Loading…
Loading…
Tender ID
Tender Value
₹14.7 L
EMD Value
₹14,700
Closing Date
27 Feb 2026, 3:00 pmClosed
COMMISSIONER, TIRUNELVELI CORPORATION
1 Sn High Road Tirunelveli Municipal Corporation
Construction of Smart Bus Shelter (Size 6.00m x 2.50m) at Kakkan Nagar New Colony in ward No. 5
2026_MAWS_663443_12
58/2025-26
Open Tender
Civil Works
Works
90 days
1 Sn High Road Tirunelveli Municipal Corporation
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹14,700
21 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
27 Feb 2026
21 Feb 2026
Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrock requiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete 10 cum
Supplying and filling in foundation and basement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted etc., complete complying with standard specification.
Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification
Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X 60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of Crushed Stone Sand (M- Sand), but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specifications.
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification.
Supplying and filling the basement with Good Earth filling in layers of not more than 15cm thick well rammed watered and compacted - etc., complete complying with standard specification.
Plastering with cement mortar (1:5) 12mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306)
Eurocon flooring with one course or pressed tiles of size 30cm x 30cm x 18mm laid in cm 1:3mix mixed with crude oil 10% by weight of cement and pointed with same oiled mortor in all cost of materials and labour charges etc complete
Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed.
Supplying and fixing of Bus shelter of size 6.00M x 2.50 M with 3.0 Nos of vertical supports ( 2.70 m height ) made out of stainless steel pipes of grade 316 and dia 219mm (OD) with suitable trusses, SS roofing Sheet of 2mm thick and stiffening plates with seating arrangements etc.,
Providing illumination boards back light adversiting panel and side board for displaying Bus Route Numbers and lighting arrangements to the Bus shelters (Size - 5m x 1.2m)
Supply, fixing and commissioning of passenger information display 4ft x 2 ft Bus Station display (Pitch-P10), Automative Quality, Amber Color with 3G/4G Modem for remote messaging with installation charges
Supplying and fixing Rectro reflecting sign board including S.S.Frame work of size (6m x 0.4m) including all cost and conveyance of materials and all labour charges etc., complete.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (PWD SOR 2020-2021 P.No 61, SI.No 225)
Wiring with 2x1.5sqmm PVC unsheated SC.alu.cable of 1100V grade with sutable PVC riged pipe Concealed on wall and ceiling with accessories and in flush with wall with 150mm X 100mm x113mm TW switch box and 5A F.T Switch in flush withwall 3mm thick hylum sheet cover for making good of the Concealed portion with painting of sutable colour and continues earthwire connection of 14 SWG TC wire for Concealed PVC Plug Point (SD 38)
Supply and fixing of TNEB meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32 Aneutrallink and earth link (1"x1/8"copperflat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thicka neither side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit (SD 125)
Supply and Run off 2 x 4 Sqmm 56/0.3 PVC insulated SC unsheathed cu.conductor of 1100V grade in rigid pipe conceled in wall and ceiling with continious earth wire connection of 14 SWGC TC wire and making good of the conceled portion with suitable colour (SD 56)
Supply and run of 2 of 4sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in 25mm dia GI pipe (Class'B') suitably bent at both ends with necessary angle iron upright and end supports for mains (SD 70)
Supply and fixing of 15 A aerial fuse unit (500A) on suitable 100x100mm TW concealed box with hylem sheet on on the tapping pole with necessary clamps SD 128
Street light Automatic 7 days 24 hours On/Off Programmable Digital Time switch control panel board with 40Amps contact
Supplying and fixing of single box type 4'40 w flu fitting complete with Electronic Ballast with TW round block on wall or ceiling with flutube PVC unsheathed Copper leads from terminal to the fitting (SD 87)
Supplying and fixing of Innaguration function of Tablet Stone and other items of expenditure with all cost and conveyence of material and labour cost at site etc., complete as per standard specification
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
BOQ_796805.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .