Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC 259 4TH CROSS HAL III STAGE BANGALORE 560075 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹33.1 L+₹3.0 L (9.82%)Rejected-AOC NO 45 5TH CROSS MALLAPPA LAYOUT BABUSAPALYA KALYAN NAGAR BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹36.5 L+₹6.4 L (21.2%)Rejected-AOC 6 A FIRST MAIN NEAR JAMIYA MASJID ISLAMPUR ANNASANDRAPALAYA HAL VIMANAPURA POST BANGALORE 560 017 | BANGALORE | BENGALURU URBAN | KARNATAKA | 560017 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.9 L+₹10.8 L (35.7%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.4 L+₹11.2 L (37.2%)Rejected-AOC NO 228 3RD CROSS HRBR 3RD BLOCK NEAR JALVAYU VIHAR WEST GATE BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L5 | Rejected-AOC Rejected |
| Sl No | Description | Qty | Unit | ABHISHEK CONSTRUCTIONS L1 | P Ramesh and Co L4 | M/S Suresh Raju L2 | OM ENTERPRISES L6 | S SELVALAKSHMI ENGINEER AND CONTRACTOR L5 | K. VENKATESH NAIDU L7 | MAA ENGINEERING SERVICERS L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old damaged existing water proofing membrane of any thickness from roof top of G+3 storeyed bldgs complete all as specified and directed.
Note: All waste materials shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. | 1,530 | Sqm | 15 ₹22,950 | 27 ₹41,310 | 5 ₹7,650 Lowest | 100 ₹1,53,000 | 60 ₹91,800 | 15 ₹22,950 | 19 ₹29,070 |
| 2.00 | M&L for water proofing treatment on horizontal and vertical surfaces with Providing and laying / fixing TPO (Thermoplastic Polyolefin) membrane incl cleaning the surface and laying of 200GSM Geo textile and cover up with TPO RF 1.2 mm thermoplastic membrane on roof of G+3 storeyed bldgs ; up to 300 mm height on parapets and crumple joint including junction of roof and parapet, welding the seam joints with hot air gun/machine and terminate the corners with extra protection to bear the high wind pressure. The TPO should be thoughroly tightened with the lower structure using mechanical fastening properly to avoid the corners and seam joint failure.
Make : Asian paints TPO or equivalent product of M/s Bauchemic /CIPY/SIKA/Pidilite/Dr fixit TPO membrane//M/s Berger | 1,530 | Sqm | 1,130 ₹17,28,900 | 1,611 ₹24,64,830 | 1,320 ₹20,19,600 | 1,300 ₹19,89,000 | 1,300 ₹19,89,000 | 2,009 ₹30,73,770 | 1,100 ₹16,83,000 Lowest |
| 3.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for in G+3 storeyed bldgs complete all as specified and as directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations for | 80.1 | Cum | 150 ₹12,015 Lowest | 360 ₹28,836 | 285 ₹22,828.5 | 650 ₹52,065 | 800 ₹64,080 | 249 ₹19,944.9 | 250 ₹20,025 |
| 4.00 | M&L Cutting out cracks to V-section in existing roofs or terracing of G+3 storeyed bldgs cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed. | 175 | RM | 100 ₹17,500 | 45 ₹7,875 Lowest | 121 ₹21,175 | 300 ₹52,500 | 120 ₹21,000 | 129 ₹22,575 | 100 ₹17,500 |
| 5.00 | M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope in G+3 storeyed bldgs complete all as specified and as directed. | 76.5 | Cum | 4,400 ₹3,36,600 | 4,500 ₹3,44,250 | 4,120 ₹3,15,180 Lowest | 8,500 ₹6,50,250 | 6,800 ₹5,20,200 | 6,999 ₹5,35,423.5 | 6,800 ₹5,20,200 |
| 6.00 | M&L for providing cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in G+3 storeyed bldgs complete all as specified. | 3.6 | Cum | 3,800 ₹13,680 Lowest | 6,300 ₹22,680 | 4,120 ₹14,832 | 6,500 ₹23,400 | 7,000 ₹25,200 | 10,500 ₹37,800 | 7,500 ₹27,000 |
| 7.00 | M&L Rendering 10 mm thick cement plaster 1:3 on roof padding of G+3 storeyed bldgs finished even and fair with approved water proofing compound @ 3% by weight of cement or as per manufacturer's instruction including taking down existing cement plaster/lime plaster complete all as specified and as directed.
(Note : WPC shall be measured and paid seperately as supply only under relevant item ) | 1,530 | Sqm | 120 ₹1,83,600 | 163 ₹2,49,390 | 150 ₹2,29,500 | 250 ₹3,82,500 | 300 ₹4,59,000 | 89 ₹1,36,170 Lowest | 110 ₹1,68,300 |
| 8.00 | Supply only liquid water proofing compound complete all as specified and as directed. | 51.47 | Ltr | 75 ₹3,860.25 | 90 ₹4,632.3 | 150 ₹7,720.5 | 250 ₹12,867.5 | 160 ₹8,235.2 | 45 ₹2,316.15 Lowest | 100 ₹5,147 |
| 9.00 | Demolition of brick work or stone masonry built in cement mortar including all quions, arches pillars etc, but excluding ashlar facing dressed stone works and pre-cast concrete articles in G+3 storeyed bldgs complete all as specified and as directed. | 13 | Cum | 100 ₹1,300 Lowest | 360 ₹4,680 | 285 ₹3,705 | 650 ₹8,450 | 600 ₹7,800 | 245 ₹3,185 | 250 ₹3,250 |
| 10.00 | M&L Precast cement concrete block in PCC 1:3:6 type C1 (20mm graded aggregate) masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6 in G+3 storeyed bldgs complete all as specified and as directed. | 13 | Cum | 4,800 ₹62,400 Lowest | 6,500 ₹84,500 | 5,120 ₹66,560 | 8,500 ₹1,10,500 | 7,600 ₹98,800 | 6,500 ₹84,500 | 6,500 ₹84,500 |
Tender Value
Refer Docs
EMD Value
₹96,122
Closing Date
5 Dec 2025, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE - 560006
SPECIAL REPAIR TO ROOF AT VARIOUS LOCATIONS AT MD ACCN (PH-II) AT CHAFB
2025_MES_739817_1
8420/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BANGALORE
AS PER NIT
5 documents required · 5 mandatory
₹500
GE (AF) BANGALORE
₹96,122
20 Dec 2025
14 Nov 2025
8 Dec 2025
14 Nov 2025
5 Dec 2025
28 Nov 2025
15 Nov 2025 - 22 Nov 2025
Amount
Taking down old damaged existing water proofing membrane of any thickness from roof top of G+3 storeyed bldgs complete all as specified and directed. Note: All waste materials shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for water proofing treatment on horizontal and vertical surfaces with Providing and laying / fixing TPO (Thermoplastic Polyolefin) membrane incl cleaning the surface and laying of 200GSM Geo textile and cover up with TPO RF 1.2 mm thermoplastic membrane on roof of G+3 storeyed bldgs ; up to 300 mm height on parapets and crumple joint including junction of roof and parapet, welding the seam joints with hot air gun/machine and terminate the corners with extra protection to bear the high wind pressure. The TPO should be thoughroly tightened with the lower structure using mechanical fastening properly to avoid the corners and seam joint failure. Make : Asian paints TPO or equivalent product of M/s Bauchemic /CIPY/SIKA/Pidilite/Dr fixit TPO membrane//M/s Berger
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for in G+3 storeyed bldgs complete all as specified and as directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations for
M&L Cutting out cracks to V-section in existing roofs or terracing of G+3 storeyed bldgs cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed.
M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope in G+3 storeyed bldgs complete all as specified and as directed.
M&L for providing cement concrete type B-1 (1:2:4) using 20mm graded aggregate as in roof kerbs or mud stops, rounded or chamfered on edges in G+3 storeyed bldgs complete all as specified.
M&L Rendering 10 mm thick cement plaster 1:3 on roof padding of G+3 storeyed bldgs finished even and fair with approved water proofing compound @ 3% by weight of cement or as per manufacturer's instruction including taking down existing cement plaster/lime plaster complete all as specified and as directed. (Note : WPC shall be measured and paid seperately as supply only under relevant item )
Supply only liquid water proofing compound complete all as specified and as directed.
Demolition of brick work or stone masonry built in cement mortar including all quions, arches pillars etc, but excluding ashlar facing dressed stone works and pre-cast concrete articles in G+3 storeyed bldgs complete all as specified and as directed.
M&L Precast cement concrete block in PCC 1:3:6 type C1 (20mm graded aggregate) masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6 in G+3 storeyed bldgs complete all as specified and as directed.
Demolition of cement concrete reinforced Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including RCC water tanks in G+3 storeyed bldgs complete all as specified and as directed.
Cutting holes in brickwalls built in cement mortar exc half brick but not exc one brick for inserting holdfasts ,clamp etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required in G+3 storeyed bldgs complete all as specified and as directed.
M&L Providing Reinforced cement concrete type B-1, 1:2:4 using 20 mm graded aggregate in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work in G+3 storeyed bldgs complete all as specified and as directed.
M&L Providing reinforced cement concrete type B-1, 1:2:4 (20 mm graded aggregate) chajjas including necessary form work in G+3 storeyed bldgs complete all as specified and as directed.
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls,/ceiling etc. including raking out joints, hacking for key, scrubbing down with water, etc. including necessary scaffolding in G+3 storeyed bldgs complete all as specified and as directed.
M&L Rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement motor 1:4 finished even and smooth without using extra cement including necessary scaffolding in G+3 storeyed bldgs complete all as specified and as directed.
M&L Rendering 10mm thick cement plaster on fair faces of concrete surfaces in ceiling/chajjas in cement mortar 1:4 finished even and smooth without using extra cement complete including necessary scaffolding in G+3 storeyed bldgs complete all as specified and as directed.
M&L Preparation of new plastered surfaces of wall and application of two coats of cement base paint through mechanical means over a coat of primer complete including necessary scaffolding in G+3 storeyed bldgs complete all as specified and as directed.
M&L Preparation of new plastered surfaces of wall and application of two coat of Weather proof exterior emulsion through mechanical means over a coat of primer in G+3 storeyed bldgs complete all as specified and as directed.
M&L Preparation of new plastered surfaces on ceiling and applying three coats of white wash complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 15mm bore complete all as specified and as directed. General Notes for Item No 22.00 to 33.00 :- Quoted rate shall deemed to include cost of scaffolding or ladders etc required for approaching for repair work (Ground floor to 3rd Floor).
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 20mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing or removal to store for 25mm bore complete all as specified and as directed.
S&F Steel tube15mm bore medium grade galvanized with all fittings and connections, complete all as specified and as directed.
S&F Steel tube 20mm bore medium grade galvanized with all fittings and connections, complete all as specified and as directed.
S&F Steel tube 25mm bore medium grade galvanized with all fittings and connections, complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing and Refixing old steel tubing and connections,fittings etc in new or old position (Walls, ceiling, floors, etc.) of 15 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections, fittings etc including cleaning for refixing and Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) of 20 mm bore complete all as specified and as directed.
Taking up or down steel tubing and connections, fittihgs etc including cleaning for refixing and Refixing old steel tubing and connections, fittings etc in new or old position (Walls, ceiling, floors, etc.) of 25 mm bore complete all as specified and as directed.
S&F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs 25mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
S&F in repairs Ball brass valves, 20mm dia bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F Triple layered Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted & fixed in position all as specified in SSR Part I , 500 Ltrs Capacity including dismantling existing 500 Ltr water tanks complete all as specified and as directed.
Disconnecting existing tanks, setting aside or lowering if required for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in old or new location position capacity exc 250&n exc 500 ltr complete all as specified and as directed.
S&F in repairs PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls in verticial surfaces of upto and incl 4 storied buildings, complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm dia complete all as specified and directed.
Removing building materials etc. (other than spoil payable under items-earthwork) to a distance of 30.00 Km or above, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M/S Suresh Raju (BID ID -3491608)
MAA ENGINEERING SERVICERS (BID ID -3485625)
P Ramesh and Co (BID ID -3490589)
S SELVALAKSHMI ENGINEER AND CONTRACTOR (BID ID -3495762)
OM ENTERPRISES (BID ID -3491938)
K. VENKATESH NAIDU (BID ID -3496261)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
SOC_8420.pdf
Additional Documents • 0.02 MB
Tender_8420.pdf
Tender Documents • 0.56 MB
BOQ_828395.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .