| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC 45 MOTILAL STREET KOLKATA 700013 | KOLKATA | KOLKATA | WEST BENGAL | 700013 | L1 | Accepted-AOC AOC Done | |
| 2 | L2₹20.9 L+₹5.9 L (39.3%)Rejected-Finance 30 DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹21.2 L+₹6.2 L (41.4%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | L4₹22.1 L+₹7.1 L (47.3%)Rejected-Finance 14 SURI LANE KOLKATA 14 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L4 | Rejected-Finance that the bid is not L1 | |
| 5 | Rejected-Technical 28 SAMBHU BABU LANE KOLKATA 700014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | - | Rejected-Technical Due to submit backdated Affidivit Y |
Tender Value
Refer Docs
EMD Value
₹43,013
Closing Date
24 Jul 2021, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE KNHED PW Dte
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Emergent rectification renovation of Electrical works at Super Speciality Block Building under Medical College Kolkata PhaseII EI work 5th floor
2021_PWDE_337271_1
WBPWDEEIIKNHED/Short60Q/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹43,013
8 Nov 2021
20 Jul 2021
26 Jul 2021
20 Jul 2021
24 Jul 2021
21 Jul 2021
120 days
Amount
Dismentling the existing E.I. work by Co's own tools & tackles by maintening normalcy as far as possible as per direction of EIC
Sub Head-A ----Distribution wiring:- Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire (make-KEI/Havells/Polycab) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythene pipe (HDPE) [for vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Anchor, Roma/ Legrand) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed] as per G S. (Sch. Book page-E-25, Sl. No.-5) (different colour for UPS and non-UPS switch & switch board as per direction of EIC) Av. run 12 mtr
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (make-Finolex/Havells) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required Vide page no E 14 Item no 1.b. a) 2 x 1.5 sqmm + 1 x 1.5sqmm
b) 2 x 2.5 sqmm + 1 x 1.5sqmm (for computer board, PP)
c) 2 x 6 sqmm + 1 x 4 sqmm ( from PBDB to LBDBs)
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works Vide page no E 16 Item no 7 a) 20mm size
b) 25mm Size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (Vide page no E 9 Item no 1b) a) 3 x 22/0.3 (1.5 sqmm)
b) 2 x 36/0.3 (2.5 sqmm)
Supplying and Drawing 1.1 KV PVC insulated flexible single core unsheathed copper cable with annealed bare copper conductor (make-Finolex/Havells) in the 40mm dia 3mm thick Poly. Pipe conceal in wall as per G S 4 x 16 sqmm as 3nos Ph. & N + 2 x 10 sqmm as ECC (for UPS connection)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. as per G S Vide page no F5 Item no 9 (For Maintenance & New work) a) 2.5sqmm
b) 4.0sqmm
c) 6.0sqmm
d) 10.0sqmm
e) 16.0sqmm
Sub Head B ---VTPN,HTPN,SPNDB,Change over switch etc. Including maintenance MCB,MCCB etc Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Legrand,2+12 way Enclosure (607712) as to GS. (Vide page no D-9 item no 13)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment Make-Schneider, as to GS Vide page no D-10 item no 14 a) 6 way Enclosure (A9HTND06)
Supplying and fixing 240/415 V Isolator on din rail of existing DBs and necessary connection Make-Schneider, as to GS. Vide page no D-5 item no 6 (For maintenance & new work) a) 415 V, 63A FP for PBDB
b) 240 V, 40A DP for LBDB
Supplying and fixing 240/415V, MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection as to GS. (Vide page no D-6 item no 7) (For maintenance & new work) a) 6A - 32A SP MCB for PBDB (Make-Schneider)
b) 40A (Make L&T) 4pole
c) 63A (Make L&T) 4pole
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment , as to GS. (Vide page no D-12 item no 16) a) 6 way PBDB (Make- schneider)
Supplying and fixing 415V, FP Change over (make -- L&T, cat no CO10630OSOO) with sheet steel enclosure on angle iron frame on wall with nuts bolts etc as per rating a) 63A
Sub Head C--- Plug & socket:- Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire (KEI/Havells/Polycab) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FRLSHF' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Anchor, Roma/ Legrand) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works as per G S (different colour for UPS and non-UPS power board as per direction of EIC) (Vide page no -E-24 Item no-3) a) On Board
b) Separate plug (average run 7.5 mtr)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Anchor, Roma/ Legrand) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as to GS. (make--Anchor, Roma/ Legrand) (different colour for UPS and non-UPS power board as per direction of EIC) (Vide page no E 18 Item no 9.b)
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Anchor, Roma/ Legrand), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as to GS. (make--Anchor, Roma/ Legrand) (different colour for UPS and non-UPS power board as per direction of EIC) (Vide page no E 18 Item no 13)
Sub Head D-----Supply of Fans:- S & D 1200mm sweep ceiling fan (make-- Usha/CG/Orient) complete with blades, canopy, fork, rubber bush, down rod etc. (For Maintenance)
S & D 240V 85 W 1420 RPM 18" (450 mm) dia air circulator fan (USHA Make) (For Lift lobby and Sub Station/AC plant Room)
S & D 250 V 50 HZ, 80watt, 18" (450 mm) high flo ( air delivery-- 4500 CFM, RPM-- 1400) non-oscillating type metal body Wall Bracket fan with inbuilt regulator, double ball bearing, intergally cast LM6 impeller (Make -EPC)
S & D exhaust fan (Make -- USHA, S.Ph TURBO Heavy duty, 1400RPM, ISI Grey) of following sizes (For Sub station,Chiller plant room,Fire panel room etc) a) 12"(30cm)
Sub Head E----Fixing of fans:- Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting Vide page no D 14 Item no 29
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. (Vide page no C-3, Item no 21.a)
Fixing 18" (450 mm) non-oscillating type metal body Wall Bracket fan with necy. 5 mm MS fastner, 20mmX3mm clamp with wooden board as per direction of EIC
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Make-North-West Wipro) on existing Modular GI switch board with top cover plate incl. making necy. connections etc etc. as per G.S.(For Maintenance) Vide page no E-18, Item no 10
Fixing only 18" (450 mm) dia air circulator fan on wall incl. S & F necy. MS fastner, nuts & bolts etc. as reqd.
Fixing exhaust fan of following sizes after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia incl. Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) as per GS. (Vide page no C 4 Item no 28) a) 12" (30 cm)
Sub Head F---S&D of light fittings S/D 4feet single commercial LED type fluroscent light fittings complete with all accessories with 1X18 Wt master(865T81) LED tube lamp corresponding to (Philips make cat no TMC-501P 1XT-TLD 18W)
S/D 4feet single commercial LED type fluroscent light fittings complete with all accessories with 2X18 Wt master(865T81) LED tube lamp corresponding to (Philips make cat no TMC-501P 2XT-TLD 18W)
S & D recessed & surface mounted decorative LED ceiling tile 36 Wt (2'X2' ft) (Make Crompton cat no LCTLRN-36-CDL) incl. S & F flat difcuser (Warranty period of the fitting incl. all accessories for 3 years. The agency have to repair or replace the fittings in case of any problem wihtin 3 days from the date of reporting by co's own tools tackles and technicians) as per direction & choice of EIC
Supplying & D of LED bulk head light fitting (Philips make, cat no-- WT202W P LED 6S CW PSU S1 PC P3495) 10 watts complete set.
Sub Head G---Fixing of light fittings Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.Vide page no C-2 Item no 17
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. Vide page no C-2, Item no 16.
F recess mounted decorative direct - indirect lighting LED luminaire and hanging the fittings by GI wire and 2 no "L" clamp in ceiling as per direction & choice of EIC
Fixing only LED bulk head light fitting complete set as per direction of EIC.
Sub Head H-----Cable works Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/polycab) as mentioned below : a) 4core 16sqmm
b) 4 core 25 sqmm
Laying of cable of following sizes on existing cable tray and binding with suitable size GI wire incl. with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, as mentioned below as to GS:- (Vide page no F 3 Item no 6) a) 4 core 25 sqmm (from VTPN to PDB)
Laying of cable of following sizes on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting as mentioned below as to GS:- Vide page no F 1 Item no 2 a) 4 core 25 sqmm (from VTPN to PDB)
b) 4core 16sqmm
Sub Head I--Gland & socket Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : Vide page no F-4,Item no 7 (For Maintenance) a) 4 core 25 sqmm
b) 4 core 95 sqmm
c) 4core 120sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : (Vide page no F-5, Item no 8b (For Maintenance) a) 4 core 25 sqmm
b) 4 core 95 sqmm
c) 4core 120sqmm
Sub Head J-----cable tray Supply & Fixing of perforated GI cable tray with perforation notmore than 17.5% suspended from ceiling incl. S&F GI connector,6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. (Vide page no D14, item no 34a) a) 300x50x1.25mm (18SWG)
b) 200x50x1.25mm (18SWG)
Sub Head K----Earthing of panel Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. (Vide page no G-2, item no 4a)
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. Vide page no G-3, item no 5c
Sub Head L-----Miscellaneous items 6A Modular switch (Make North West, as per site requirement)
16 A Modular switch (Make North West, as per site requirement)
6A Modular socket (Make North West, as per site requirement)
16 A Modular socket (Make North West, as per site requirement)
200A, 4 way AC/DC terminal block (Size as per site requirement)
160A, 4 way AC/DC terminal block (Size as per site requirement)
100A, 4 way AC/DC terminal block (Size as per site requirement)
Suuper Specility Block of KMCH IS A COVID-19 Hospital Building. (Rate should be quotated including all taxes and duties)
S. A. ENTERPRISE
ALPHA ELECTRICALS
T.D.K. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .