| Sl No | Description | Qty | Unit | Sri Birgrang Basumatary L1 | Raju Brahma L2 |
|---|---|---|---|---|---|
| 1.00 | A. Boundary Wall:
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge:
2.1.1 All kinds of soil | 105.87 | Cum | 107 ₹11,328.09 | 107 ₹11,328.09 |
| 2.00 | Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (cach layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer-in-charge, including compacting each layer by rolling/ramming and watering, all complete as per drawing and direction of Engineer -in - charge | 88.22 | Sqm | 253.95 ₹22,404.74 | 253.95 ₹22,404.74 |
| 3.00 | Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following
grades of concrete. All works upto plinth level 4.20A.1.1 Concrete of M10 grade with minimum cement content of 220 kg/cum. | 8.82 | Cum | 7,102.95 ₹62,669.33 | 7,102.95 ₹62,669.33 |
| 4.00 | STEEL REINFORCEMENT
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
5.22.1 Mild steel and Medium Tensile steel bars | 39.37 | Qntl | 8,998.45 ₹3.5 L | 8,998.45 ₹3.5 L |
| 5.00 | 5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. | 10.11 | Kg | 8,965 ₹90,672.01 | 8,965 ₹90,672.01 |
| 6.00 | Centering and shuttering including strutting, propping etc. and removal of form work for:
4.3.3 Columns, piers, abutments, pillars, posts and struts | 298.44 | Sqm | 804.25 ₹2.4 L | 804.25 ₹2.4 L |
| 7.00 | Centering and shuttering including strutting, propping etc. and removal of form work for:
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers | 190.77 | Sqm | 608.35 ₹1.2 L | 608.35 ₹1.2 L |
| 8.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:
5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: graded stone aggregate 20 mm nominal size de rived from natural sources) | 38.65 | Cum | 8,364.2 ₹3.2 L | 8,364.2 ₹3.2 L |
| 9.00 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : | 7.3 | Cum | 10,185.05 ₹74,330.49 | 10,185.05 ₹74,330.49 |
| 10.00 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand) | 31.79 | Cum | 6,882 ₹2.2 L | 6,882 ₹2.2 L |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
11 Jul 2025, 2:30 pmClosed
Director PNRD BTC Kokrajhar
Director PNRD BTC Kokrajhar
DPRD/BTC/15FC/VII/Baksa/1/2025/20
2025_BoTC_45161_1
DPRD/BTC/15FC/VII/Bak/1/25/20
Open Tender
Civil Works
90 days
Goreswar Baksa
Refer to Bid Document
4 documents required · 4 mandatory
₹480
₹48,000
Yes
15 May 2026
25 Jun 2025
11 Jul 2025
25 Jun 2025
11 Jul 2025
25 Jun 2025
25 Jun 2025 - 11 Jul 2025
Amount
A. Boundary Wall: Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge: 2.1.1 All kinds of soil
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (cach layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer-in-charge, including compacting each layer by rolling/ramming and watering, all complete as per drawing and direction of Engineer -in - charge
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level 4.20A.1.1 Concrete of M10 grade with minimum cement content of 220 kg/cum.
STEEL REINFORCEMENT 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. 5.22.1 Mild steel and Medium Tensile steel bars
5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.3 Columns, piers, abutments, pillars, posts and struts
Centering and shuttering including strutting, propping etc. and removal of form work for: 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.1 Cement mortar 1:3 (1 cement :3 coarse sand)
12 mm cement plaster of mix : 13.1.1 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 13.2.1 1:4 (1 cement: 4 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : 13.43.1 Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade : 13.44.1 New work (Two or more coats applied @ 3.84 kg/10 sqm)
B. Iron Gate Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 2.1.1 All kinds of soil
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (cach layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer-in-charge, including compacting each layer by rolling/ramming and watering, all complete as per drawing and direction of Engineer -in - charge
Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources and using recycled concrete aggregate (RCA) as coarse aggregate and fine aggregate within the permissible utilization, Portland Pozzolana /Ordinary Portland/Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level 4.20A.1.1 Concrete of M10 grade with minimum cement content of 220 kg/cum.
STEEL REINFORCEMENT 5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. B) other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg, drain retaining wall & boundary wall etc.
Centering and shuttering including strutting, propping etc. and removal of form work for: 4.3.3 Columns, piers, abutments, pillars, posts and struts
Centering and shuttering including strutting, propping etc. and removal of form work for: 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level: 5.1.2 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: graded stone aggregate 20 mm nominal size de rived from natural sources)
b) In Super Structure from plinth level up to 1st floor level. Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing rails for plying of rollers of gate made from 50mm x 6mm size M.S.flat and to be fitted with 3 nos. of hinged hold fasts to be embedded in concrete prop 1:2:4 of 10mm wide and 75mm deep over brick flat soiling 250mm wide including curing etc. complete.
Providing roller to the gate including welding etc. complete. a) With 25mm x 50mm (dia) roller
Raju Brahma (BID ID -271367)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
SBD_26.pdf
Tender Documents • 1.47 MB
BOQ_71505.xls
BOQ • 0.24 MB
FOB_26.pdf
Additional Documents • 0.17 MB
Download all tender documents and submit your bid