| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 CrAccepted-AOC 1095 ELDECO 2 UPHAAR SECTOR 3 RAIBAREILLY ROAD LUCKNOW UP PIN 226002 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226002 | ₹35.3 Cr | L1 | Accepted-AOC Being L-1 |
| 2 | L2₹36.7 CrRejected-Finance | ₹36.7 Cr | L2 | Rejected-Finance Being L2 |
| 3 | L3₹37.8 CrRejected-Finance | ₹37.8 Cr | L3 | Rejected-Finance Being L3 |
| 4 | L4₹40.7 CrRejected-Finance | ₹40.7 Cr | L4 | Rejected-Finance Being L4 |
| 5 | L5₹42.1 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹42.1 Cr | L5 | Rejected-Finance Being L5 |
Tender Value
₹31.2 Cr
EMD Value
₹15 L
Closing Date
30 Oct 2023, 6:00 pmClosed
Chief Engineer Lucknow Zone,
Headquarters Chief Engineers Lucknow Zone, Lucknow-226002
PROVISION OF CERTAIN DEFI MD ACCN FOR OFFRS, JCOS AND ORS AT KANPUR
2023_MES_577267_3
CELZ/KAN/T-13 OF 2022-23
Open Tender
Construction Works
810 days
Kanpur
As per NIT
7 documents required · 7 mandatory
₹3,000
GE(I) Kanpur
₹15 L
Yes
Lucknow
6 Nov 2023
9 Oct 2023
1 Nov 2023
9 Oct 2023
30 Oct 2023
23 Oct 2023
9 Oct 2023 - 14 Oct 2023
19 Oct 2023
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Road, Path & Hard standing )
Total amount of Sch 'A' Part VI (Area Drainage)
Total amount of Sch 'A' Part VII (Sewage Disposal)
Total amount of Sch 'A' Part VIII (Compound wall & Gate )
Total amount of Sch 'A' Part IX (External Water Supply )
Total amount of Sch 'A' Part X (External Electrification )
Total amount of Sch 'A' Part XI (Hot water supply)
Total amount of Sch 'A' Part XII (Rain Water Harvesting )
Total amount of Sch 'A' Part XIII (Garbege Bins )
Sch 'A' Part - XIV (Miscellaneous Items for B/R & E/M Works) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S& F Angle valve, cast copper alloy chromium plated ISI marked, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule of 15 mm bore & fixed, complete all as specified and directed. Make:- Jaquar SQT-526 NKN/Hindware F 260004/Parryware G4643 A1 or equivalent as approved by GE.
S& F Two way angle valve, cast copper alloy chromium plated ISI marked, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule of 15 mm bore & fixed, complete all as specified and directed.
S&F health faucent (1.5 m long tube) with hook (hand spray) with CP body of 15 mm bore & fixed, complete all as specified and directed. Make:- Jaquar ALE-BLC-593 /Hindware /Parryware T9962A1 or equivalent as ap-proved by GE.
S&F chromium plated wall mixer 3 in 1 complete all as specified and directed. Make:- Jaquar ORB 105281/Hindware /Parryware T 3917A1 or equivalent as approved by GE.
S&F chromium plated central hole basin mixer complete all as specified and directed. Make:- Jaquar MQT-516 AKN/Hindware F-460009/Parryware G 4715A1 or equivalent as approved by GE.
S&F chromium plated sink mixer , complete all as specified and directed. Make:- Jaquar ORB-105309/Hindware/Parryware or equivalent as approved by GE.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan/Bell point controlled by one switch with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLSH cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and heavy duty PVC conduit not less than 20 mm in roof / floor slab and ceiling and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall / roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost..
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLSH CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for point wiring complete with PVC insulated and unsheathed, FRLSH cable 2.5 sqmm (nominal area), ISI marked, stranded copper conductor single core including ISI marked 20mm dia medium grade PVC conduit concealed in wall and MS conduit in roof/floor slab, pressed GI concealed terminal boxes not less than 1.6mm thick of reqd size and with top cover 3mm thick of plastic laminated sheets of required colour complete, including 2.5 Sqmm, FRLS cable PVC insulated unsheathed multi stranded copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories and all as specified. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
Supply and fixing Switch flush type 5/6 Amps single pole two way complete all as specified and dierected.
Supply and fixing Telephone Scoket Modular with ISI marked complete all as specified and dierected.
Supply and fixing Telephone Scoket with ISI marked complete all as specified and dierected.
Supply and fixing TV Scoket with ISI marked complete all as specified and dierected.
Supply and fixing modular metal flush box for 8 Module complete all as specifed and directed.
S&F MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suit-able size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCCB and with en-closure blank plates for unused way suitable for 4 way complete all as specified and directed
S&F 415 Volt 10 KA 'B' curve MCB TPN 40 to 100 Amp and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN 40 Amps 'B’ series,10 KA 240 Volts, AC complete all as specified and directed.
S&F MCB single pole 6-32 Amp rating 'B' Series,10 KA 240 Volts, AC 50 Hz ,ISI marked complete all as specified and directed .
S&F MCCB 4 pole, 415 Volt, AC fixed type 125 amps with breaking capacity 10 KA complete all as specified and directed.
S&F MCCB 4 pole, 415 Volt, AC fixed type 63 amps with breaking capacity 10 KA complete all as specified and directed.
S&F LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 9 W) luminaire lumen >1000 lm, system efficiency of >120 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification.complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a luminous efficiency of 120 lum/watt(min) with PF not less than 0.9 with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F LED Building security light fitting 25 Watt with aluminum pressure die cast housing, high purity PC Fresnel diffuser with silicon gasket for IP-65 protection, power consumption <20 W (24W) & luminaire lumen >2500 lm and system efficiency > 120 lm/W, in built electronic driver prewired upto terminal block with driver efficiency >85% power factor >0.95 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and made out of GI tubing 35/40 mm dia /suitable dia light grade bend to shape security light fitting with necessary MS clamp 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminum paint including nuts, bolts and washers complete all as specified and directed.
S&F circular slim surface LED Decorative Wall mounting of 12 Watts with LED Bulb 12 watts complete Polycarbonate housing, globe type Glass protection with high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <12W, luminaire lumen>1000lm, driver and accessories to be prewired, CRI>70, LED efficiency > 120 lm/W photo biological safety report as per IEC624718 & electrical insulation class I, LED life with L70 criteries -37000 hrs colour temp >6000K, Ingress protection IP-20, ambient temperature 0 to 450C, driver efficiency >85%, THD<10% as per IEC 61000-3-2, power factor >0.95, surge protection 2.5 KV, two stages isolatated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification complete all as specified and directed.
S&F circular slim surface LED downlighter of 8 Watts with housing made up of die cast aluminum for better thermal management, high transmitivity non yellowing PMMA diffuser for better light output and uniform light distribution without glare, power consumption <10W, luminaire lumen>1000lm, driver and accessories to be prewired, CRI>70, LED efficiency > 120 lm/W photo biological safety report as per IEC624718 & electrical insulation class I, LED life with L70 criteries -37000 hrs colour temp >6000K, Ingress protection IP-20, ambient temperature 0 to 450C, driver efficiency >85%, THD<10% as per IEC 61000-3-2, power factor >0.95, surge protection 2.5 KV, two stages isolatated constant current operated driver with range 150-270V AC and safety extra low voltage safe level <60V DC as per IEC standard with LM79 & LM80 certification.complete all as specified and directed.
Supply, installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % with remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. Note:- (a) Additional down rod if required will be measured and paid separately under respective items. (b) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
Supply, installation, testing and commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC) motor, class insulation B, 3 Nos blades, 30/40 Cm long down rod, 2 no canopy, shackle kit, safety rope, copper winding, power factor not less than 0.90 services value (CMM/W) minimum 6.0 Air delivery min 210 CMM, 350 RPM (tolerance as per IS: 3742019) THD less than 10 % with remote and electronic regulator unit for speed control and all remaining accessories including safety pin, nuts, bolts, washers, suitable for 230 V, 50 Hz single phase AC supply earthing etc and connecting up the fan to ceiling rose including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to ceiling fan motor not less than 0.5 mtr long with PVC connector 2 way/3 way for connection and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed. Note:- (a) Additional down rod if required will be measured and paid separately under respective items. (b) T&P will be provided by the contractor for reaching any height of the building/warehouse/Hanger
Supply and fixing Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 250 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, grouting of nuts, bolts, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side (outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
Supply and fixing Exhaust Fan high quality mettalic body, resistant to colour change 300 mm sweep, 900 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit pipe from celling rose to exhaust fan motor and writing MES No. in black synthetic enamel paint/engraving tools etc complete all as specified and directed
Earthing complete with galvanised mild steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate using GI earth wire 4 mm dia as earth electrode connected to bolts, nuts, check nuts and washers of GI or steel etc at one end and connected to equipment at another end.GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipment 20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit cover slab of 50 mm thick precast RCC (1:1.5:3) type A-1 duly reinforced with MS TMT bars 8 mm dia @ 150 mm c/c both ways with 10 mm dia MS round bar as in lifting handles, excavation earth work including laying the GI pipe concealed in floor/wall all as described in electric plate no 3 of SSR part I complete all as specified and directed and testing on completion. Note:- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Earthing wire beyond 7.5m shall be measured and paid separately.
SEWAGE DISPOSAL M&L for RCC Septic tank for 200 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
M&L for RCC Septic tank for 100 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
M&L for RCC Septic tank for 50 user designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., complete with effective depth of 1.5 meter and overall depth of 3 meter complete all as speci-fied and shown on drawings No. TD-750 Sheet 1/2 & 2/2.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.60 M dia X 3.0 M effective depth complete all as speci-fied and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as speci-fied and shown on drawings No. TD-576 Sheet 1/2 & 2/2.
EXTERNAL WATER SUPPLY Supply, laying, testing and commissioning Ductile Iron pipe, 150 mm bore including Rubber gasket joints, Class K-9 in any length laid in trenches complete all as specified and directed.
Supply, laying, testing and commissioning Ductile Iron pipe, 100 mm bore including Rubber gasket joints, Class K-7 in any length laid in trenches complete all as specified and directed.
Taking down old serviceable CI/DI pipe line upto 200 mm bore from the trenches and relaying in different location after cleaning the pipe including new fittings such as required at site laid in trenches or on floors/Road/path etc and making good the disturbed surface to match with existing surface as (PCC work in 1:2:4 type B-1 using 20 mm graded crushed stone aggregate) complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 900 mm X 900 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Construction of fly ash brick masonry valve pit chamber of size 600 mm X 600 mm X 900 mm (internal dimensions) including necessary excavation & earth work, 100 mm thick PCC (1:4:8) type D-2 as in foundation, 230 mm thick fly ash brick work in cement mortar (1:4), 12 mm thick rendering in cement mortar (1:4) on internal surface of valve pit and mild steel sheet cover of 6 mm thick and angle iron of size (50 x 50 x 6) mm frame around of valve pit, sheet welded on all four corners, locking arrangement with pad lock of size 50 mm brass, 6 levers and in duplicate key (Make - Godrej or equivalent make as approved by GE complete) including two coat of approved synthetic enamel paint over one coat of red oxide primer on prepared steel surface complete all as specified and directed.
Deploying required plant and machinery for boring 250 mm dia size pilot bore through any kind of soil / strata including hard stone / boulder by direct rotary method up to and including 200 Mtrs depth below ground level complete all as specified and directed. Note: Location decided by as per CGWB report.
Ditto all as per srl no. 14.43 here-in-before but depth exceeding 200 Mtrs but not exceeding 400 Mtrs complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 675 mm, from 0 to 70 Mtr deep below ground level of reaming 675 mm size including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 525 mm dia exceeding 70 Mtr but not exceeding 145 Mtr deep below ground level including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 525 mm dia exceeding 145 Mtr but not exceeding 230 Mtr deep below ground level including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 525 mm dia exceeding 230 Mtr but not exceeding 315 Mtr deep below ground level including all works pertain to boring complete all as specified and directed.
Reaming (Expanding) vertical bore of pilot bore of 525 mm dia exceeding 315 Mtr but not exceeding 400 Mtr deep below ground level including all works pertain to boring complete all as specified and directed. Note for srl item No 14. 45 to 14.49 :- The drill Cutting should be carefully and sysmetically collected at regular interval of 3 M or whenever lithology changes and all informartion should be properly recorded.
M&L for Mild steel sheet casing plain ERW casing pipe 304 mm bore, 8 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. NOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side.
M&L for Mild steel sheet casing plain ERW casing pipe 200 mm bore, 5.40 mm thickness, conforming to IS: 4270 -2001, ISI marked, lowering and fixing in position upto required depth in all strata cut into different length including cutting, welding pipe jointed and welded coupler rings through out circumference of the pipe and coupler rings both side as in bore wells complete all as specified and directed. NOTE :- (i) Length of each pipe shall not be less than 2.4 metre except where pipe length required is less than 2.4 meters. (ii) Welding shall be done through out the circumference of the pipe and coupler rings both side.
Supply and fixing MS strainer slotted pipe 200 mm nominal bore 5.4 mm thick confirming to IS complete all as specified. Note :- (i) The size of slot shall be designed by the contractor based on aquifierers regularly arranged at the equal distance all around the slotted pipe so as to make the perforation area 15 to 20 % of slotted piped, jointed complete all as specified in purticular specifications and as directed by the Engineer- in Charge. (ii) Length of each pipe to be provided in casing shall not be less than 2.4 Mtrs except where pipe length required is less than 2.4 Mtrs.
M&L for Mild steel reducing socket of size 304 mm x 203 mm including welding MS strip of size 40 x 6 mm (02 Nos) on each joint extended 75 mm on each side complete all as specified and directed. Note:- The wall thickness of the Socket side shall not be less than 14.00 mm.
S& F wrought iron bail plug 200 bore 1.5 M long MS pipe welded with 15 mm thick MS plate including 10 mm thick "U" hook bar all as specified and directed.
Supply and laying pea gravel for packing of size 3 to 5 mm to be designed by the contractor of natural shape brought direct from river bed and packing around the casing pipe and slotted pipe complete all as specified and directed.
Developing the tube well with not less then 250PSI capacity air compressor as required until clear water is obtained including transportation, errection and dismantling of air compressor complete all as specified and directed.
Ditto all as per srl no. 14.56 here-in-before but by means of over pumping unit at the rate 25% above 32 LPS discharge ie; 40 LPS consisting of VT pump as required until sand free water is obtained complete all as specified and directed.
S&F steel wire rope 12 mm dia un galvanized stranded with ‘D’ clamps shackle type for holding the motor & pump with ‘U’ clamp complete all as specified and directed.
Supply of strata sample box with glass cover 3mm thick and having internal dimentions 900x400x150mm deep made of 25 mm thick teak wood plank having peagon hole and fully glazed on one side displaying strata sample as found while drilling tube well complete having letters painted, also including preparation of bore well chart on tracing cloth complete showing various strata complete all as specified and as directerd.
Collection of water sample, carrying to approved analytical chemical laboratory for bacterilogical, chemical, and sanitary tests after the development of well, all as desired by department to ensure the water fit for human consumption complete all as specified and directed.
S&F MS column pipes heavy duty screwed 150 mm nominal dia 3 Mtr long having wall thickness not less than 7.1 mm electric resistance welded with MS flange heavy duty on both side conforming to IS and with provision of 8 nos holes welded all around with pipe for rigidness and 4 Nos ribs 10 mm thick including 2 mm thick rubber sheet of suitable length and washer shall be conforming to IS. complete all as specified and directed.
Electric logging provision in pilot bore for precise delination of granular zones as also the quality of ground water including report interpretation complete all as specified and directed. Note : Electric logging shall be carried out by any approved Govt Agency.
S&F chain pully block capacity 5 ton without tripod, manual type with ceiling, nut, bolts, washers including suitable size of MS chain for lowering & lifting complete all as specified and directed.
S&F submersible cable 3 core 16 sq mm 1100 volts grade flat type with copper conductor PVC insulated and PVC sheathed over all suitable for water submersible motor and starter complete all as specified and directed.
S&F M seal joint suitable for submersible cable water proof and with brass ferrules etc; complete for 3 core 16 sqmm copper conductor cable 1100 volts grade complete all as specified and directed.
S&F connecting piece one end flanged and other end screwed duly welded 1.5 Mtr long MS column pipe 150 mm dia bore for connection to column pipe and NRV of submersible pump 125/150 mm dia complete all as specified and directed.
Supply, installation, commissioning and testing submersible pump set of discharge capacity 900 LPM at 90 Mtr head with suitable size of submersible motor inside the bore well comprising of bronze impellors in CI casing with stainless steel shaft, leaded bronze bearing / bushes stainless steel shaft, sleeve complete all as per IS 8034 of 1989 complete with submersible motor AC 3 phase, 50 Hz, 380 to 440 Volt complete all as specified and directed.
Supply, install connecting and commissioning Chlorine granular based Chlorine dosing pump,(1-100 PSI) high pressure, single head gear motored adjustable dosing pump with accessories such as lead tubing, connecting nuts, injection check valve, clay weight and ferrules including anchoring bolts with nuts and washers, piping work for inlet and outlet and cabling with control switch gear including 50-100 ltr PE/ FRP tank with PE/ FRP lid & level gauge along with agitator 960 rpm with shaft & blade complete all as specified and directed. The pump shall be suitable for 20000 to 25000 GPH discharge capacity, line pressure of 3kg/cm2 and chlorination requirement from 0.5PPM to 5PPM complete all as specified and directed.
Supply only Chlorine based high strength granular chemical for chlorination which free flowing granular material free of foreign matter, decomposing at 177 C, decomposes in water and alcohol, not hygroscopic, practically clear in water solution at saturation level. complete all as specified and directed.
M&L for fully automatic star delta starter suitable for 30 HP pump set. complete all as specified and directed.
S&F of wire less electronic water level indicator electrically operated showing indicator of O/H tank at pump houses building received from RCC O/H tank complete all as specified and directed. .
EXTERNAL ELECTRIFICATION M&L for drilling manually in soft/loose soil under road/hard standing/culvert/nala of suitable bore for protection GI pipe upto 80 mm bore complete all as specified and as directed . Note: Depth of bore shall not be more than 1 Mtr from original ground level.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32x6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B-1 using 20 mm graded stone aggregate, mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 40 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
S & F Energy saving and environmental friendly long life 30 W, LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with all fixing arangement, nuts, bolts and washers on existing bracket mounted on Swan neck poles and LT Poles etc making electrical connection and testing complete all as specified and directed.
Supply, fixing, testing and commissioning of automatic street light switch of capacity 8 KW in three phase using nature switch for automatic switching of street lights based on LUX level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals enclosed in pole / wall mounted enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box (Make: Sintex) conforming to IP54, including mounting arrangement with suitable size of FI clamps 02 Nos with complete accessories as under including taking down old street light switch complete all as specified and directed. (i) Contactor rating (AC3) single phase, 50-63 Amp] (ii) MCB 63Amps (SP),10 KA, 240 volts (iii) NATURE SWITCH-01
S & F in repair cable junction box 430mm x265mm x 170mm (double door hinged) in size made out of thermoplastic sheet having IP 65 protection for out door installation fixed with 4 way bakelite cable terminals with one MCB SP 6 Amps to be fixed inside the box including 03 Nos polynide gland with check nut (M-32 - 3 Nos) fixed on pole with flat iron clamps of size 25 x 3mm, nuts, bolts, washers etc., including two coats of synthetic enamel paint over a coat of redoxide zinc chrome primer complete all as specified and as directed.
Supply, erecting and installation of steel tubular, swaged pole 9 meters long complete with cast iron base plate, finial taper plug, bolts and nuts and screws as specified of type 410 SP-31 conforming to IS-2713-1980 duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be paid separately under respective items.
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, powder coated, IP54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :- BUSBAR :- 300 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with rotary handle - 01 No. (ii) Digital multifunctinal meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (i) MCCB 4 pole of capacity 63 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 03 Nos (ii) MCB 4 pole of capacity 63 Amp - 01 Nos
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, powder coated, IP54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :- BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with rotary handle - 01 No. (ii) Digital multifunctional meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (i) 4 pole MCCB of capacity 63 Amp, breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 04 Nos
Supply, installing, testing and commissioning outdoor type LT feeder piller box double door type (Safety Centre) of suitable size, padestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double, front side openable, powder coated, IP54 protection made of CRCA sheet 3.15 mm thick of outer panel and 2.00 mm thick inner compartment of panel size as per IS and having proper locking arrangement in front side door suitable for 440 volts, 50 Hz, 3 phase 4 wire system including cable glands of suitable size for incoming and outgoing cables and comprising with and including following accessories and mounted on PCC Plat form min 45 cm from ground level and PCC 1:3:6, 100 mm thick, 0.5 m all round the panel board complete with the following items housed in :- BUSBAR :- 400 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite / DMC insulator bus bar support (Square / round) insulators of suitable size and good insulation resistance (Busbar to MCCB shall be connected through suitable size of copper busbar). INCOMING:- (i) 4 pole MCCB of capacity 160 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 35/36 KA with thermal megnatic release type with rotary handle- 01 No. (ii) Digital multifunctional meter V, A, F, kW, KVA, kWh, kVAh, kVArh, THD, Neutral current, Max Demand (with RTC),- 01 No. (iii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (RED, ORANGE, BLUE) -01 set (iv) CT (200/5A) -03 Nos OUTGOING:- (I) MCCB 4 pole of capacity 100 Amp breaking capacity 25 KA with thermal magnetic release, adjustable type with rotary handle - 02 Nos (ii) MCB 4 pole of capacity 63 Amp - 01 Nos
Supplying, installation, testing & commissioning of outdoor 11 KV, extensible 630 Amps, 21kA IP54 Outdoor type SF6 gas insulated 630 Amp Copper busbar RMU comprising of manual 3 Load Break Switch . The LBS shall be enclosed in robotically welded minimum 2.5 mm thick non magnetic, non ferrite Stainless Steel tank filled with SF6 with IP class IP67 , leak rate less than 0.1% and HT tank tested for internal arc fault of 21kA upto 01-second as per latest IEC 62271-200. The unit shall have front/side/rear cable entry for ease of installation. Fault Passage Indicator in all LBS. The outer enclosure shall cover the full length of the switch gear, to ensure IP54 protection for full door covering of complete switchgear Cable bushings shall be site replaceable type for repair of RMU at site. (Inspection of RMU to be done at above manufacturer's factory) 1.Load break switch module - 3 Nos. 2-Manual operated 12 KV, 630A Load Break switch and Earthing Switch with making capacity. 3- “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. 4-Earth fault passage indicator in all LBS. 5-Mechanical ON/OFF/EARTH Indication. 6-Cable boxes suitable for 1x3Cx300 sq mm XLPE Cable with right angle Cable Termination Protectors, situated towards side of RMU. 7-Cable Door should be arc proof and interlocked with respective Earthing Switches. For safety of operator it should not be possible to open the cable Door unless the earth Switch is ON. 8- Cable box should be arc proof with bolted door and interlocked with respective earthing switches. (i) The contractor will produce drawing of load break switch (LBS) for according approval before the ordering of material.
M & L, Installation, commissioning and testing of new LT panel cubical type suitable for outdoor installation factory made CPRI approved of suitable size , dust & vermin proof fabricated out of 3.15 mm thick CRCA sheet duly powder coated with cable entry & exit with suitable size of glands, terminals & thimbles all as specified , duly mounted on angle iron frame fixed on RCC/PCC block fixed with grounded bolts & nuts and washers including suitable rating copper bus bar 250 Amps for 3 phase 4 wire mounted on epoxy based post insulators, LED indicator lamp set type RYB, MCB DP 32 Amp-05 and suitable for one incoming MCCB 160 Amps 4 pole 36 ka, one No 100 amps 4 pole 25 ka as outgoing, Digital ammeter, voltmeter, CTs of required size, thimble & cable gland for incoming and outgoing cables and wiring with suitable size of PVC copper cable/strip complete and making good all disturbed surfaces of floor/wall using RCC/PCC work as required at site complete all as specified and directed.
Supply, installing, testing and commissioning of out door type, floor mounted step down transformer, 11 KV/433 Volts (at no load) AC 3 phase 50 Hz, 315 KVA capacity, core type, double copper wound, oil immersed, naturally cooled, Oil Natural-Air Natural (ON AN), with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5% to -10%in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 40 degree celsius in oil and 45 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius. Perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS 1180 (Part-I) : 2014, Energy Efficient Level -II as per latest amendment IS-1180(Pt-I) and shall comprise of the following :-
One cable box on HT side (primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception 120 sqmm x 3 core, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete all as specified and directed.
One cable box on LT side (Secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable size/rating of cable complete.
Oil conservator with filter type drain valve and oil level guage
De-hydrating breather with first fill of dehydrating agent (silica gel).
Explosive vent, Thermometer pocket on tank cover, Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap / plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers
One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
Two earthing terminals on tank cover to facilitate fixing of earth strip for earthing of body
Rating plate and terminal marking plate.
Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral.
First fill of new and unused transformer oil, IS-335 marked, filtered and tested upto 50 KV die-lectric strength at 2.5 mm air gap between testing electrodes.
Provn the angle iron channel for floor mounted outdoor type transfomer as per site requirement.
Providing adequate size and nos of channels, embeded in platform floor, for movement of transformer.
Unidirectional roller wheel.
Other accessories as per manufacturer design.
Supply, installation, testing & commissioning HT 12 KV indoor type AIR insulated withdraw able vacuum circuit breaker (VCB) in powder coated steel enclosure Structure made by Aluzinc / Sendzimir GI. Full encapsulation of VCB poles with no partial encapsulation will be accepted., horizontal isolation, horizontal drawout type with following specifications IAC 26.3kA/1sec AFLR, PM LSC-2B, with factory fitted exhaust duct. Aluminium Bus bar. Self supported Insulated Busbar with full voltage rated sleeve should be used. VI mechanical operations 30000. VCB tested for Humidity test as per IEC 62271-100. Floor rolling design for ease of maintainence. Make of VCB Vacuum Interrupter and Panel should be same. :- (i) Incoming Cum Outgoing Air insulated VCB having rupturing capacity 250 MVA. Note:- Incoming/outgoing Air insulated VCB should have following specification:- Moving portion:-
(a) 12 KV, 630 A 26.3 KA, Air insulated VCB panel with suitable vaccum interruptor complete with suitable motorized & manually operated spring charged system - 01 No
(b) CT AND PT DETAILs (i) Single phase, 2 core CT with 100-50/5+5 -03 Nos. Core I : Class-1, 5 VA Core II : Class 5P10, 7.5 VA (ii) 3 phase 11 KV/110 volts class-1.0 potential transformer with 100 VA burden.
(c) Breaker panel indication lamps shall be provided for following functions:- (i) Breaker ON- 01 No (ii) Breaker OFF- 01 No (iii) Auto Trip Indication- 01 No (iv) Three phase indication- 03 Nos
(d) SWITCHES AND OTHER ACCESSORIES (i) Circuit breaker control switch- 01 No. (ii) Hooter- 01 No (iii) Heater with heater switch & thermostat- 01 No (iv) Cubical illumination lamp- 01 No. (v) 15A, 230V, 3 pin plug, plug & socket- 01 No (vi) Power pack- 01 No
(e) METERs (i) Digital intelligent panel meter indicating line current, line voltage, power factor,KVAR, KVA, frequency, voltage and current harmonics etc with acuracy 1.0 for active energy.
(f) RELAYS Numerical relay non programmable for over current and earth fault protection,inbuilt software, SCADA compatible for remote communications with provision of recording of last 5 faults complete all as directed.
Supply, installing, commissioning and testing complete of manufacturer of OEM (Original Equipment Manufacture) manufactured and tested static outdoor Silent Diesel Engine driven generating set capable of delivering 62.50 KVA, 415 volts (AC 3 Phase, 4 wire system of supply) 50 Hz at minimum power factor 0.8 . The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on Dunlop metallastik foundation pads on a common base frame and threafter intalled in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms and as specified) all as specified complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete and shall comprise of the following :-
Diesel Driven Engine (Prime mover) :- Diesel engine 4 stroke water cooled, electric start of suitable for 62.50 KVA alternator under NTP condition, water cooled conforming to BS 5514, BS9 649,IS 10000 capable of taking 10% overloading for one hour after 12 hours of continuous operation, the engine will be fitted complete with all the required accessories. (i) Fuel filter. (ii) Governor (Electronic). (iii) Lubricant oil cooler. (iv) Lubricant oil pump. (v) Lubricant oil filter. (vi) Digital Oil pressure gauge (vii) Any other parts as prescribed by manufacturer for making it functional (viii) Heavy fly wheel housing complete with fly wheel, starting gear ring and to suit flexible coupling duly covered with mud guard. (ix) Dry type air filter. (x) Radiator with cooling fan and guard. (xi) Water temperature gauge. (xii) Air cleaner (xiii) Coupling guard. (xiv) . emergency stop button. (xv) Self starter of suitable size. (xvi) illumination inside canopy/enclosure with LED light. (xvii) Fuel injector pump (xviii) Electric starting with battery charging alternator including one numbers of high capacity maintenance free lead acid battery 180 AH, 12 volt including inter connection cable with lead, lugs and in between with and terminal complete. (xix) Self starter with auto electric start accessories (xx) Engine safety low lubricant oil pressure and high coolant temperature.
Engine mounted instrument Panel :-fitted with having digital display for following:(i) Start-Stop switch with key. (ii) Water temprature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temprature indication (v) Battery charging indication(vi)RPM Indication (vii) Over speed indication (viii) Low lub Oil trip Indication (ix) Engine Hours Indication.
Alternator:- Synchronous alternator rated at 62.5 KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with minimum 0.8 power factor. The alternator shall be having SPDP( screen protected dust proof) enclosure, brushless, continuous duty, self excited, self regulated, through AVR (with + 1% voltage regulation directly coupled to and match the above engine and capable for over load of 10% for one hr in 12 hr operation ) conforming to IS:4722/BS 2613 suitable for tropical condition and with class `H' insulation.
Accoustic enclosure:- Accoustic and wether proof enclosure as per CPCB norms with arrangement for fresh air intake for cooling of the engine & alternator ,extraction, dicharging hot air in to the atmosphere as per specifications :-(i) Fabricated out of CRCA sheet of suitable thickness as per manufacture design. Polyster based powder coated internally and externally with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The doors are gasketed with EPDM gaskets. (iii) the acoustic lining should be made up of high quality insulation material i.e. rock wool/mineral wool/glass/PU foam of appropriate thickness & density for sound absorption as per standard design of manufacture's to reduce the sound level as per CPCB norms. the insulation material shall be covered with fine glass fiber cloth and would be supported by perforated M/S sheet duly power coated/GI sheet/aluminium sheet (iv) Emergency stop push button out side the container. (v) Provn of light inside the canopy providing of LED fitting 1x20 watt with wiring and control switch
Base Frame & Foundation:- Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and anti vibration pads or vibration isolation arrangement as per recommendation of manufacture.
Fuel Tank:- Daily Service fuel tank capacity of as per manufacturer's design but not less then 12 hours running on full load capacity fabricated out of 3 mm thick or specified by OEM M.S. Sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C' pipes of suitable dia. complete with valves, level indication, floor mounted with suitable angle iron for supports & accessories as required as per specifications.
Exhaust System:- Silence absorption type, non-resistance, residential and exhaust pipe covered with asbestos rope lagging extending to about 2 mtrs outside the acoustic enclosures and all as per manufacturer recommendations
AMF PANEL:-S&F testing & commissioning of automatic mains failure control including auto by-pass panel suitable for 62.50 KVA silent type DG set complete with relays, timers, Set of three CTs for metering& protection and energy analyser to indicate currents, phase and line voltaes, frequency, power factor ,KWH,KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if re-quired, all complete and interlocking including the following: (i)Contactor 100 Amps, Ac 415 Volts,50 Hz-02 NOs and MCCB 4 pole 415 Volts 50 Hz 100 Amps 36 Ka AC supply having microprocessor based release for short circuit over current and earth fault protection IS-13947 marked complete with racking interlock and push button - 02 Nos AMF logic Battery charger Aluminium bus bar of suitable capacity complete.(ii) Key switch/Auto start generator set controller AMF logic unit. (iii) Indicating lamps for load on mains and load on set.(iv) Fuse for instruments.
The firm shall be provided the following :- (a) Manufacturers maint & operation manual & spare parts catalogue of DG set - 01 Sets. (b) Manufacturers test certificate.
RAIN WATRER HARVESTING: M&L for Trial bore of 200 mm dia upto 200 m depth below GL in any kind of Soil strata including hard stone/boulder including electric logging MS Cap., MS flat iron clamps, reducing socket etc complete all as specified and directed.
M&L for development of trial bore from 200mm to 350mm reaming up to 525 mm for 60mtr from Ground level including slotted pipe of 200mm dia and thickness 8mm and pea gravel complete all as specified and directed.
Supply and laying pipe UPVC class 'B' complete including special, OD 160 mm dia complete all as specified and directed..
GANGA INFRABUILD PVT LTD
BD AGARWAL BUILDTECH INDIA PRIVATE LIMITED
LUMOS INFRA PVT LTD
RAGHUSONS INFRA ENGINEERING PVT. LTD
Varindera Constructions Limited
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid