Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹28.2 L+₹23,612.51 (0.84%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹28.9 L+₹92,643.26 (3.31%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
Closing Date
10 Mar 2021, 6:00 pmClosed
GE GOLCONDA
GE GOLCONDA LANGERHOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA
PROVN OF TOILET BLOCK 02X BATHROOM AND 12 WCS NEAR BUILDING NO E-37 AT 1 TRG REGT OF ARTY CENTRE AND CERTAIN REVENUE AND MINOR UNDER AGR BR GOLCONDA AND AGE BR HYDERABAD UNDER GE GOLCONDA
2020_MES_406584_2
GE/GOL/Token No. 19 of 2020-2021
Open Tender
Civil Works
Item Rate
270 days
GE GOLCONDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Exempted
10 Apr 2021
19 Feb 2021
12 Mar 2021
19 Feb 2021
10 Mar 2021
25 Feb 2021
20 Feb 2021 - 23 Feb 2021
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft/loose soil all as specified and directed.
Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in hard/dense soil all as specified and directed.
Excavation over areas not exceeding 1.5 M deep and getting out in hard / dense soil all as specified and directed.
Excavation over areas exceeding 1.5 M and not exceeding 3 M deep and getting out in hard / dense soil all as specified and directed.
Returnng, filling in, soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
Labour only for Earth filling under floors including spreading, levelling in layers not exceeding 25cm thick and well ramming including watering as required all as specified and directed. Note: Serviceable earth obtained from excavation shall used for filling.
M&L for hardcore using broken stone or boulders not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface all as specified and directed.
M&L Plain cement concrete (1:4:8) type D2 (40mm graded stone aggregate) in foundations, filling and mass concrete all as specified and directed.
M&L for pre-cast Reinforced cement concrete (1:2:4) type B1 (20 mm graded stone aggregate) as in cover slabe for manholes etc., and set in cement mortor (1:4) all as specified and directed. Note: Reinforecement will be measured and paid separately.
M&L for Plain cement concrete (1:3:6) type C1 (20 mm graded stone aggregate) as in coping, benching, bed blocks, cills etc., including necessary form work , complete all as specefied and directed.
M & L for Reinforced Cement Concrete (1:2:4) type B1 (20 mm graded stone aggregate) in foundations including rafts, footings and mass concrete, foundation beams, plinth beams, bases for columns, basement slabs etc., complete all as specified and directed.
M & L for Reinforced Cement Concrete (1:2:4) type B1 (20 mm graded stone aggregate) in Columns, posts and struts, complete all as specified and directed.
M&L for Reinforced cement concrete (1:2:4) type B1 (20 mm graded stone aggregate) in lintel bands, roof beams and cantilevers etc., all as specified and directed.
M&L for reinforced Cement Concrete (1:2:4) type B1 (20 mm graded stone aggregate) Chajjas, all as specified and directed.
M&L for Reinforced Cement Concrete (1:2:4) type B1 (20 mm graded stone aggregate) slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves etc., complete all as specified and directed.
M & L for pre-cast reinforced cement concrete (1:2:4) type B0 (12.5 mm graded stone aggregate) 40 mm thick Jallies or louvers including all mouldings and set in Cement Mortar (1:4), complete all as specified and directed.
Supply only integral water proofing compound
M&L Brick work with fly ash bricks built in cement mortar (1:6) straight or curved on plan exceeding 6 mtr mean radius all as specified and directed.
M & L Brick work with fly ash bricks, half brick thick wall, straight or curved on plan to any radius built in cement mortar (1:4) complete, all as specified and directed.
M&L for Walling of random rubble masonry, coursed (Secunderabad type), well bonded, bedded and solidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Use & waste formwork to sides of concrete foundations, rafts, footing, base of columns, raft and raft beams, sides & soffits of foundation (if any) of foundation and plinth beams and similar work, flat, rough finished surfaces, complete all as specified and directed.
Use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves etc., flat rough finished surfaces, complete all as specified and directed.
Use & waste of form work to columns, posts, struts and stanchions etc., Square, rectangular or polygonal, flat rough finished surfaces, complete all as specified and directed.
Use & waste of form work to chullah hoods,chajjas, troughs and similor items including edges, complete all as specified and directed.
Use & waste of formwork to sides and soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface, complete all as specified and directed.
Use & waste of formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings ,openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exceeding 20cm wide rough finished surfaces, complete all as specified and directed.
S&F for solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, suppling and fixing as per specification and drawing all as specified and directed.
S & F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed.
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections, exposed suface with precoated capping, main tee and cross tee of size 24x32mm at every 1200mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 2mm dia pre-straightened GI wire at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear side aluminium foil and front side PVC lamination, complete all as specified and directed.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete.
S & F Mild steel framed work such as grills, gratings, framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, screen for septic tank and similar work confirming to Fe 290. Gde-E-165 all as specified and directed.
M&L Figured, pin headed type, 3mm thick, glazing with oil putty in squares not exceeding 0.5 Sqm in each pane all as specified and directed.
S&F for 100 mm long extruded Aluminium alloy butt hinges with galvanised mild steel hinge pin and fixed complete all as specified and directed.
S&F for 150mm long aluminium anodized barrel tower bolts of extruded section and fixed.
S&F for 150 mm long alluminium alloy anodized handles fabricated type
S & F for tubular towel rail 20 mm dia ‘D’ type, 60 cm long between flanges of brass chromium plated.
S&F Mild steel TMT bars 6 to 8mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips) complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length bent to shap required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F Mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips) in spacers, stirrups and binders complete all as specified and directed.
S&F Collapsible steel gates, sliding type, consisting of channel pickets, pivoted flat bars, top and bottom runners, MS handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
S & F for rungs, bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples, hains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed.
M&L Plain cement concrete (1:4:8) type D2 (40mm graded stone aggregate) 75mm thick as in sub base of flooring/hardstanding complete all as specified and directed.
M& granite (of any type) work 20 mm thick (table rubbed & polished) in steps, jambs, pillars, window cills, cooking plateforms, shelves and like in laid over and incl 15mm thick screed bed in CM 1:4 including pointing in white cement (1:2) using granite dust with admixture of pigment to match with granite shade complete all as specified and directed
M&L for chequred cement concrete tiles 25 cm x 25 cm x 25 mm thick with grey cement and pigment, machine pressed : set, jointed and pointed in neat cement slurry, laid over including 15 mm thick screed bedding layer in cement mortar (1:6) all as specified and directed.
M&L Plain cement concrete (1:2:4) type B0 (12.50mm graded stone aggregate) 25mm thick, as in floor complete all as specified and directed.
M&L Plain cement concrete (1:2:4) type B1 (40 mm graded stone aggregate) 75mm thick, as in floor finished even and smooth without using extra cement complete all as specified and directed.
S&F for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6), tiles jointed in neat cement slurry and pointed with white cement mixed with pigment to match the colour of tiles all as specified and directed.
S&F for glazed ceramic coloured tiles of size 300x200x7mm thick for vertical surfaces as in dado/skirtings set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles laid over and including backing coat in cement mortar (1:4), 10mm thick all as specified and directed.
M & L 75mm thick Plain Cement concrete (1:3:6) type C2 (using 40 mm graded stone aggregate ) as in plinth protection finished even aned smooth without using extra cement, complete all as specified and directed.
M&L for Rendering 15mm thick in cement mortar (1:4) mixed with water proofing compound on fair faces of brick work / concrete surfaces finished even and smooth without using extra cement, complete, all as specified and directed. Note: Supply only water proofing compound will measured and paid separately.
M&L Rendering 10mm thick on brick work or concrete surface as on walls in cement mortar (1:6) and finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5 mm thick in ceilings with cement mortar (1:3) and finished even and smooth without using extra cement, complete all as specified and directed.
M & L for Preparation of new plastered wall surfaces and apply three coat of white wash, complete all as specified and directed.
M & L Preparation of new plastered ceiling surfaces and apply three coats of white wash, complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and apply two coats of cement based paint over a coat of cement primer all as specified and directed.
M&L for Rendering 15mm thick in cement mortar (1:4) on fair faces of brick work / concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.
M&L for keyed pointing in CM 1:4 to random rubble masonry, uncoursed or brought upto course
M&L Preparation of new steel surfaces of area exceeding 10cm width & girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
M&L Preparation of new or previously untreated steel surfaces of any description, not exceeding 10 cm width or girth, not otherwise described and apply two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and directed.
M&L cement concrete1:2:4, type B2, using 40mm aggregate in surface channel and drains etc. as specified and directed.
M&L for salt glazed stone ware drain pipes, 200 mm internal diameter of the pipe, grade 'A', laid in trenches and jointed in CM 1:1 and tested all as specified and directed.
M&L Plain cement concrete(1:4:8) type D2(40mm graded stone aggregate) as bed to drain pipes, 200 mm bore dia, including packing under,and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed.
M&L for salt glazed stone ware drain pipes, 150 mm internal diameter of the pipe, grade 'A', laid in trenches and jointed in CM 1:1 and tested all as specified and directed.
M&L Plain cement concrete(1:4:8) type D2(40mm graded stone aggregate) as bed to drain pipes, 150mm bore dia, including packing under,and haunching against the sides of pipes after they are laid and tested; complete all as specified and directed.
Cutting into existing manhole for connecting new drain of 200 mm bore pipe, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1, smooth finished, reforming benching as required.
S & F for vitreous china squatting pan (Orissa pattern) size 580 X 440mm white with integral foot rest, P or S trap including PVC flush pipe 32 mm dia complete all as specified and directed.
S & F of PVC valveless, syphonic action type, flushing cistern, dual operated type, 10 ltr capacity, low level, white with inlet ball valve float and handle including brackets, with 32mm dia PVC pipe, complete all as specifeid and directed.
S&F for 15 mm dia PVC connections with PTMT nuts of length 450 mm, with check nuts complete all as specified and directed.
S & F stainless steel sink made out of 1 mm thick stainless steel sheet, kitchen type, with plug,washer and waste, incl fixing with cantilver brackets and connecting union to pipe over all size 495x420mm, bowl size 410x 330 x 160mm, single bowl.
S&F for stop valve/angle cock 15mm bore cast copper alloy chromium plated and cup screwed down high pressure with crutch and butter fly handle screwed both end for iron pipes or for unions and fixed.
S&F for fancy CP bib tap15 mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F Rotational moulded polyethylene water storage tanks, of capacity 1000 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I, complete all as specified and as directed
S&F Bib taps, suitable for 15 mm bore cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed down, screwed for iron pipe long body and fixed complete all as specified and directed (Weight not less than as specified in SSR)
S&F 20 mm dia Ball valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball screwed for iron pipe, (Min wt 210 gms) complete all as specified and as directed.
S & F 40 mm Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to stainless steel sink ,walls, ceilings or in floors etc.
S&F 125mm dia brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union
S&F steel water tubing, ‘medium grade’ galvanised, 15mm bore including all fittings to walls and ceilings or laid in floors, complete all as specified and as directed.
S&F steel water tubing, ‘medium grade’ galvanised, 20mm bore including all fittings to walls and ceilings or laid in floors, complete all as specified and as directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe 20mm bore including taking down existing complete all as specified and as directed.
S & F for 110 mm PVC (SWR) junction single (Single T) equal or unequal with access Door.
S & F for 110 mm PVC (SWR) bends any radius all as specified and directed.
S & F for 110 x 75 mm PVC (SWR) reducer
S & F for 75mm PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors / walls
S & F PVC (SWR) vent cowl 110mm dia.
PVC (SWR) floor trap 75mm dia, plain with gratings including jointing with solvent cement
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors for 110mm bore.
M & L for APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/Sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by forced application and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over finished with one coat of alluminium paint @ 100 ml/Sqm 10cm overlap fused uniformly by LPG torch flame including 15mm thick screed in CM 1:4 mixed with WPC finished even and smooth with out using extra cement on concrete surfaces, complete all as specified and directed by Engineer-In-Charge. (Make: IWL/STP/TIKKITAR)
S & F for Asbestos cement pipes 100mm dia in any length with cement joints; fixed to walls / slab as vent pipe
S & F for AC Slotted vent cowl 100 mm dia.
Demolition of cement concrete un reinforced in floors and pavings n. exc 15 cm thickness below or above ground level, complete all as specified and directed
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'A' complete all as specified and directed.
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including PVC rigid conduit with all fittings for concealed type on stone / brick ,masonary walls, roof etc including in new MS sunk box of required size and all as directed by Engineer-in-Charge & 2 mm thick plastic laminated sheet for housing switches sockets, regulators etc, including running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified and directed at site.
All as per item No. 96 hereinbefore but for One 3 pin 5 / 6 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No. 96 hereinbefore but for One 3 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed.
M&L switch piano flush type single pole one way 5 Amps complete all as specified and directed.
M&L lamp holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminais complete all as specified and directed.
Supply and fixing LED BULB 7W AC 240V Complete all specified and directed
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, complete all as specifide and directed.
M&L switch socket combination flush type 5 Amps Multipurpose 2 in 1, 3 pin/2 pin with porcelain base all as specified and directed.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 5 Amps and 15 Amps Complete all specified and directed.
S&F MCB single pole and neutral 40 Amps 240 Volts complete all as specified and directed.
S&F MCB single pole and neutral 240 Volts 6 to 32 Amps complete all as specified and directed.
S&F LED Building security lights New generation energy saving & enviromental friendly long life versitile pressure die cast aluminum roadway luminarie with high power LED 20 watts as light source and electronic driver bracket made into required shape for fittings complete with MS clamp, nuts and bolts and washsers as required at site of minimum 1.5 mtr long Med grade GI pipe 40 mm dia including painting with one coat of primer and two coat of aluminium paint complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge o the plate not less1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provn of PCC cover 40 mm thick 1:2:4 mm type B1 funnel with water Pipe, GI pipe, 15mm dia medium grade protection pipe, GI earth lead complete all as specified and directed by the Engr-in-charge.
Supply, fixing and testing exhaust fan heavy duty type single pahse 230 volts 50 Hz of 230 mm sweep SP Turbojet of 1400 RPM with metal body and blade with louvers, frame complete all as specified and directed.
S&F LED tube light fittings 1 x 20 W, 230V, complete with all accessories internally prewired and including LED Tube rod connecting up with twisted flexible PVC copper conductor cable of 23/0.0076 from ceiling rose all as specified and directed by Engineer in charge.
Supply and lay in trenches / fixed to pole/ walls etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured UG cable with aluminium conductor 2 core 10 Sqmm complete all as specified and directed.
M&L for brick protection cover using old size bricks, sub class B, laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10mm complete all as specified and directed.
M&L for 40mm dia GI pipe laying, fixing complete including all fittings light grade for protection of UG cable complete all as specified and directed.
Supply and spreading river sand in trenches for cables cushioning on top and bottom of cables all as specified. Note :- Punned thickness shall be measured and paid.
S&F 20mm dia gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed at site.
S&F 40mm dia gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed at site.
Cutting/Boring on the existing GI pipe line of 80mm dia (in position) for insertion of new galvanised Tee 80 x 40 mm for branch connection incl necessary jointing material complete all as specified and directed.
M&L for construction of valve chamber 900x900x900mm with PCC 1:4:8 type D2 for foundation, brick wall in CM 1:4, PCC 1:2:4 type B1 for copingn rendering in CM 1:4 15mm thick for internal surfaces incl coping concrete, MS cover using 2mm thick MS plate with necessary angle frame hinges welded to it and applying 2 coats of synthetic enamle paint over a coat of red oxide primer including necessary locking arrangement complete all as specified and directed.
M&L 40mm bore galvanized steel water tubing, medium grade including all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc complete, laid in trenches all as specified and directed at site.
M&L 20mm bore galvanized steel water tubing, medium grade including all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions etc complete, laid in trenches all as specified and directed at site.
Sumpoorthy Engineers
BUILDWEL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .