Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹31.5 L+₹2.1 L (7.06%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹31.8 L+₹2.4 L (8.28%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L3 | Rejected-AOC Not being L1 | |
| 4 | L4₹32.6 L+₹3.2 L (10.8%)Rejected-AOC | L4 | Rejected-AOC Not being L1 | |
| 5 | L5₹33.8 L+₹4.4 L (15.0%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-AOC Not being L1 |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GARRISON ENGINEER UTILITY SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPL REPAIRS OF LT OVERHEAD SYSTEM TO UNDERGROUND CABLES SYSTEM AT KOWKOOR MD ACCN AND AMMUGUDA 96 OR MD ACCN UNDER AGE E/M NO 1 OF GE (U) SECUNDERABAD
2021_MES_466916_1
GE(U)/SEC/TOKEN/33 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Secunderabad
AS PER NIT
8 documents required · 8 mandatory
₹500
GE Utility Secunderabad
₹74,000
Yes
1 Sept 2022
10 Aug 2021
2 Sept 2021
10 Aug 2021
31 Aug 2021
25 Aug 2021
Amount
Dismantling poles/struts any size
Dismantling of insulators any type
Dismantling of ACSR conductor
Dismantling cross-arms of M.S. channel or angle sections etc. complete
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of following sizes
LT UG Cable 4 core, 16 Sqmm
LT UG Cable 4 core, 25 Sqmm
LT UG Cable 3.5 core, 70 Sqmm
LT UG Cable 3.5 core, 120 Sqmm
LT UG Cable 3.5 core, 185 Sqmm
Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC complete all as specified and directed including taking down old pole. Note: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in hard / dense soil complete all as specified and directed.
All as per item No 7 here in before but depth exc 1.5 m & below 3 m
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L filling approved river sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down shall be measured for payment.
Supply and Lay un-reinforced precast concrete cable covers, class LV, type-I, flat of size 250mm x 150mm x 40mm laid across in trenches for cable protection as in repairs complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregates as in foundation, filling and mass concrete for pole / stay / post including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4 type C1 using 20mm graded stone aggregate in coping of poles / foundation for poles, struts, posts etc including necessary form work, finished the exposed surfaces fair and even without using extra cement complete all as specified and directed.
S&F cable route indicator for LT UG cable of 1100 volts bolted with 40x6 mm flat iron member of height 0.60 mtrs and 80 mm CI plate embeded in PCC 1:3:6 type C2 of size 20x20x30 cm block complete all as specified
Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation and PCC foundation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-
INCOMING (a) Bus bar chamber with electrolytic aluminium bus bar suitable for 400 amps capacity for 3 phase and neutral 200 amps (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves - Set -1 (b) MCCB 4 pole adjustable thermal and fixed magnetic setting type , 320 Amp, 415 Volts 35 KA – 01 No
Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation and PCC foundation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-
INCOMING (a) Bus bar chamber with electrolytic aluminium bus bar suitable for 200 amps capacity for 3 phase and neutral amps (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves - Set -1 (b) MCCB 4 pole adjustable thermal and fixed magnetic setting type , 160 Amp, 415 Volts 35 KA – 01 No
Supply, installing, testing and commissioning, factory made and tested, CPRI approved LT panel board outdoor type, weather, vermin proof, cubical type, platform mounted, suitable for 415 volts, 3 phase 4 wire 50 Hz AC supply system all as specified and directed, with necessary insulated bus bar arrangement of 4 strips, the panel should be dust proof, IP 54 class protection and made out of 3.15mm thick CRCA mild steel sheet with 50x50x6mm angle iron frame with necessary earth work excavation and PCC foundation, hinged doors, front and rear opening and locking arrangement and duly powder coated on the out side and inside, cable glands and lugs for incoming and out going cable etc, independent chamber to accommodate complete all as specified and directed including following accessories :-
INCOMING (a) Bus bar chamber with electrolytic aluminium bus bar suitable for 200 amps capacity for 3 phase and neutral amps (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrieked insulating sleeves - Set -1 (b) MCCB 4 pole adjustable thermal and fixed magnetic setting type , 125 Amp, 415 Volts 25 KA – 01 No
S&F Weather proof outdoor bus bar chamber made out of 3mm thick MS sheet comprising 4 Nos aluminium strips each of 200Amps, 90cm long duly insulated mounted on insulators including 100 Amps MCCB with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 60cm (30cm depth below ground level and 30cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers, cable glands at entry and outlet points and excavation, earth work, returning filling in and removal of surplus soils complete all as specified and directed.
M & L earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron strip 25 x 4 mm, by means of nuts, bolts, check nuts and washer etc of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth elelctrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agagregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- The cost of 7.5m long galvanised iron earth strip 25 x 4 mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate.
M&L cutting of road/hard standing upto a size not exceeding 20 cm in width and not exceeding 60 cm in depth for laying of LT UG cable/protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/cement mortar in CM (1:2) complete all as specified and directed
Supply & lay Galvanised Iron tubing 40mm bore, light grade in protection of cable at road crossing/hard standing/pole protection fixed with MS clamps of size 25 X 4 mm, nut bolts and washer as per site requirementcomplete all as specified and directed.
All as per item No 22 above but GI tubing 80 mm bore.
Supply and fix junction box thermoplastic body for street light pole with locking arrangement with IP -66 protection, size 205 x 255x112 with 32 Amp 4 way heavy duty terminal block with 10 Amp MCB SP along with suitable cable glands and two steel bracket to fix with pole complete. Make :- Hensel Cat part no KF2525G or equivalent as approved by Engr-in-charge
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor 3 core 1.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings.
Srinivasa Consructions
L and S ENTERPRISES
vvcenterprises
STANDARD AGENCIES
POWER CONSTRUCTION COMPANY
omsai thermax engineers
Sri venkateswara Electricals
sree venkateswara enterprises
sandhya enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .