| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC SINCE LOWEST BIDDER | |
| 2 | L2₹11.7 L+₹95,200 (8.89%)Rejected-Finance | L2 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 3 | L3₹12.7 L+₹2.0 L (18.3%)Rejected-Finance NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L3 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 4 | L4₹14.3 L+₹3.6 L (33.5%)Rejected-Finance | L4 | Rejected-Finance SINCE NOT L1 BIDDER | |
| 5 | L5₹15.5 L+₹4.8 L (44.5%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L5 | Rejected-Finance SINCE NOT L1 BIDDER |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
1 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AMRITSAR CANTT
HQ CWE AMRITSAR OLD CANTT
PROVN OF ONE INCOMING AND ONE BUSCOUPLER VACUUM CIRCUIT BREAKER AT 66 KV MRS AT TIBRI MIL STN UNDER GE GURDASPUR
2023_MES_621048_1
CWE/ASR-33/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE GURDASPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE GURDASPUR
₹34,000
Yes
11 Jan 2024
29 Sept 2023
8 Nov 2023
29 Sept 2023
1 Nov 2023
13 Oct 2023
Amount
Supply installing, commissioning & testing HT 11 KV, 3 phase 50 HZ, repturing capacity 350 MVA, indoor type, totally metal clad withdrawable type Vacuum Circuit Breaker (VCB) Incomer panels with copper bus bar of 630 Amp horizontal isolation type VCB of capacity minimum 1200 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25 KA, No of operation of Vacuum Interrupter Bottles for better performance (i) Mechanical life 30,000 cycle (ii) Rated short circuit current -100 Amp. All the main components like VI/VCBRelays/Meter shal be of same make : Schneider/Seimens/ABB panel and VCB parameters are as below:- (i) Rated Voltage level /PF/withstand voltage/impulse level 12 KV/28KV/75KVp (ii) continuous current rating minimum 1200 Amp. (iii) Short circuit withstand current minimum 25 KA for3 Sec. (iv) One No minimum 1200 Amps horizontal draw out type vacuum circuit breaker in 12 KV metal clad floor mounting panel complete with following :-
(a) Mannually & motor operated (230 V, AC, 50 HZ Spring charghed type, Manually and electrically open (electrical -220 VDC) opertation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6 NO+6NC breaker auxiliary contracts in C% service position. (b) Epoxy cast wound current transformet (CT), 11 KV 900450/1-1-1-1A, core 1 : Class 1, 15 VA for 3 phase, core 2 : 5P 10, 15 VA burden with metering and protection. (c) Manual charging of breaker should be done without opening the front door. (d) Cast resin potential transforment 11 KV/V3/110 V/V110V/3, 50 VA CI 1.0 CI 3P and HT fuse at the primary end and 04 pole MCB at the secondary end of the PT (confirming related IS specification) .
Supply installing, commissioning & testing HT 11 KV, 3 phase 50 Hz, repturing capacity 350 MVA, indoor type, totally metal clad withdrawable type Vacuum Circuit Breaker Bus coupler panel including bus riser with Copper bus bar rating 630 Amps horizontal isolation type VCB of capacity minimum 1200 Amps rated current, as per IEC 62271-100-200. The switchgear panel shall be of sheet steel construction not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall be totally dust and vermin proof. The offered panels shall be tested for IAC level of 25KA, No of operation of Vacuum Interrupter Bottles for better performance: (i) Mechanical life-30,000 cycle, (ii) Rated electrical operations-10,000 cycles (iii) Rated Short Circuit Current -100 Amp All the main components like VI/VCB/Relays/Meters shall be of same make : Schneider/Seimens/ABB Panel and VCB parameters are as below:-
(i) Rated Voltage level/PF withstand voltage/impulse level 12 KV/28KV/75KVp. (ii) Continuous current rating minimum 1200A. (iii) Short circuit withstand current minimum 25KA for 3sec. (iv) One no minimum 1200 Amps horizontal draw out type vacuum circuit breaker in 12KV metal clad floor mounting panel complete with following:- (a) Manually& Motor operated (230V, AC, 50Hz) Spring charged type, manually and electrically open (electrical -220 VDC) operation type, incorporating mechanical as well as electrical ON/OFF indication "OFF" push button, test/service position limit switches, with minimum 6NO+6NC breaker auxiliary contracts in C5 service position. (b) Manual charging of breaker should be done without opening the front door.
Note:- For Item No 1 & 2 (i) New VCBs shall be installed in continuation of existing VCBs and shall be inter connected with copper bus bars of rating 1250 Amp. Expenditure on this account for dummy Breaker & bus bar chamber shall be deemed to be included in the cost. (ii) Predispatch inspection of VCB shall be carried out by representative of Accepting Officer. All arrangements for the same shall be made by the contractor within quoted rates. (iii) Drg of VCB shall be approved by GE before placement of order. (iv) Pre-commissioning inspection shall be carried out by Representative of Accepting officer before completion of work within quoted rates / the amount of the all above to be borne by contractor & nothing extra shall be paid.
M&L for earthing complete with galvansed steel earth plates electrode 60cmX 60cm X 6mm thick burried directly in ground ( earth pit not less than 2.25 mtr deep below the ground level ) with edge of the plate not less then 1.5 mtr below the ground level connection to GI galvanised Iron strp 25mmX4mm as earthing lead by means of bolts/nuts chick nut & washers of GI or steel all ghown in electrical plate No 3 of SSR part I connection to feeder piller all as specified including watering GI pipe 40mm bore medium grade PCC chamber using PCC 1:3:6 type C2 C1 cover funnel & wire mesh complete, all as specified & directed by Engr-in-charge.
Supply and laying in replacement XLPE 11000 volts (earthed) cable insulated screened, PVC bedded, galvanised steel strip or wire armoured (under ground) heavy duty electic power cable with aluminium conductor grade of crossectional area 300 Sq mm 3 Core complete, all as specified & directed by Engr-in-charge.
Material and labour for indoor termination 11 KV (Earthed) grade cold shrink type jointing kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm complete, all as specified and directed.
dinesh enterprises
GULSHAN SINGH GHAI AND SON
Kaul Enterprises
UNITED ENGINEERING CORPORATION
R D Bansal
HARPAL ENGINEERS AND BUILDERS
KHAJURIA ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .