Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹40.9 L+₹2.8 L (7.26%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹41.2 L+₹3.0 L (7.92%)Rejected-AOC 315 INDUSTRIAL AREA II PANCHKULA 134113 | PANCHKULA | HARYANA | 134113 | L3 | Rejected-AOC L3 |
Tender Value
₹43.7 L
EMD Value
₹87,500
Closing Date
31 Mar 2023, 5:00 pmClosed
XEN Electrical Division No. 1 Shimla-9
The Executive Engineer Electrical Division No-1 HPPWD Shimla-9
CO various office Accommodation in Level 59.00M, Level 62.60MKJ, Level 66.60M, Level 69.80M 4th Floor at Existing Multistory Parking complex Tutikandi at Shimla SH Providing Fire Alarm and Public Addressing System therein
2023_PWD_71380_1
Electrical Division-I dated 18.03.2023
Open Tender
Electrical Works
Item Rate
365 days
SHIMLA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
E.E.Electrical Division No-I Shimla-9
₹87,500
5 Jul 2023
22 Mar 2023
1 Apr 2023
22 Mar 2023
31 Mar 2023
22 Mar 2023
Amount
Supply, Installation, Testing and Commissioning of Microprocessor based Intelligent Addressable 4 loop Main Fire Alarm Control Panel with Suitable Loops modules and each loop capable of supporting not less than 250 devices (detectors & modules should be in any combination) ; Loop length up to 1.5 km, 8" Color LCD touch screen display with bright colors to indicate alarms and events, 4 Nos of Integrated Ethernet Ports & 2 Nos of RS 485 for networking, 200 Nos of Soft programmable keys with status indicators for individual triggering of NAC Outputs, evacuation speaker zones, AHU Modules, Damper switch, Smoke extraction Fans, Lifts.. etc. The Panel shall support 10000 history logs in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 24 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel should also have IP30 or better protection. The panel shall have a built in power supply, battery charger maintenance free battery capable of running for a minimum 24 hours operation complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work. Makes: Bosch FPA 4000 Series / Cerberus by Siemens, Edwards EST3, Honeywell Morley Max Series, Autronica/ Notifire / Bosch/Simens
Supply, Installation, Testing and Commissioning of addressable multisensor smoke detector including mounting base with LED… etc. complete as required with 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements; Drift Compensation feature & Automatic addressing. Detector should monitor Electromagnetic interference and report to the panel - current and average values.Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Notifire / Bosch/Simens
Supply, Installation, Testing and Commissioning of addressable Heat detector with fixed and rate of raise feature including mounting base with LED… etc. complete as required. Each Detector should have 2 inbuilt Isolators as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. Detector should have IP40 or better protection rating. EMC safety for detector shall be 50 V/m. Shall be UL/EN/VDS certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module per detector) Make Autronica/ Notifire / Bosch / Simens -EN
Supply, Installation, Testing and Commissioning of addessable Single ACTION manual pull station & necessary fixing arrangements with key complete as required. MCP should have IP40 or better protection rating Shall be UL/EN/VDS Certified. Make Autronica/ Notifire / Bosch/Simens -EN
Supply, Installation, Testing and Commissioning of Addressable Monitor Module with 1 input, which shall monitor normally open or normally closed contacts.The module shall have an LED to indicate module status.It Shall be UL/EN/VDS Certified. Make Autronica/ Notifire / Bosch/Simens -EN
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with inbuilt isolators as per NFPA 72 style 7 wiring requirements .Relay Control module shall be used for emergency control functions including shutting down Fire dampers in AHU's, tripping of AHU's, Fresh air fans, Ventilation fans, tripping of Access control doorsetc.. Shall be EN54/ Vds Certification/UL Make Autronica/ Notifire / Bosch/Simens -EN
SITC of Intelligent Analog Addressable type Response Indicator with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work Make: Bosch/ Siemens Cerberus/ Morley/ Edward.
Supply, Installation, Testing and Commissioning of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class – 1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineerin-Charge of work Make PES/Giolite/OMEX
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 25 mm
Supply, Installation, Testing and comissioning of 18U Equipment Rack with provision for housing all control equipment with front & rear door, Blower for cooling and proper locking arrangements and as per the specifications, complete in all respect upto the entire satisfaction of Engineer - in - Charge of the work. Makes: Valrack /Netrack/ Comrack
SITC of 2KVA Online UPS : single Phase Input & single Phase Output-Autosensing, True Online UPS with Full Digital Signal Processing (DSP )Technologies with Touch Screen LCD /LED Display Panel & Pure Sine Wave O/P with high frequency. UPS unit shall operate in double conversion mode, it shall be a VFI-type UPS (as per stanard IEC 62040-3) with Inbuilt /external Galvanic ISOLATION Transformer of same OEM make only. UPS should be with 3 level IGBT Based Rectifier & 3 Level IGBT Based Inverter Technology. UPS should have minimum 15-60 minutes backup on SMF Batteries Bank with Minimum VAH = 30200 VAH along with following features/specifications
INPUT FEATURE :
Input Voltage window 180 VAC - 250 VAC 1 Phase
Input Frequency window 45-65 Hz .
Nominal Frequency 50 Hz
OUTPUT FEATURE :
Output Power Factor should be unity.
Output Power Capacity in watts (KW) 2.0 KW
Output Voltage - 230/240 Volts rms, adjustable via the user interface.
Warranty Terms :- 2 Years on UPS & 2 years on Batteries with onsite service Support
supplying 2.0 KVA on line UPS HAVING SPECIFICATION DETAILED ABOVE (1.01 to 1.06 )OF FOLLOWING Approved Make : APC- Schneider / Vertiv -Emerson/ Legrand-Numeric /Mitsubishi /GE Only .
Supply, installation, testing & commissioning of Class D amplifier 480 watts Frequency response: 60 Hz to 15 khz (+1/3db), Inputs :XLR & phone jack , Input 1, Input 2-4, Impendence :20kΩ, Sensitivity : 1 V balanced , S/N >: >85 dB as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Honeywell/BOSCH/Henrich.
Supply, Installation, Testing & Commissioning of 6W ceiling speaker 5inch with metal enclosure with Line Matching Transformer and tapping of 1.5 W / 3W and 6W as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Bosch / Honeywell / Bose.
Supply, Installation, Testing & Commissioning of 12W Wall speaker with Line Matching Transformer and tapping of 12 W and 6W as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Bosch / Honeywell / Bose.
Supply, installation, testing & commissioning of 24 U Standard rack to place all Av equipment as required to complete the job in all respect as per the entire satisfaction of Engineer In Charge. Make Valrack/ Comrack/Hive Networks.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. PVC Conduit 32/50 mm
AVNET SOLUTIONS
Insat Techno Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .