Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical B 184 SECOND FLOOR GUPTA JI PLAZA NHPC CHOWK FARIDABAD HARYANA 121010 FARIDABAD HARYANA 121010 | FARIDABAD | HARYANA | 121010 | Rejected-Technical non Responsive |
Tender Value
₹46.4 L
EMD Value
₹1 L
Closing Date
10 Jan 2020, 6:00 pmClosed
DGM JKPCC Ltd unit Mechanical Srinagar
DGM JKPCC Ltd unit Mechanical Srinagar
Design, Supply, Installation, Testing and Commissioning of Sewage Treatment Plant (SBR Technology) of Capacity 20KLD along with Sewage Network by way of laying RCC NP3 Pipes at SubDistrict Hospital Kokernag, Kashmir.
2019_PWDJK_89464_1
JKPCC/MU/K/46 of 2019-20
Open Tender
Civil Works - Others
Item Rate
90 days
Kokernag
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,500
Yes
FC JKPCC Ltd a/c
₹1 L
Yes
22 Jan 2020
2 Jan 2020
11 Jan 2020
3 Jan 2020
10 Jan 2020
4 Jan 2020
Amount
Construction of Sewer Network by way of Laying RCC Pipes
Trench Excavation in soft/hard soil including dressing of sides and ramming of bottom including all lifts and leads as per directions of site incharge including dressing of the excaveted material at the dumping site complete.
Filling by way of laying Stone Soling / Stone Aggregate
Provinding and laying in position cement concrete of specified grade excluding cost of centring and shuttering - All works up to plinth level (Ratio 1:4:8)
Providing and laying non-pressure NP3 Class (Heavy Duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement: 2 fine sand) including testing of joints etc - 200 mm Dia
Providing and laying non-pressure NP3 Class (Heavy Duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement: 2 fine sand) including testing of joints etc - 250 mm Dia
Providing and laying non-pressure NP3 Class (Heavy Duty) RCC Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 Cement: 2 fine sand) including testing of joints etc - 300 mm Dia
Construction, Laying, Testing & Commissioning of Man Holes Internal Size i) 0.6m x 0.6m x 0.6m - 4 No's II) 0.6m x 0.6m x 0.75m - 5 No's III) 0.6m x 0.6m x 0.9m - 8 No's IV) 0.9m x 0.9m x 1.2m - 5 No's V) 0.9m x 0.9m x 1.5m - 3 No's
Trench Excavation in soft/hard soil including dressing of sides and ramming of bottom including all lifts and leads as per directions of site incharge including dressing of the excaveted material at the dumping site complete.
Centering & Shuttering including strutting, propping etc and removal of form
Providing and laying of Stone Soling tightly hand packed under foundations, footing etc, including ramming and dressing and carriages of material from source to site of work complete in all respects.
Cast in situ of concrete work (1:4:8) nominal maximum size of the stone aggregate 40mm volumetric batching up to the plinth level including curing but excluding form work costs.
Reinforced cement concrete (1:2:4) for Raft excluding the cost of centering, shuttering, finishing and reinforcement.
Manhole covers of varied sizes
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift up to 1.5 m
Construction, Laying, Testing & Commissioning of I) Screen Chamber of Internal Size 1.5m x 0.7m x 2.1m-1No. II )Raw Sewage Sump / Collection Tank / Collection Pit in RCC with Internal Size 1.5m x 1.5m x 3m- 01 No III )SBR Reactors / SBR Tanks of 18 Cum Capacity of internal size 2.4mx2.4mx3.2m with 2 Cum Capacity Inlet Tank of internal size 2.4mx 0.3m x3.2m -01 no. IV) Sludge Sump / Sludge Tank of 4 Cum Capacity of internal size 1.3mx1.3mx2.4m - 01 no. V) Chlorination Tank of 4 Cum Capacity of internal size 1.3mx1.3mx2.4m - 01 no.
Trench Excavation in soft/hard soil including dressing of sides and ramming of bottom including all lifts and leads as per directions of site incharge including dressing of the excaveted material at the dumping site complete.
Centering & Shuttering including strutting, propping etc and removal of form
Providing and laying of Stone Soling tightly hand packed under foundations, footing etc, including ramming and dressing and carriages of material from source to site of work complete in all respects.
Cast in situ of concrete work (1:4:8) nominal maximum size of the stone aggregate 40mm volumetric batching up to the plinth level including curing but excluding form work costs.
Reinforced cement concrete (1:2:4) for Raft excluding the cost of centering, shuttering, finishing and reinforcement.
Providing, assembling and placing high strength Steel bars of Fe 415 (conforming to IS 1786-1985) for RCC work including cost of binding wires in foundation, plinth, lintals, slabs, columns etc.
Supply, Installation, Testing & Commissioning Sluice Valve or Sluice Gate inside Screen Chamber for 200 mm Dia Pipe
Supply, Installation, Testing & Commissioning Sluice Valve or Sluice Gate inside Screen Chamber for 300 mm Dia Pipe
Supply, Installation, Testing & Commissioning Bar Screen Inside Screen Chamber of Stainless Steel (SS 304)
Construction of Plant room/ Operators room
Trench Excavation in soft/hard soil including dressing of sides and ramming of bottom including all lifts and leads as per directions of site incharge including dressing of the excaveted material at the dumping site complete.
Providing and laying of Stone Soling tightly hand packed under foundations, footing etc, including ramming and dressing and carriages of material from source to site of work complete in all respects.
Cast in situ of concrete work (1:4:8) nominal maximum size of the stone aggregate 40mm volumetric batching up to the plinth level including curing but excluding form work costs.
Reinforced cement concrete (1:2:4) for Raft excluding the cost of centering, shuttering, finishing and reinforcement.
Reinforced cement concrete (1:3:6) for beams, suspended floors excluding the cost of centering, shuttering, finishing and reinforcement.
Centering & Shuttering including strutting, propping etc and removal of form
Providing and laying of GSB .The job includes transporation upto the site and laying of earth as required in layers including compaction and ramming
Brick work above plinth level with common burnt clay F.P.S (non-modualar) bricks of class designation 75 with cement mortar 1:6 ( 1 Cement: 6 coarse sand)
Suppling & fixing of wood work (Truss) of 1st class budloo wood including cost of nails and all other charges
Providing and fixing of 1" thick wall lining including cost of frame work and all charges complete job
Providing and fixing 25mm thick 1st class Kail wood Eaves boarding
Providing and fixing of 12mm thick plywood for ceiling and soffit including cost of nails and all other charges
Providing and fixing of 0.63mm thick CGI roofing of approved quality including cost of nails, washers and all other charges
Providing and fixing of PGI ridge 300mm wide and 0.63mm thick
Providing and fixing of first class kail wood work frames, shutters, laminated door shutters35mm thick including all other charges
Frames for door and window
Shutters (G.P / W.G)
Laminated Door shutters
20mm thick Plaster on the inner/outer walls of plant room with mix of 1:4
Providing and laying of cement concrete flooring 40mm thick with floating coat of cement slurry
Providing and applying two coats of wall putty of reputed make
Providing and applying two coats of snocem of reputed brand and manufacture to give an even shade ( two or more coats)
Providing and fitting of followngs hardware items
Aluminium tower bolts of size 100x10mm, 150mmx10mm, handles and hinges with necessary screws etc
Providing and applying two coats of super enameled paint of reputed brand over two coats of wooden primer on door and window.
Providing and fixing chromium plated brass 100mm mortice latch and lock with 6 lever and a pair of lever handles with necessary screws etc complete. Make:-Godrej/Link
Supply / Installation/ Testing / Commissioning Mechanical Components of Plant as per techanical specification
Sewage Transfer Pumps upto 2.5 HP (2W + 1S)
Air Blowers
Diffusors
Decanter
Return Activated Sludge Pumps upto 2.5 HP (1W + 1S)
Surplus Activated Sludge Pumps upto 2.5 HP (1W + 1S)
Interconnecting Pipes 65mm (MS C Class)
Interconnecting Joints / Bends / Flanges 65mm(MS C Class)
NRVs 65mm
Butterfly Valves 65mm
Dosing Tank of 100 Litres in PVC / UPVC
Dosing Pumps 0-3 LPH Flow
Sludge Centrifuge
Clear Water Disposal Pump upto 2 HP
Disposal Line / Network in MS 50mm B Class Pipe with Flanges after every 3-4 pipes and bends where needed
Supply / Installation/ Testing / Commissioning Electrical Components of Plant
Main Distribution Panel/ control panel for all the mechanical equipment as per techanical specification
Providing & Laying of Wires / Cables and Cable Trays
4.0 Sqmm, 3.5 core copper cable
6.0 Sqmm, 3.5 core copper cable
Perforated Cable tray 150mm wide
Electrification of plant room by way of providing 3 lighting points and two 16A heating points including PVC conduits Switches , wires and 3 no's of CFL 18 W each along with allied accessories
SSA Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .