Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹8.7 L+₹84,537 (10.8%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹8.9 L+₹1.0 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO not enlisted in appropriate category | |
| 5 | Rejected-Technical | - | Rejected-Technical REJECTED DUE TO not enlisted in appropriate category |
Tender Value
₹15.8 L
EMD Value
₹31,700
Closing Date
10 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA PIN-151201
As per BOQ/Price Schedule
2023_MES_595185_1
GE/BHI/T-41/2023-24
Open Tender
Civil Works
Item Rate
273 days
GE (AF) BHISIANA
As per NIT/Tender documetns
6 documents required · 6 mandatory
₹500
GE (AF) BHISIANA
₹31,700
24 Jul 2023
13 May 2023
12 Jun 2023
13 May 2023
10 Jun 2023
27 May 2023
18 May 2023 - 24 May 2023
Amount
Taking out unserviceable and S&F Air filter suitbale for 1.5/2.0 ton split AC as per existing, complete all as specified and directed by Engr-in-charge office.
Taking out unserviceable and S&F over load protector suitable for window type AC 1.5/2.0 ton capcity complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable PVC drain pipe and S&F with new PVC drain pipe with clamps set of size 40 mm dia complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable PVC drain pipe and S&F with new PVC drain pipe with clamps set of size 20 mm dia up complete all as specified and directed by Engr-in-charge office.
M&L for fabrication of outer shell cover for window type air conditioning of 1.5/2.0 TR capacity and including preperation of surface and applying with two coats of synthetic enamel paint over one coat of primer by spray paintingcomplete all as specified and directed by Engr-in-charge office.
Taking out unservicable MCB and S&F MCB SP 5-20 Amps capacity having breaking capacity 10 KA 'B' curve complete all as specified and directed by Engr-in-charge office.
Taking out unserviceable and S&F copper capilary tube suitable for window/split type AC's water coolers/Refrigerator any capacity/size complete all as specified and directed by Engr-in-charge office.
Dismantling/taking down window type AC 1.5/2 Ton from site, opening, cleaning all dust with the help of air blower including cleaning of condenser and evaporator coil with Soap solution, removing the dust with the help of wire brush, repairing & proper fixing of wiring including thimbles and cleaning of Air filter Nylon and reinstalling AC in the same Location and made air tight to opening with thermacol material all around the window type AC complete and testing on full load etc complete all as directed by Engineer in Charge.
S&F starting relay assembly including cover and clips for air conditioner window type 1.5/2 Ton capacity fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F starting capacitor 100/120 mfd suitable for 1.5/2 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F running capacitor 40/45/50/55/60/36/45 mfd suitable for 1.5/2.0 Ton capacity of window type AC fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F capacitor 6 mfd suitable for blower motor, fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F remote suitable for 1.5/2.0 TR split/window AC any make/type all as specified and directed by Engr-in-Charge.
Taking down/ dismantling of old unserviceable defective sealed compressor of cap 1.5/ 2.0 TR of window type AC and replacement with manufactures re-conditioned compressor company make hermatic sealed compressor of cap 1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut & bolt and washers as required and charging with Refrigerant R-22/1407A to its rated capacity and testing of leakage in the system if any and making good, testing on full load after re-installing the same, complete all as specified and directed by Engr-in-charge office.
S&F in replacement fan blade for window/split AC of 1.5/2.0 TR all as specified and directed by Engr-in-Charge.
M&L for rewiring of complete window type AC of capacity 1.5 Ton with copper wire single core PVC cable of size 40/0.0076 with necessary sleeves, clip, thimble auto sweep switch etc complete all as specified and directed by Engr-in-charge office.
S&F PVC insulated 1100 V grade of size 2.5 sqmm, 3 core PVC round sheathed insulated flexible flate submersible FR copper cable complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable and S&F 16 Amp switch socket combination 3 pin 16 Amp flush type complete all as specified and directed by Engr-in-charge office.
S&F single pole and neutral enclosure with, two pin and earth plug and socket 240 volts complete with one MCB 20/25 Amps including taking down existing all as specified and directed by Engineer-in-Charge.
S&F Blower motor single phase 230 volts, 50 Hz, 1/5 HP, 900 RPM suitable for window type AC of capacity 1.5/ 2.0 TR fixed in replacement complete all as specified and directed.
S&F Filter pad nylon type suitable for window type AC of capacity 1.5/ 2.0 TR fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F evaporator coil assembly complete suitable for window type AC of capacity 1.5/2.0 TR etc complete and recharging the refrigerant R-22/407A and testing fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F condensing coil (copper coil) assembly complete suitable for window type AC of capacity 1.5 Ton etc complete and recharging the refrigerant R-22/407A and testing fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F condensing coil (copper coil) assembly complete suitable for window type AC of capacity 2.0 Ton etc complete and recharging the refrigerant R-22/407A and testing fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F front grill assembly complete suitable for window type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed by Engr-in-charge office.
M&L for cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the window type AC of capacity 1.5/ 2.0 Ton including installation at site and testing on full load complete all as directed by Engineer-in-Charge.
M&L for rewinding of blower motor of window type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engr-in-Charge.
S&F blower and blade assembly complete suitable for blower motor of window/splic type AC of capacity 1.5/ 2.0 TR Ton fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
M&L for repair to voltage stabilizer of capacity 04/05 KVA single phase including replacement of circuit plate, starting relay, voltmeter, fuse terminal box with fuse carrier, rewinding the main transformer with copper wire of existing size and repair / replacement time delay relay (1-2 Min) built-in type designed for low cut off 140/160 volt, high cut off 260/280 volt on single phase, 50 cycle AC supply etc complete all as specified and as directed by Engineer-in-Charge.
Taking out unserviceable temp sensor and S&F Temperature sensor with cold assembly 230 V AC suitbale for split type/cassetter AC of 1.5/2 Ton cap complete all as specified and directed by Engr-in-charge office.
Taking down/dismantling of old unserviceable defective sealed compressor of cap 2/1.50 TR of Split type AC and replacement in with manufactures reconditioned compressor company make hermatic sealed compressor of cap 2/1.50 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut & bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same complete all as specified and directed by Engr-in-charge office.
Taking down /dismantling of old unserviceable defective Rotary compressor of cap 2/1.5 TR of Split type AC and replacement in new rotary compressor of cap 2/1.5 TR by soldering /brazing of copper Tubes and replacement of foundation pads including nut & bolt and washers as required and charging with Refrigerant R-22/R-134a/R-410 to its rated capacity and testing of leakage in the system if any and making good, Testing on full load after reinstalling the same.
M&L for cleaning the gas system with anti corrosive solution and recharging the refrigerant gas R-22/R-134a/R-410/R-32/R-407 with anti moisture substance and replacement of filter along with rectification of leakage system in the split type AC of capacity 1.5/2 TR on including installation at site and testing on full load etc complete all as specified and as directed by Engineer-in-Charge.
S&F decorated frame of plywood/teak ply of size 70mm wide and 3mm thick duly varnished of good quality, all around the window type AC for air tight and fixing with screws on existing wooden frame complete all as specified and as directed by Engineer-in-Charge.
S&F Insulation to refrigerant pipes of split ACs 2.0/1.5 TR any make & type complete with suitable size for suction and discharge refrigerant pipes including necessary clamps etc complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable and S&F thermostat suitable for split/window AC/refrigerator any capacity all as specified and directed by Engr-in-Charge.
S&F in replacement Oscilation motor with swing blade strip for indoor unit of split AC 1.5/2.0 TR capacity same specification /make as per existing one complete all as specified and directed by Engr-in-charge office.
M&L for dismantling/taking down of existing Split type AC of cap 2.0/1.5 TR complete with Indoor/Outdoor unit from existing location with all electric connection and all refrigerant Pipes and matching the existing disturbed surface area, including Refixing/Re-Installation of Split type AC Shifted to new location on suitable wall places complete all as specified and directed by Engr-in-Charge. (Refrigerant Recharging gas, Insulation of Copper tubes, copper tubes measured and paid seprate under respective item) complete all as specified and directed by Engr-in-charge office.
Supply in replacement of Copper Pipe Line of size 1/4" to 1/2" for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Supply in replacement of Copper Pipe Line of size 3/8'' to 5/8" for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable brass suction valve and S&F new suction valve 5/8" suitable for cassette /split type complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable brass suction valve and S&F new suction valve 1/2" suitable for cassette /split type complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable brass discharge valve and S&F new brass discharge valve 3/8" suitable for cassette /split type complete all as specified and directed by Engr-in-charge office.
Taking down unserviceable brass discharge valve and S&F new brass discharge valve 1/4" suitable for split type complete all as specified and directed by Engr-in-charge office.
Supply in replacement of Brass flair nuts 1/2'' to1/4'' for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-charge office.
Supply in replacement of Brass flair nuts 3/8'' to 5/8'' for Split/Window type AC of any capacity complete all as specified and directed by Engr-in-charge office.
M&L for dismantling /Taking down of Window type AC 2/1.5 Ton Capacity from existing location carefully with all electric connection and connecting the same in new location and including the window opeaning filled with the brick masonary and cement plastering to match the existing disturbed surface area complete all as specified and directed by Engr-in-Charge.
S&F Fan motor for Outdoor unit, of same specification as per existing one suitable for Split type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed by Engr-in-charge office.
M&L for Opeaning/Cutting holes in Brick wall suitable for window type AC 2/1.5 Ton and making good disturbed surface area complete with cement plaster and masonary work equired at site and made Air tight to Opeaning with the Thermocoal Material all round the window AC etc complete all as specified and directed by Engr-in-Charge.
S&F Evaporator coil assembly complete suitable for Split type AC of capacity 1.5/ 2.0 TR Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F Condensing coil assembly complete suitable for Split type AC of capacity 1.5 TR Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F Condensing coil assembly complete suitable for Split type AC of capacity 2.0 TR Ton etc complete and recharging the refrigerant R-22 and testing fixed in replacement complete all as specified and directed by Engineer-in-Charge.
S&F Connection lead 3 core PVC sheathed copper flexible cable of size 3.5 core 4 sqmm complete with necessary thimbles etc, fixed in replacement, complete all as specified and as directed by Engr-in-Charge.
Supply and install Voltage stablizer copper winding automatic digital type operation single phase naturally air cooled indoor type and designed for input variation between 150 Volt to 285 Volt with output voltage stablized at 230 Volt with accuracy of (+/-) 2.5 percent of capacity 5KVA .
S&F Blower motor for Indoor unit, same specification as per existing one suitable for Split type AC of capacity 1.5/2.0 Ton fixed in replacement complete all as specified and directed.
Dismantling of existing unserviceable blower motor and providing of new blower motor with shaft type of capacity 1/6 HP single phase of 230 volts AC supply suitable for 1.5 Ton capacity split/window type Air Conditioner complete all as specified and directed by Engr-in-charge office.
Dismantling of existing unserviceable blower motor and providing of new blower motor with shaft type of capacity single phase of 230 volts AC supply suitable for 2 Ton capacity split/window type Air Conditioner complete all as specified and directed by Engr-in-charge office.
M&L for rewinding of Fan motor of window type AC 1.5 Ton capacity single phase 1/5 HP, 900 RPM with super enameled copper wire of existing gauge including replacement of bush and nut and bolts, washer etc complete all as specified and as directed by Engr-in-Charge.
M&L for submain wiring with two single core of 4 Sqmm and one single core of 4.00 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
M&L for submain wiring with two single core of 6 Sqmm and one single core of 6.0 sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non metallic rigid (ISI Marked) PVC conduit of size 25 mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface.
M&L for fixing of dual capacitor suitable for both window/split AC all as specified and directed by Engr-in-Charge.
Dismantling or removing of existing of 1.5/2 TR capacity of split type ACs indoor unit and deposit in MES store and supply with new indoor unit factory sealed and install 1.5/2 TR capacity of split type ACs indoor unit, (copper coil) electric driven single phase, 230 volts, New 3 star rating including all accessories like brackets, rubber tubing, copper tubing, gas charging, etc including testing and commissionin with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as specified and directed by Engr-in-charge office. Note : All cooling /condensing coil should be copper material.
Dismantling or removing of existing of 1.5/2 TR capacity of split type ACs outdoor unit and deposit in MES store and supply with new outdoor unit factory sealed and install 1.5/2 TR capacity of split type ACs outdoor unit, (copper coil) electric driven single phase, 230 volts, New 3 star rating including all accessories like brackets, rubber tubing, copper tubing, gas charging, etc including testing and commissionin with as per norms of BEE and making good to the disturbed surface to match the existing surface complete all as directed. Note : All cooling/condensing coil should be copper material.
S&F in replacement complete PCB with Remote control for Indoor unit of Split type AC cap 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed by Engr-in-charge office.
S&F in replacement complete PCB with Remote control for Outdoor unit of Split type AC cap 1.5/ 2.0 TR, microprocessor based with transmission and receiving unit, cordless with features of mode slection, timer, temperature control or as per existing specification and model complete all as specified and directed by Engr-in-charge office.
S&F in replacement of flexible type water drain out pipe suitable for indoor unit of split AC as per existing make/model complete all as specified and directed by Engr-in-charge office.
Attending day to day complaint of detecting the fault in Refrigerator/ Water cooler/ Window AC/Split /Desert Cooler /Voltage stabilizer/ Electric supply in all equipments like loose nut and bolts, leakage of tube, checking electrical connections, charging of refrigerant, fan motor, compressor fault etc all as specified and directed. Note : (i) Any defective part which are required to be replaced to make functional ACs shall me measured and paid seperately. (ii) The Contractor should attend the complaint and rectify the defect within 02 days (Maximum) failing which Rs. @500 per day per AC (split /window 1.5 / 2TR )/water cooler / Refrigerator will be recovered from the RAR/Final bill.
S&F in replacement Blower drum assembly complete for Split AC of 1.5/2.0 ton as per existing all as specified and as directed.
S&F in replacement LCD Digital type AC timer for cyclic operation of 02 any type of Air Conditioner with displaying AC 1/AC 2 on indication & 1 to 24 hours programmable to take load upto 2 Ton window/split AC with auto/manual facility at site all as specified and directed.
Dismantling of existing unserviceable magnetic door lining and providing new magnetic door lining suitable for refrigerator of 165/300 iltres capacity.
M&L for complete maintenance and repairs of refrigerator of capacity 165 to 310 ltrs including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring, veg tray, chiller tray, strainer, freezer door and timer etc and testing complete all as directed. Notes: Item No. (i) Rates includes servicing of unit for one time and will be considered as one job. (ii) Rates are including for spares required for replacement to make it serviceable for item No. (1 to 4) do not paid separately. (iii) Servicing shall be carried out in the presence of Engr-in-Charge or his representative. Necessary service report (complaint slip) is to be signed by the rep. of AGE E/M. (iv) Old spare parts retrived after replacement will be the property of the cotractor under schedule of credit and shall be removed by the contractor outside at his own cost.
Dismantling of defective compressor sealed unit of refrigerator from existing refrigerator by removing suction/discharge line and providing new approved factory sealed compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F-134/R22/407A including connection suction/ discharge line complete 165 to 310 Ltrs capacity refrigerator.
S&F Thermostat switch with defrosting system suitable for refrigerator of capacity 165 to 310 Ltrs fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F Starting relay assembly suitable for refrigerator of capacity 165 to 310 Ltr fixed in repairs complete all as specified and as directed by Engineer-in-Charge.
S&F Plastic ice tray suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F Vegetable tray with suitable glass cover suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
S&F Lamp assembly including lamp suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F Aluminum freezer suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and directed by Engr-in-charge office.
S&F Plastic Chowki of superior quality suitable for refrigerator of capacity 165 to 310 Ltr fixed in replacement complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable Water cooler tray 80/40, 80/120 ltr and supply and fix new water waste tary stainless steel material including nut bilt, wahser, gas welding work etc in existing water cooler all as specified and directed.
Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F-134 R22/R407 or as existing including connection suction/ discharge line complete 150/120Ltrs capacity water cooler all as specified and as directed by Engr-in-Charge.
Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F-134 R22/407 or as existing including connection suction/ discharge line complete 40/80/60Ltrs capacity water cooler all as specified and as directed by Engr-in-Charge.
Taking down of unserviceable condensor coil and providing new condensor coil of same size and quality for water cooler capacity upto 150 LPH all as specified and as directed by Engr-in-Charge.
Taking out unserviceable and S&F over load protector suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler Make : Shriram/ Ranutrol all as specified and as directed by Engr-in-Charge.
Taking out unserviceable and S&F fan motor suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler all as specified and as directed by Engr-in-Charge.
Taking out defective capacitor and supply and fix running capacitor suitable for 40/80/60/120/150 ltr cap of water cooler Make : Shriram/ Ranutrol all as specified and as directed by Engr-in-Charge.
Taking down unserviceable starting relay and S&F starting relay for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-Charge.
Taking down unserviceable wiring kit and S&F wiring kit for water cooler 2.5/4 sqmm copper wire full set including clips all as specified and as directed by Engr-in-Charge.
Taking down unserviceable fan motor blade and S&F fan motor blade for water cooler cap 40/80/60/120/150 ltrs all as specified and as directed by Engr-in-Charge.
Taking down unserviceable insulation and S&F thermal insulation with fiber glass 15 mm thick for water cooler of any capacity all as specified and as directed by Engr-in-Charge.
Taking out of defective fan motor with coper wound and providing new fan motor of same quality and characteristics suitable to any make of water cooler, type capacity 1/8 HP.
DESERT COOLER
Dismantling of unserviceable wood wool pad and providing new wood pad as per sample not less than 2.5 kg adequate dense new wood wool pad 03 Nos supported with suitable size GI wire & bamboo/wood stick for supporting of wool pad inside complete including fitted with bolts and nuts suitable for existing desert cooler as per sample complete all as specified and directed by Engr-in-charge office.
M&L for Preparation of old painted surface and applying DUCCO paint by spray gun fully matched with its existing colour outside and two coat of black bituminous paint inside the water cooler base compartment including removal of all dust and all foreign material with the help of sand paper and rubbing with cleaning compound and polishing on painted surface etc complete all as specified and as directed by Engineer-in-Charge.
Taking down old Gun-metal, globe or gate valves 20 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one all as specified and as directed by Engr-in-Charge. Make:- Kirloskar/Zoloto/Leader/BIR
Taking down old Gun-metal, globe or gate valves 25 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one all as specified and as directed by Engr-in-Charge. Make:- Kirloskar/Zoloto/Leader/BIR
Taking down old Gun-metal, globe or gate valves 15 mm dia with iron wheel head, screwed both ends for iron pipe and supply fixed new one all as specified and as directed by Engr-in-Charge. Make:- Kirloskar/Zoloto/Leader/BIR
Taking out of unserviceable transparent flexible PVC pipe of 15 mm dia and providing new PVC transperenct flexible pipe of 15 dia, 03 branch minimum length 0.8 mtr long including clamp and of same quality for water circulation pump to air cooler all as specified and as directed.
All as per item No. 99 herein before but flexible PVC pipe of size 20 mm dia.
Dismantling of unserviceable submersible water circulation pump assembly and providing of new submersible electric driven single phase 230 volts, 50 Hz 20 watt water circulation pump, nut bolts, clamp, of head minimum 1.6 Mtr for desert cooler.
Taking down old and unserviceable steel tube /PVC tube of 15mm dia and laying only new GI tube, 15 mm dia, medium grade, galvanised, with all fittings such as tees, bends, elbows, reducers, union etc and fixing accessories such as lock nuts, saddles, pipe hook, etc complete fixed to walls and ceilings or laid in floors for desert cooler connection.
Taking down old and unserviceable steel tube /PVC of 20mm dia and laying only new GI tube, 20 mm dia, medium grade, galvanised, with all fittings such as tees, bends, elbows, reducers, union etc. and fixing accessories such as lock nuts, saddles, pipe hook, etc complete fixed to walls and ceilings or laid in floors for desert cooler connection.
Taking down old and unserviceable steel tube /PVC 25mm dia and laying only new GI tube, 25 mm dia, medium grade, galvanised, with all fittings such as tees, bends, elbows, reducers, union etc. and fixing accessories such as lock nuts, saddles, pipe hook, etc complete fixed to walls and ceilings or laid in floors for desert cooler connection.
M&L for rewinding of exhaust fan motor of desert cooler of size/capacity 4500 CFM Exhaust 1/6 HP1250 rpm including replacement of nut bolts, clamps. Note : The cost shall be included taking down and re-fixing in existing location including clamp nut bolts etc.
M&L for rewinding of exhaust fan motor of desert cooler of size/capacity 5000 CFM Exhaust fan. Note : The cost shall be included taking down and re-fixing in existing location including clamp nut bolts etc.
Dismantling of unserviceable fan blade and providing of new fan blade made out of aluminium casting suitable for existing desert cooler make and model.
M&L for writing MES No of size 25 mm thick with synthetic enamel paint white/black on the body of desert cooler etc. complete all as specified and as directed by Engr-in-Charge.
Dismantling and removing of existing desert cooler, including MS angular frame /MS channels, foundation frames etc, complete and closing of holes of pipe line and drain water opening and making surface goood with plastering and painting to match the existing colour of walls.
Taking down unserviceable capacitor 4 MFD and S&F new capacitor 4 MFD, 400 Volts all as specified and as directed.
S&F control piano switch (ISI Mark), flush type, 5 Amps suitable for existing desert cooler including taking down the old unserviceable switch all as specified and as directed.
S&F plug top, 3 pin, 5 Amps (ISI Mark) including taking down the old unserviceable plug top, all as specified and as directed.
S&F flexible FR PVC round sheathed insulated flexible copper cable of size 1.5 Sq mm, 3 core, including taking down old unserviceable cable all as specified and as directed.
S&F water tray of size 85 cm x 70 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray.
S&F water tray of size 95 cm x 75 cm and height 20 cm, made of GI sheet 0.63 mm thick suitable for desert cooler including taking out old unserviceable tray.
M&L for providing new plywood of 6mm thickness, grade BWR, type BB, fixed with screwes to timber frame work in room windows suitable for desert cooler with grill face opening complete all as specified and directed.
Supply and replace 15 mm ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 142 gms).
Dismantling and removing of existing desert cooler, including MS angular frame /MS channels, foundation frames etc, complete and closing of holes of pipe line and drain water opening and making surface good with plastering and painting to match the existing colour of walls.
Fixing of Desert Cooler any capacity including MS chanels, modification of chanel including installation foundation frames of unit complete and provision of opening of through holes for pipe line and drain water in brick/stone masonary wall and disturbed surface making good with plastering and painting to match existing colour of walls, Note : Item obtained from the Ser No. 127 above shall be reused.
Taking down unserviceable rusted body of desert cooler and M&L new desert cooler body made out of 01 mm thick galvanised steel sheet with wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting wood wool including suitable size top and bottom water tray made of 1.00 mm GI sheet and all fixing accessories for fabrication of complete new outer shell body cover made out of GI sheet (body size 100cmx90 cm) for desert cooler of size/capacity 5000 Cum Exhaust fan type and including preperation of surface and applying with two coats of synthetic enamel paint over one coat of primer by spray painting.
Taking down unserviceable rusted body cover and M&L new desert cooler body cover made out of 01 mm thick galvanised steel sheet with wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14 swg dia fitted on both sides for supporting wood wool including suitable size top and bottom water tray made of 1.00 mm GI sheet and all fixing accessories for fabrication of complete new outer shell body cover made out of GI sheet (body size 100cmx90 cm) for desert cooler of size/capacity 4000 Cum Exhaust fan type and including preperation of surface and applying with two coats of synthetic enamel paint over one coat of primer by spray painting.
Taking down unserviceable desert cooler and supply, installation, testing, commissioning of New desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet with complete fully exhaust fan 450 mm sweep, 1400 rpm motor and suitable capacity submersible pump and wood wool fitted in frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting wood wool including suitable size top and bottom water tray made of 1.00 mm GI sheet 1000 watts speed control electronic regulator, suitbale size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixing accessories complete all as specified and as direcd. Note : All electrical equipments shall be of BSI/ ISI Marks.
Taking down unserviceable angel iron frame wire mesh from existing cooler and supply and fix, frame made from 25x25x3 mm angle iron and 25x25 mm size MS wire mesh net of 14swg dia fitted on both sides for supporting wood wool including suitable size top and bottom water tray made of 1.00 mm GI sheet of desert cooler of capacity 4500 Cum per hour made out of 01 mm thick galvanised steel sheet.
Taking down unserviceable and S&F Exhaust fan motor with blade and frame heavy duty industrial exhaust fan (18 inch/450 mm with IP 55 specification, rigid frame with rubber mounting for silent operation epoxy powder coated and better resistance to corrosion and acid alkali fumes, totally enclosed highly efficient copper wound motor including testing of motor, AC, 230/250 volts, Heavy duty and blades 450mm sweep, suitable for desert cooler of capacity 4500 CFM. Note : The rate shall be included fixing of fan in side of desert cooler, clamp nut bolts, welding arrangement, etc.
Taking out unserviceable bib tap/pillar tap and S&F Bib tap chromium plated Fancy type of size 15mm dia concussive taps of cast copper alloy with chromium coated screwed for iron pipe complete all as specified and directed by Engineer in Charge. Note : The cost shall be inclusive all accessories like socket, union tee, nipple, to fixing of push cock in existing PVC pipe/GI bib/pillar tap of gate valve or stand post tap.
Taking down unserviceable and S&F PVC connection 15 mm size with PTMT nut of length 450 mm complete all as specified and directed by Engineer in Charge.
M/s Luxmi Constructions
Aman Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .