Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹13.4 L
EMD Value
₹13,360
Closing Date
27 Oct 2026, 2:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Superintending Engineer
Superintending Engineer, E.U.D.C.-1, 57, George Town, Prayagraj
Refer to Tender Description
2026_PVVNV_1194501_1
69/SE/EUDC-I-PRA/2026-27
Open Tender
Electrical Works
Lump-sum
180 days
Prayagraj
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
Account Number-0012002100504911
₹13,360
8 Oct 2026
8 Oct 2026
27 Oct 2026
8 Oct 2026
27 Oct 2026
8 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Shifting of 33 Kv Line Near Baghada over bridge Sabji Mandi in Deposit Scheme Under, E.U.D.D. Rambagh, Prayagraj | - | - | - | - |
| 1 | Erection and vertical installation of double pole structure using 9 Mtr. Long STP /PCC Pole. Work includes excavation of pits, grouting with cement concrete mix (1:4:8), and firm erection of poles in line with UPPCL standard construction drawings. The scope further includes supply & installation of all requisite components such as MS top channel (125x65x2240 mm), MS Channel T-off (125x65x1300mm), MS Channel Dropper (100x50x2028 mm), MS Channel Bracing (65x65x6 mm), pin insulators with GI pins, Disc Insulator as per requirements, MS bracing angles, GI clamps, base clamps, stone pad, Danger board with clamps nut and bolts, Barbed wire at each Pole. All associated hardware like GI nuts & bolts and washers where necessary will be arranged and installed by the contractor only 9 Mtr. Long STP /PCC Pole. will be provided by department. The work shall comply with REC construction practices, UPPCL technical standards, and all site-specific requirements ensuring complete structural and electrical safety. | 4 | No. | - | - |
| 2 | Erection of Single 9 Mtr. Long STP /PCC Pole complete with its all accessories at the requirement of site condition (stay clamp with nut bolt will be provided by the contractor) | 1 | No. | - | - |
| 3 | Grouting & plinthing of 9 Mtr. Long STP /PCC Pole, with proper plinthing & tapering Grouting in ratio 1:4:8, Cement, Stone Grit & Coarse Sand (all grouting material provided by the contractor) | 1 | No. | - | - |
| 4 | Earthing of 9 Mtr. Long STP /PCC Pole by MS Earthing rod 20x 2500 mm. (all material provided by the contractor) | 9 | No. | - | - |
| 5 | Laying of 33 kV 3x300 sq. mm XLPE cable by HDD Machine Drill / manually method with HDPE Pipe. The cable shall be laid below not less than the depth of 1050 mm from the surface of road/Digging of trench 1050 mm deep, 750 mm wide including supply of required material or 1st class bricks, stone pad. The cable shall be laid between two continuous rows of bricks River sand packing on all side of cables shall be done. The stone slab shall be laid on top of rows of the bricks parallel to the ground in such manner so that channels are formed covered in either direction. (HDPE pipe of PN6 PE80, Dia 160mm with clamp provided by the contractor) | 420 | Mtr. | - | - |
| 6 | Hanging of 33 KV XLPE cable of size 3x300 sq.mm (as per site condition) on existing or newly constructed 9 Meter long PCC/STP pole. The cable shall be fixed using stay wire and MS stay clamps suitable for the respective pole type, ensuring secure anchoring and maintaining standard clearance. Stay clamps with GI bolts, nuts, and washers shall be arranged and installed by the contractor. 33 KV XLPE cable of size 3x300 sq.mm and stay wire will be provided by department. Cable alignment shall be straight and sag-free, and all bends shall follow minimum bending radius norms as per IS:1255. The contractor shall ensure mechanical protection, tagging, and safety precautions throughout the execution. Work shall be carried out in accordance with UPPCL specifications and REC construction guidelines. | 120 | Mtr. | - | - |
| 7 | Fixing of 33 kV heat shrinkable type cable termination kits for XLPE insulated 3-core 3x300 sq.mm aluminum conductor cable. Kits shall conform to VDE-0278 / IEEE-48-1975 / IS:13573-1992 / ESI STD 09-13 and other relevant international standards. The scope includes preparation of cable ends, crimping of lugs, and application of stress control tubing, insulation sleeves, earthing arrangement, anti-tracking components, and final sealing. End Termination kits of Raychem/3M shall be installed complete with all necessary accessories and testing in accordance with UPPCL norms. The contractor shall supply the jointing kits with a minimum guarantee period of 2 years from the date of ERP measurement. All materials including lugs, sealing components, jointing kits, and tools shall be arranged by the contractor. | 10 | No. | - | - |
| 8 | Erection & grouting of stay Rod with Cement, Sand and Bricks ballast in ratio 1:4:8 and fastening the stay wire with pole and stay rod nuzzling. only stay set to be provided by Department | 8 | No. | - | - |
| 9 | Dismantling of existing Pole & ACSR Dog Conductor with all accessories installed at site. | 1 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.97 MB
T-No-69 Baghada 33 KV Line.docx
Tender Documents • 0.13 MB
BOQ_2255072.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .