| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹78.9 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹84.5 L+₹5.5 L (6.99%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹86.2 L+₹7.2 L (9.16%)Rejected-Finance 59 49 A BIRHANA ROAD KANPUR KANPUR NAGAR UTTAR PRADESH 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹88.8 L+₹9.9 L (12.5%)Rejected-Finance 303 MAHESH NANGIA 303 PRAGATI CHAMBERS RANJIT NAGAR COMMERCAIL COMPLEX RANJIT NAGAR COMMERCIAL COMPLEX | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹89.3 L+₹10.4 L (13.2%)Rejected-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-5 | Rejected-Finance L-5 |
Tender Value
₹99.9 L
EMD Value
₹2.0 L
Closing Date
16 Dec 2019, 6:00 pmClosed
AGM Electrical
Room No. F-11. Ist Floor, Engineering office, Residential Colony, AAI, Jaipur Airport, Jaipur-302029
Construction of parallel taxiway track from existing Nallah to beginning of runway 27 (Phase-II) at Jaipur International Airport, Jaipur. SH Diversion/Shifting of electrical cables.
2019_AAI_36945_1
AAI/JPR/ENGG(E)/M-02/2019-20
Open Tender
Electrical Works
Item Rate
180 days
Jaipur
Please refer Tender documents.
15 documents required · 15 mandatory
₹1,120
AAI REVENUE COLLECTION A/C NO. 708300300980020
₹2.0 L
6 Feb 2020
2 Dec 2019
20 Dec 2019
2 Dec 2019
16 Dec 2019
2 Dec 2019
2 Dec 2019 - 6 Dec 2019
Amount
Supply of 3.5 x 300 sqmm size 1.1 KV grade XLPE insulated PVC sheathed armoured aluminium conductor power cable confirming to IS 7098 (part-1) 1988 amended upto date complete as required.
Supply of 3.5 x 185 sqmm size 1.1 KV grade XLPE insulated PVC sheathed armoured aluminium conductor power cable confirming to IS 7098 (part-1) 1988 amended upto date complete as required.
Supply of 3.5 x 150 sqmm size 1.1 KV grade XLPE insulated PVC sheathed armoured aluminium conductor power cable confirming to IS 7098 (part-1) 1988 amended upto date complete as required.
Supply of HDPE pipe of PN-6, PE-63 grade conforming to IS 4984 (1995) amendant upto date, 6Kg/cmsq pressure rating including sockets accessories etc. of size 200 mm outer dia complete in all respect as required.
Dismantleing of existing cable of size 3.5 x 300 sqmm for reuse laid temporarly in the DWC pipe at the depth of 30 cm in the ground including depositing the cable in the AAI store/ at new site complete in all respect as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 95 sq. mm and upto 185 sq. mm direct in ground including excavation, protective covering but excluding sand cushioning and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm direct in ground including excavation, protective covering but excluding sand cushioning and refilling the trench etc as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 95 sq. mm and upto 185 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size Above 185 sq. mm and upto 400 sq. mm in the existing RCC/ HUME/ METAL pipe as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm size in the existing masonry open duct as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 185 sq. mm and upto 400 sq. mm size in the existing masonry open duct as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) size on wall surface as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) size on wall surface as required.
Mechanized laying (through HDD) of existing 200 mm HDPE pipe underneath the Runway/Taxi way/Road etc. complete in all respect as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 150 sq. mm (50mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 185 sq. mm (50mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making end termination with brass compression gland and aluminium lugs for 3.5 X 300 sq. mm (50mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 X 150 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 X 185 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 3.5 X 300 sq. mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supplying, Installation, Testing and Commissioning of double door type cable junction box made out of 2mm thick of size 750mm X 750mm X 400 mm suitable for 415V, 3 phase 4 wire 50Hz AC supply system fabricated from CRCA sheet stell of 3mm thick for gland plates having 4 nos of allumimium alloy busbar of size 500mm X 40mm X 10mm of high conductivity with bus bar supports, nut bolts, two nos of holes at the bottom of suitable size for the cable entry of 3.5 X 300 sqmm size, M.S. Stand of 750mm length including concrete foundation grouting of stand etc. complete in all respect as required.
Supply and fixing of circular precast RCC manhole of size 50mm thick 900mm inner dia. and 825 mm depth including 50 mm thick RCC top cover of 1000 mm dia. Including making the circular 10 cm thick base foundation of position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) complete in all respect as required.
Providing Xylo/Innova/Tavera bearing Commercial registration number on hire basis for Movement of Executives/officials for office work i/c Diesel, Driver and maintenance all complete.The Maximum running shall be restricted to 2500 km per month complete as per direction & satisfaction of Engineer-in-Charge. Vehicle is required during the execution of the work.
TANNA ELECTRIC COMPANY
Choubay And Co.(Agencies) Pvt.Ltd.
HITECH ERECTORS PVT. LTD.
Manish Electricals
Metropolitan Infrabuild Development And Services Pvt Ltd
UTSAV INDIA LIMITED
S S Engineers
Yash Energy Pvt. Ltd
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .