Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹18.2 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹18.9 L+₹74,244 (4.09%)Rejected-Finance | L-2 | Rejected-Finance High Rates | |
| 3 | L-3₹19.5 L+₹1.3 L (7.19%)Rejected-Finance | L-3 | Rejected-Finance High Rates | |
| 4 | L-4₹19.6 L+₹1.4 L (7.87%)Rejected-Finance D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L-4 | Rejected-Finance High Rates | |
| 5 | L-5₹20.4 L+₹2.2 L (12.3%)Rejected-Finance | L-5 | Rejected-Finance High Rates |
| Sl No | Description | Qty | Unit | Auto Traders L2 | Ms Kailash Chandra Babulal L5 | M/s Navansh Engineers & Consultants L4 | Vending Services And Solutions L1 | SAHYOG ELECTRIC L3 | M/s Pratik Enterprise L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Day to day comprehensive maintenance of anytype of street lights, flood lights, for any type 0f pole, RCC, tubular, swan neck inclunding taking down old unsvsteel tubular, replacement of submain wiring of fitting,one electrician and one helper to be present daily in complaint cell at 9.30 am with necessary T&P as per site requirement for attending complaints related to the street lights under AOR of GE (MCTE) failing to which a penalty of@ RS 500 per complaints is deducted from contract if not rectified within 24 Hs in same day, material for each complaints is to be measured under relavent items all as specified and directed by engineer in charge. | 120 | Each Job | 1,349 ₹1,61,880 | 1,300 ₹1,56,000 | 150 ₹18,000 | 55 ₹6,600 | 50 ₹6,000 Lowest | 100 ₹12,000 |
| 2.00 | S&F in repair led street light 90 Watt with Epoxy Polyster powder coated pressure die-cast aluminium housing, LEDs are provided with non-yellowing decorative IP lens optic,Silicon gaskets provided for LEDs and control gear compartments, The driver used is specially designed to have built-in surge voltage, open/ short circuit protections, External surge protection provided for additional safety, Side entry mounting for 55 to 65mm OD pipe bracket. ressure die-cast aluminium housing for aiming adjustment of 90 watt led street light with high power led lumnious efficacy 130 lm/watt,correlated color temperature 5665K±355K, luminous flux 11700 lm, CRI >70, Die cast aluminum body with pennut lens, Impact resistence 08, Ingress protection 66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minimum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips or authorisedonly, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 3 years and same should be produced to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed. | 110 | Each | 3,576 ₹3,93,360 | 3,800 ₹4,18,000 | 4,080 ₹4,48,800 | 3,010 ₹3,31,100 Lowest | 3,400 ₹3,74,000 | 6,000 ₹6,60,000 |
| 3.00 | All as per Srl item No. 2 above but capacity 60 Watts complete all as specified and directed. | 12 | Each | 2,533 ₹30,396 | 3,000 ₹36,000 | 3,250 ₹39,000 | 2,110 ₹25,320 Lowest | 3,000 ₹36,000 | 4,500 ₹54,000 |
| 4.00 | S&F in repair of 200 watt led flood light Graphite grey powder coated; matt finished pressure die?cast aluminium housing designed to act as heat sink for
efficient dissipation of heat, Heat resistant toughened glass provided with silicon gasket for efficient Ingress protection, LEDs are provided with secondary polycarbonate lens optics to get optimum optical performance,Constant current LED driver used is specially designed to have built-in surge voltage, open/ short circuit protections. Luminaire is provided with a MS mounting bracket fixed on
pressure die-cast aluminium housing for aiming adjustment of 200 watt led flood light with high power led lumnious efficacy 120 lm/watt,correlated color temperature 5665K±355K, luminous flux 24000 lm, CRI >70, Die cast aluminum body with toughned glass along with pennut lens, Impact resistence 08, Ingress protection >66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips only, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 5 years and same should be prodused to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed. | 14 | Each | 8,049 ₹1,12,686 | 8,400 ₹1,17,600 | 8,150 ₹1,14,100 | 5,280 ₹73,920 Lowest | 8,200 ₹1,14,800 | 7,000 ₹98,000 |
| 5.00 | All as per Srl item No. 4 above but 120 Watt complete all as specified and directed. | 10 | Each | 4,990 ₹49,900 | 5,300 ₹53,000 | 4,900 ₹49,000 | 4,150 ₹41,500 | 5,140 ₹51,400 | 4,000 ₹40,000 Lowest |
| 6.00 | All as per item No. 4 above but 150 Watt complete all as specified and directed. | 8 | Each | 6,249 ₹49,992 | 6,700 ₹53,600 | 5,600 ₹44,800 | 4,845 ₹38,760 Lowest | 6,520 ₹52,160 | 5,000 ₹40,000 |
| 7.00 | Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed. | 238.5 | Cum | 100 ₹23,850 | 85 ₹20,272.5 | 130 ₹31,005 | 135 ₹32,197.5 | 90 ₹21,465 | 60 ₹14,310 Lowest |
| 8.00 | Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed. | 143.5 | Cum | 38 ₹5,453 | 30 ₹4,305 | 30 ₹4,305 | 55 ₹7,892.5 | 20 ₹2,870 Lowest | 99 ₹14,206.5 |
| 9.00 | Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed. | 139 | Cum | 38 ₹5,282 | 30 ₹4,170 | 20 ₹2,780 Lowest | 95 ₹13,205 | 20 ₹2,780 Lowest | 79 ₹10,981 |
| 10.00 | M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and directed.
(Note : Punned thickness of sand shall be measured) | 113.5 | Cum | 650 ₹73,775 | 550 ₹62,425 | 550 ₹62,425 | 890 ₹1,01,015 | 600 ₹68,100 | 450 ₹51,075 Lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
2 Aug 2025, 6:00 pmClosed
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
REPAIR AND MAINT OF STREET LIGHT FITTINGS, POLE PAINTING, JUNCTION BOX AND ALLIED WORK ITEM UNDER GE (MCTE) MHOW
2025_MES_718561_1
GE(MCTE)/MHOW/18(T) OF 2025-26
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
Yes
GE (MCTE) Mhow
₹60,000
Yes
18 Sept 2025
5 Jul 2025
4 Aug 2025
5 Jul 2025
2 Aug 2025
19 Jul 2025
Amount
Day to day comprehensive maintenance of anytype of street lights, flood lights, for any type 0f pole, RCC, tubular, swan neck inclunding taking down old unsvsteel tubular, replacement of submain wiring of fitting,one electrician and one helper to be present daily in complaint cell at 9.30 am with necessary T&P as per site requirement for attending complaints related to the street lights under AOR of GE (MCTE) failing to which a penalty of@ RS 500 per complaints is deducted from contract if not rectified within 24 Hs in same day, material for each complaints is to be measured under relavent items all as specified and directed by engineer in charge.
S&F in repair led street light 90 Watt with Epoxy Polyster powder coated pressure die-cast aluminium housing, LEDs are provided with non-yellowing decorative IP lens optic,Silicon gaskets provided for LEDs and control gear compartments, The driver used is specially designed to have built-in surge voltage, open/ short circuit protections, External surge protection provided for additional safety, Side entry mounting for 55 to 65mm OD pipe bracket. ressure die-cast aluminium housing for aiming adjustment of 90 watt led street light with high power led lumnious efficacy 130 lm/watt,correlated color temperature 5665K±355K, luminous flux 11700 lm, CRI >70, Die cast aluminum body with pennut lens, Impact resistence 08, Ingress protection 66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minimum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips or authorisedonly, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 3 years and same should be produced to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed.
All as per Srl item No. 2 above but capacity 60 Watts complete all as specified and directed.
S&F in repair of 200 watt led flood light Graphite grey powder coated; matt finished pressure die?cast aluminium housing designed to act as heat sink for efficient dissipation of heat, Heat resistant toughened glass provided with silicon gasket for efficient Ingress protection, LEDs are provided with secondary polycarbonate lens optics to get optimum optical performance,Constant current LED driver used is specially designed to have built-in surge voltage, open/ short circuit protections. Luminaire is provided with a MS mounting bracket fixed on pressure die-cast aluminium housing for aiming adjustment of 200 watt led flood light with high power led lumnious efficacy 120 lm/watt,correlated color temperature 5665K±355K, luminous flux 24000 lm, CRI >70, Die cast aluminum body with toughned glass along with pennut lens, Impact resistence 08, Ingress protection >66, Built surge protection 4kv and 10kv both will be inbulid in fixture only, Maintenance of lumen output will be minum 50,000 hours as per L70B50 clause, Led Chip will be reputed brand only Osram, Cree, Nichee, Birgdelux, philips only, Power factor will be >0.95 not less than .95. Warranty certificate of LED fitting should be atleast 5 years and same should be prodused to department through OEM directly. Any defects within warranty period will be rectified by contractor and earth connection of each light fitting should be connected to the system earth point either with 3 core cable or though seprate earth cable complete all as specified and directed.
All as per Srl item No. 4 above but 120 Watt complete all as specified and directed.
All as per item No. 4 above but 150 Watt complete all as specified and directed.
Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for filling approved fine river sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and directed. (Note : Punned thickness of sand shall be measured)
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed.
S&F of brackets for street light fitting fabricated out of 40mm bore GI tube, light grade, 1500mm long, made to shape and drilled holes etc, fixed to poles with suitable MS clamps fabricated from 40mm x 5mm MS flat duly painted in two coats of anti corrossive aluminium paint over a coat of red oxide zinc chrome primer and fixed with suitable sizes of bolts, nuts and washers and taking out old bracket of any length and shape complete all as specified and directed.
S&F GI tubing, light grade, 50mm bore pipe laid in trenches/ duct or in road crossing or fixed to wall/ poles for protection of cable complete including taking down old unsv GI tubing complete all as specified and directed.
All as per Srl item No.13 above but 40 mm bore pipe complete all as specified and directed.
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles/ walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete all as specified and directed, for the following :-
(a) 10 Sqmm 2 core complete all as specified and directed.
(b) 10 Sqmm 4 core complete all as specified and directed.
(c) 16 sqmm 4 core complete all as specified and directed.
S&F in replacement sheet moulding compound (SMC) junction box, suitable for terminating 2 Nos 4 x 10/16 Sqmm UG cable, including of one in Nos MCB SP 10A, 240 volts, AC, 50 Hz, including cable glandes-2 Nos, 4 Nos of AL bus bar with 3 Nos hols for cable connection, two way connector 1 No. complete all as specified and directed.
Cutting the existing bituminuos road for passing of UG Cable in road crossing and making good the disturbed surface of road to its original specification complete all as specified and directed.
S&F in replacement of Automatic Street Light control switch for three phase load of 5 KW, using Infrared Sensor based NATURE SWITCH for automatic switching of street light. Nature Switch operation should be based on Natural Light Lux level. Required illuminance level for switching ON is ≤ 30 Lux and for switching OFF ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max. 12 hrs. The Sensor along with 03 Nos contactors each of 20 to 25 Amps capacity, Incoming MCBs and Outgoing MCBs of 20-25 Amps (03 Nos) and auto/ manual operation (Senser by Pass), size of circuit wiring should be multistranded FRLSH min size of 10 Sqmm should be enclosed in a pole/ wall mounted enclosure made of rust proof, Electric shock Proof, Termite proof and FRLSH grade SMC Junction box conforming to IP54 complete all as specified and directed.
All as per Srl item No.21 above but for single phase model Navdeep-66-3kw 1p including Sensor along with 01 Nos contactors 25 to 40 Amps capacity, Incoming MCBs and Outgoing MCBs of 25 to 40 Amps (01 Nos).
M&L for wiring with 1.5 sqmm 2 runs of single core multistrand PVC insulated, unsheathed cable with 1x1.5 sqmm earth wire conforming to IS - 694, 1100 volts with copper conductor drawn in and including 20mm dia or higher, non metalic PVC grey conduit with all accessories such as Tees, Elbows, Junction box, Reducers etc as required and connecting to existing main switch board/ distribution board to fittings and testing on completion incl taking down old wiring complete all as specified and directed. Note:- 2 runs of 1.5 Sqmm with 1x1.5 Sqmm earth wire cable and conduit will be measured as one unit i,e. 1 RM.
M&L for steel tubular swaged poles complete with MS base plate, finial taper plug, bolts, nuts & screws type 410, SP-31 (9 mtrs long), erected to truely vertical position, painting externaly embedded portion in PCC with black bitumenous paint and externally exposed to view portion with aluminium paint in two coats, making five alternate strips 30cm wide with black and yellow paint in two coats, marking MES number with black paint complete including taking down old unsv pole any type complete all as specified and directed. (Note : Excavation and PCC will be measured and paid separately under respective items).
M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) as in base foundation of the pole, complete all as specified and directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregate) as in foundation and mass filling for poles, stays etc complete all as specified and directed.
M&L for PCC 1:2:4 type B1 using (20mm graded crushed stone aggregate) as in coping of poles including necessary form work and finishing exposed surfaces complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, fixed type, 415 Volts 63 Amps capacity, 16 KA rating rupturing capacity complete all as specified and directed.
S&F in replacement of MCCB, 4 pole, fixed type, 415 Volts 100 Amps capacity, 16 KA rating rupturing capacity complete all as specified and directed.
S & F in repairs MCB SPN 6 to 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F in repairs MCB SP 240 volts 6 to 32 Amps, 10 KA breaking capacity, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
Repairs of existing unsv street/ security light fittings, any type and wattage, including all necessary parts which is required for fully functional againtaking down and refixing on LT pole after re freshing of connection & testing complete all as specified and directed.
Repairs of existing high mast light fittings, any type and wattage, taking down and refixing on pole after refreshing of connection & testing complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace charge controller suitable for above capacity of solar light and re fixing as own position complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace battery suitable for above capacity of solar light and re fixing as own position complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace connector suitable for above capacity solar light and re fixing as own position complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace sensor suitable for above capacity solar light and re fixing as own position complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace LED module suitable for above capacity solar light and re fixing as own position complete all as specified and directed.
Taking down old existing LED solar light fittings of capacity 24/ 25 watts from street light pole and replace ON/OFF switch suitable for above capacity solar light and re fixing as own position complete all as specified and directed.
M&L for painting to steel tubular swaged pole of 9 Mtr long complete with and including comprising the following works:- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of post office red colour synthetic enameled paint on upper portion and two coats of aluminium paint in lower portion as directed by Engg.-in-charge. (c) Forming coloured bands with white and red post office colour synthetic enameled paint at bottom and letter writing or numbering complete all as specified.
M&L for Cement based painting to RCC pole of 9 Mtr long complete with and including comprising the following works:- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of cement based paint on upper portion as directed by Engg.-in-charge. (c) Forming coloured bands with white and red post office colour cement based paint at bottom and letter writing or numbering complete all as specified.
Cutting, trimming and prunning of trees/ tree branches of any girth upto 2.5 m all around existing LT over head lines/ sourrounding street light and flood fitting including cleaning the area beneath the LT overhead lines/ Street lights poles and removing the debris from the site and depositing where directed.
Auto Traders (BID ID -3371853)
SAHYOG ELECTRIC (BID ID -3369319)
M/s Navansh Engineers & Consultants (BID ID -3372536)
Ms Kailash Chandra Babulal (BID ID -3372364)
M/s Pratik Enterprise (BID ID -3369290)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .