SUPERINTENDING ENGINEER EUDC-2
33/11 KV SUB-STATION KALA PATHAR, INDIRAPURAM, GHAZIABAD
ELECTRICAL WORKS
2024_PVVNL_921561_1
35/W/2023-24/EUDC-2/GZB
Open Tender
Electrical Works
Item Rate
180 days
UNDER EUDC-2 GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER EUDC-2
₹58,000
13 Aug 2024
5 Apr 2024
10 Jul 2024
5 Apr 2024
10 Jul 2024
6 Apr 2024
Amount
fo|qr uxjh; forj.k e.My&f}rh;] xkft;kckn ds vUrxZr leLr [k.Mksa ds dk;Z{ks= esa fctusl Iyku 2024&25 en esa 33@11 dsoh midsUnzksa gsrq oh0lh0ch0] fjys] cSVjh lSV] lh0Vh0@ih0Vh0 o vU; midj.kksa rFkk lqn`<hdj.k vkfn dk;Z bZ&fufonk }kjk okg~; ,tsUlh ds ek/;e ls djkus gsrqA
Safe Carriage of 05 No. Battery Set 24 Volts, 16 No. Battery Charger (Input110-330) Output Float200 AH Battery Current-20A) from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 33 KV Vaccume Circuit Breaker 1250 Amp. from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 33 KV Outdoor Type VCB from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 33 KV CT 400/200/1A from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 11 KV VCB I/C CTR 600/300/5A from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 11 KV VCB O/C CTR 400/200/5A from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 02 No. 11 KV XLPE Cable I/D Jointing Kit 3x300 Sq.mm & 03 No. 11 KV XLPE Cable I/D Jointing Kit 3x185 Sq.mm from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Safe Carriage of 11 KV Bus Coupler VCB Panel from PVVNL Store Sahibabad/Ghaziabad/Noida to site of work including loading & unloading at both side.
Providing and FIXING Chemical Earthing with Terminal Hole. 8mm. Service Life-Up to 12 Years. Terminal Size. 50mm x 6mm Earthing work upto 10 Feet depth. 90mm Galvanized Iron (GI) Chemical Earthing Electrode. All the required material for completion of work will be provided by the contractor.
Providing of 11 KV VCB O/C & E/F (Aashida Make relay Numerical micro-Controller based 4 pole 30/C+1E/F IDMT Protection relay. Auxiliary Voltage- 18 to 230 AC/DC; CT Secondary 1/5 AMP). (Model No. ADR.141A or No. P122/P127 or NEX 101/150 or REF 615). Delivery upto site. Loading and unloading at both ends.
Providing of 33 KV Aashida Make relay Numerical micro-Controller based 4 pole 30/C+1E/F IDMT Protection relay. Auxiliary Voltage- 18 to 230 AC/DC; CT Secondary 1/5 AMP (Model No. ADR.141A or No. P122/P127 or NEX 101/150 or REF 615) Type SPR3HS/T. Delivery upto site. Loading and unloading at both ends.
Providing of 33 KVAashida Make relay Numerical micro-Controller based 4 pole 30/C+1E/F IDMT Protection relay. Auxiliary Voltage- 18 to 230 AC/DC; CT Secondary 1/5 AMP. (Model No. ADR.141A or No. P122/P127 or NEX 101/150 or REF 615). Delivery upto site. Loading and unloading at both ends.
Providing of 33 KV C&R Panel O/C & E/F Relay (Aashida Make relay Numerical micro-Controller based 4 pole 30/C+1E/F IDMT Protection relay. Auxiliary Voltage- 18 to 230 AC/DC; CT Secondary 1/5 AMP. (Model No. ADR.141A or No. P122/P127 or NEX 101/150 or REF 615). Delivery upto site. Loading and unloading at both ends.
Providing of O&U Electronic Relay O/C & E/F Relay Outgoing (Aashida Make relay Numerical micro-Controller based 4 pole 30/C+1E/F IDMT Protection relay. Auxiliary Voltage- 18 to 230 AC/DC; CT Secondary 1/5 AMP. (Model No. ADR.141A or No. P122/P127 or NEX 101/150 or REF 615). Delivery upto site. Loading and unloading at both ends.
Providing required material and making of Galvanised Steel Structure for 33 KV VCB as per RESPO norms. Completer work as per requirement of site.
Providing required material and making of Plinth & Foundation for 33 KV VCB as per RESPO norms. Completer work as per requirement of site.
Providing required material and Earthing of VCB & its Structure as per RESPO norms. Completer work as per requirement of site.
Providiong and Fixing of Copper Control Cable 4x2.5mm. Making required connection as per requirement of site.
Providiong and Fixing of Copper Control Cable 2x2.5mm. Making required connection as per requirement of site.
Providing required material and making of Galvanised Steel Structure for 33 KV CT as per RESPO norms. Completer work as per requirement of site.
Providing required material and making of Plinth & Foundation for 33 KV CT as per RESPO norms. Completer work as per requirement of site.
Providing required material and Earthing of CT & its Structure as per RESPO norms. Completer work as per requirement of site.
Providing and Fixing CT Junction Box as per RESPO Norms.
Providing and Fixing of Nutt & Bolts.
Providing and Fixing of MS Earthing Strip 25x6mm.
Providing and Fixing of MS Earthing Strip 50x6mm.
Work of 11 KV VCB Overhauling of Mechanical Parts alonghwith Replacement of damaged parts.
Work of Overhauling and Replacement of damage parts of VCB.
Dismantle of Old & Damaged VCB/Relay and carriage to JE Store/PVVNL Store Sahibabad/ Ghaziabad including loading and unloading at both ends.
Shiam and sons
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .