GE Chandmandir
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-33/2022-2023 ADDN / ALTN TO BLDG NO P-182, DRAIN AT JESSORE MARG AND REPAIR TO SENIOR VETERANS AT CHANDIMANDIR
2022_MES_532600_3
GE/CHM-33/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹76,900
Yes
21 Oct 2022
23 Aug 2022
21 Sept 2022
23 Aug 2022
14 Sept 2022
30 Aug 2022
Amount
Demolition of brick work built in cement mortar , complete all as specified and directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water, complete all as specified and directed.
Demolition of un-reinforced cement concrete of any description and in any position not other wise specially provided for ,complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not other wise specially provided for ,complete all as specified and directed.
Taking up or down steel tubing of 15/20mm dia with connections, including cleaning for refixing or removal to store , all as specified.
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
Excavation over areas not exceeding 1.5m deep and getting out in hard and dense soil, complete all as specified and directed.
Excavation over areas exc 1.50m but not exceeding 3.0m deep and getting out in hard and dense soil, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base , complete all as specified and directed.
Plain cement concrete 1:4:8, nominal mix, type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete, all as specified & directed.
Brick work with sub class ‘B’ bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 kg / Sqcm) old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
Reinforced cement concrete , 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete , all as specified and directed.
Reinforced cement concrete , 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses, all as specified and directed.
Reinforced cement concrete , 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span , all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter , all as specified and directed.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter , all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc , all as specified and directed.
Mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed .
Mild steel TMT bars 5mm dia and over upto and including 10mm dia, cut to length, bent to shape required, including cranking, bending spirally including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers and binders , all as specified.
Vitreous china wash down water closet pan (pedestal pattern), white , with all fittings including seat cover , fixed as in repair with ‘P’ or ‘S’ trap and making good the disturbed surfaces and to match with existing surface,complete all as specified.
Chromium plated hand jet (health faucet) for 15mm bore pipe with 100cm long flexible tube, including fixing of hook on wall, fixed in repairs, all as specified.
PVC valve less syphonic action type flushing cistern, low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including 32mm dia PVC flush pipe (for EWC), fixed as in repair, complete all as specified & directed.
Angular stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for 15mm bore iron pipe or for unions, fixed in repairs, complete all as specified & directed by Engineer-in-charge.
PVC connections 15 mm size with PTMT nuts of length 450 mm , complete all as specified and directed.
Stone faced cladding tiles of size 230mm x75mm x 15mm, over and including 10mm thick cementious epoxy tile ahesive, includig dismantling of old tiles, complete all as specified and directed.
Glazed earthenware cladding tiles of size 230mm x75mm x 15mm, over and including 10mm thick cementious epoxy tile ahesive, includig dismantling of old tiles, complete all as specified and directed.
Glazed ceramic coloured tiles 300mm x 600mm x 7mm, first quality, as in vertical surfaces like skirting/dado/risers of steps, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over and including 10mm thick rendering in cement mortar 1:4 , including dismantling of old tiles, complete all as specified and directed.
Non skid ceramic coloured tiles, first quality, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.11 Square metre but not exceeding 0.18 Square metre, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick screed bed in cement mortar 1:6 including dismantling of old tiles, complete all as specified and directed.
50mm thick Plain Cement Concrete 1:2:4 type B-1 (using 20m graded crushed stone aggregate) as in sub base flooring, finished even and rough to receive top layer, all as specified and directed.
75mm thick Plain Cement Concrete 1:2:4 type B-1 (using 20m graded crushed stone aggregate) as in flooring, spike rolling to surfaces or making impressions of expanded metal, whilst the concrete is green , including demolition of old concrete, complete all as specified and directed.
Rendering 20mm thick in cement mortar (1:4), in two layers on faces of sunken floors including using water proofing compound , complete all as specified. Note : WPC shall be measured and paid separately.
Water proofing treatment to sunken portion and adjoining walls of kitchen, WC, Bath & Toilet, etc complete all as specified as under:- (a) 15 mm plaster in cement mortar (1:3) mixed with water proofing compound as per manufacturer’s instructions after roughning and cleaning the surface . (b) Applying cement slurry to the surface @ 0.488 kg /Sq. m of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.253 kg/Sq. m and allowing the surface to air cure for 4 hours. (c) Apply another layer of cement slurry @ 0.242 kg/Sq. m of cement mixed with Acrylic based polymer modified cementious composite compound @ 0.126 Kg/Sq. m and allowing the surface to air cure for 4 hours. (d) Curing the sunken portion with water minimum for 48 hours by ponding. (e)Applying 3mm thick APP membranne with bitumen by torch application to the treated sunken surface over a coat of primer as per manufacturers instructions. (f) Joints/Traps/WC/soil pipes shall be properly sealed with approved sealing compound .
Plain cement concrete 1:5:10, nominal mix, type E-2 using 40 mm graded stone aggregate as in filling of sunken floors, all as specified & directed.
Rendering 10mm thick on fair faces of brick work or concrete surfaces, finished even and smooth on walls in cement mortar (1:6), complete all as specified.
Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), including using water proofing compound , complete all as specified. Note : WPC shall be measured and paid separately.
Rendering 1.0mm to 1.5mm thick dune /grit finish ready mixed product with natural stone granules (800, 1000 to 1200 micron) consisting of excellent synthetic/acrylic binder anti cracking anti foaming, anti fungal, anti rusting agent , complete all as specified and directed.
Complete removal of existing treatment of any type from platered/unplastered surfaces of wall,chajja,facia, cantilivers of RCC with mechanical means/grinder completely, preparing the surfaces by filling the cracks/knots/depression with epoxy crack filling compound and applying two coats of weather resistant exterior emulsion (100% acrylic) over a coat of primer including necessary scaffolding and safety arragements , complete all as specified and directed.
Preparing of new platered/unplastered surfaces of wall,chajja,facia, cantilivers of RCC and applying two coats of weather resistant exterior emulsion (100% acrylic) over a coat of primer including necessary scaffolding and safety arragements , complete all as specified and directed.
One coat of white washing on old wall surfaces including preparation of surfaces, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
Complete removal of existiing treatment and preparation of surfaces of walls and applying two coats of cement base paint over a coat of primer, complete all as specified and directed.
Two coats of synthetic enameled paint on steel and iron surfaces over 10 cm width or girth over a coat of red oxide including preparation of new surfaces, complete all as specified & directed.
Preparation of new plastered surfaces and applying wall care putty (average thickness 2mm as required for desired smoothness and leveling of surfaces in two or more layers) and sand papering, making the surfaces even and smooth and applying two coats of interior emulsion paint over one coat of interior wall primer , complete all as specified and directed.
Applying two coats of fiber reinforced elastomeric liquid waterproofing membrane ( Smartcare damp proof from Asian paints or equivalent as approved) as per the manufacturers instructions on floors or walls, all as pecified and directed.
Precast cement concrete louvres and jallies, 40mm thick (measured solid) type B0 (12.5mm aggregate) set in cement mortar (1:4), including all mouldings but excluding frame, fixed in repairs ,all as specified.
15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors ,complete all as specified and directed.
20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors ,complete all as specified and directed.
PVC (SWR) pipes, 75mm bore, single socketed in any length with rubber ring joints, laid in trenches or in floors, fixed as in repairs, complete all as specified and directed.
PVC (SWR) bend any radius for 75mm bore pipe, complete all as specified and directed.
PVC (SWR) floor trap 75mm bore, plain with grating incl jointing with solvent cement, complete all as specified and directed.
20mm thick rendering in Cement and Sand mortar 1:4 over roof slab after cleaning and preparation of surfaces, complete all as specified.
Plain cement concrete 1:2:4, type B-1 using 20mm graded stone aggregage as in roof padding, complete all as specified and directed.
Supply only liquid water proofing compound (ISI Marked), complete all as specified and directed.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane, minimum weight 3.0kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS . The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions, complete all as specified & directed.
Pre- painted galvalume aluminum zinc coating GI based corrugated coloured steel sheet 0.50mm thick ,having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified , all as specified and directed.
Pre- painted galvalume aluminum zinc coating GI based plain coloured steel sheet 0.50mm thick ,having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified , all as specified and directed.
Steel rolling shutters (1 mm thickness of lath) with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: gear operated type with bevel gear box and crank handle , fixed as in repairs, complete all as specified and directed.
Rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates conforming to grade Fe-290 Gde E-165, all as specified.
Factory made precast drain cover of size 1200 x 600 x 100mm (RCC M-35) , complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, all as specified and directed.
Supply and fix, as in repair, steel window, box type, primer coated, 1.00mm wall thickness, with glazing bar and openable shutter prepared to recieve sheet glass, complete including cutting holes, four Nos. for each window and making good dismantled portion in PCC (1:2:4) type B-1. including following fittings welded to frame/ shutter:- (a) Hold fast 150mm out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of 'Z' section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) 'Z' section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 02Nos. per leaf. Note: Glass panes ,wire cloth, painting shall be measured & paid separately under respective items. Design shall be approved from Engr-in-Charge.
All as per serial item No 63 hereinbefore but without glazing bar.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples , all as specified and directed.
3mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each pane, complete all as specified and directed.
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit 20mm bore, terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per serial item 68 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed
All as per serial item 68 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 68 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete all as directed
Switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as directed
Sockets outlet multipurpose 2 in 1 pin, 6 Amps flush type ISI marked all as specified and directed
Sockets outlet multipurpose 2 in 1 pin, 6/16 Amps flush type ISI marked all as specified and directed
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified & directed by Engineer-in-charge.
Supply and fixing sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces after taking out old unserviceable sub main wiring complete by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note : (i) For the purpose of measurement, 2 single core of 04 sqmm and one single core of 04 sqmm cable along with PVC conduit shall be considered as 1 running metre. (ii) Colour code shall be Red for phase, black for neutral and green for earth (ii) cutting chases and PVC conduit will be measured and paid separately
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, all as specified and directed by Engr-in charge.
Supply and fix TPN distribution board double door flush mounting with provisions for MCBs TPN 4 way, 415 volt having IP43 protection complete all as directed
Supply and fix sheet metal enclosure with double door for DBs conforming to IS:8623, IP 43 protection, shrouded neutral bar and cement spill protector, SPN 8 way, 240 volt complete all as specificed and directed.
Supply & fix MCB ,SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Supply & fix MCB ,TPN , 240 volt, 40 to 100Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Supply & fix MCB ,SP , 240 volt, 6 to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
Exhaust fan energy efficient heavy duty metalic body 450mm sweep, 1440 rpm 240 volt, 50 Hz, with louvers heavy duty, single phase including making connection with suitable size twin core cable complete all as specified and directed.
Cutting openings, through brick walls in round shape , for 450mm dia exhaust fan and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including finishing and matching the disturbed surface and removing surplus unserviceable bricks, hard-core, etc..from site and rubbish complete all as specified & directed by Engineer-in-charge.
Material and labour GI bracket made of GI pipe 'Light grade' of sizw 40mm dia 1.5mtr length bend to shape of 120 degree fixed on pole / wall with clamp of size 50x 6 of suitable length with nuts/ bolts and 1.5 sqmm , 2 core flexible wire from conductor / ceiling rose to light fitting complete all as specified and directed.
Supply and fix LED street light fittings 35 watt LED 230 volt AC outdoor type with high pressure die cast aluminium hounsing and heat resistant complete with drive lamp bracket with impact and corrison resistant including thermal management in optical complete all as specified and directed.
Material & labour, earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including galvanized iron strip 25 x 3.15 mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
M/S Trilok chand sharma
KUNDRA CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .