| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.5 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹44.6 L+₹1.9 L (4.42%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹48.0 L+₹5.3 L (12.4%)Rejected-Finance PLOT NO RZ B 1 59 KH NO 534 535 BLOCK B 1 NEW ROHANPURA PP NO 1416 NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹49.3 L
EMD Value
₹98,500
Closing Date
3 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Central) Delhi Cantt
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
2022_MES_500344_1
GE/C-54/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (Central) Delhi Cantt
PROVN OF CERTAIN SANCTION WORKS IN THE AREA OF AGE B/R-II AND AGE E/M UNDER GE (CENTRAL) DELHI CANTT-10
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt
₹98,500
Yes
22 Feb 2022
8 Jan 2022
5 Feb 2022
8 Jan 2022
3 Feb 2022
22 Jan 2022
8 Jan 2022 - 22 Jan 2022
60 days
Amount
Demolition of Brickwork or stone/ boulder masonry but built in cement mortar in any description and position complete all as specified and directed.
Demolition concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below and above ground level) complete all as specified and directed.
Demolition of cement concrete(Reinforced) of any positipon in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of debries and rubbisdh out side of Mod land complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and taking out of trenches, if required complete all as specified and directed.
Taking up or down 15 mm dia GI tubing and connections complete all as specified and directed.
Taking up or down 20 mm dia GI tubing and connections complete all as specified and directed
Taking down Chowkats or frames exceeding 1.5 Sqm but not exceeding 4 Sqm each(without taking off shutters from the frames) all as specified and directed.
Taking down cement plaster on brick walls including racking out joints, hacking for key, scrubbing down with water etc.
Taking down aluminium door/ window frame including shutter of any description not exc 1.50 Sqm each complete all as specified and directed.
Taking down Chowkats or frames not exceeding 1.5 Sqm each(without taking off shutters from the frames) all as specified and directed.
Taking down aluminium door/ window frame including shutter of any descriptiont area exc 1.50 Sqm and n.exc 4.00 Sqm each complete all as specified and directed.
Taking down aluminium/wooden door/ window shutter of any descriptiont area exc 1.00 Sqm and n.exc 2.00 Sqm each complete all as specified and directed.
S & F for pressed steel frame door size 105 X 60mm with one or more revits including nessesary fixing lugs, hinges, lock strike plate etc complete all as specified and directed by Engr-in-Charge.
Removing of existing water proofing treatment of APP and removing of debries outside complete all as specified and directed by Engineer-in-Charge
M &L for Brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed .
M&L for rendering 10mm thick on top of roof concrete in cement mortar 1:4 with water proofing compound at the rate of 3% by weight of cement to have a smooth surface for laying of water proofing membrane. Note: Water proofing compound will be measured and paid seprately.
Supply only integral water proofing compound
Dismantling of 75 mm dia cast iron pipe (soil/waste/vent) with fittings etc fixed to walls,ceiling, on floors & from trenches if required including taking out any type of joints complete all as specified.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets
M&L for applying bituminous primer @0.3ltr/Sqm (Confirming to IS-3384) Including preparation of plastered roof surfaces. Complete all as specified and directed by Engineer-in-Charge.
M&L for applying a coat of hot blown grade bitumen 85/25 grade bitumen confirming to IS-702@ 1.20 Kg/Sqm on primed surface Complete all as specified and directed by Engr-in-Charge.
M&L for screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying tiles all as specified and directed.
M&L for 10mm thick screed plaster on fair faces of brick work/concrete in CM 1:3 to receive tiles as in dado complete all as specified and directed.
S&F for digital glossy finish vitrified tiles 9 to 10 mm thick of Dark shade (Square/rectangular) polished area of each tile not exceeding 0. 36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match.
All as per item No 24 hereinbefore but in vertical surfaces such as skirtings, dados and risers to steps etc
S&F for Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed.
S & F for 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as spd and directed by Engr-in-Charge.
M & L for 0.9mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instruction
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F for Drappery curtain rods decorative type stainless steel 25mm nominal dia of approved quality (Make-VISTA) (3mm wall thickness) including fixing of two number decorative brackets fixed in brick/concrete wall, two number of latto on both end s of curtain rods, complete all as specified and directed by Engr-in-Charge.
S & F 75 mm dia (bore of pipe) cast iron (sand cast) soil, waste, vent pipe in any length with or without ears with cement joint fixed to walls, complete all as specified.
S&F in repair 75mm dia (bore of pipe) cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with cement joints, complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), laid bedded and pointed in any mortar and removal and removing old tiles from premises complete all as specified and directed.
S&F for 125mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F for 100mm size butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S&F 150 mm long Extruded Aluminium handles, fabricated type, anodised complete all as specified and directed.
S & F for Aluminium (die cast) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repair complete all as spd.
S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165
Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as spd.
Excavation in trenches (soft/loose soil) n exc. 1.5m wide and n exc 1.5 m in depth for foundation etc. and getting out complete all as specified and directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,complete all as specified and directed
S&F 4mm thick plain sheet glass with wooden beads, PVC beads, aluminium beads, in square n. exc 0.5 Sqm in each pane, complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm of soil complete all as specified and directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point
M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where directed complete all as specified and directed.
M&L 100mm thick Cement Contrete D-2, 1:4:8 (40MM graded aggregate) complete all as specified and directed.
M & L Cement concrete type D-2, 1:4:8 (40 mm graded stone aggregate) in foundations, filling, mass concrete and Sub-Base complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D2 for concrete bed to drain pipes (150mm bore) including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
M & L 20 mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in CM 1:2 all as per specified and directed.
M & L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M & L for brickwork with old size subclass ‘B’ bricks, straight or curved on plan in half brick built in CM 1:4 complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (20mm graded aggregate) providing precast cement concrete in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar article with plain faces complete all as specified and directed.
M&L for Reinforced concrete pipes 150mm bore, class NP2, laid and jointed complete with collars laid in trenches or in floors complete all as specified and directed.
M&L for 15 mm thick in CM 1:4 on new/old surfaces of concrete or brick surfaces of walls or chajjas or pillars finished even and smooth without using extra cement including scaffolding and necessary formwork if required complete all as specified and directed.
M&L for rendering 15 mm in cement mortar 1:6 thick on fair faces of brick work or concrete surfaces complete all as specified and directed
Rendering 15mm thick in cement mortar 1:4, on fair faces of brick work or concrete surfaces, surface finished even and smooth without using extra cement
M&L for Complete removal of existing treatment on walls and smoothen the surfaces with a coat of 2mm thick wall care putty and applying two coats distemper oil emulsion over a coat of alkaliresistant priming all as specified and directed.
M&L for preparing New plastered surfaces and apply a coat of 2mm thick wall care putty for making smooth surface and applying two coats of distemper oil emulsion over coat of primer on surfaces of walls.
M&L for Newly plastered or unplastered wall surface and apply 2mm thick wall care putty for smooth surface and applying two coat of cement based paint over a coat of primer complete all as specified.
M&L for Complete removal of existing treatment and apply 2mm wall care putty for smooth surface of wall and applaiying two coat of cement based paint over a coat of primer complete all as specified and directed .
M&L for Complete removal of existing treatment of plastered or unplastered ceiling surface and applying two coats of distemper oil emulsion complete all as specified and directed.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per specification and directed by Engineer-in-Charge.
M&L for Prelaminated particleboard, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
M&L for 8.5mm thick prelam PVC coloured profile panelling with all thickness of 1.25mm each pannel 250mm wide with interlocking joints, coloured, shade, pattern/ designs approved fixed to walls or ceiling with solvent /screw including similar pattern moulding at all around of openings, junctions complete all as per manufacturer instruction and all as per specified and directed.
S&F for Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Seat and cover for pedestal pan complete all as specidfied and directed.
Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and directed.
M&L for RCC 1:2:4 type B1 (20mm graded stone aggregate) for Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F false ceiling using plain galvanised steel ceiling system consisting of 600X600 mm lay in tiles of pre coated galvanised steel sheet 0.5mm thick in white or coloured to be laid on grid system with 15mm wide T section of size 600 X 45 X 15 mm flanges having rotary stiching on the main runner. The main runner spaced 600 mm centre to centre flush fitting 600 mm long cross tees to be interlocked between runner at 600 mm centre to from 600X600 mm module perimeter trim to be wall angle of size 3000 X 45 X 15 mm secured to wall and including suspension system as per manufacturer instruction aomplete all as specified and directed. Make- Armstrong or equivalent.
M & L for preparation of new/old or untreated plastered surface of wall and applying two coat of cement based paint over one coat of primer from the same manufacturer including scaffolding if required complete all as specified and directed.
M&L Reinforced cement concrete M 25 ( Design Mix) using 20mm graded aggregate as in Foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge
M&L for coloured glazed ceramic tiles 300x600 x 7 to 8mm thick as in vertical surfaces of wall as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 Complete all as specified and directed.
M& L for non skid coloured rectified ceramic tiles 300x300x7 to 8mm thick in floors, etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed for laying floor in CM 1:6 complete all as specified and directed by Engineer in Charge, approved by GE.
M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floors with no pigment complete all as specified and directed
M & L for 18-20 mm thick Black Granite stone work (table rubbed and polished) fixed with neat cement paste as fixing material as in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite,front and side of slab moulded and polished complete all as specified and as directed by the Engineer-in-Charge. Note- The cost of making hole for Gas pipe in cooking plateform is included in unit cost of item and nothing extra shall be paid on this account.
Supply and fix TMT bars,6mm to 8mm, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified.
Supply and fix TMT bars, 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) but not less than 0.9 mm dia conforming to Fe-410 - 0, complete all as specified and all as directed.
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to battercomplete all as specified.
S & F rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
S & F for Aluminium alloy, anodised, sliding door bolt 300mm longwith hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as spd.
S & F for 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as spd.
S & F for 150mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as spd.
S & F for 140mm long floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring with rubber bush complete all as spd.
S&F in MS Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 comple all as specified and directed.
M & L for painting new or previously untreated steel and iron surfaces of any description, over 10cm in width or girth,not otherwise described with two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
S & F pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for APP based polymeric membrane mineral slate finish weighting not less than 3 kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method from authorised applicator and again apply two coats of 85/25 bitumen @ 1.2 kg/sqm only at at overlapping joints and upto 300 cm near parapet wall or raised portion complete all as specified and directed.
M&L for laying APP (Atatic Plypropylene ) modified five layered membrane minimum 3mm thick and weighing not less than 3.50 kg/sqm with centre core 160 GSM/Sqm: core reinforced ans laid with 75mm side overlap and 150mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as the manufacturer specification complete all as and directed by Engineer-in-Charge.
M&L for applying two coat of silver Shield BITUMINIOUS paint on app membrane complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 (using 20mm aggregate) type B-1 as in levelling course using WPC finished even and smooth without using extra cement (WPC shall be measured and paid seperately)
M&L 25mm thick PCC 1:2:4 type B1 (using 20mm graded stone agg) as in floor/ padding, for receving APP membrane complete all as specified and directed .
M & L Cement concrete 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops etc including weathering slightly rounded or chamfered edges and lintels , finished even and smooth without using extra cement including form work , complete all as specified and directed
S&F 15mm dia GI tubing medium grade ISI marked with all fittings and fixed to wall and ceiling or laid in floors, complete all as specified and directed
S&F 20mm dia GI tubing medium grade ISI marked with all fittings and fixed to wall and ceiling or laid in floors etc complete, all as specified.
S&Fin repair fancy type stainless steel towel rack 600mm long with lower hangers all as specified and directed.
S&F in repair aluminium hat pegs solid body 125mm to 175mm long.
S&F in repair aluminium anodised tubular rail 20mm dia D type 60cm long between flanges including per pair brackets for each towel rail.
S&F Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of cap 15mm dia complete all as directed
S&F in repair pillar tap 15mm dia, cast copper alloy with capstan heads, chromium plated screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shank and fly nut screwed for iron pipe & fixed.
S&F in repair 15mm bore CP Angle/stop valves fancy type, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repair 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S&F stop valves 15 mm bore CP With crutch or butterfly handle, screwed both ends for iron pipe or unions, complete all as directed.
S&F Powder Coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including aluminium alloy Powder coated standard 10mm section window grill as per approved sample and as per IS specifications joining cleat for fixing etc. complete all as specified
S&F Powder Coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.),hinges type B-21 100mm long (2no.) suitable handle ,(01 no.) complete all as specified. Note: The window shutters shall be double leaf and double shutter/double shutter and single leaf. The rates qouted by contractor deemed to be inclusive of entire completion of work like glass panes 4.00 mm thick and stainless steel wire coth 0.36mm nominal dia of wire average width of aperture 1.40mm complete. Net area to be measured for payment purpose.
S&F Fibre glass reinforced plastic (FRP) door frames of approved make with cross section 90mm x 45mm having single rebate of 32mm x 15mm to receive shutter of 30mm thickness. The laminate door frame mouloded with fire retardant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in al the three lags. The frame shall be covered with fible glass from all sides. MS stay shall be provided at the bottom to steady the frame complete all as specified and directed.
S&F FRP Door shutter shall be 30mm thick glass Fibre Reinforced Plastic (FRP) Pannelled door shutter of required colour and approved brand and manufacturer. Made with fire retardant grade unsaturated polyster resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned woode inside at required places for fixing of fittins, cast monolithically with 5mm thick FRP panels and incl hinges, trowel bolt, handle etc confirming to IS 14856-2000 including fixing to frame complete all as specified and directed.
Supply and fix PVC connection pipe of 15mm size with PTMT check nuts with washers of length 600mm, complete all as specified and directed.
S&F 1000 ltr capacity ISI marked rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 20mm graded stone aggregate) for Plinth protection laid to a slope of 1 in 24 in alternate basis system. Each bay shall not exceed 3m in length, 12mm wide & 75mm deep joint shall be formed between the bays which shall be filled with Mastic filling to full depth comprising a mixture of 1 part of heator hot blow bitumen 85/25 portion and two parts of heated badrapur sand (by volume) complete all as specified and directed.
S&F for 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F for 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F for 110mm bore PVC (SWR) bends any radius complete all as specified and directed.
M&L for PVC (SWR) floor /Nahani trap plain with including 63mm dia grating including jointing with solvent cement in repair complete all as specified and directed.
M&L for Cutting chases on brick or concrete surface and making good, cutting not exc 10 cm girt for concealed water tubing and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc.,
S&F 0.56mm thick plain aluminium sheeting alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the piece can be cut)
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specifed and directed. (Make: Jaquar or Equivalent)
Supply only sheet glass ordinary quality 5.5mm thick, in squares exc. 0.5 sqm each pane complete all as specified.
Supply & fix in repair PVC connection pipe of 15mm x 600mm long with 2 Nos brass check nuts with washers, complete all as specifed and directed
S&F stainless steel toilet paper holder with Flap recessed type complete all as specified and as directed. Make : Jaquar Cat No.: AHS -1553 or equivalent model of GROHE/ KEROVIT (Kajaria).
S&F in repair cast iron floor trap square type with Cockroch Proofing CP grating with or without hole including provision of jointing to waste pipes in run lead joint dia of outlet 75 mm, complete all as specified.
S&F wall hung WC of size 405 x 360 x 540 mm with soft close seat cover complete all as specified and as directed. (Make :Jaquar Cat No FNS-WHT-40951 or equivalent Model of GROHE/KEROVIT (Kajaria).
S&F Counter top wash hand basin of size 595 x 440 x 185 mm complete all as specified and as directed. Make : Jaquar Cat No.KUSWHAT-35901 or equivlaent Model of GROHE/KEROVIT (Karjaria).
S&F in repair vitreous china, wash hand basin white flat back size 550 x 400mm white complete waste, chain and pug and precelain stopper including bracket.
S&F CP brass 32 mm dia waste coupling of 130mm height for WHB complete all as specified and as directed. Make : Jaquar Cat ALD-709L130 or equivlaent Model of GROHE/KEROVIT (Karjaria).
S&F CP brass 32mm bore bottle trap (with internal partition) with 300mm & 190mm long wall connection pipes & Wall flanges complete all as specified and as directed. Make : Jaquar Cat ALD-769L 300x190 or equivlaent Model of GROHE/KEROVIT (Karjaria).
S&F slim concealed cistern with floor mounting frame, installation kit and 'S' type drain pipe connection set for wall hung WC (without flushing plate) complete all as specified & directed. Make : Jaquar Cat JCS-SHT-2400FS or equivlaent Model of GROHE/KEROVIT (Karjaria).
S&F PVC valveless, syphonic action type, flushing cistern, (10ltrs capacity) low level, white, with inlet, ball valve, float and handle including brackets
S&F control plate segment chrome plated flushing plate for concealed flushing cistern complete all as specified & directed. Make : Jaquar Cat JCP-CHR-392415-35901 or equivlaent Model of GROHE/KEROVIT (Karjaria).
S&F 15mm bore CP brass Bib Cock auto closing system with built in control cock with wall flange complete all as specified and as directed.
S&F 15mm bore CP brass Angular stop cock with wall flange complete all as specified & directed. Make : Jaquar Cat ALI-85053 or equivlaent Model of GROHE/KEROVIT (Karjaria).
S & F Brass CP health faucet hand shower type with 8mm dia 1.2 Meter long Flexible Tube and Wall Hook screwed for iron pipe fancy type long body all as specified and directed. (Make: Jaquar No ALD 573)
S & F in repair fancy type 250mm size square brass CP shower rose all as specified.
S&F in repair fancy type brass chromium plated soap dish holder complete all as specified. (Make : Jaquar No AKP 357331P)
S&F in repair fancy type 15mm dia brass chromium single lever sink mixer with 450 mm long braided hoses for mixing hot and cold water screwed down for iron pipe and fixed to kitchen sink complete all as specified. Make Jaquar Opal Prime series No OPP-15011BPM
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160m
S&F 6mm thick, copper back finish, looking mirror of required size, made of float sheet glass of best quality & approved make, over 12 mm thick marine board fixed to rawl plug with round head screws and washers including teak wood beading with melamine polish all around, complete in all respects inclusive of cost of all materials, labour, tools, tackles etc complete all as specified and as directed.
S&F in repair fancy type glass corner 300mm radius of 10mm thick toughned glass with CP railing fixed with screws fancy type complete all as specified . (Make: Jaquar or Equivalent)
S&F 15mm bore sensotronic sensor faucet for Wash basin with 175mm extension body complete all as specified & directed. (Make : Jaquar Cat No SN-CHR-51021A or equivalent Model of GROHE/KEROVIT (Kajaria).
M&L for in repair 32mm waste fittings brass of chromium plated for wash basin etc, with long screwed shanks and fly nut, flange end bedded in red lead cement and others and fixed.
S&F in repair 40mm waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed
S&F for PVC waste pipe complete all as specified and directed.
M&L switch Modular type 6 Amps 230V AC complete all as specified and directed by Engineer in charge.
M&L Modular socket outlet 5 pin 6 Amp socket 2 module complete all as specified.
M&L socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engr in charge.
M&L switch Modular type 16 Amps one way 230V AC complete all as specified.
Supply & Fix Modular five stepped type electronic fan regulator 2 module 230V AC complete all as specified.
M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
Taking down carefully copper/aluminium point wiring from wooden battan or conduits (light, fan, socket or power) complete including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size and make from the site and making good surface complete all as specified.
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid new PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches , socket out let and fan regulators etc, complete all as specified.
(a) One light /Ceiling fan/exhaust fan point controlled by one switch.
(b) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board.
All as per item No 55 above but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M&L point wiring with PVC unsheathed multi stranded copper conductor cable 2.5 sqmm FRLS 1100 Volts in New PVC concealed conduit in new M S steel terminal boxes modular including one run of using 1.5 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity, including fixing completly in wall with sutable sand and cement, complete all as specified and directed.
S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element 1.5 KW and not less than 5 star rating.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete.
Supply and fix MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
M&L MCB SPN 40 Amp "C " curve
Supply and fix MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
M&L for Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories concealed in walls all as specified and as directed.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including new PVC conduit medium grade not less than 20 mm dia, for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4 Sqmm size stranded conductor as earthwire.
M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including PVC conduit for submain wiring and connection complete including rigid PVC conduit FRLS grade,unsheathed copper conuctor cable of 6 Sqmm size stranded conductor as earthwire.
M&L for cutting steel tubing to required length for insertion of new Tee Branches, reducer in any position of 15mm dia pipe line complete all as specified and directed.
S&F of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of cap 15mm dia complete all as directed
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete.
Supply and fix LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 900 lm system lumen output with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete.
S&F in replacement of LED 9 to 10 watts bulkhead fitting with poly carbonate aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 100 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<20%, CRI>80, Color Temperature-6500K, Surge protection of 4 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed complete all as specified and directed by Engr-in-charge.
Supply and fix LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours , Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed by engr-in-charge.
Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm complete all as specified.
supply and fix recessed mounting LED FLAT panel 2"x2" made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20 Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete.
Supply & fix in repair factory made epoxy powder coated Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
M&L in replacement MCCB 125 Amps, 16 KA , 4P, 415 Volts, 50Hz , with thermal magnetic setting.
Supply and fix 45 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie is 100lm/W with a life class of 50,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete
S&f fresh air fan PVC body AC single phase 230/240 V of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete.
Supply and fixing ceiling fans three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery >220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including making connection with three core flexible, copper cable pvc insulated of suitable length, complete all as directed. Note BLDC Fan should work on existing electronic fan regulator.
S&f Wall mounted fans AC single phase 230/240 V, of size 400 mm sweep, speed RPM 1400,Sturdy and shock proof body for fixing of wall fan complete.
S&F PVC connection 15 mm size for cold water with PTMT nuts of length 450 mm complete all as specified and directed.
S&F CP connection 15 mm size with for hot water with PTMT nuts of length 450 mm.complete all as specified and directed.
Supply,laying in repairs of PVC under ground XLPE insulated heavy duty electric cables armoured with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laying in trenches, fixed along wall, through GI pipe under floor complete all as specified and directed by EIC.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position with 20mm Ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule Minimum wt 20mm-210grm and s&f in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed.
Schedule of Credit
imran construction company
M/S CHANDER MUNI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .