Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹41.7 L+₹1.6 L (3.88%)Rejected-Finance 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹42.1 L+₹2.0 L (4.88%)Rejected-Finance 2165 1ST STREET L BLOCK 12TH MAIN ROAD ANNA NAGAR WEST CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹49.9 L+₹9.7 L (24.2%)Rejected-Finance N0 15 ASHOK NAGAR MAIN ROAD MES ROAD 3RD CROSS STREET EAST TAMBARAM CHENNAI 600 059 | CHENGALPATTU | TAMIL NADU | 600059 | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | M/s KM Marimuthu Achary L4 | Raju Builders L2 | power links L3 | Delta Construtions L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge. | 6 | Cum | 600 ₹3,600 | 270 ₹1,620 Lowest | 413 ₹2,478 | 500 ₹3,000 |
| 2.00 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge. | 25.5 | Cum | 400 ₹10,200 | 270 ₹6,885 Lowest | 354 ₹9,027 | 600 ₹15,300 |
| 3.00 | M&L for Plain Cement Concrete Type D2 (1:4:8) Nominal mix, using 40mm graded stone aggregates as in foundation, filling and mass concrete inlcuding formwork complete all as specified and directed by Engineer-in-Charge. | 2.8 | Cum | 5,000 ₹14,000 | 4,500 ₹12,600 | 5,310 ₹14,868 | 3,500 ₹9,800 Lowest |
| 4.00 | M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge. | 25.1 | Cum | 7,000 ₹1,75,700 | 6,300 ₹1,58,130 Lowest | 8,850 ₹2,22,135 | 9,000 ₹2,25,900 |
| 5.00 | M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. | 3 | Sqm | 800 ₹2,400 | 630 ₹1,890 Lowest | 767 ₹2,301 | 700 ₹2,100 |
| 6.00 | M&L Reinforced cement concrete 1:1.5:3 Nominal mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge. | 1.5 | Cum | 7,000 ₹10,500 | 6,300 ₹9,450 | 6,136 ₹9,204 | 6,000 ₹9,000 Lowest |
| 7.00 | M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge. | 6.5 | Sqm | 400 ₹2,600 | 450 ₹2,925 | 413 ₹2,684.5 | 250 ₹1,625 Lowest |
| 8.00 | S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. | 210 | Kg | 90 ₹18,900 Lowest | 108 ₹22,680 | 94.4 ₹19,824 | 100 ₹21,000 |
| 9.00 | S&F TMT steel bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge. | 55 | Kg | 90 ₹4,950 Lowest | 108 ₹5,940 | 96.76 ₹5,321.8 | 100 ₹5,500 |
| 10.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge. | 753 | Sqm | 50 ₹37,650 | 18 ₹13,554 Lowest | 64.9 ₹48,869.7 | 50 ₹37,650 |
Tender Value
₹47.9 L
EMD Value
₹95,800
Closing Date
19 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
ADDN ALTN TO BRIEFING ROOM AND TOILETS AND OTHER MINOR REVENUE WORKS AT AFS TAMBARAM
2025_MES_721513_1
GE(AF)/TBM/8829/E8
Open Tender
Civil Works
Item Rate
180 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹95,800
Yes
8 Oct 2025
19 Jul 2025
21 Aug 2025
19 Jul 2025
19 Aug 2025
5 Aug 2025
Amount
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out hard/dense soil complete all as specified and directed by Engineer-in-Charge.
M&L for Plain Cement Concrete Type D2 (1:4:8) Nominal mix, using 40mm graded stone aggregates as in foundation, filling and mass concrete inlcuding formwork complete all as specified and directed by Engineer-in-Charge.
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced cement concrete 1:1.5:3 Nominal mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed by Engineer-in-Charge.
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed by Engineer-in-Charge.
S&F TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
S&F TMT steel bars 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
S&F glazed ceramic tiles in vertical surface 300x 450x 7mm/ 350X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match floor tile over and including a backing coat in 10mm thick Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area n.exc 1.5 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification &drawing) complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm prelam PVC Sheet on back face fixing in frame at site as per specification & drawing complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodised,125mm long barrel tower bolts of extruded section and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Extruded aluminium alloy handles,150mm long fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
S&F 100 mm long stainless steel butt hinges for PVC door complete all as specified and directed by Engineer-in-Charge.
S &F vitreous china water closet Squatting Orissa patern white size 580 x 440mm with integral foot rest with P or S trap 32mm dia polyethylene fush pipe etc compete all as specified including provn of cement concrete bedding fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Wash down water closet (Pedestal pattern) white with P or S trap including plastic water closet seat & cover mild steel chromium plated or aluminised hinging device, flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for high/low level cistern etc complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in repairs Health faucet ABS body 15mm dia pipe with 1.25metre long PVC tube with wall hook, Chromium Plated complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC valveless, syphonic action type of 10 litre capacity, flushing cistern,low level, white, with inlet, ball valve, float and handle including brackets and PVC connections of 15mm size with PTMT nuts of length 600mm etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china WHB flat back of size 550x400mm including GI Brackets, CP brass waste coupling with check nut and washers of suitable size complete all as specified and directed by Engineer-in-Charge.
M&L Bottle trap PTMT min weight 260gms half or full threaded bore of discharge pipe 32mm fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore pillar taps cast copper alloy fancy type chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed by Engineer-in-Charge.
M&L PVC corner beading for wall tilling complete all as specified and directed by Engineer-in-Charge.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms) complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceble shutters of any description not exceeding 1 sqm each complete all as specified and directed by Engineer-in-Charge.
S&F 75mm Mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engineer-in-Charge.
S & F 40mm width Continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed by Engineer-in-Charge.
S&F 75mm Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
S&F 30mm Flush shutters, solid core construction,with particle board core if one face is covered with deco rative face veneer with lipping/frame to match complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 600x450 bevelled edged looking mirror 6mm thick with Design wooden frame work fitted with 6mm thick commerical ply or AC sheet backing to mirror fixed complete all as specified and directed by Engineer-in-Charge.
S&F bevelled edged looking mirror 6mm thick with Design wooden frame work fitted with 6mm thick commerical ply or AC sheet backing to mirror fixed complete all as specified and directed by Engineer-in-Charge.
Supply and fixed in repairs towel rail 600mm long with flanges, chromium plated complete all as specified and directed by Engineer-in-Charge.
S&F Over head shower rose & shower arm with revolving joint and 100mm dia round shaped single flow (ABS body chromium plated all fixed in repair complete all as specified and directed by Engineer-in-Charge.
S&F for in repairs angular two way stop cock 15 mm bore chromium plated with crtuch or butterfly handle, fancy type with long shank screwed down both ends for pipes or for union complete all as specified and directed by Engineer-in-Charge.
S&F Stop valves 15 mm bore fancy type, CP with long shank & cup (concelaed type), cast copper alloy screwed down high presure, with crutch of butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15mm dia chromium plated fancy type angle/stop cock cast copper alloy screwed down high pressure fancy screwed both ends for pipe or for union complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 15 mm bore CP Bib tap cast copper alloy fancy type crutch or butterfly handles screwed down for iron or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Vitreous China urinals, half stall urinal complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and directed by Engineer-in-Charge.
S&F Urinal spreader of CP any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC connections 15mm dia 600mm long (for cold/hot water connection with brass or PTMT flynuts and washer at both ends complete all as specified and directed by Engineer-in-Charge.
Taking down rain water pipes, waste/soil pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc including cleaning or refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) bend without access door complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 100mm dia SS floor trap with grating incl jointing with solvent cement complete all as specified and directed by Engineer-in-Charge.
Taking down of steel tubing and connections complete on walls floors etc for 15mm bore of pipe complete all as specified and directed by Engineer-in-Charge.
All as per item No.54 above but bore of pipe in 20mm dia complete all as specified and directed by Engineer-in-Charge.
All as per item No.54 above but bore of pipe in 25mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and laying of 16mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and directed by Engineer-in-Charge.
Material and labour for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls matching existing finishes complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC downtake waste pipe,32 mm for WHB / urinals complete all as specified and directed by Engineer-in-Charge.
S&F in repairs Stainless steel wire mesh of nominal dia of wire 0.36mm and average width of aperture 1.40mm including wooden fillets/beadings, screws etc complete all as specified and directed by Engineer-in-Charge.
Taking down old cement plaster including racking out joint hacking for keys and scrubbing down with water etc., on wall/ ceiling surfaces and removing the debris from the defence premises complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10mm thick on brick/ concrete surfaces with CM 1:6, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5mm thick on ceiling surfaces with CM 1:3, finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of wall by sand papering or by any other means, preparing the surfaces smooth and after that applying three coats of lime white wash with using paint brush complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of new plastered surfaces of ceiling by sand papering or by any other means, preparing the surfaces smooth and applying three coats of lime white wash by using paint brush complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of ceiling and applying one coat of white wash evenly complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheetinclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing, Manufacturer instructions complete all as specified and directed by Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width35mm for wall paneling inclusive offixing on to wall to make PVC Frame as per specification and drawing, Manufacturer instructions complete all as specified and directed by Engineer-in-Charge.
Taking down aluminium chowkats/ frames of area exc 1.5 sqm n.exc 4.0 Sqm with shutter each complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1sqm not exc 2 sq m complete all as specified and directed by Engineer-in-Charge.
Taking down aluminium grills of area exc 1.5 sqm n.exc 4.0 Sqm complete all as specified and directed by Engineer-in-Charge.
S&F door closer, aluminium (extruded section body) hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80kg complete all as specified and directed by Engineer-in-Charge.
Material and Labour for providing and fixing factory made uPVC colourcasement window closed shuitters (composites of profiles of 60mm x 58mm x 2mm)for outer frames for two or more cloased shutters capable of mounting single glazing systemstructurally reinforced with hot dip galvanized upto 50 microns of min thickness1.2mm prefabricated welded through fusion weldingthe window sash shall be fitted with 5mm thick resistant accesories for casement window- friction stay hinges of stainless steel,per sash, handle with mazak alloy casting No.1 per sash, locking system suitably consealed 1 No., per sash with raiser wdges for smooth operation and system is to be installed at site using anchor fasteners, silicon rubber sealent, easy glazing, deglazing at site etc., with templates for casement sizing complete all as specified and directed by Engineer-in-Charge.
Material and Labour for providing and fixing factory made rigid uPVC approved coloures Door frame made of uPVC extruded sections having an overall dimensions as 110mm * 52mm with wall thickness 2mm, corners of door frame to be joined with galvanized brackets and stainless stell screws, joints mitred and Plastic welded. The hinge side vertical of frame reinf by galvanized MS tube of size 19 x 19mm and 1mm wall thickness and 3 Nos. of hinges fixed to frame completely as per direction of Engr in charge. Openable door made of multi chambered UPVC of approved coloured reniforced with Galvanized iron profile through the openable frame. Frame of 60mm x 38mm x 76mm with reinforcement of 1mm thickness and openable sash with overall size of 60mm x 76mm and reinforcement of 1.5mm thickness. Coextruded glazing bead for fixing of 6mm thick teflon clear float glass of desired make duly fixed with EPDM weathering seal resistant accessories including necessary etching of glass of approved logo and pattern all as directed. Wall thickness of frame and sash shall be 2mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs rotational moulded polyethylene water storage tanks 1000 litre capacity, ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 25mm gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repairs 25mm bore Ball brass valves,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F fixing aluminium powder coated (Minimum thickness of powder coating not less than 50 micron) frame for windows/ Doors/Ventilators/Partitions with one or more tracks including joining cleats/ channel for fixing glass/ mesh complete all as specified and directed by Engineer-in-Charge.
S&F for Powder coated (Minimum thickness of powder coating not less than 50 micron) aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed by Engineer-in-Charge. Note : Glass panes and wire mesh will be measured and paid separately
S&F Aluminium powder coated (minimum thickness of powder coating 50 micron) side hung/sliding window/ ventilators shutters (I max) of aluminium section for frame work of shutters not less than 0.55 Kg/RM including necessary jointing cleats glazing clips, rubber packing anodised aluminium snap beads, screw, roller inter locking handles including 75 mm SS Hinges-02 Nos, 125 mm handles - 01 No, 125 mm long tower bolts - 02 Nos each shutter etc complete all as specified and directed by Engineer-in-Charge. Note : Glass panes and wire mesh will be measured and paid separately
S&F stainless steel wire mesh 0.45mm nominal dia of wire and any width of aparture 1.4mm fixed with aluminium wire staples fixed to wood/steel frames complete all as specified and directed by Engineer-in-Charge.
M&L for pre laminated particle board 12 mm thick interior grade prelaminated one side with decorative choice lamination and other side balancing white lamination with lipping as in doors of cupboards and cabinets complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass 4mm thick plain ordinary quality and glazing with oil putty wooden beads as directed in squares n exc 0.50 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 10mm thick Toughened glass as in hinged doors, partitions automatic doors and similar works including cutting to shape, drilling holes required complete all as specified and directed by Engineer-in-Charge.
S&F aluminium extruded section body, door closer hydraulically regulated designation No 1 universal type suitable for door shutters upto 700mm in width and of weight not more than 35 Kg and fixed complete all as specified and directed by Engineer-in-Charge.
S&F Mild Steel 4 levers mortice lock vertical type size 100mm dia complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete floors and pavings exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness(below or above ground level) complete all as specified and directed by Engineer-in-Charge.
Removal of debris obtained from demolition/dismantling upto any distance to outside MD land complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick Plain Cement Concrete 1:4:8, Type D2 Nominal mix (using 20 mm graded stone aggregate), as in sub base complete all as specified and directed by Engineer-in-Charge.
M&L for vitrified ceramic coloured tiles light shade 10 mm thick (square / rectengular) polished area of each tile n exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1 :4 in floors etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 93 but in vertical surfaces set set and jointed in neat cement slurry over and including 10mm thick plaster in cement mortar 1:4, pointed with white/ coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 75mm plain Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) complete all as specified and directed by Engineer in Charge.
Material and Labour for Screed bed or bedding layers of mortor 20mm thick in CM 1:6 for laying tiles in floor complete all as specified and directed by Engineer in Charge.
Material and Labour for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in with grey cement and pigments in floors complete all as specified and directed by Engineer in Charge.
M&L for Rendering 15 mm thick in two coats of 1st coat 10mm thick in CM 1:6, finishing coat 5 mm thick in CM 1:4 with and including at the rate of 200ml per bag finished even and smooth with out using extra cement complete all as specified and directed by Engineer-in-Charge. Note : Liquid water proofing compound shall be inclusive in this quoted rate.
M&L preparation of new surfaces of walls and applying one coat of primer and two coats of Oil Bound Distemper complete all as specified and directed by Engineer-in-Charge.
M&L preparation of new surfaces of external walls and applying one coat of primer and two coats of weather proof exterior emulsion paint (weather coat Apex, 100% exterior grade) complete all as specified and directed by Engineer-in-Charge.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings including ridges complete all as specified and directed by Engineer-in-Charge.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per Manufacturer's instruction complete all as specified and directed by Engineer-in-Charge.
S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per Manufacturer's instruction complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
S&F Structural steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge.
M&L Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets,complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium snap grid frame work for false ceiling all as specified Size of grid 605 x 605mm complete all as specified and directed by Engineer-in-Charge.
S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed by Engineer-in-Charge.
S&F 12mm Perforated particle board/tiles for insula-tion andaccoustic purposes,60x60 cm in size, fixedwith nails to timberframework or with staple on snap grid timber/GI/Aluminium framework with screws complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable sub main wiring any description along with PVC conduit/Casing capping/wooden batten/metal conduit and making the disturbed surface good matching existing finish complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable DB/.metal clad boxes any description or size/way incl MCCB/MCBs complete all as specified and directed by Engineer-in-Charge.
Taking down Exhaust fan, ceiling rose, dismantling blades and removing fan and blades to store, depositing serviceable one for reuse and Unserviceable fans for BER process complete all as specified and directed by Engineer-in-Charge.
Refixing only Exhaust fan (MD supply) and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
M & L for painting of ceiling fan/exhaust fan of any sweep, complete in situ, with one coat of synthetic enamel paint by spraying including filling cavities with filler after cleaning all dust etc, preparation of surfaces and finally writing MES NO in appropriate format complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable aluminium point wiring (light, fan, socket or power) complete fittings such as switches,sockets,ceiling rose, pendents, regulators etc complete as ordered and removing retrived materials and making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-Charge.
M/L for point wiring concealed type of One light point controlled by one switch with 1.5 sqmm PVC FRLS insulated,un-sheathed 1100 volts grade copper conductor single core multi stranded drawn through with and including non metallic rigid PVC rigid conduit not less than 20 mm dia with its accessories concealed on walls, suface on ceiling etc., with suitable clamps/ shaddles, including provision of suitable 1.6 mm thick MS pressed steel terminal boxes concealed suitable to modular sockets/switches including modular cover frame and plate in wall for housing of modular switiches, sockets, fan regulators etc., including one run of 1.50 sqmm PVC insulated FRLS copper conductor for continious earth wire and connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
All as per item No.117 but for One fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.117 but for One socket point on Independent board complete all as specified and directed by Engineer-in-Charge.
All as per item No.117 but for One socket point on same board with other switches complete all as specified and directed by Engineer-in-Charge.
All as per item No.117 but with 2.5 sqmm for power point 15 amps complete all as specified and directed by Engineer-in-Charge.
All as per item No 117 above but with 4.0 sqmm for AC point socket outlet 15 amps complete all as specified and directed by Engineer-in-Charge.
S&F Modular Switch flush type, 6 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch flush type 6 Amps, Single Pole Two way complete all as specified and directed by Engineer-in-Charge.
S&F Modular Switch flush type, 16 amps 240 volts single pole one way complete all as specified and directed by Engineer-in-Charge.
S&F Ceiling rose surface PVC insulated three plates "JUMBO' type 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket outlet 2/3 pin 6 amps 240 volts flush type, two module complete all as specified and directed by Engineer-in-Charge.
S&F Modular socket out let 6/16 Amp 6pin flush type, two module complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Wall mounted light fitting LED batten, extruded aluminium heat sink provided for effcient heat dissipation & integrated electronic driver with 22 W LED (4 ft) lamp including disconnecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. Make - Havells/ Philips/ CG
S&F LED lights fitting 1x 20W, 220V, Suspended architectural LED luminare provides soft-light and glare free symmetrical illumination with (continuous mounting end cap connecting up with three core flexible copper conductor including disconecting, removing and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. Make - Havells/ Philips/ CG
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Mirror light fitting LED luminares New generation energy saving IP65 Mirror light luminaire with opal diffuser with 10W LED including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. Make - Havells/ Philips/ CG
S&F in replacement of security light fitting LED luminares New generation energy saving & environmental friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LED as light source with 35W LED 5000K lamp including disconecting, removing, and connecting into electric circuit and testing complete all as specified and directed by Engineer-in-Charge. Make : Havells/ Philips/ CG
S&F GI Bracket bend to shape in cold or hot 40mm bore medium grade and 1.50 M long with suitable MS clamps and nuts bolts etc, to fixing security light fittings to Bldgs complete after taking down the unsv GI bracket complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring two run of 6 sqmm single core PVC insulated unsheathed FRLS cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 6 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring two run of 10 sqmm single core PVC insulated unsheathed cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 10 sqmm PVC insulated copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete one single pole MCB 20/30 Amps, 240V complete concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 8 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections all as directed by Engr in charge
Supply & fixing of Sheet metal enclosure with distribution board Double Door 230 volts SPN 12 way with suitable Bus bar and provision for MCBs/ isolators fixed on wall and connecting with all connections all as directed by Engr in charge
Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 8 ways double door type including 125 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
Supply & fixing of Vertical type sheet metal enclosure MCB DB TPN 4 ways double door type including 63 Amps MCCB 4 Pole 415 V,16 KA incomer with suitable bus bar surface/ concealed on wall and connecting with all connections complete all as specified and directed by Engineer-in-Charge.
S & F MCB Single pole 6-32/40 amps, breaking capacity 10 KA , SP 240V complete all as specified and directed by Engineer-in-Charge. Make : Havells ,Cat Part No :DHMGBSPF006-035 or Equivalent in Legrand/ Halonix
S & F MCB 'B' curve SPN 6-32/40 Amps, breaking capacity 10 KA , 240Volts complete all as specified and directed by Engineer-in-Charge.
Supply and fix wall mounted fan 400 mm sweep esteem type along with speed control complete with all accessories including mounting fabricated MS flat and anchor fastner nuts and bolts all as per design given by Engr-in-Charge complete all as specified and directed by Engineer-in-Charge. Make:Havells/ USHA/CG
Material and labour for earthing complete with GI plate electrode 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below ground level connected to earth lead of 4.0 mm GI wire means of bolts, nuts, washers of galvanized all as shown in electrical plate No.3 of SSR Part-I including necessary excavation and earth work. PCC 1:3:6 type C1 chamber, RCC cover in 50mm thick 1:2:4 type B1 with 8mm CTD 140mm centre to centre with suitable handle, watering pipe 20mm dia light grade pipe with funnel, charcoal salt connected to earthing test point all as specified including testing and commissioning on completion complete all as specified and directed by Engineer-in-Charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire 4.0 mm thick for inter connecting of earth electrodes complete all as specified and directed by Engineer-in-Charge.
S&F PVC non metallic rigid conduit not less than 20 mm dia with its conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
S&F modular White cover plate with frame, 1 module complete all as specified and directed by Engineer-in-Charge.
S&F modular Metal flush box 1 module complete all as specified and directed by Engineer-in-Charge.
S&F modular telephone socket 1 module complete all as specified and directed by Engineer-in-Charge. Make - Havells/ Legrand/ Crabtree
S&F modular TV/LAN socket 1 module complete all as specified and directed by Engineer-in-Charge. Make - Havells/ Legrand/ Crabtree
Supply and fixing in repair Isolator TP 63Amps, 10KA 240volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Taking down Split AC up to 2.0Ton complete with indoor & out door units and depositing the same safely to E/M store for safe custody including electrical connections complete all as specified and directed by Engineer-in-Charge.
M&L for refixing the split AC up to 2.0Ton collecting the same including connection from E/M store after the completion of B/R work including necessary servicing, top up of refrigerant gas and replacement of minor spares if required, welding, brazing complete all as specified and directed by Engineer-in-Charge.
Dismantling of aluminium Sliding door (without taking off shutters from the frame) and rrefixing the same in other location as directed by the engineer in charge
Dismantling of aluminium partition along with the frames, glass and particle board and refixing the same in other location as directed by the engineer in charge
M&L preparation of new plastered surfaces of walls and applying two coat of oil bound distemper evenly over a coat of primer complete all as specified and directed by Engineer-in-Charge.
M&L Reinforced Cement Concrete type B1,1:2:4 Nominal mix (using 20mm graded aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge.
S&F formwork to soffits of suspended slabs (flat/curved) such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engineer-in-Charge.
M&L Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engineer-in-Charge.
S&F 75mm brass handles, cast type, polished bright complete all as specified and directed by Engineer-in-Charge.
S&F 75mm Mild steel, magnetic door catches complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thickness Plain cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate),as in levelling course of floors etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for preparation of old surfaces of ceiling by sand papering or by any other means, preparing the surfaces smooth and after that applying three coats of lime white wash with using paint brush complete all as specified and directed by Engineer-in-Charge.
M&L preparation of old decorated surfaces of wood work exc. 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing Old Steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing surfaces plastered or unplastered of Old surfaces of wall, Distempering walls with distemper dry, white or tinted complete all as specified and directed by Engineer-in-Charge.
M&L Plain Cement Concrete Type C2 (1:3:6) Nominal mix using 40mm graded stone aggregates as in foundation, filling etc using necessary formwork complete all as specified and directed by Engineer-in-Charge.
M&L for 40 mm thick Plain Cement Concrete 1:2:4, Type B1 (using 20 mm graded stone aggregate), for ramps, as in flooring finishing cement concrete surface even and smooth without extra cement complete all as specified and directed by Engineer-in-Charge.
Supply and install hi wall split units 2.0 TR indoor/outdoor complete with cordless remote control unit and with in built air ioniser for better indoor air quality with minimum 5 star rating inverter type and R-32 6200 watts,BLDC Compressor,Anti bacterial filter,dust filter,copper condensing coil,BERE:ISEER: 5.0w/w complete all as specified and directed by Engineer-in-Charge. Make: Votas/Carrier/Daikin Note:- Minimum 5years Warranty on compressor & PCB Board shall be produced by contractor in a Rs 100/- Non judicial stamp paper duly notarized to the GE.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0 .5 KVA complete all as specified and directed by Engineer-in-Charge.
M &L Point wiring with 1.5 sqmm sigle core PVC insulated FRLS 1100 volts grade with copper conductor drawn in and steel conduit and all conduit accessories provision of MS terminal box suitable for flame proof switch etc, including 1.5 Sqmm PVC insulated multistranded FRLS copper earth continuity conductor connecting to the common earth dolly etc complete for the following:-
One light/Fan point controlled by one switch
One 3 pin 5 Amps socket outlet on same board
One 3 pin 5 Amps socket outlet on independent board
One 3 pin socket outlet 15 Amps independent with cable 2.5 Sq mm size.
One 3 pin socket outlet 15 Amps independent with cable 4 Sq mm size. For AC
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+earth for AC complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper onductor cable with suitable size complete all as specified and directed by Engineer-in-Charge.
S&F Rigid non-metallic of size 25mm PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks complete all as specified and directed by Engineer-in-Charge.
S&F PVC Junction boxes (1 to 4 way) including fixing screws on the wall surfaces complete all as specified and directed by Engineer-in-Charge.
M & L for circuit/sub main wiring complete with 2 X 10 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through Steel conduit and accessories on surface of wall roofs etc with 2 X 10 Sqmm of PVC FRLS copper cable for earth continuity all as specified , dismantling existing circuit/ sub main wiring and making good disturbed portion complete all as directed by Engineer- in- charge.
Supply and fixing for MCB SP 06 to 32 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing MCB SPN 40-63 Amps, 10KA 240 volts,50Hz complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab and tiles of any description laid, bedded and pointed in any mortar complete all as specified and directed by Engineer-in-Charge.
S&F Non - skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. over and including 15 mm thick screed bed in Cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats/Frames of area exc 1.5 sqm n.exc 4.0 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
Taking down aluminium chowkats/Frames of area exc 1.5 sqm n.exc 4.0 Sqm with shutter (without taking off shutters from the frame) each complete all as specified and directed by Engineer-in-Charge.
S&F Stainless steel wire mesh of nominal dia of wire 0.36mm and average width of aperture 1.40mm & fixed with stainless steel wire staples including wooden fillets/beadings, screws etc complete all as specified and directed by Engineer-in-Charge.
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl 10 mm thick backing coat in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Granite edge moulding to 18-20 mm thick stone of counter vanities etc incl machine polishing to edge to give high gloss finish etc complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring two run of 4 sqmm single core PVC insulated unsheathed FRLS cable single core multistranded copper conductor 1100 volts grade drawn through suitable size of PVC conduit and conduit accessories concealed on floor/wall/ surface on ceiling with suitable clamps/saddles including one run of 4 sqmm PVC insulated FRLS copper cable for continuous earth conductor connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply and fixing electrically operated heavy duty Chimney/ Hood, wall/ ceiling mounted type, width minimum 1200mm, suction 2800 cum/hr, heat auto clean, baffle filter, speed adjustment, complete with exhaust arrangement, single or multiple unit to meet the site requirement complete all as specified and directed by Engineer-in-Charge.
Raju Builders (BID ID -3399132)
power links (BID ID -3391408)
M/s KM Marimuthu Achary (BID ID -3396289)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .