Tender Value
Refer Docs
EMD Value
₹96,200
Closing Date
16 Oct 2021, 6:00 pmClosed
CWE (SUBS) MUMBAI
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIRS FOR REPLACEMENT OF OLD UNSERVICEABLE HT 11KV OCBs WITH VCBs AGAINST BER UNDER GE NW BHANDUP
2021_MES_456963_1
8403/E8
Open Tender
Civil Works
Item Rate
180 days
HAMLA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (NW) BHANDUP
₹96,200
Yes
28 Oct 2021
18 Sept 2021
19 Oct 2021
18 Sept 2021
16 Oct 2021
6 Oct 2021
Amount
Supply, laying in trenches or fixed to wall/pole or passing through pipe or road crossing, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with aluminium conductor, 11KV grade, suitable for earthed system, with aluminium conductor of size 120 Sqmm 3 Core including taking down unserviceable HT cable of any type/size/description, etc complete all specified and directed.The HT cable shall confirm to code IS -7098(Part-2) /1985 specifications. (Note : Excavation & Earth work shall be measured and paid seprately).
Supply, laying in trenches or fixed to wall/pole or passing through pipe or road crossing, testing and commissioning of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty ) with aluminium conductor, 11KV grade, suitable for earthed system, with aluminium conductor of size 150 Sqmm 3 Core including taking down unserviceable HT cable of any type/size/description, etc complete all specified and directed.The HT cable shall confirm to code IS -7098(Part-2) /1985 specifications. (Note : Excavation & Earth work shall be measured and paid seprately).
Excavation in trenches n.exc 1.5 m wide and n. exc 1.5 m in depth and getting out in soft/loose soil for removing/laying of cables complete all as specified and as directed by Engineer-in-charge.
Returning, filling in including spreading , leveling , watering and well ramming in layers n.exc 25 cm with soil complete all as specified and as directed by the Engineer-in- Charge.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for dry fine sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable all as direted. Note : [Punned thickness shall be measured & paid]
Supply & laying unreinforced precast cement concrete cable cover, class HV, type 1, flat , size 300 mm x 180mmx 40mm all as required as in protection of cable complete all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm 3 core with working voltage 11000 volts complete all as specified and direced Make: Denson/ M Seal / 3 M / Raychem / Cabseal
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for Indoor End termination heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm 3 core with working voltage 11000 volts complete all as specified and direced Make: Denson/ M Seal / 3 M / Raychem / Cabseal
S&F in replacement of Cable route indicator made of CI 100mm dia welded and fitted with MS angle Iron 40 x 40x 6 mm, 45 Cm long. The angle shall be grouted in PCC block 1:3:6 type C-1 (20 mmGraded aggregate) of size 150 x 150 x 150mm. The CI round shall be embossed with the work “MES HT Cables” complete all as specified and as directed.The cable path indicator shall be painded by Brown Colour.
Supply and laying Galavanised Iron Tubing pipe having bore 100mm dia of medium grade for drawing 11KV HT cable for road crossing and sewge canal etc.
Supply, Installation, testing and commissioning of indoor 11KV HT switchgear, 630A , 3 Phase, 50 Hz, 3 wire totally enclosed, prewired, both side extensible type,floor mounted, Horizantal isolation type vaccum circuit breaker (VCB) 630 Amp rating having rupturing capacity ( Max 25 KA) with copper Bus Bar , Total 4 nos outgoing feeders suitable to couple (through Bus connection only ) with existing switchgear at MES site .The panel should be tested for interal arc for 25 KA or above for 1 sec. The VCB shall comply with IS:13947(part 1 to 5 for circuit breaker),IS-2705 for C.T(Current transformer). The breaker of the offered new outgoing panels should be interchangeable with the existing breaker at S/S. Make - Schneider ( HWX) /ABB ( Unigear)/Siemens (NXAir) Imp Note- The new panel suould be suitable to couple with existing one no Incomer at site throught Bus connection only. The connection through cable or through adapter panel is not acceptable. Following items are required for outgoing feeders - (a) Panel enclosure - The panel enclosure should be made of Aluzinc . Only the front door and rearcover should be made of CRCA sheet - 1 No. (b) Mechanical inter lock and automatic safety shutter gear 1 No (c) Isolating plugs - 6 Nos (d) 11 KV, 630 Amps max 25 KA at VCB -01-No ( comprising of the following:- (i) Asssembly of 3 nos vacum inerrupters ( The make of the vacuum intrupter should be same as make of VCB) (ii) Hand and motor operated spring charged, independent starting, tripping trip free operating mechanism with manual closing and tripping push buttons.(iii) Mechanical operation counter- 1 nos (iv) Closing and Tripping coil. -1 no (v) Breaker operated auxiliary switch 6 Nos and 6 N/C (vi) Bus bar chamber including set of 3 phase 630 Amps Copper bus bar. - 01 Set (e) 230 V AC Single phase, 80W rated strip type heater-2 Nos.
(f) Current transformer chamber incorporating 3 single phase resin cast CTs of ratio 50/1 Amps with suitable VA burden and accuracy class 1 and 5P10 -01 No (g) Rear cable termination, provision for termianting cable (h) Digital Ammeter - 01 No (i) On/off/Trip indication - 01 No (j) 3 pahse RYB indication with lamps - 01 No (k) TNC Switch - 01 No (l) Trip circuit supervision healthy indication lamp - 01 No (m) Digital Multifunction meter Model EM 6400 Accuracy Class -1 - 1 no. (n) Necessasry common Power pack for switchgear (The 230 V AC supply is available at site) . (o) Numerical relay earth fault , over current having suitable protection setting range ( Schneider make) -01 no (p) One no hygrostat to be provided. (q) Temperature sensors ( battery less, wireless and sensors should be suitable to mount/place directly on the live bus connection to get the max accuracy. ) for monitoring of bus side ( RYB phase) and cable side ( RYB) temperature - 6 nos for each outgoing panel only. (r) Illumination lamp with Power socket (s) Master trip reay - 1 no NOTE : i) The breaker of the new switchgear should be interchangeable with the existing breaker at S/S. (ii) The new switchgear shall be OEM make and to be offered for Factory Acceptance Test at OEM factory. The system integrator panels are not acceptable. (iii) The make of the vacuum intrupter should be same as make of VCB.(iv) The design should have top and bottom separate arms in breaker. The breaker having single arm design with vacuum bottle in horizontal position shall not be acceptable. Vendor to quote new design of switchgear where this type of arrangeent is not applicable.
S & F synthetic insulating mat for HT 11 KV installations.The mat shall have minimum Dielectric strength of 30 KV. And confirm IS - 8437 The mat shall have dimensions 2m x 1m x 25mm.
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to copper strip of size 25x3 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to HT VCB Body or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 5 of MES Schedule Part-I and Testing on completion , complete all as specified and as directed.
Shree Ayyappa Engineering
ELECTRO ASSOCIATES
Veer High Tech Solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .