Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹5.1 L
Closing Date
3 Nov 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
15 conditions · 4 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Advance Correction Slip No.1(Rly. Board letter No.2022/CE-I/CT/GCC-2022/Policy date 14.07.2022.) PLEASE ATTACHCOPY OF AUDITED BALANCE SHEET.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' which ever is less where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. Advance Correction Slip No.1(Rly. Board letter No.2022/CE-I/CT/GCC-2022/Policy date 14.07.2022.) PLEASE ATTACHCOPY OF ANNEXURE VI-B.(Proforma is available in document).
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar Nature of work - Wiring/ Re-wiring in buildings with associated electrical works like control gear and protection arrangements in residential buildings or service buildings. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical works. OR wiring/Rewiring, Lighting arrangement in building with associated electrical works.
12 conditions · 8 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The tenderer should visit the site before quoting the bid.
This works contract and shall be governed by "General conditions of contract-Apr-2022
Tenderer should read the technical document attached under document section and all the terms and conditions.
(1) Ujjain - Electrical work in connection with provision and augmentation of crowd holding areas with additional passenger amenities (Simhastha-2028).(2) Ratlam Division - Providing temporary holding area to regulate passengers at Naikheri and Mohanpura, providing toilets and urinals at 04 stations Naikheri, Pingleshwar, Ujjain, Mohanpura and providing water arrangement at Laxmibai Nagar (Simhastha-2028).(3) Chintaman Ganesh - Providing temporary holding area to regulate passengers with passenger amenities (Simhastha-2028).
EL-2026-27-17~WR
EL-2026-27-17
Open
Works - General
12 Months
Ratlam, Madhya Pradesh
₹0
₹5.1 L
12 Oct 2026
12 Oct 2026
20 Oct 2026
60 items across 1 schedule · ₹2,53,25,457.53 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of material & wiring of light point/ceiling rose point by 1.5mm² copper PVC cable casing-capping pipe/PVC pipe with earth wire without switch. | Numbers | 1780.00 | 130.05 | 2,31,489 |
| 2 | Supply of material & wiring of ceiling rose/ light point by 1.5mm² copper PVC cable casing-capping pipe/PVC pipe with earth wire. | Numbers | 570.00 | 279.57 | 1,59,354.9 |
| 3 | Supply & fixing of Switch board medium size as per specification. | Numbers | 250.00 | 127.14 | 31,785 |
| 4 | Supply & fixing of Switch board small size as per specification. | Numbers | 71.00 | 50.83 | 3,608.93 |
| 5 | Supply & fixing of 6Amp Cap. Plug socket 5Pin on existing board including connection. | Numbers | 410.00 | 54.4 | 22,304 |
| 6 | Supply & fixing of 6Amp Cap. Plug socket 5Pin on separate board with wiring by copper cable PVC 2.5mm² including connection. | Numbers | 122.00 | 249.12 | 30,392.64 |
| 7 | Supply & fixing of 6/16 Amps Cap. Power Plug socket 5Pin on Separate board with wiring by Copper cable PVC 2.5mm² including connection. | Numbers | 55.00 | 284.6 | 15,653 |
| 8 | Supply & fixing Double pole MCB On board including connection as per specification. | Numbers | 180.00 | 292.73 | 52,691.4 |
| 9 | Supply of materials & wiring of sub main by copper cable PVC 2x2.5mm² with earth wire in PVC casing-capping/PVC pipe including connection. | Metre | 3200.00 | 39.64 | 1,26,848 |
| 10 | Supply of materials & wiring of sub main by copper cable PVC 2x4mm² with earth wire in PVC casing-capping/PVC pipe including connection. | Metre | 1300.00 | 87.79 | 1,14,127 |
| 11 | Supply and laying PVC Truncking system 50X50mm for sub main wiring as per specification. | Metre | 2700.00 | 167.88 | 4,53,276 |
| 12 | Supply & Fixing of LED Tube Light fitting 18/20W including connection as per specification. | Numbers | 362.00 | 713.74 | 2,58,373.88 |
| 13 | Supply, replacement, fixing, testing, connecting and commissioning of Inverter LED batten with square profile and poly carbonate /Extruded Aluminimum channel. Lithium Ion battery with charging time 8 hours-10 hours and back up time up to 3 to 4 hours energy efficient luminaries complete with all accessories of capacity 20 watt, 4 feet length, LED lamps with suitable current control driver circuit ,suitable for surface/recessed mounting as per IS:10322. LED - Luminaries:-(1) A complete LED lighting unit consisting of a light - source and river together with parts of distribute light, to position and protect the light source, and to connect the light source to a branch circuit. The light source itself may be an LED array and LED module, or an LED lamp. (2):-Supplied LED luminaries shall confirm to IS:16101(2012) IS :16106(2012).Light Source(LED) in the Luminaries should be of make:- (1):-NICHIA/ CREE/OSRAM/ SEOUL/ PHILIPS/LUMILEDS /LEDNIUM. (2):-LEDs to IS:16105(2012).IS:16108(2012),IEC:62471.1.Input operating voltage :-105-295 V AC.2:-Normal Voltage- 220V AC.3.Driver type: constant current driver with short circuit protection(For tube light).4.Control of distribution:-Full cut off.5.Drive component :Industrial grade only .6.Efficiency of driver electronic:>= 85% (For tube light).7.Colour temperature:5000-6500K(For tube light).8.Colour rendering index(CRI):>75(For tube light).9.Ingress protection :IP-20.10.Lumen output: >=100 lumens/[email protected] drive current(For tube light).11.Power factor:->0.90(For tube light). 12.Total harmonics distortion(THD):- <20%(For tube light).13.Lamp cover :Acrylic cover which does not result in loss of lumens.14.Finishing:Power coated /Anodized.15.Secondry optics' carbonate reflector/ poly carbonate lens.16.Construction of housing: extruded aluminum/CRCA/Pressure die cast aluminum.17.Mounting :Suitable for surface mounting/recessed mounting.18.Certificate:Firm to submit LM80(In respect of LED used)& LM79(In respect of luminareused) test certificate from National/International accredited Laboratory and OEM certificate for compliance ofBIS/IEC.19.Warranty:Firm to submit warranty certificate for five year along with the supply. All fittings should be embossed/sticker with manufacturing date and warranty details at time of supply.20.Theweight of fixture should be standard for better heat resistance of LEDPCB. All fittings shall be fitted as surface mounting/recessed mounting with twisted twin flexible cord of minimum size 16/0.2 mm copper conductor as per relevant technical specification. Materialprameters must remain unchanged during entire warrantyperiod.20watt. | Numbers | 270.00 | 733.92 | 1,98,158.4 |
| 14 | Supply & Fixing of LED Tube 40W Light fitting including connection as per specification. | Numbers | 80.00 | 1,845.35 | 1,47,628 |
| 15 | Supply , erection , testing & commissioning of LED Flood/ High Bay, 250 Watt Luminaries as per specification. | Numbers | 24.00 | 14,652.62 | 3,51,662.88 |
| 16 | Supply , erection , testing & commissioning of LED Flood/ High Bay 120 Watt Luminaries as per specification. | Numbers | 400.00 | 11,118.17 | 44,47,268 |
| 17 | Supply & fixing of LED Area light 70W including connection as per specification. | Numbers | 20.00 | 4,841.51 | 96,830.2 |
| 18 | Supply & fixing of exhaust fan 380 mm sweep including connection as per specification. | Numbers | 34.00 | 1,461.55 | 49,692.7 |
| 19 | Supply & fixing of exhaust fan 300 mm sweep including connection as per specification. | Numbers | 175.00 | 1,440.07 | 2,52,012.25 |
| 20 | Supply , erection , testing & commissioning of Energy efficient Electric Ceiling Fan with capacitor type sweep 1200/1400mm white colour ,with electronic fan regulator double ball bearing ,canopies with down rods ,and other accessories ,suitable for operation on single phase 230 Volt 50Hz supply as per specification. | Numbers | 740.00 | 1,145.85 | 8,47,929 |
| 21 | Supply, fixing testing & commissioning of minimum 03 Feet long or as per site down rod for existing fan as per specification. | Numbers | 740.00 | 229.13 | 1,69,556.2 |
| 22 | Supply & fixing testing & commissioning of wall bracket oscillating fan size 380 mm including connection as per specification. | Numbers | 5.00 | 1,242.05 | 6,210.25 |
| 23 | Supply , erection , testing & commissioning of 5Mtr Octagonal pole with pit foundation ,single arm bracket including connection as per specification. | Numbers | 37.00 | 9,481.74 | 3,50,824.38 |
| 24 | Supply , erection , testing & commissioning of 5Mtr Octagonal pole with pit foundation ,Double arm bracket including connection as per specification. | Numbers | 31.00 | 10,661.66 | 3,30,511.46 |
| 25 | Supply and fixing of LED street light 70W including connection as per specification. | Numbers | 104.00 | 4,290.22 | 4,46,182.88 |
| 26 | Supply of Self drinking water cooler with (Non CFC refringent) energy efficient compressor, cooling capacity Ltrs/Hr.: 150, Type : Storage, Storage Capacity Ltrs.: 150, Rate of Max. energy consumption watt:1550 as per specification. | Numbers | 31.00 | 45,323.59 | 14,05,031.29 |
| 27 | Supply and fixing of Evaporative Jumbo Air Coolers (Desert Coolers), Floor Mounted as per specification | Numbers | 170.00 | 22,485 | 38,22,450 |
| 28 | Supply and fixing of On load manual change over 200A as per specification. | Numbers | 7.00 | 19,921.71 | 1,39,451.97 |
| 29 | Supply & fixing of Control panel 200A Complete with MCCB As per specification. | Numbers | 8.00 | 77,118.02 | 6,16,944.16 |
| 30 | Supply and fixing of Control panel 100Amp with MCCB& MCB's etc. as per specification. | Numbers | 11.00 | 14,952.63 | 1,64,478.93 |
| 31 | Supply & fixing of Distribution box 63A complete as per specification. | Numbers | 22.00 | 10,921.55 | 2,40,274.1 |
| 32 | Supply of material , erection, testing & commissioning of Copper plate earthing arrangement as per specification. | Numbers | 12.00 | 8,887.81 | 1,06,653.72 |
| 33 | Supply and laying of GI Strip 25mm x 6mm for earthing as per specification. | Metre | 515.00 | 32.28 | 16,624.2 |
| 34 | Supply of material , erection, testing & commissioning of GI pipe earthing arrangement as per specification. | Numbers | 14.00 | 2,082.91 | 29,160.74 |
| 35 | Supply and fixing Perforated GI cable Tray 100x50mm as per specification. | Metre | 1350.00 | 387.73 | 5,23,435.5 |
| 36 | Supply , erection , testing & commissioning of ON Line UPS 2 KVA with isolation transformer suitable for single phase AC input and single phase output ,floor mounted type Back up time -120 minutes as per specification. | Numbers | 40.00 | 71,176.35 | 28,47,054 |
| 37 | Hiring of DG sets along with operator and all other accessories and equipment i.e. Changeover, Temporary Panel etc. for operation of DG set on rental basis. DG set should be manned round the clock so as ensure real time operation of the DG set (Diesel will be supplied by railway). The work also includes Provision of 04 Nos. Fire Buckets, 02 Nos. Fire Extinguishers near the control panel. Drawing of control panel should be duly approved by SrDEE/P/RTM or his nominee). All items on rental basis. 125 KVA DG Set:- 01 nos. for 60 days. (1 job = 1 generator per day.) as per specification. | Job | 300.00 | 4,435.6 | 13,30,680 |
| 38 | Supply of material, erection, testing & commissioning of Battery charging boxes (EFT) complete as per specification. | Numbers | 24.00 | 3,412.21 | 81,893.04 |
| 39 | Supply of material , erection , testing & commissioning of battery charger complete 200 Amp. as per specification. | Numbers | 1.00 | 1,59,112.89 | 1,59,112.89 |
| 40 | Supply erection ,testing & commissioning of AC coach Charging & pre cooling facilities as per specification. | Numbers | 16.00 | 15,468.45 | 2,47,495.2 |
| 41 | Design Supply, fixing and commissioning of the LED based pit/inspection light fitting 18watt, input voltage 48 V AC, Size of light fitting &fixture should be installation and fixing & grouting work should be done as per site requirement as per specification. | Numbers | 96.00 | 3,146.24 | 3,02,039.04 |
| 42 | Supply, Installation, Testing and Commissioning of step down transformer 1 Ph. 5KVA 240 Volts AC and out put 48 VAC with Volt meter and Ammeter complete with Enclosure suitable for pit/inspection light and catwalk light including connection etc. as per site requirement as per specification. | Numbers | 2.00 | 15,000 | 30,000 |
| 43 | Supply of material with fabrication and erection of MS Channel 100X50X6 mm with hardwares as per specification. | Metre | 220.00 | 259.81 | 57,158.2 |
| 44 | Supply of material , erection, testing & commissioning of cable junction box with bus bar as per specification. | Numbers | 96.00 | 2,032.27 | 1,95,097.92 |
| 45 | Supply of material , erection, testing & commissioning of cable junction box with 5 cut out /MCB as per specification.. | Numbers | 96.00 | 1,078.96 | 1,03,580.16 |
| 46 | Supply of material , erection, testing & commissioning of cable junction box with 2 cut out/ MCB as per specification.. | Numbers | 96.00 | 732.42 | 70,312.32 |
| 47 | SUPPLY AND LAYING 3 CORE, 2.5 SQMM, FLEXIBLE PVC INSULATED MULTICORE FRLS PVC SHEATHED MULTISTRANDED CABLES COPPER CONDUCTOR FOR VOLTAGE GRADE UPTO 1100 V CONFORMING TO IS-694:2010. | Metre | 5000.00 | 107.93 | 5,39,650 |
| 48 | SUPPLY AND LAYING 3 CORE, 4 SQMM, FLEXIBLE PVC INSULATED MULTICORE FRLS PVC SHEATHED MULTISTRANDED CABLES COPPER CONDUCTOR FOR VOLTAGE GRADE UPTO 1100 V CONFORMING TO IS-694:2010. | Metre | 3000.00 | 170.89 | 5,12,670 |
| 49 | SUPPLY AND LAYING 3 CORE, 6 SQMM, FLEXIBLE PVC INSULATED MULTICORE FRLS PVC SHEATHED MULTISTRANDED CABLES COPPER CONDUCTOR FOR VOLTAGE GRADE UPTO 1100 V CONFORMING TO IS-694:2010. | Metre | 1100.00 | 258.63 | 2,84,493 |
| 50 | SUPPLY AND LAYING 4 CORE, 10 SQMM, FLEXIBLE PVC INSULATED MULTICORE FRLS PVC SHEATHED MULTISTRANDED CABLES COPPER CONDUCTOR FOR VOLTAGE GRADE UPTO 1100 V CONFORMING TO IS-694:2010. | Metre | 1200.00 | 526.66 | 6,31,992 |
| 51 | Laying of 4core 240sqmm UGAC with heat resisting insulation PVC Insulated and strip type Sheathed Armoured Aluminium Conductor cable with 1x8SWG GI wire in existing trench/Pipe/ in air | Metre | 500.00 | 19.66 | 9,830 |
| 52 | Laying of 4core 185sqmm UGAC with heat resisting insulation PVC Insulated and strip type Sheathed Armoured Aluminium Conductor cable with 1x8 SWG GI wire in existing trench/Pipe/ in air | Metre | 500.00 | 19.66 | 9,830 |
| 53 | Laying of 4core 120sqmm UGAC with heat resisting insulation PVC Insulated and strip type Sheathed Armoured Aluminium Conductor cable with 1x8SWG GI wire in existing trench/Pipe/ in air | Metre | 2500.00 | 19.36 | 48,400 |
| 54 | Laying of 4core 70sqmm UGAC with heat resisting insulation PVC Insulated and strip type Sheathed Armoured Aluminium Conductor cable with 1x8SWG GI wire in existing trench/Pipe/ in air. | Metre | 4500.00 | 19.27 | 86,715 |
| 55 | Laying of four Core 25sqmm UGAC with heat resisting insulation PVC Insulated and strip type Sheathed Armoured Aluminium Conductor cable with 1x8SWG GI wire in existing trench/Pipe/ in air | Metre | 6000.00 | 19.33 | 1,15,980 |
| 56 | Supply and laying of double walled corrugated HDPE Pipes of size 120mm Outer dia &103mm inner dia as per specification. | Numbers | 40.00 | 1,400.07 | 56,002.8 |
| 57 | Supply and laying of 63 mm dia. DWC pipe complete as per specification. | Metre | 2400.00 | 52.43 | 1,25,832 |
| 58 | Digging of trench | Metre | 4000.00 | 109.86 | 4,39,440 |
| 59 | Digging of Pacci trench | Metre | 1100.00 | 279.64 | 3,07,604 |
| 60 | Providing 100mm dia. GI/MS Pipe under track by pushing method as per specification. | Metre | 300.00 | 1,579.07 | 4,73,721 |
| Schedule total | ₹2,53,25,457.53 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
1.Letterofcreditasmodeofpayment04-06-2018.pdf
ATTACHMENT
2.ProcedureforpaymentofContractorbillasperGSTImplementation_GST_290617.pdf
ATTACHMENT
3.PBGproforma.pdf
ATTACHMENT
4.NOrelativecertificate.pdf
ATTACHMENT
5.certificateforrailwayemployeere-engagement_11.pdf
ATTACHMENT
6.BidsecurityAnnexure-VIA.pdf
ATTACHMENT
7.FormatVA.pdf
ATTACHMENT
8.FormatforAnnualcontractualturnoverAnnexure-VIB1.pdf
ATTACHMENT
9.GCCAPRIL-2022.pdf
ATTACHMENT
10.GCCACS-1dt.14-07-2022.pdf
ATTACHMENT
11.GCCACS-2dt.13-12-2022.pdf
ATTACHMENT
12.GCCACS-3dt.26-04-2023.pdf
ATTACHMENT
13.GCCACS-4dt.07-08-2023.pdf
ATTACHMENT
14.GCCACS-5dt.20-10-2023.pdf
ATTACHMENT
15.GCCACS-6dt.21-12-2023.pdf
ATTACHMENT
16.GCCACS-7dt.25-09-2024.pdf
ATTACHMENT
17.GCCACS-8dt.20-12-2024.pdf
ATTACHMENT
18.GCCACS-9dt.09-01-2025.pdf
ATTACHMENT
19.GCCACS-10dt.27-03-2025.pdf
ATTACHMENT
20.ClarificationannexureV.pdf
ATTACHMENT
21.TERMINATIONCONTRACT.pdf
ATTACHMENT
TS830-Technicaldocumentcrowdholdingarea-_1.pdf
ATTACHMENT
20.GCCACS-11dt.13-03-2026_compressed.pdf
ATTACHMENT
WRProcurementofLEDlightfittingsSpecification.pdf
ATTACHMENT
2025-10-29ModelspecificationofLTpanelfor415Vpowersupplysystem.pdf
ATTACHMENT
2026-08-25TechnicalcircularforEarthing.pdf
ATTACHMENT
circular for Hmast earthing
ATTACHMENT
2026-07-12TechnicalcircularforearthingarrangementandmainteancescheduleforHighmast.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .