Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.5 LAccepted-AOC | ₹2.5 L Quoted ₹20.5 L | L-1 | Accepted-AOC L-1 bidder, offered rate is reasonable and acceptable |
| 2 | Rejected-Technical 1BR COLONY POST BACHRA P S PIPARWAR DISTT CHATRA JHARKHAND | CHATRA | JHARKHAND | 825103 | - | - | Rejected-Technical L-2 bidder, document of L-2 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially |
| 3 | Rejected-Technical 0 56 5 NATESHPURAM KANKAR KHERA MEERUT MEERUT UTTAR PRADESH 250001 | MEERUT | UTTAR PRADESH | 250001 | - | - | Rejected-Technical L-3 bidder, document of L-3 bidder not scrutinised as bid of L-1 bidder found accetable technically and financially |
Tender Value
₹2.7 L
EMD Value
₹3,400
Closing Date
26 Mar 2024, 5:00 pmClosed
Staff Officer(EnM)
Office of the GM, Piparwar Area, Post Bachra, Dist Chatra, Jharkhand
Fresh Wiring of VTC (Vocational Training Centre) situated at Ray-Bachra UG under Bachra Project , Piparwar Area.
2024_CCL_305353_1
SO(EnM)/PPR/eNIT/23-24/109
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
Bachra Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,400
17 Jun 2024
16 Mar 2024
27 Mar 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
16 Mar 2024 - 22 Mar 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole & neutral
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amp
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4+12) Double door
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing 2 x 2.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 16 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Providing and laying in position cement concrete of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone)
Supply and fixing of brass batten / angle holder
Supply & fixing of 70 W LED street light
Supply & fixing of Wall Fan 400 mm
Supply & fixing of 22 W LED tube light
Total impact of GST for the purpose of CTC
M/S SHAILESH KUMAR SINGH
M/s.Pooja Construction
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .