, complete all as specified and directed by Engr-in-Charge.
Refixing the old serviceable copper air termination rod on the existing location after necessary repair ,complete all as specified and directed by Engr-in-Charge. Note- strip to be jointed on air termination rod through brazing only
Refixing the old serviceable Aluminium air termination rod on the existing location after necessary repair ,complete all as specified and directed by Engr-in-Charge.Note- strip to be jointed on air termination rod through brazing only
Supply and fix , in repair, single pointed soild copper rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/down conductor, complete all as specified and directed by Engr-in-Charge.
Supply and fix , in repair, of single pointed soild Aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor ,complete all as specified and directed by Engr-in-Charge.
S&F,in repair Porcealing insulators for fixing Copper strip on wall / Roof bldg with necessary screws washers and nut bolts etc all Specified . Note - Rates are inclusive of copper screws with washers for fixing copper strip on porciline insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement, complete all as specified and directed by Engr-in-Charge.
Supply and fix, in repair, Medium grade GI pipe of 20 mm dia for fixing air termination rod, the pipe shall be suitably tapered for fixing the saddle insulator at an interval not exceeding 0.5 meter, the pipe should be laid vertically and should be properly supported, length of each vertically pipe should not exceed 3 RM, the air termination rod, down conductors should be insulated from the pipe ,complete all as specified and directed by Engr-in-Charge.
S&F,in repair, The terminal block made with gun metal size 75x75x25mm drilled and screwed including 3 nos of 8mm dia & 25mm long hex head of gun metal screw, complete all as specified and directed by Engr-in-Charge.
S&F , in repair, PVC cable with copper condcutor 2x2.5 sqmm Single core including conduit ,complete all as specified and directed by Engr-in-Charge.
Supply and fix , in repair, street light timer anlog type with 24 Hours operation setting including ML-4 contractor 63 Amps Three phase 430 volt AC with Control wiring of 6 Sqmm copper wire with TPN MCB of 63 Amps , 10 KA and 20 Amps single phase backlite fuse including sheet metal enclouser of 2mm thick with powder coating with mounting arragenets, angle iron frame and PCC foundation etc, complete all as specified and directed by Engr-in-Charge.
M&L security light bracket made with GI pipe 40 mm dia medium grade minium length 2 mtr long with 105 degree angle including necessary MS clamp made with 25mm x 5 mm and suitable MS studs and bolts complete all as specified and as directed by the Engr- in- Charge. Note: Contractor quoted rate shall be deemed to be included with fixing clamp and anchor fasterner for GI Steel tubing , complete all as specified and directed by Engr-in-Charge.
Taking down Submain wiring/ point wiring of any size and making even and smooth surface of wall floor with existing surface etc , complete all as specified and directed by Engr-in-Charge.
M & L for submain wiring with two single core through PVC insulated unsheathed stranded copper conductor 2.5 sqmm (nominal area) drawing through PVC conduit concealed and 1.5 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly , complete all as specified and directed by Engr-in-Charge. (Note : Cutting chases for counduit and sinking"s for boxes and makeing good to walls, floors etc for sub main wiring will be measured & paid separately in respective items).
M & L for submain wiring with two single core through PVC insulated unsheathed stranded copper conductor 4.0 sqmm (nominal area) drawing through PVC conduit concealed and 4.0 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly(Note : Cutting chases for counduit and sinking"s for boxes and makeing good to walls, floors etc for sub main wiring will be measured & paid separately in respective items).
Taking down LED indoor industrial lightening/Tube lights from any height and keep in safe custody including refixing the same after necessary civil work, complete all as specified and directed by Engr-in-Charge.
Supply, fixing and testing LED down light fitting of 180 Watt including LED lamps complete with RADIOSO HIGHBAY Energy saving, environment friendly & robust highbay LED luminaire with high efficiancy suitable for ceiling(Surface/Suspended).body robust,corrosion resistant,superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD (I) less than 10%, cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report.
S&F Batten type LED light fitting 1x18/20watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumen, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. MAKE: HAVELLS/WIPRO/BAJAJ/C&S/PHILIPS/SHAKTI
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor FR PVC insulated and unsheathed cable 1100 V grade confirming to IS 694 drwan through PVC conduit of suitable size heavy grade ISI marked including necessary conduit accessories, sunken type pressed steel terminal boxes with plastic laminated sheet 3mm thick of approved shade including 1.5 mm PVC insulated flame retardant copper conductor as in continious earth wire for the following :-
One Light point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per Srl item No 113.00 above but with 2.5 Sqmm wire for 15 Amp socket outlet on independent board
Supply & Fix for switch piano flush button single pole one way 5 Amps, 250 V , complete all as specified and directed by Engr-in-Charge.
Supply and Fix switch socket combination 2 in 1, 5 pin, 5 Amps flush type 220 V ,complete all as specified and directed by Engr-in-Charge.
Supply and Fix switch socket combination 2 in 1, 6 pin, 5 and 15 Amps flush type 220 V complete all as specified and directed by Engr-in-Charge.
S&F,in repair, Ceiling rose, surface bakelite, 65mm x 50mm two to three terminals , complete all as specified and directed by Engr-in-Charge.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size , complete all as specified and directed by Engr-in-Charge.
M & L submain wiring with two single core through PVC insulated unsheathed stranded copper conductor 10 sqmm (nominal area) drawing through PVC coundit concealed and 6 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade for earth continuity conductor and connecting with main earth dolly ,complete all as specified and directed by Engr-in-Charge. Note : (i) Three lenght of wire along with conduit will be measured as one Length.
Taking down unserviceable DB/MCCB/MCB of any capacity and making good disturbed surface of wall/floor complete all as specified all as directed.
S & F Loadline Distribution board, TP&N vertical, with Bus bars, 200A, 415V Capacity,with Netural links, blanking plates, double door 8 way, provision for MCCB 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and directed by Engr-in-Charge.
S & F Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 8 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and directed by Engr-in-Charge.
Supply,fixing testing and commissioning of Miniature circuit breaker (MCB) of single poles 240V, 10 KA 'B' curve and current carrying capacity 5 to 32 AMP, in the MCB DB ,complete all as specified and directed by Engr-in-Charge.
Supply,fixing testing and commissioning of Miniature circuit breaker (MCB) of SPN with amp rating 240V, 10KA , 'C' curve of current carrying capacity 40 AMP in the MCB DB ,complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCCB TPN pole with thermal Release range 100 Amps, 18KA, 415V, 50 Hz including extension bar for connection cable, complete all as specified and directed by Engr-in-Charge.
S&F sheet metal enclosure plug and socket with 200 Amps rated bus bar 240 volts with one MCB SP 20 Amps ,complete all as specified and directed by Engr-in-Charge.
Supply & fix Type 1+2 surge protection device TP+N high discharge current Imax 50 Ka (L-N) 70ka (N-E) COMPACT SIZE INTEGRATED Type-1 & Type-2 protection in small module width. Ideal in all reduced size plants. Better voltage protection level 1.5kV complete all as specified. Make- havells,Legarnd,L&T
Earthing complete with copper earth plate electrode of size 60cmx60cmx3.15mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to & including copper earth strip of size 20X3 mm dia by means of GI bolts, nuts, washers, and connected to other end to main board duly protected by 15 mm bore GI light grade pipe from earth plate. Earth plate shall be surrounded by packed layer of coal dust 30 cm and common salt 15 cm thick all around bottom and top. Watering pipe 20 mm bore of GI medium grade pipe and including funnel, wire mesh, CI cover & frame, PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 5 of SSR Part – I. Rate are deemed to include 7.5 Mtr 20X3mm size copper strip Note : PCC/HDPE chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii). Earth resistance of earth pit should be less than 1 Ohms. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of Copper plate. (iv) Soil resistance test if required shall be the responsbility of contractor without any extra cost.
SAGAR ENTERPRISES
M/S VISHRANTA CONSTRUCTION
S K ENTERPRISES
R.C. Magla and Co.
Parmatma Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .