Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29 LAccepted-AOC PO PS BOMDILA DISTT WEST KAMENG ARUNACHAL PRADESH 790001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L1 | Accepted-AOC AOC due to L1 bidder | |
| 2 | L2₹34.5 L+₹5.1 L (17.3%)Rejected-Finance | L2 | Rejected-Finance HIGH BID VALUE | |
| 3 | L3₹40.0 L+₹10.6 L (36.1%)Rejected-Finance | L3 | Rejected-Finance HIGH BID VALUE | |
| 4 | L4₹41.1 L+₹11.7 L (39.8%)Rejected-Finance | L4 | Rejected-Finance HIGH BID VALUE | |
| 5 | L5₹41.8 L+₹12.5 L (42.4%)Rejected-Finance NA | L5 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
11 Nov 2023, 5:00 pmClosed
LT COL BIRENDRA SINGH
GE 859 EWS
SPECIAL REPAIR/REPLACEMENT OF LT SUPPLY SYSTEM CONTROL PANELS REPLACEMENT OF OLD U/S SECURITY LIGHT POLES WITH ENERGY EFFICIENT LED SECURITY LIGHTS CONTROL CABLES AND SPECIAL REPAIR/REPLACEMENT OF UG CABLE EARTHING AND CONNECTED ITEMS WITH CONNECTED
2023_MES_624446_1
8464/E8
Open Tender
Civil Works
Item Rate
180 days
BAIISAKHI
PL REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
₹56,000
19 Apr 2024
21 Oct 2023
13 Nov 2023
21 Oct 2023
11 Nov 2023
4 Nov 2023
Amount
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar , outdoor type floor mounted , suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 400 Amps each ,fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos. Incoming:- (b) MCCB, 04 Pole, 250 Amps with ultimate breaking capacity Icu- 50 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%). Outgoing:- (c) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) (d) MCCB, 04 Pole, 125 Amps with ultimate breaking capacity Icu- 16 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 No (Ics=Icu=100%) ,
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 95 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.
Description all as per item No 2 above but of size 70 sqmm 3.5 core
Description all as per item No 2 above but of size 16 Sqmm 4 core
Description all as per item No 2 above but of size 16 Sqmm 2 core
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supplying and laying un-reinforced precast concerete cable cover, class LV, type 1 flat size 250mm x150mm x 40mm for cable protection , laid flat ie length of cable cover shall be laid across the cable, complete casted with PCC 1:2:4 Type B1 using 20mm graded crushed stone aggregateall as specified and directed
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
Supply and laying galvanised tube light grade ISI marked of size 50 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
S&F in replacement Kit Kat TPN 415 volt 3 Phase with HRC fuses suitable for interior mounting fixed on Wooden boards/PVC boards of capacity 63 Amp .
M&L for replacement of new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 45 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including taking down of old unserviceable street light any type/any capacity including replacement of twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from junction box to LED light throgh copper connectos all as specified and directed. Make: Havells/Bajaj/Philips
S & F in replacement of GI brackets for fixing LED street light fitting fabricated out of GI tubing 40 mm dia, medium grade, 1.2 mtr long , bend to 120 degree shape by cutting, welding and well finishing including MS clamp of flat iron of size 32 x 4 mm -02 Nos complete for steel poles / PCC pole as per site requirement with nut, bolt & washers for fixing of GI bracket complete all as specified and directed.
S&F in replacement of PVC insulated copper cable 2.5 Sqmm 3 core from junction box to security light all as specified & directed.
S&F in replacement kiosk box for luminaires ,weather proof made out of HDPE/FRP housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole mounting type comprising of four pole copper connectors of 16 Amps capacitywith 6 Amp MCB single pole , of minimum size 250x200x100mm, IP 66 fixed on pole with MS, clamps 30 x 5mm with necessary nuts, washer and incl applying two coats of synthetic enamel paint over a red oxide primer on steel surface/clamps and embossing/painting of Danger sign of size not less than 10cms x 7.5cms with letter and conventional skull and bones in single red color on front face of kiosk box complete all as directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
S&F & testing commissioning of outdoor type bus bar panel pedestal type weather proof CPRI approved MS cubical panel board outdoor type of size 110 cm x 40 cm x 80 cm, 4 Nos of bus bar of 300 Amp capacity & MCCB 250 Amp capacity 4 pole (Ics = Icu = 100%) including one coat of red oxide and two coat of enamel paint powder coated, mounted on channels and PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels aluminium busbar chanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. The panel shall be fixed over Angle iron frame (50 x 50 mm) of minimum height 75 cm Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel
M/s 99 Enterprise of India
M/S K D CONSTRUCTION
M/S KHANDU CONSTRUCTION
PARBIN SIDDIKI
SHELLUNG CONSTRUCTION
M/S T D Enterprises
TENZIN CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .