Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,410Accepted-AOC A 111 JHILMIL COLONY EAST DELHI 110095 | SHAHDARA | DELHI | 110095 | L1 | Accepted-AOC work order has been awarded | |
| 2 | L2₹84,850+₹440 (0.52%)Rejected-Finance 256 MUNDHELA KHURD NEW DELHI 73 | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹88,145+₹3,735 (4.42%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L4₹95,065+₹10,655 (12.6%)Rejected-Finance N A | L4 | Rejected-Finance Not L1 |
Tender Value
₹99,044
EMD Value
₹1,981
Closing Date
5 Jul 2023, 1:00 pmClosed
EEE-I/SSZ
Room No.5 First Floor Vishwakarma Nagar Near Hanuman MandirJhilmil Colony Delhi-110095
Renovation/Rewiring along with installation of 1 Nos. A.C. at 29 block trilokpuri dispensary in ward no. 192 under SSZ.
2023_MCD_158855_1
EEE-I/SSZ/2023-24/7.1
Open Tender
Electrical Works
Item Rate
45 days
work
Please refer to tender documents
4 documents required · 4 mandatory
₹590
₹1,981
9 Oct 2024
26 Jun 2023
6 Jul 2023
26 Jun 2023
5 Jul 2023
26 Jun 2023
Amount
OD3597/2023-2024:Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
OD3598/2023-2024:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole).
OD3599/2023-2024:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
OD3600/2023-2024:SITC of 1200 mm sweep BEE 5 star rated AC ceilling with brussless direct current motor, class of insulation:B, 3 nos. blade,30cm down road 2 nos. canopies shackle kit safety ropr,copper winding, power factor not less than .9,service value minimum 6.85,air delivery minimum 215 cmm,350 rpm,THD less than 10%,remote or electrnoic regulator unit for speed control and all remaining accessories including safety pin nuts,bolts,washertemperature rise=75 degree,insulation resistance more than 2 megha ohm,suitable for 230 v,50 hz,single phase ac supply, earthing etc complete as required fan for suitable for 230 V, 50 Hz AC supply.
122.1.47:Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.1.44:Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >=0.95
122.2.28:SITC of 60W LED Flood Light luminiare fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.113:S/I/T/C of 2 TR, 2 star/3 star, window air conditioner having copper condenser coil, rotary compressor and R32/better refrigerant.
122.2.115:S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
OD3601/2023-2024:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
OD3602/2023-2024:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD3603/2023-2024:Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
OD3604/2023-2024:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. A). 3x4 sq mm
M/s. Krishna Electric. Co.
M/s Priyanshi Electricals
CANTILEVER ENGINEERS
Bidder Name
M/S. A.K. Electricals
CANTILEVER ENGINEERS
M/s. Krishna Electric. Co.
M/s Priyanshi Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .