Repairrenovation of standard capacitor make APFC panels installed at Avantika SPS.
2023_DJB_244308_1
NITNo5
Open Tender
Miscellaneous Works
Works
30 days
RITHALA STP SEC 11 ROHINI DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Sub Paisa
₹15,500
1 Aug 2023
10 Jul 2023
18 Jul 2023
10 Jul 2023
18 Jul 2023
10 Jul 2023
Dismantling of defective component of APFC panels such as capacitors , relays, lights , contactors including dismantling of incoming and outgoing connection etc. as required at site.
Supply of Super Heavy duty Round type capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC , complete with terminal cover and discharge device -make standard
Banking of capacitor units to form banks of suitable capacity by electrical interconnection with multistrand copper wires/Al. bus bars using necessary mountings and hardware , etc. as required at site.
Supply of microprocessor based APFC relay with digital display of power factor and other parameters for sensing power factor and giving phased impulses to contactor coils for switching ON-OFF required no. of capacitors on receiving signals from Control CT in the main line- make Standard
Supply of MNX-50 triple pole capacitor duty contactors to replace defective contactors in APFC panel and extension. make L&T/Schneider/Havells
Supply of MNX-32 triple pole capacitor duty contactors to replace defective contactors in APFC panel and extension. make L&T/Schneider/Havells
Supply of triple pole MCB up to 63A to replace defective MCB in the capacitor panel and extension- make L&T/Schneider/Havells
Supply of triple pole MCB up to 32A to replace defective MCB in the capacitor panel- make L&T/Schneider/Havells
Supply of LED indication light of various colours to replace defective lights in various stages of capacitor panel - Make : FTC/standard
Supply of digital Voltmeter 0-500V to replace defective ammeter in the capacitor panel. Make : AE/L&T/Havells
Servicing of panels including complete dusting of all components , cleaning of contact point with CTC solution , decarbonising of various joints , tightening of all nut bolts , sleaving of live parts alignment of doors to prevent ingress of moisture and vermin’s and touching of rusted parts of the panels etc. as required at site.
Installation of all above components in the existing capacitor banks with suitable fabrication work to accommodate new items in the existing enclosure / structure for alignment of components and ease of termination complete with hardware on the mounting structure and termination of existing cables with lugs, tapes etc. complete with earthling of the capacitor banks etc. as required at site.
Testing & commissioning of APFC panels as per required parameters including following :i. Meggering of all equipments for phase to phase, Phase to neutral and phase to earth. ii.Programmingof APFC relays for target power factor iii. All function tests iv. Monitoring of power factor
B.Extension of existing APFC Panel of 125 KvarProving of sheet steel housing for accommodation of 4 no. capacitors of 25 kvar, 4 nos contactor & MCBs complete with aluminium bus bars. As required at site.
Control wiring of all components with 1.5 sq mm multi-strand copper cable with lugs tape etc. as required at site.
Power wiring of all components with 16 sq mm multi-strand copper cable with lugs tape etc. as required at site.
Supply of 120 mm sq. 3.5 core aluminium armoured cable 1.1 kV grade-make Syntron/Paragon/Polycab/Any ISIS marked
Laying and termination of 120 mm sq. cable using necessary clamps, hardware, brass compression glands , lugs etc. as required at site
Checking of capacitors and dismantling of defective capacitors from static capacitor banks including dismantling of terminations, wirings , hardware , as required at site.
Supply of Heavy duty capacitors of various capacities rated at 440V, 50 Hz, 3 phase AC complete with terminal cover and discharge device for replacement of defective capacitors of static capacitor banks -make standard
Banking of capacitor units to form banks of suitable capacity by electricial interconnection with multistrand copper wires/Al. bus bars using necessary mountings and hardware , etc. as required at site.
Installation & connection of capacitors as described above using necessary hardware, mouting arrangement and termination with multistrand copper wires, lugs, tapes etc. as required at site.
bhawani electrical system
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .