Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹1.3 LAccepted-AOC AT BACHRA DST CHATRA JHARKHNAD 829201 | CHATRA | JHARKHAND | 829201 | L-1 | Accepted-AOC Work awarded to L1 Bidder. | |
| 2 | Rejected-Technical AT KASIYADIH CHATRA JH | - | Rejected-Technical L4 Bidder. Documents of L4 Bidder not scrutinized as bid of L1 Bidder found acceptable technically and financially. | |
| 3 | Rejected-Technical RAY RANCHI | RANCHI | JHARKHAND | 829205 | - | Rejected-Technical L3 Bidder. Documents of L3 Bidder not scrutinized as bid of L1 Bidder found acceptable technically and financially. | |
| 4 | Rejected-Technical 00 HANSH NAGAR RADHA RAMAN ROAD MAINPURI MAINPURI UTTAR PRADESH 205001 | MAINPURI | UTTAR PRADESH | 205001 | - | Rejected-Technical L2 Bidder. Documents of L2 Bidder not scrutinized as bid of L1 Bidder found acceptable technically and financially. |
Tender Value
₹1.5 L
EMD Value
₹1,900
Closing Date
18 Sept 2023, 5:00 pmClosed
Staff Officer(EnM)
Office of the GM, Piparwar Area, Post Bachra, Dist Chatra, Jharkhand
Fresh wiring / repairing of Community place at Bazar tand and Qtr. No.C-01 and C-02 at Shanti Vihar Colony of Bachra Township under GM unit, Piparwar Area.
2023_CCL_288206_1
SO(EnM)/PPR/eNIT/23-24/51
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Bachra Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,900
24 Dec 2023
7 Sept 2023
19 Sept 2023
7 Sept 2023
18 Sept 2023
7 Sept 2023
7 Sept 2023 - 13 Sept 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 Amp
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and drawing 2 x 2.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
Supplying and drawing 2 x 1.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
Providing and laying in position cement concrete of ratio 1:3:6 (1 cement : 3 coarse sand : 6 graded stone)
Supply and fixing of 2+4 way , SPN double door MCB DB
Supply and fixin gof brass batten / angle holder
Supply and fixing of 22W LED tube light
Supply and fixing of 50W LED Street Light
Total impact of GST for the purpose of CTC
M/S S.K. ENTERPRISES
M/S R.S.VISHAVKARMA WORKS
M/S ARJUN ENTERPRISES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .