Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.7 LAccepted-AOC NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹65.2 L+₹3.1 L (4.98%)Rejected-Finance 245A 7A 1 JAYANTIPUR GOKUL AVAS YOJANA SULEM SARAI ALLAHABAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211011 | L2 | Rejected-Finance Other than lowest quoted tenderer | |
| 3 | Rejected-Technical HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | - | Rejected-Technical Rejected due to two class below as per NIT |
Tender Value
₹66.0 L
EMD Value
₹1.2 L
Closing Date
4 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Prayagraj
HQ CWE New Cantt Prayagraj
PREVENTIVE SERVICING AND MAINT OF HT 33 KV HT INSTALLATION AND DISTRIBUTION NETWORK AT OLD CANTT AND FORT CANTT UNDER GE (E) PRAYAGRAJ.
2024_MES_661671_1
81891/E/E8
Open Tender
Civil Works
Item Rate
180 days
Prayagraj
Class C and Category b(iii)
6 documents required · 6 mandatory
₹1,000
GE (East) Prayagraj
₹1.2 L
Yes
12 Nov 2024
24 Jun 2024
11 Sept 2024
25 Jun 2024
4 Sept 2024
16 Jul 2024
Amount
Excavation in trenches/pits in any type of soft soil not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out complete all as specified and directed.
Returning, filling in with the earth obtained from item No.01 here-in-before including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class HVP, type 1, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for clean and dry sand (unwashed) in trenches around the cable for cushioning complete all as specified & directed. Note :- Sand cushioning 8cm before laying the cable and 15cm after laying the cable & punned down 18cm,and punned thickness shall be measured and paid complete all as specified and directed.
Supply, laying, testing and commissioning in pipes/ ducts/poles/ trenches/ under floor/ under road XLPE insulated cable screened PVC heavy duty with aluminium conductor,11000 Volt grade (earthed) of cross section area 95 Sqmm,3 core complete all as specified & directed.
Supply and laying 80mm bore GI pipe 'light grade' in trenches,under floors,roads,along poles for protection of cables,including sealing ends complete all as specified & directed. (MS Clamps to be measured and paid under appropriate item)
Routine testing of 33 KV assets authorised representative of manufacturer to be tested are as under:- (b) Transformer 33/11 KV, 1.6 MVA - 03 Nos. (A) Tests to be carried out :- (i) IR Value test of both transformer and bushings. (ii) Testing of tap changer. (iii) Dielectric strength of transformer oil. (iv) Earthing test
Routine testing of 33 KV SF 6 Breaker (03 Nos) by authorised representative of manufacturer to be tested are as under:- (i) IR Value both in open and close position (ii) Continuity of breaker in closed position (iii) Tripping and closing of breaker (iv) Functioning of all the tripping system/relays displayed on the control relay panel, such as differential O/C, earth fault , metering circuits and all other protection emanating from transformer- oil temp trip, winding temp gauge trip, buchloz relay, inter trip etc, calibration of all the relays and complete VCB for time obserbed with respect to time set primary injection of all the CTs complete all as specified and directed. (v) Greasing/oiling of all the moving parts. (vi) Operation/working of charging motor and limit switch. Testing of under 11 KV, VCB breaker - The equipments to be tested are as under :- (A) Following test to be carried out on each breaker (i) IR value for open/close circuit- fault relay, over load earth fault relay etc. (ii) Tripping and closing time in M/S. (iii) Operation - both manual and through motor. (iv) Functioning of indicators.
(v) CT ratio through primary injection. (vi) Polarity test. (vii) Testing of all the protetion relay i.e O/C, eath fault, instantaneous, trip suspention, and auxiliary relay etc, calibration. (viii) Operation/working of charging motor and limit switch. (ix) Calibration of all relay , male , female contacts of VCB. (x) Earthing. (B) Testing of control and relay panel for 33KV/11KV transformer 2000 KVA & 1600 KVA- 03 Nos. (C) Testing of 36 KV, 31.5 KA current transformers - 3 set. (D) Testing of 36 KV, 31.5 KA Potential transformers - 3 set. (E) Testing of 36 KV , lightening arrestor expusion type 100 KA discharge- 03 sets. (F) Testing of vaccume circuit breaker Incomer 630 Amps through primary and secondary injection kit - 3 Nos. (G) Testing of vaccume circuit breaker Outgoing feeder 630 Amps through primary and secondary injection kit - 5 Nos. (H) Testing of bus couple 630 amps through primary and secondary injection kit - 03 Nos. (J) Testing of fuse set unit 33 KV- 03 Nos. (K) Testing of line Isolator switches- 08 Nos.
Disconnection of all electric connection and taking down old defective unserviceable PT and S&F new 33 KV potential transformer 3 phase , oil cooled type 33/11 KV/110 volts with suitable V A burden per phase accuracy class 0.5 complete including its connection for primary and secondary complete all as specified and directed.
Disconnection of all electric connection and taking down old defective unserviceable CT and S&F new 33 KV current transformer 3 phase , oil cooled type 100/50/5 Amp with suitable V A burden per phase accuracy class 0.5 complete including its connection for primary and secondary complete all as specified and directed.
Disconnecting 33 KV defective limb/pole of the SF6 breaker, and S&F of new limb of SF6 breaker as per sample alongwith its testing complete all as specifed.
Supply and fixing following items in replacement suitable for 33 KV busbar connection/HT system including replacement of following items complete all as specified and directed for following :-
Tee clamps heavy duty
Pad connector heavy duty
PG clamps heavy duty
Univeral connnector heavy duty
Compression type connector for stud type heavy duty terminal.
Dismantling and taking out unserviceable fuse carrier tube from existing DO fuse unit and supply and replace new fuse carrier glass tube with metal fitting on both ends in same DO fuse unit 33 KV complete all as specified and directed.
Dismentling and taking out existing damaged /defective 33 KV post insulator and supply & replacement of new 33 KV post insulators complete all as specified and directed.
S&F in repair for four in series disc type insulator porcelain vitreous 145 cm height and 255 mm dia ball and socket type brown colour for working pressure 33 KV complete all as specified and directed.
S&F in repair pin type insulator porcelain , vitreous, white, brown or green including one galvanised mild steel spindle, two galvanised iron washer and one galvanised iron nut, 260mm height , 290mm dia for 33 KV electric pressure complete all as specified and directed.
S&F in repair lightening arrestor suitable for 33 KV grade , non linear resistance type complete with all fittings transmission class for outdoor discharge capacity 10 KA incl all clamp, nuts and washers with connections and earthing complete all as specified and directed.
M&L for Calibration of VCB CHECKING (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV vaccum circuit breakers any make/type as mentioned below :- (a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each VCB for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge/rep ofEngr-in-Charge and reconnecting the incoming and outgoing HT cables ,complete all as specified and directed. (b) Inspecting, servicing and testing all connections of control wiring availability of proper D.C. supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting incl replacement of faulty control fuses,indication lamp & testing for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge, complete all as specified and directed.
(c) Taking out IDMT over current relay 01 Nos and earth fault relay 01 No from the 11KV VCB (2 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed. (d) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking PT 11 KV/110V of each VCB for insulation and accuracy and calibrating the same in presence of Engr-in-Charge/rep of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete all as specified and directed.
Disconnection & taking out old/defective current transformer (CT) from 11 KV VCB panel and supply ,fixing,intallation & testing of current tranformer ,indoor comprising of 3 Nos single phase resin cast CTs of 300-150/5+5 amps ratio ,PS class ,with suitable V A burden and accuracy suitable for protection & material incl making suitable arrangement for fixing in existing VCB panel and connection complete all as specified and directed. Note:- (i) All the instruments and T & P required for the above jobs shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) The all above checking ,inspection ,installation and testing work shall be performed by auth HT expert engineer.
Supply, installation, Testing & Commissioning of Electronic Numerical self powered programmable type digital Relays having high tourque, low burden ( not more than 5.5 VA) and low over shoot triple pole non directional suitable for 5 Amp current rating and having three over current and one earth fault elements with over current IDMT/ definit time and instant trip, range 20% to 200% in step of 1% per phase and earth fault range of 10% to 80% fault and time setting of 3.0 seconds to 10 times of current setting in steps of 0.1 seconds and accuracy of class 5 confirming to IS 3231 of 1965 including 4.5 volt alkaline battery, flush pattern with accessories duly connected with trip and alarm system - 01 No complete all as specified and directed. NOTE: The contractor has to visit the site to check the existing relay & wiring of 11 KV VCB panel for installation of Microprocessor based relay.
Supply and fix in replacement of Big gear assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model and complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of Small gear assembly suitable for HT 11KV/12KV VCB 630 Amps as per existing make and model and complete all as specified and directed by Engr-in-Charge.
Taking out trolly from VCB , opening of trolly to clean the parts, cleaning of tank, dismentling of existing unserviceable vaccume interrupter and supply, installed testing of vacuume interrupter matching to existing one suitable for 11 KV 400 amps HT VCB complete all as specified and directed.
Dismantling of existing unserviceable bus bar spout after disconnecting all incoming and outgoing connections and S/F new bus bar spout of 11 KV 400 Amps VCB matching to existing one including all incoming and outgoing connection complete all as specified and directed.
Supply and Fix in replacement charging gear for crompton make trolly mechanism 11 KV VCB, complete all as specified & directed
Supply and Fix in replacement operating mechanism for breaker 11 KV VCB complete all as specified & directed
Supply and Fix in replacement teflon hexagonal interlocking bush to complete interlocking with strip complete all as specified & directed as per sample
Supply and Fix in replacement of push button complete all as specified & directed as per sample
Supply and Fix in replacement OFF push button complete all as specified & directed as per sample
Supply and Fix in replacement ON/OFF Indicator complete all as specified & directed as per sample
Supply and Fix in replacement Z type lever of OFF push button complete all as specified & directed
Supply and Fix in replacement Z type lever of ON push button complete all as specified & directed
Supply and Fix in replacement trip coil only Y1 control volt 30 VDC complete all as specified & directed
Supply and Fix in replacement close coil only Y2 control volt 30 VDC complete all as specified & directed
M&L for replacing of phase indicator light LED type for panel in three colours ( R,Y,B) complete all as specified and directed.
S&F in repairs of motor & gear assembly 220 volts AC/DC or as per model suitable for 400Amps HT VCB as per existing make and model and directed by Engr-in-Charge. Make :- Crompton Greeves/Alston
Disconnecting taking out air break switch, gang operated switch HT 33 KV triple pole horizontal/vertical type , mannually operated for repairing and service mounted on insulator, and steel frame with operating mechanism worked from GL, including refixing after repairing by replacement of new spares it required and servicing, complete all as specified and directed. Note:- New spares shall be measured and paid seperately as supply only under respective item of Sch 'A'.
S&F for Female contact or moving contact blade, heavy duty andhigh conductive metal complete capacity 200/400 amps complete all as specified and directed
S&F for Male conatct or moving contact blade, heavy duty andhigh conductive metal complete capacity 200/400 amps complete all as specified and directed.
S&F for Tinned copper flexible jumper 200/400 amps complete all as specified and directed
S&F for Top/bottom contact suitable for 33 KV drop out fuse complete all as specified and directed
M&L for on line Dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified & directed. Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor. (ii) BDV testing report before and after dehydration will be submitted by the contractor from auth workshop/site in presence of Engr-in-Charge (iii) Oil required for topping up the transformer will be measured & paid separately as supply only under respective item of this Sch.
Supply and filling in replacemt transfor oil in transformer complete all as specified and directed. . Note:- Sealed container only will be brought at site with minimum BDV 60 KV Make :- Transol, Power, Savita.
M&L for checking (All connections and mechanism) cleaning servicing overhauling,testing complete of 3 phase 11 KV Ring main unit any type/make outdoor type respectively as mentioned below:- (a) Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and checking CTs 03 Nos of each breaker for insulation and saturation calibrating with the help of primary injection & testing kit for primary triping system in presence of Engr-in-Charge and reconnecting the incoming and outgoing HT cables complete of panels ,complete all as specified and directed. (b) Inspecting, servicing and testing all mechanical & electrical parts and the connections of control wiring availability of proper DC supply and AC supply,incoming and outgoing connections and tightening them,cleaning the contacts and terminal with CTC solution and using the blower for dusting testing it for satisfactory operation raising and lowering mechanism in presense of Engr-in-Charge complete all as specified and directed.
(c) Taking out existing over current relay 02 Nos and earth fault relay 01 No from the 11KV breaker B (3 Nos In each) and calibrating the relays with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping system in presence of Engr-in-Charge complete all as specified and directed. (d) Supplying and fixing gas chamber with SF6 gas. (e) Supplying and fixing of Mechanism compartment. (f) Supply and fixing of bus bar spout (g) Supplying and fixing of self supplied protection relay NOTE : (i) All the instruments,primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the above rates. (ii) All the test record shall be mentioned and signed by the testing engineer and contractor and Engineer-in-Charge. (iii) The above work shall be performed by HT expert/ engineer.
M&L for including transportation from Main Receiving station to Auth work shop and back for opening Dismantling the transformer of capacity 1600 KVA by lifting the top cover taking out the HV leg coil and LV leg coil and draining out the transformer oil in barral and dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil including cleaning the transformer chamber (body) inside and out side throughly with emery paper and cloth than checked the winding and other worn-out parts such as HV/LV coils and other connected items as Tap-changer, breather assembly, bush etc and replacement of new spares i.e. tap changer, bush etc, HV/LV coil rewinding with DPC enamelled copper wire/ strip of adequate size, guage and number of turn complete and connected to existing serviceable strip by jointing with soldring and reinsulation with cotton tape over strip including using insulating material like varnish to limb coil fire proof type and sleeves etc by drying and baking of Insulating material in heating chamber in adequate temprature reassembling the transformer HV/LV connection with help of soldering Dehydration of HV/EHV grade transformer oil including filteration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil.Testing of transformer after reassembly complete on No load at workshop and ON load at site incl painting to the transformer with super enameled Heat resistant paint complete all as specified and directed.
Note -(i) Tap changer,will be Supply and fixed by contractor (ii) M&L for winding of HT/LV coil with DPC enamelled copper/aluminium wire of existing size & guage including insulation shall be measured and paid separately under respective item of Sch 'A'. (iii) Power transformer shall be got repaired from authorised work shop of Manufacturers or any other works shop which have authoristaion from UPPCL for repair of such capacity transformer. (iv) Following test shall be conducted before installation & commissioning on site. (a) Insulation Resistance Test (by 5000 V megger) (b) Ratio Test (c) Double voltage & double frequency Tes (d) Transformer oil value BDV test (e) Tap changing test off load for all tap position
M&L for inclusing transportation from sub stn old cantt to workshop and back and taking down the defective unserviceable transformer from existing site from pole and Sub Stn with the help of man power & chain pully block or by crane etc including dieconnecting all electrical and mechanical connections from the site and carrying to workshop for repair and Opening Dismantling the transformer of capacity 100 KVA to 250 (including 250 KVA capacity of trs ) KVA by lifting the top cover taking out the HT/LT core and draining out the transformer oil in barral including cleaning the transformer chamber (body) inside and out side throughly with emery paper and cloth than checked the winding and other worn-out parts such as HT/LT coils silicor stamping and other connected items as Tap-changer, breather assembly etc and replacement of HT and LT coil and connected to existing serviceable strip by jointing with soldring and re insulated of cotton tape over strip including using insulating material like varnish to limb coil fire proof type and sleeves etc by drying and baking of Insulating material in heating chamber in adequate temprature Reassenbling the transformer LT/HT connection with help of soldering and eplacement of old burnt u/s item including transporting of capacity 63 KVA to 250 KVA(including 250 KVA) including transporting back after repair to the site where recieved and testing of transformer after reassembly complete testing of transformer after repair incl painting to the transformer with super enammed paint complete all as specified and directed. Note :- HT/LT coils and other connected items shall be measured & paid seperately.
Description same all as per srl item No 56 here in above but for 315 KVA to 415 KVA (including 415 KVA)complete all as specified and directed.
M&L for rewinding of burnt HV/LV coil of transformer with TPC enamelled copper wire/strip of existing size & guage incl insulating material complete all as specified and directed .
Supply & replacement of HT/LT bush Insulator complete with rod as per existing material & size and nut suitable for indoor/outdoor type transformer 63 KVA complete all as specified and directed.
Description same all as per srl item 59 here in above but 100 KVA to 250 KVA complete all as specified and directed.
Description same all as per srl item 59 here in above but 315 KVA to 415 KVA complete all as specified and directed.
Supply & replacement of tap changer for adjusting the voltage with brass parts as per sample of existing for indoor/ outdoor type transformer 63 KVA complete all as specified and directed.
Description same all as per item No 62 here in above but 100 KVA to 250 KVA complete all as specified and directed.
Description same all as per item No 62 here in above butt 315 KVA to 415 KVA complete all as specified and directed.
M&L for painting of Transformers of any capacity & any size complete, on all four sides incl top portion of transformer with one coat of synthetic enamel paint after removing dust, dirt & preparation the surface by scratching with emery paper for painting incl transformer details complete all as specified and directed.
M&L for shifting of transformer 11/ 0.433 KV of any capacity from Main Power house to required location at the Old Cantt Allahabad station incl. making all HT/ LT electric connections and disconnectiong all HT / LT connections of faulty transformer of any capacity and restore the electric supply of affected area complete all as spd and directed by Eng-in-charge.
Supply and fixing in repair HV bush Insulator complete with copper rod as per existing material & size and nut suitable for indoor/outdoor type transformer 1600 KVA complete all as specified and directed.
Supply and fixing in repair HV bushing Insulator complete with copper rod as per existing material & size and nut suitable for indoor/outdoor type transformer 2000 KVA complete all as specified and directed.
Supply and fixing in repair LV bush Insulator complete with copper rod as per existing material & size and nut suitable for indoor/outdoor type transformer 1600 KVA complete all as specified and directed.
Supply and fixing in repair LV bush Insulator complete with copper rod as per existing material & size and nut suitable for indoor/outdoor type transformer 2000 KVA complete all as specified and directed.
M&L for filling silica gel in breather of Transformers complete all as specified and directed.
Supply and fixing Heat shrinkable,straight through joint box for XLPE HT U/G cable,33 KV grade suitable for cross sectional area 95 to 185 Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Note :- The rates quoted shall be deemed to be include the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing in replacement cable end termination heat shrinkable type 33 KV grade suitable for sizes of XLPE cable 95 to 185 Sqmm 3 core indoor type complete all as specified and directed.
Supply and fixing Heat shrinkable,straight through joint box for XLPE HT U/G cable,11KV grade suitable for cross sectional area 95 Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Note :- The rates quoted shall be deemed to be include the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing Heat shrinkable,straight through joint box for XLPE HT U/G cable,11KV grade suitable for cross sectional area 120 Sqmm 3 core XLPE out door type XLPE cables complete all as specified and directed. Note :- The rates quoted shall be deemed to be include the charges of fault locator machine/eqpt fromUPPCL or any other elect agency as available.
Supply and fixing in replacement cable end termination heat shrinkable type 11KV grade suitable for sizes of XLPE cable 95 Sqmm 3 core indoor type complete all as specified and directed.
Supply and fixing in replacement cable end termination heat shrinkable type11 KV suitable for sizes XLPE cable 95 Sqmm 3 core outdoor type complete all as specified and directed.
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3 core. The fault located equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge complete all as specified and as directed by Engineer-in-charge
M&L for cleaning of area of 33 KV yards including cutting of shrubs & bushes including surface dressing not exceeding 15 cm deep in any type of soil and site clearance in soft and loose soil including taking out stone aggregate from sub station and refilling evenly (Not less than 80mm thickness) for neat look surface and filled up in low patches with scraped soil to give even and neat look surfaces by removing/uprooting all vegetation hedges shrubs at sub stations complete all as specified and directed. all as directed at site on weekly basis. Complete all as specified and as directed.
M&L for painting of two pole structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coat of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marking three black & two yellow bands width 30cm by fluoroscent pait, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
M&L for painting of four structure of 11m steel poles with cross arms, bracings, clamps of any length and shape for HT overhead line with two coat of aluminum paint including preparation of the existing surface including marking pole numbers in a 15cm dia yellow circle & marting three black & two yellow bands width 30cm by fluoroscent paint, from bottom of pole above coping to 1.5mtr height, complete all as specified and directed.
Taking down carefully switch air break, gang operated, triple pole complete and supply, installing, connection and commissioning switch air break gang operated, triple pole, outdoor type of 15 insulators with drop out fuse, mechanically operated, mounted of insulators and steel frame, with operating mechanism and operating rod of 25mm bore GI pipe worked from ground leel, with locking arrangements, for current rating 400 Amp at 11 KV, complete all as specified and directed.
M&L for cutting triming and vending tree branches along HT/LT over head lines after arranging electrical shut down, including taking all precautions while working on lines contractr using own T&P by the contractor complete all as specified and directed, (For taking shut down toi excute the work min one skilled electrician and four mazdoor for 8 houres/day shall be depolyed on the work).
Supply and fix in replacement only Battery , maintenance free, 12 V, 60 AH including taking down unserviceable battery any type complete all as specified and directed. Make : Exide/Amron/Luminious
Supply & Replacement of silica gel breather of transformer 11/0.433 KV of capacity 63-160KVA complete all as specified and directed.
Supply & Replacement of silica gel breather of transformer of transformer 11/.433 KV of capacity 415 -750 kVA complete all as specified and directed.
Supply & Replacement of silica gel breather of transformer 33/11 KV of capacity 1600-2000 KVA complete all as specified and directed.
Supplying & Fixing GI electrode chemical earthing of high conductive, corrosion resistant, CPRI tested maintenance free chemical earthing pit to achive earth resistance value less than or equal to 3 Ohm & EN voltage < 02 V,pipe in pipe technology based in which primary conductor (Pipe) having 40 MM dia and primary conductor is inserted into secondray conductor having 80 MM dia. The primary conductor is inserted into secondory conductor and space between secondary and primary conductor of earthing electrode should be crystalline compound. The length of this electrodes is min 3000 MM (3 meters) and earth pit's bore hole should be of dia 200 to 250 mm and min depth 3.50 meters. Length of electrode will be increase with connecting of 25 x 4 mm GI strip extra,and total depth should not less than 3.50 meters. Around the earth electrode earth pit borehole should be backfilled with minimum 50 Kg of ground enhencement compound ERIC Contains mixture of Silica sulphate,Alumina, Iron Oxide, titanium Oxide, Calcium Oxide,Sodium Oxide, Zink Oxide etc. ). including RCC earthing pit having 450 x 450 Cl chamber cover all as directed by Engineer-in-Charge.( Note : If less than 3 Ohm result has not acheived at site the contractor is responsible to do grid system to achieve the desired result and no extra payment shall be made to the contractor for making grid system.)
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL with top edge of plate not less than 1.50 m below normal ground level) connected to galavanised earth lead strip 25mm x 4 mm (7.5m) as means of bolts, nuts, check nuts and washer besides brazing at all joints as shown on drawings and including excavation, earth work, GI pipe (ISImark) light grade 40mm bore for protection of GI strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt, PCC 1:3:6, type C-1(using 20 mm graded crushed stone aggregate ) chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40 mm thick pre-cast RCC cover 1:2:4 , type B-1(using 20 mm graded crushed stone aggregate ) reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with mild steel handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade(ISI marked) for watering all as shown in electrical plate No 3 of SSR Part-I and connected to earth test point including testing & taking down of old/ ineffective earthing complete all as specified and directed. Note:- The rates quoted shall also deemed to include the cost of Earth test point and earth wire and protection pipe upto 7.5 meter beyond the earth plates electrode)
M&L for repair of earth pits at substation and of lightining protection by cleaning in and around the chamber,repair /replacement of MS chamber cover /PCC cover slabs ,removing wild growth needs from the area around earth chamber ,provn of salt water in to earth pits ,repair /replacement of funnel ,checking of earth contunity connecting checking and recording of earth results and painting the results and date of testing etc on the chamber , complete all as specified and directed.
Demolition of Brick work or stone boulder masonary built in cement mortar including all quions arches pillar etc. but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed.
M&L for Brick work with Subclass 'B' bricks, straight or curved on plan exc 6mm mean radius built in CM 1:6 exept brick (old size bricks) complete all as specified and directed.
M&L for Brick work with Subclass 'B' bricks, straight or curved on plan exc 6mm mean radius built in CM 1:4 except brick (old size bricks) complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate as in coping complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces with CM 1:4 and finishing the surface even and fair complete all as specified and directed
S&F for mild steel sheet 7mm thick as in covering of drain cut to size, edges beaded if directed, hole punched including fixing with drain top incl beading turning up metered angle, stopped ends etc with handle complete all as specified and directed
Excavation in post holes in soft/loose soil ( or similar holes) each n.exc 0.5 cum getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm watering and removing surplus soil to a distance n.exc 50 M complete all as specified and directed.
M&L for Plain cement concrete 1:4:8 type D-2, using 40mm graded crushed stone aggregate as infoundations, filling and mass complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C2, using 40mm graded crushed stone aggregate as in walls or retaining walls, any thickness, size or shape including pilasters, buttrresses, columns, pillars, boundry pillars and posts (including, caps and bases) complete all as specified and directed.
S&F for Mild steel work as in swan necks for fencing, posts and struts including cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe- 290-Gde E-165 complete all as specified and directed.
S&F for Galvanized, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc complete all as specified and directed. (Each line wire to be measured separately)
M&L for Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint over one coat of red oxide Zinc chrome primer complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh , size and type to any type of standards , rails , straining bolts, etc. including provision of binding wire complete all as specified and directed.
Supply only Chain Link MS galvanised fencing , diamond square type, weighing not less than 1.90 Kg/Sqm and any size complete all as specified and directed.
M&L for surface excavation not exceeding 30 cm deep and averaging 21 cm deep and getting out in soft and loose soil complete all as specified and directed.
M&L for hardcore of gravels of gauge not exceeding 63 mm deposited spread levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed.
M&L sand filling under floors or in foundations incl watering and consolidation complete all as specified and directed.
R.K.ASSOCIATES (BID ID -3082389)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .