| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.3 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹37.2 L+₹35,325 (0.96%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹37.4 L+₹55,575 (1.51%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹37.9 L+₹1.0 L (2.81%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹38.9 L+₹2.1 L (5.69%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
12 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER I Rnd D WEST BANGALORE
GARRISON ENGINEER I RndD WEST BANGALORE DRDO COMPLEX CV RAMAN NAGAR BANGALORE
CERTAIN REPAIRS TO INTERNAL ELECTRICAL WIRINGS FITTINGS FIXTURES AND CONNECTED WORKS AT LRDE OTM AREA UNDER GE I R ND D WEST BANGALORE
2024_MES_672983_1
GE(I)/R ND D (WEST)/BAN/TOKEN/83 OF 2024-25 8342/E8
Open Tender
Civil Works
Item Rate
180 days
Work
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I Rnd D WEST BANGALORE
₹77,000
21 Dec 2024
13 Sept 2024
18 Oct 2024
14 Sept 2024
12 Oct 2024
29 Sept 2024
14 Sept 2024 - 28 Sept 2024
Amount
Taking down old defective concealed Sheet metal main panel boxes along with existing DBs MCCBs/MCBs etc as per existing on the site by disconnecting Incoming UG cables of any size and out going circuits of armoured cables / aluminium / copper cables / circuits of any size as existing on site and kept a side carefully, provide a temporary supply arrangements to connected areas of the electric panel and making good damaged portions complete to match with the adjacent surfaces complete all as directed by Engineer-in-charge.
Fabricate, supplying, istallation , testing and commissioning wall mounted LT panel board indoor type made out of not less than 2 mm CRCA sheet fabricated from CPRI certified validated panel manufacturer with dust and vermin proof hinged double shutter doors pad locking system - 02 Nos, panel locks top and bottom, with neoprene rubber gasket powder coated including provision of danger plate,provn of earth strip- interconnected inside of the panel and provn of nut bolt system-2nos on both sides of the panel for connecting external earth strip, bottom detachable gland plate complete with suitable size zinc chromium plated nuts bolts washers etc Indoor type panel board suitable for 3 ph 4wire 415 Volts 50 Hz alluminium lugs for reconnecting IN/OUTgoing cables with lugs glands as per site conditions in and including suitable size MS flat and angle for properly fixing panel on the wall and comprising the follwing items complete all as directed by Engineer-in-charge. Location - CEMEC BUILDING (i) Incomer:- (a) 250A 4P 25KA TM BASED MCCB WITH O/L S/C RELEASE – 01 No (b) LED type RYB indication lamps with control MCB's - 1 set (c) VAF Meter digital type 96 Sq. mm - 01 No with CT's 200/5A, CL-1, 5VA - 3 Nos. (ii) Outgoing:- 32 A SP 10KA MCB C CURVE 20 Nos (ii) 63 A TPN 10KA MCB C CURVE 4 Nos (iii) 40 A TPN 10 KA MCB C CURVE - 08 Nos (iv) 300A Aluminium Bus Bar TPN and Associated Accessories as required - 01 Set
Disconnecting Incoming cable and all out going cables of any sizes from the panel carefully,, taking out all cables carefully as per site conditions and kept a side for reuse and reconnections in the new panel as per site requirements, taking out existing old panel from the site carefully complete all as directed by Engineer-in-charge. , Note - Earth work and PCC work as applicable shall be measured and paid seprately. Location - Vajra bldg Second Floor
Taking down old / defective point wiring of any surface type (light, fan, socket or power) from the existing locations complete including fixture and fittings such as sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following surface type in and including new PVC conduit medium grade of any size, complete with all PVC conduit and accessories/ fittings, brass screws, washers etc, along with suitable factory made Sunken boxes concealed suitable for modular type in the existing place or new location including all cutting/chases as applicable etc to accomodate modular plates, covers modular switches & sockets etc in walls, in and including PVC insulated copper earth continuity stranded conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly complete, making good the disturbed surface of wall, floors, ceiling etc complete all as specified and directed by Engineer-in-charge for One light point controlled by one switch.
All as per item No 6 here above but for One fan/exhaust point controlled by one switch.
All as per item No 6 here above but for One 5 Amps socket point on same board with other switches
All as per item No 6 here above but for One 5 Amps socket point on independent board
All as per item No. 6 here-in-above but wiring complete with 2.5 Sqmm for 3 pin 15A socket multipurpose on independent board.
Taking down carefully existing old / unserviceable / burnt point wiring of any type (light, fan socket or power) complete from concealed conduits of MCB circuit and controlling switch board to light fitting/fan/socket etc including taking down fixture and fittings such as sunken boxes, laminated sheets along with switches, sockets, regulators, ceiling roses etc. removing materials and making good disturbed surfaces of walls, floors, ceiling etc to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge..
Material and Labour for wiring with 1.5 sqmm FRLS grade single core PVC insulated, unsheathed, 1100V grade copper multistranded conductor for the following drawn through in the existing concealed of any dia in walls, roofs floors etc , along with suitable factory made Sunken boxes concealed in the existing place or new location including all cutting/chases as applicable etc to accomodate modular plates, covers modular switches & sockets etc including brass screws, washers etc in walls with PVC insulated copper earth continuity stranded conductor 1.5 Sqmm FRLS cable green colour connected to common earth dolly as applicable complete all as specified and directed by Engineer-in-charge. Note : (i) Cutiing chases / grooves and PVC conduit as applicable shall be measured and paid separately under relevent item for concealed conduit block portions during new wiring works all as per site and as directed by Engineer-in-charge. for One light point controlled by one switch.
All as per item No 12 here above but for One fan/exhaust point controlled by one switch.
All as per item No 12 here above but for One 5 Amps socket point on same board.
All as per item No 12 here above but for One 5 Amps socket point on independent board.
All as per item No.12 here-in-bove but wiring complete with 2.5 Sqmm for 3 pin 15 Amp socket multipurpose on independent board.
Supply & fixing modular switch 6 Amps 1 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular socket 06 Amps 5 pin 2 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular switch 16 Amps 1 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing modular socket 06/16 Amps 6 pin 2 module complete all as specified & directed by Engineer-in-charge.
Supply & fixing 2 module dimmer step type electronic fan regulator 120W complete all as specified and directed by Engineer-in-charge
Material and labour for replacement Single pole and neutral enclosure with a Three pin (as per site requirement) and earth plug and socket industrial complete with one single pole MCB 20 Amps 240 V 10 KA C series on wall complete all as per site requirements as directed by Engineer-in-charge,
Material and labour for replacement Triple pole and neutral enclosure with a Six / Five pin (as per site requirment) and earth plug and socket industrial complete with one Triple pole and neutral MCB 32 Amps 4105V 10 KA C series on wall complete all as per site requirements as directed by Engineer-in-charge,
Taking down existing concealed MCCB/MCB TPN 4 Way DBs horizontal type complete and disconnecting MCCBs/ MCBs of any type carefully set a side for reuse in the new DBs as per site conditions complete all as directed by Engineer-in-charge,
Supply, fixing, connections and testing Double door MCB DB TPN 8 Way vertical Type suitable for MCCB as incomer and MCB TPNs as outgoing in and including cutting, grooving works as applicable in the site, making good to match with the adjoining surfaces of walls complete all as directed by Engineer-in-charge,
Fixing and connections only 3 Phase MCCB 415 V TPN 100 Amps as obtained against item No. 24 here-in-above all as directed by Engineer-in-charge,
Fixing and connections only 3 Phase MCB 415 V TPN up to 100 Amps as obtained against item No. 24 here-in-above all as directed by Engineer-in-charge,
Material and labour for submain wiring with Three run of single core PVC insulated cable copper conductor multi standed of size 4.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories and taking down old existing aluminium or copper old/defective submain wiring of any size complete all as specified and directed by Engr-in-charge. Note: Three run of 4sqmm cable including taking down shall be measured as one unit.
Material and labour for replacement submain wiring with Three run of single core PVC insulated cable copper conductor multi standed of size 6.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories and taking down old existing aluminium or copper old/defective submain wiring of any size complete all as specified and directed by Engr-in-charge. Note: Three run of 6 sqmm cable including taking down shall be measured as one unit.
Material and labour for replacement submain wiring with Three run of single core PVC insulated cable copper conductor multi standed of size 10.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories and taking down old aluminium existing submain wiring complete all as specified and directed by Engr-in-charge. Note: Three run of 10 sqmm cable including taking down shall be measured as one unit.
Material and labour for replacement submain wiring with Six run of single core PVC insulated cable copper conductor multi standed of size 6.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories and taking down old existing aluminium or copper old/defective submain wiring of any size complete as per site requirements all as specified and directed by Engr-in-charge. Note: Six run of 6 sqmm cable including taking down shall be measured as one unit.
Material and labour for replacement submain wiring with Six run of single core PVC insulated cable copper conductor multi standed of size 10.0 Sqmm FRLS drawn through existing concealed/surface conduit/PVC casing capping including all accessories and taking down old existing aluminium or copper old/defective submain wiring of any size complete as per site requirements all as specified and directed by Engr-in-charge. Note: Six run of 10 sqmm cable including taking down shall be measured as one unit. Note for Sl No. 28 to 32 :- (i) Cuttung/grooves/chiselling as applicable shall be measured and paid separately and the quoted rate by the tenderer is inclusive for making good concealed conduit wiring portions in all respects to match with the adjoining surfaces as applicable (ii) Damaged portions of PVC conduit shall be measured and paid separately under relevent item here-in-after
Material and labour for Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface complete on roof/wall using required necessarty Tools and plants all as per site requirements as specified and directed by Engineer-in-charge.
Supply and fixing for replacement Rigid non-metallic PVC conduit/casing capping of upto 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as per site conditions complete specified and directed by Engineer-in-charge.
Supply and fixing for replacement Rigid non-metallic PVC conduit/casing capping not less than 40 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc all as per site conditions complete specified and directed by Engineer-in-charge.
Material and labour for replacement PVC/Polycorbonate best quality junction boxes 40 mm size / Round plates 75 mm to 100 mm with suitable size screws - 02 Nos as per site requirements complete all as directed by Engineer-in-charge
Material and labour for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to 20 x 3mm copper earth strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40 mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 3 connected to earthing test point complete including testing on completion all as specified and as directed by Engineer-in-charge. Note - (i) The quoted rate is inclusive for taking down existing old GI wire 4 mm dia earthing complete all as ditrected by Engineer-in-charge. (ii) Copper strip 20 x 3 mm and GI Tubing 40 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor.
Material and Labour for earthing Complete with GI earth platee electrode 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 M deep below normal ground level and complete earth plate connected to GI wire 4 mm by brazing only earth strip protected with light grade GI Pipe 15 mm dia bore from earth plate electrode and upto in and including the earth test point including 20mm bore water pipe medium grade GI Tubing including GI Funnel,wire mesh. alternate 5 layers of charcoal & salt crystal and removal of the excavated soil and depositing at the place where directed,PCC Pit in PCC (1:3:6) type C1 using 20 mm graded stone aggregate , RCC (m) Cover 40 mm thick in RCC (1:2:4) type B 1 using 20 mm grade aggregate reinforced with 8 mm dia TMT bars @ 7.5 mm c/c both ways including RCC Pit Cover etc watering the earth pit to acheive earth resistance below 02 Ohm incl testing complete all as specified and directed by Engineer-in-Charge. Note :- GI wire 4 mm,GI Tubing 15 mm light grade upto 7.5 mtr deemed to be included in the rate quoted by the contractor.
Supply, fixing, drawn GI wire 4 mm in GI pipe 15 mm pipe complete all as specified and as directed by Engr - in -charge.
Supply and fix GI pipe light grade 15 mm dia including on walls, roof / laid on floors, ground etc with all fittings for GI Wire protection all as specified and as directed by Engr - in -charge.
Material and labour for taking down unserviceable of ceiling fan sweep upto 1400 mm with blades and down rods etc from ceiling by unscrewing the nut bolts ,opening the split pin and keeping in safe custody for repairing and re fixing the same after repairs complete all as specified and as directed by Engineer-in-charge.
Material and labour for servicing of ceiling fan sweep upto 1400 mm complete on the site after inspecting all dismantled parts, complete erviceing and cleaning , greasing and removing all deposited materials and replacing following old parts and components with new ones and reassembling the same complete for smooth functioning complete all as specified and as directed by Engineer-in-charge.:- (a) Capacitor 2.5 mfd.- 01 No (b) PVC Capacitor Bracket - 01 No (c) Split pins complete for ceiling fan - 01 set
Material and labour for rewinding of ceiling fan motor complete of sweep upto 1400 mm after cutting the old unserviceable / burnt windindg with super enamelled copper winding wire of suitable gauge with connected bushes / bearings etc as applicable complete varnishing new winding drying up carefully complete all as specified and as directed by Engineer-in-charge.
Material and labour for taking down unserviceable of exhaust fan upto 450 mm sweep heavy duty with blades complete from existing positions using necessary louvers as applicable etc by unscrewing the nut bolts and keeping in safe custody for repairing and re fixing the same after repairs complete all as specified and as directed by Engineer-in-charge.
Material and labour for dismantling of exhaust fan upto 450 mm sweep motor with louvers assembly for servicing after inspecting all dismantled parts for their serviceablity and cleaning , greasing and removing all deposited materials and replacing unserviceable parts and components with new ones and reassembling the same complete for smooth functioning by replacing the following spares:- (a) Capacitor 2.0 mfd.- 01 No. (b) PVC Capacitor Bracket - 01 No (c) Split pin for exhaust fan - 01 set
Material and labour for rewinding of metal exhaust fan motor complete of sweep upto 450 mm after cutting the old unserviceable / burnt windindg with super enamelled copper winding wire of suitable gauge with connected bushes / bearings as applicable complete varnishing new winding drying up carefully complete all as specified and as directed by Engineer-in-charge.
Supply and fixing for replacement LED ceiling mounted recessed full lit luminaire with glare free uniform illumination 36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm copper cable complete in all respects all a directed by Engineer-in-charge.MAKE:- Crompton Cat No.LCTLRNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing for replacement LED ceiling surface mounted full lit luminaire with glare free uniform illumination 36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95, Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq copper cable complete in all respects all a directed by Engineer-in-charge.MAKE:- Crompton Cat No.LCTLSNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing for for replacement outdoor type LED street light fitting 25 watts IP 66 toughened glass high power LEDs lumens not less than 110LPW 10 KV SPD including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton Cat No LSTS-25-CDL-M or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Supply and fixing for replacement wall mounted LED PC batten, 20 Watt, 4 feet, with energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, integrated electronic driver 20 W fitting prewired and complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton cat No.CCS-102-20-65-SL-DP-NWH or techno equ in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Material and labour for replacement LED batten compact industrial with LED polycarbonate T8 tube 20 Watt, 4 feet long, with inbuilt driver and metal heat sink efficacy of 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, with integral drivers, complete all as directed by Engineer-in-charge Make - Cat No DIJB12LT8-20 + LT8-20-865-2 of make crompton or techno commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
Material and labour for replacement LED polycarbonate T8 tube 20 Watt, 4 feet long, with inbuilt driver and metal heat sink efficacy of 100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH, 10%, power factor ≥ 0.95, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80, with integral drivers, complete all as directed by Engineer-in-charge Make - Crompton Cat No LT8-20-865-2 or techno commercially equivalent model in philips/Havells/Osram/ Wipro/Bajaj/Halonix as approved by GE.
RRK PROJECTS (BID ID -3129849)
Pacific Enterprises (BID ID -3128718)
Sahara Engineers (BID ID -3125862)
Vishwas Enterprises (BID ID -3126066)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .