Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹33.4 L+₹44,425.40 (1.35%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | L3₹36.4 L+₹3.4 L (10.3%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest Bidder | |
| 4 | L4₹36.7 L+₹3.7 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest Bidder |
Tender Value
Refer Docs
EMD Value
₹97,000
Closing Date
12 Aug 2021, 6:00 pmClosed
GE Kapurthala
Kapurthala
Provn of Certain Sanctioned LBW and Special Repair works at New and Old Mil Stn Kapurthala under GE Kapurthala
2021_MES_460425_1
GE KPT-70/2020-21
Open Tender
Civil Works
Item Rate
270 days
Kapurthala
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Kapurthala
₹97,000
19 May 2022
16 Jul 2021
14 Aug 2021
16 Jul 2021
12 Aug 2021
22 Jul 2021
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding ( but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness(below or above ground level) complete all as specified and directed by Engineer-in-charge.
M/L for glazed ceramic coloured tiles in vertical surface 300 x200 & 7mm thick, set jointed in neat cement slurry & pointed in white or colour cement to match the colour,over & including 10 mm thick cement screed bed (1:4) complete all as specified and directed by Engineer-in-charge.
M/L for non skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06sqm but n.exc 0.11 Sqm in floor set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles, over & including15 mm thick cement screed bed in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for machine cut kota stone slab flooring 20-25mm thick over screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbishing and polishing complete over and including 20mm thick screed bed in CM 1:6 all as specified.
All as per item no 5 here in before but as in skirting / dado including cement plaster in CM 1:4 ,15 mm thick complete all as specified.
M&L for PCC type B-0 (1:2:4) (12.5mm stone graded aggregate), 40mm thick for receiving top finishing layer of ceramic tiles for sunken portion finished even and smooth etc complete all as specified and directed.
Demolition of brick / block masonry built in CM including all quoins, arches, pillars etc and clearing off the premises complete all as specified and directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed by Engineer-in-charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
Use and waste of formwork to chajjas and similar items including edges rough finished complete all as specified and directed by Engineer-in-charge.
M&L for TMT bars 10mm dia and over cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-charge.
M&L for mild steel reinforcement TMT bars 6mm dia to 8 mm dia cut to length bent to shape required, including cranking, bending hooking etc & binding with mild steel binding steel wire (annealed) not less than 0.9mm dia complete all as specified and directed by Engineer-in-charge.
M&L for RCC 1:1.5:3 type A-0 using 12.5 mm graded crushed stone aggregate as in chajjas etc. complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster on brick work or concrete surfaces including racking out joints complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on brick wall or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick Rendering in CM 1:4 on brick work or concrete surfaces finished even and smooth etc complete all as specified and directed by Engineer-in-charge.
M&L for 5mm thick rendering in CM 1:3 on brick work or concrete surfaces finished even and smooth w/o using extra cement in Ceiling etc complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered surfaces of walls and applying one coat of Birla white putty to obtain the true line to achieve smooth surface and applying two coats white wash on ceiling complete all as specified and directed by Engr-in-Charge
M&L for preparation of new plastered surfaces of walls and applying one coat of Birla white putty to obtain the true line to achieve smooth surface and applying two coats of oil bound distermper complete all as specified and directed by Engr-in-Charge
M & L applying two coats of cement base paint on newly plastered or unplastered wall surface over a coat of cement primer including preparation of surfaces, complete all as specified and directed by Engineer-in-charge.
M&L applying two coats of cement base paint on old plastered or unplastered wall surface including preparation of surfaces, complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed by Engineer-in-charge.
M&L for 75mm thick PCC 1:3:6 type C2 as in plinth protection finishing the surface even and smooth with out using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D2 using 40mm graded aggregate 100mm thick as in sub base complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area not exc 1.50 sqm each complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or framed with shutter (with out taking off shutters from the frame) area exc 1.50 sqm but n. exc. 4sqm each complete all as specified and directed by Engineer-in-charge.
S/F solid PVC door frame of size 50x47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening complete all as specified in SSR and directed by Engineer-in-charge.
S &F factory made solid Panel PVC moulded door shutter, 30mm thick (style) consisiting of frame made out of MS tubes for top and bottom rails. M.S. frame shall covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail, bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, suppling and fixing in the frame at site as per specification and drawing including fittings complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames made up from 1mm thick sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, size of frame 105 x 60mm complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C2 as in filling of chowkhats complete all as specified and directed by Engineer-in-charge.
S&F factory made 2nd class, hard wood, 35mm thick glazed and skeleton shutters, open rebated and prepared to received glass, gauge, etc ( without sash bars) edges of framing plain, chambered or rounded, fitted with cut and mitred beads for securing glass , etc but divided into squares with plain chamfered or rounded mirted and rebated sash bars any numbers sizes of members of shutters as specified and directed by Engineer-in -Charge
S&F PVC cupboard frame of size 75mm x 40mm with wall thickness of 5mm made out of extruded 5mm thick Plain/Printed/Prelam PVC sheet reinforced with 15mm x 15mm M.S. square tubes of 19 gauge thickness throughout the frame and mitre cut at two corners and jointed with 2 nos. of 150mm long brackets of 10mm x 10mm M S square tubes. The door frame shall be fixed to the wall using 65/100mm long MS screws through the frame by using PVC fasteners complete all as specified and directed by Engineer-in-charge.
S&F factory made PVC cupboard shutter flush type of 25mm thickness consisting of panel of hollow PVC profile of 12mm x12mm inserted all around the hollow profile section and insert one 10mm x 10mm MS tube in the centre of this section and lipped with 10mm thick(5mm x 2) and 12mm wide on stiles and rails using solvent cement the inner panel shall be laminated with 5 mm thick termite proof waterprrof and fire retardent printed PVC sheet using solvent cement on both sides of panel complete all as specified and directed by Engineer-in-charge.
S &F factory made 2nd class hard wood Plain, framed, panelled shutters 35 mm thick (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-charge.
S&F alumunium hinges for PVC door shutter, size of hinges in 100mm complete all as specified and directed by Engineer-in-charge.
S&F Aluminium anodised, barrel tower bolts of extruded section and fixed, length of bolt 150mm complete all as specified and directed by Engineer-in-charge.
S&F extruded aluminium alloys handles frabicated type anodized of size 150mm long complete all as specified and directed by Engineer-in-charge.
S&F 300mm long mild steel sliding door bolt plate type stove enamelled black and bright bolt not less than 12mm dia including a minimum of 6 nos of nuts and bolts all as specified.
S&F mild steel barrel tower bolt, stove enamelled black, with bright bolt of 150mm size
S&F mild steel pressed handle , oval type stove enamelled black of size 125mm.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, length of bolt in 250mm
M&L for preparation of new wooden surface exceeding 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new steel surfaces of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint over red oxide primer all as specified and directed by Engineer-in-Charge.
S & F steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises glazed Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC (1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Glass and painting shall be measured and paid separately under appropriate item (ii) Irrespective of whatever shown on drgs, MS gills shall be of 12mm dia MS square bar complete all as specified and directed by Engineer-in-charge.
S&F steel window 1.25mm thick Box type ( primer coated) ERW hollow P section of size 60mm x 25mm single rebated comprises gauged Skelton shutter ERW Sec 50mm x 20mm and 1mm thick with one or two openable leaf consisting two Nos sash bar of T- Section 20mm x 3mm complete welded to frame with one vertical mullion of ERW box type T- Section of size 60mm x 25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC ( 1:3:6) type C-1 Four Nos for each window) including following fitting welded to frame shutter: (a) Mild Steel Hold Fast,150mm long of 12mm Square bar made to shape – 04 Nos per window (b) Handles of Z Sec 20mm x 100mm long (c) stopper – 01 No per leaf (d) Cleat 55mm long of hollow square 15mm x 20mmx63mm welded to hinges – 01 No per leaf (e) Mild steel Pintal hinges of size 75mmx75mmx12mm-02 Nos per leaf (f) Grills made out of MS square bar 12mm dia welded to FI frame complete all as specified and shown on drawings. Note: Wire mesh and painting shall be measured and paid separately under appropriate item etc complete all as specified and directed complete all as specified and directed by Engineer-in-charge.
S&F 4.00mm thick plain glass in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge.
S&F 4.00mm thick figured glass, pinhead type in squares n exc 0.5 sqm each pane and glazing with oil putty complete all as specified and directed by Engineer-in-charge.
S/F in repairs for stainless steel wire cloth 0.56mm nominal dia of wire and avarage width of aperture 1.00mm and fixed with tinned tacks/screws with bolts including leaping wooden complete all as specified and directed by Engineer-in-charge.
M/L for framed work such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walk ways railings framed work of water tanks and similar work complete all as specified and directed by Engineer-in-charge.
S/F in repairs of size 300mm MS ordinary rat tail rod pattern helical springs including roller and roller plate complete all as speicified
Taking down GI tubing & connection 15mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
S&F GI tubing 15mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
Taking down GI tubing & connection 20mm dia laid in floor / trenches or fixed to walls complete all as directed by Engineer-in-Charge.
S&F GI tubing 20mm dia medium grade galvanized with all fittings & fixed complete to walls & ceiling or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15 mm bore CP bib taps fancy type cast copper alloy with crutch or butter fly handle screwed down for iron pipe or for brass ferrule and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repairs 15mm dia stop valve, CP cast copper alloy with crutch or butterfly handle. Screwed down high pressure, screwed both ends for iron pipe and fixed complete all as directed by Engineer-in-charge.
Supply and fix in repairs vitreous china squatting pan Orissa pattern wash down water closet of size 580x440 mm, white, with integral foot rests complete with and including P or S trap, PVC flushing cistern low level of 10 ltrs capacity including brackets for flush tank, PVC flush pipe and all necessary fittings etc complete all as specified and directed by Engineer-in-charge.
S&F 20mm dia aluminium chromium plated tubular towel rails,D type,60cm long between flanges, complete all as specified and directed by Engineer-in-charge.
S&F in repairs CI Nahani trap with grating and diameter of outlet 100mm including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-charge.
S&F in repairs fancy type chromium plated stop valves with long shank and cup (concealed type) cast copper alloy screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed for bore size 15mm complete all as specified and directed by Engineer-in-charge.
Supply and fix for vitreous china ware wash basin white, flat back size 550 X 400mm including 15mm dia pillar tap chromium plated, CP waste coupling, waste fittings, union and waste pipe 32mm dia of required length and all necessary inlet, out let connections complete all as specified and directed by Engineer-in-charge.
S&F in repairs shower rose of chromium plated any colour or fixing with 15mm bore pipe (minimum weight 40gm) complete all as specified and directed by Engineer-in-charge.
S&F in repair kitchen sink with drain board made of stainless steel 1mm thick sheet with plugs, washers and wastes including bedding in cement mortar including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-charge.
S&F soap dish, vitreous china white approx size 160x160x90mm complete all as specified and directed by Engineer-in-charge.
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden plastic cleats(min. weight 300gm) complete all as specified and directed by Engineer-in-charge.
S&F in repair anodised aluminium alloy curtain rail chromium plated with fixing brackets, stops, roller etc as specified and directed complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete(unreinforced) in ground floor n.exc 15 cm thick below or above ground level complete all as specified and directed by Engineer-in-charge.
M&L for Applying evenly a tack coat of industrial bitumen 85/25 @ 1.20 Kg/sqm including cleaning surfaces complete all as speciified and as directed by Engineer-in-Charge.
M&L for PCC (1:5:10) type E2 using 40mm graded aggregate 75mm thick as in sub base complete all as specified and directed by Engineer-in-charge.
M & L for Cutting chases pinning in brick/stone/blocks masonary in making good to facings where required and pointing in CM (1:3) to ends or eges of steps, cills, sun shades, shelves, lintel etc and cutting chases for concealed water tubing or etc and making good, complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes including all fittings complete all as specified and directed by Engineer-in-charge.
S&F 110 mm PVC (SWR) pipes in repair single socketed in any length with rubber ring joints fixed to walls complete all as directed by Engineer-in-Charge.
S&F 110 mm PVC (SWR) bend complete all as directed by Engineer-in-Charge.
S&F PVC (SWR) junction single,(single T) equal or unequal complete all as directed by Engineer-in-Charge.
Dismantiling water tank PVC 1000 Ltrs and removing from site complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded three layer polythelene water storage tanks cylindircal water tank for hoisted and fixed in postion of 1000 ltrs capcity including fittings and as directed by Engr-in-Charge
S&F gunmetal globe and gate valve with iron wheel secrewed both end and for iron pipe 20mm fixed in repairs complete all as specified and directed by Engineer-in-charge.
S& F in repairs Ball valves 20mm high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210 gms./25mm-455gms/ 40mm - 690 gms) complete all as specified and directed by Engineer-in-charge.
Dismantling of brick tiles on terracing tiles laid bedded and pointed in cement mortar in single layer on roofs complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof any thickness including in plastering & leeping removed complete all as specified and directed by Engineer-in-charge.
M&L for rendering 10mm thick cement mortar 1:4 on concrete surface even and smooth with waterproofing compound complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound.
Preparation of newly plastered surface making surface completely dry and applying a coat of bitumen primer confirming to IS :3384-1965 @ 0.30kg/sqm and after drying of primer apply APP modified water proofing membrane with non woven polyster reinforcement 3mm thick superior multipolymericweighing not less than 3kg/sqm with properties of high penetration and centre core consisting of 90 micron high molecular high density polyethylene (MHHDPE) film consisting of five layers laid with torching application to the surface over a coat of hot blown bitumen 85/25 @1.20 Kg/Sqm complete and sealing the side as well as end laps (overlaps should not be less than 10 cm) complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on 15mm screed bed in cement mortar 1:6 with jointing and pointing in cement mortar (1:3) mixed with 5% crude oil by weight of cement complete all as specified and directed by Engineer-in-charge.
Ditto all as per item no 86 above but except brick tiles complete all as specified and directed by Engineer-in-charge.
Dimantling cast iron soil waste or vent pipe any dia , any length with or without ears with fittings, fixed to walls or taking out of trenches complete all as specified and directed by Engineer-in-Charge.
Supply and fixed Cast iron soil, waste and vent pipe 100mm bore, in any length with or without ears, with cement joints, laid in trenches or to walls complete all as specified and directed by Engineer-in-charge.
Supply and fixed 100mm bore CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fixed in repairs complete all as specified and directed by Engineer-in-charge.
Supply and fixed Stack clamps suitable for 100mm bore CI pipe made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof , complete all as specified and directed by Engineer-in-charge.
Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including wind tie complete all as specified and directed by Engineer-in-charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer-in-charge.
Dismantling timber scantling 40 sqcm and over in section as in unframed work complete.
Supply and fixing Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Supply and fixing Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
M&L for 12 mm thick perforated particle board 600 x 600 for ceiling including with and aluminium snap grid frame work of 605 x 605mm and hangers 6 mm dia GI upto (1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x 3mm size 60mm long and expansion hold fastner 12.5 mm dia 40mm long including two coat OBD complete all as specified and directed by Engineer-in-charge.
S & F steel work in tubular/square/ rectangular trusses, rafters, purlin and posts etc including special shaped washer etc.complete using ERW or induction butt welded tubes conforming to IS-1161-1979(grade-st-240) all as specified and directed by Engineer-in-charge.
M&L for rolled steel sections as in main and cross beams, hip, jack raffters ,purlins where connected to common rafters Fe 410(grade E-250 quality-A)including a shop coat of red oxide complete all as specified and directed by Engineer-in-charge.
S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.Fe-410(Gde-E250) all as specified and directed.
Excavating in trenches in soft/ loose soil not exceeding 1.50 m wide and not exceeding 1.50 m in depth for foundation for pipes, walls, cesspits, manholes, pier holes, cables etc not exceeding 10 Sqm on plan and not exceeding 1.50 m in depth and getting out complete all as specified.
Returning, filling in, spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each layer complete all as specified.
Removal of excavated soil to a distance exc. 50m but not exc 100m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified.
M & L for Cutting into existing manhole for connecting new drains and making good for 150 mm bore pipe and rendering, cutting out existing benching and forming branch (1/2 or 3/4 section) channel in plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregates, surface finished even and smooth and reforming benching as required.
M&L for RCC pipe 300mm bore class NP-2 laid and jointed in cement complete with collars, laid in trenches, and tested complete all as specified and directed
M&L for concrete bed to drain pipes 300mm bore in cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed
M&L for RCC pipe 200mm bore class NP-2 laid and jointed in cement complete with collars, laid in trenches, and tested complete all as specified and directed
M&L for concrete bed to drain pipes 200mm bore in cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed.
M&L for pre cast cement concrete 1:2:4 as in man hole covers type B-1 (20 mm graded agg) set in cement mortar 1:6 complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or slopping) for rough finished surface of concrete complete all as specified and directed.
Use of waste of formwork for fair finished surfaces of walls, retaining walls, abutments, parapets and stair case railing and similar works vertical or batter all as specified and directed.
M&L rendering 10 mm thick cement mortar 1:3 on fair faces of brick work or concrete surfaces of walls using water proofing compound @ 3% finished even and smooth without using extra cement all as specified. Note : WPC shall be measured and paid for separately.
M&L cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation, filling and mass concrete etc. complete all as specified.
M&L for rolled section as in framing for clading, glazing and the like fixed with angle cleats and connecting plates etc confirming to Fe-290 Gde E-165 complete all as specified.
M&L for reinforced cement concrete M-30 (Design Mix) using 20mm graded crushed stone aggregate as in walls, retaining walls, basement walls, manhole walls straight or curved complete all as specified and directed.
M&L for M-30 design mix using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete M-30 (Design Mix) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs and in shelves and the likeand the like, any thickness above top of footing, including attached pilasters and buttresses complete all as specified and directed.
M&L for construction of soakage wells including excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, with 12mm TMT reinfor cement, interconnecting pipes of RCC/DWC complete filled with brick bats of size3.00mdia and 4.5m depth complete as directedcomplete filled with brick bats of size3.00mdia and 4.5m depth complete all as directed & as specfied.
Taking down aluminium point wiring for light, fan, bell socket, power socket etc complete including fittings and fixtures removing from site and making good disturbed surfaces of walls, floors, etc complete all as directed by Engineer-in-Charge.
Material and labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC (FRLS) insulated cable in PVC concealed conduit of size 20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 1.5 Sqmm insulated un-sheathed PVC insulated copper conductor common earth and connecting to earth dolly for :-
(a) One light point controlled by one, one way switch
(b) One fan point controlled by one, one way switch
(c) One socket outlet 3 Pin, 5 Amp on independent board
(d) One socket outlet 3 Pin, 5 Amp on same board.
(e) One bell point controlled by one bell push
M&L for point wiring with 2.5.00 Sq mm single core multi-stranded copper conductor PVC (FRLS) insulated, unsheathed cable 1100 volt grade in PVC concealed conduit of size 20 mm (ISI Marked) including PVC accessories (concealed in wall and surface in ceiling complete including cutting chasing & making good to disturbed surface etc including pressed steel terminal boxes (sunk in wall) with 3 mm thick plastic laminated sheet top cover with 2.5 Sq mm single core, multi-stranded copper conductor, PVC insulated, unsheathed cable for common earth and connecting for earth dolly for 5 pin, 15 Amp socket outlet on Independent board.
S&F switch piano flush type single pole one way 5 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F switch piano flush type single pole one way 15 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F Bell push flush type single pole one way 5 Amp (ISI Marked) Make - SSK/Anchor/Cona
S&F socket out let 2 in 1, 3 pin 5 Amp flush type (ISI Marked) Make - SSK/Anchor/Cona
S&F socket out let 2 in 1, 3 pin 15 Amp flush type (ISI Marked ) Make - SSK/Anchor/Cona
S&F modular switch 6 amp 230 V AC one way, one module complete all as specified
S&F modular switch 20 amp 230 V AC one way, with indicator one module complete all as specified
S&F Modualr Socket 6A, 2/3 pin two module combined complete all as specified.
S&F Modular socket , 6A/16A, 2/3 pin, two module complete all as specified.
S&F modular fan regulator step type, 120W, 2 module complete all as specified
Taking down old unserviceable regulator & supply & fix electronic type fan regulator stepped type on existing phenolic laminated sheet etc. suitable for ceiling fan.
Supply & fix in repiar single pole and neutral enclosure (MODULAR AC BOX) 4 module in sheet steel with a two pin and earth plug and socket Cat Part No DSDMCDP0251025 of STANDARD or equivalent in Indoasian/Schneider/Siemens/Legrand complete with one single pole MCB 25 Amp 10 KA complete all as directed
Supply and fix Metal flush mounting box of 1/2 Module complete all as specified and as directed. Cat part No 689007 of Legrand (Arteor) or Equivalent in Schneider (Opal)/Anchor (Ave).
Supply and fix Metal flush mounting box of 3 Module complete all as specified and as directed. Cat part No 689008 of Legrand (Arteor) or Equivalent in Schneider (Opal)/Anchor (Ave).
Supply and fix Metal flush mounting box of 4 Module complete all as specified and as directed. Cat part No 689009 of Legrand (Arteor) or Equivalent in Schneider (Opal)/Anchor (Ave).
Supply and fix Metal flush mounting box of 6 Module complete all as specified and as directed. Cat part No 689009 of Legrand (Arteor) or Equivalent in Schneider (Opal)/Anchor (Ave).
Supply and fix white colour plate with frame for moular blanking plate, one module complete all as specified and directed Cat part No 573649 of Legrand (Arteor) or Equivalent in Schneider (Opal)/Anchor (Ave).
Suply and fix white colour plates with frame for modular switch and socket of 02 module complete all asspecified
Suply and fix white colour plates with frame for modular switch of 03 module complete all asspecified
Suply and fix white colour plates with frame for modular switch of 04 module complete all asspecified
Suply and fix white colour plates with frame for modular switch of 06 module complete all asspecified
M&L for ceiling rose, surface Bakelite 65 x 17.50 mm of three terminals PVC/Polycarbonate,isolated body (ISI Marked) Make - SSK/Anchor/Cona
M&L for bell multi music type, AC 230 Volts, single pole (ISI Marked)
Taking down old unserviceable flourescent tube light fitting 36/40 watt fluorescent tube light fittings direct to walls or roof as ordered and disconnecting electrically with the electrical system and all materials required for the same. The rates also include making good the same to match with the existing surface.
Supply, installation, testing and commissioning of 20 watt 4 ft long LED Batten housing made of self ballast ed LED Batten extruded alluminium with PC diffiuser Integral isolated driver >120 degree wide light distribution, available CCT 6500K with all accessories Make Polycab Cat part No INTENSO DLX LED BATTEN 4 FEET 20 W or equivalent in Philips/Bajaj/C&S electric/ Surya
Taking down old unserviceable lamp holder and S&F lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including LED lamp 12W.
Taking down unserviceable MCB’s and supply & fix following type/rating MCB’s including necessary connection as under:-
(a) S & F of MCB, 10 to 32 Amp, SP, 240 Volt Make - C&S, Legrand/Schneider-Acti 9/Siemens-Betagard
(b) S&F of MCB, 25 to 32 to Amp, SPN, 240 Volt Make - C&S Legrand/Schneider-Acti 9/Siemens-Betagard
Taking down old unserviceable sub main wiring 6/ 4.00 Sqmm 1100 volts grade two runs of single core PVC insulated, unsheathed copper condutor, including taking down casing capping/PVC conduit.
M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 4.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 25 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 4.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three run of 4.00 Sqmm cable and one run of PVC Conduit shall be measured & paid as one unit.)
M&L for sub main wiring with two runs of single core PVC insulated, unsheathed copper condutor, multi stranded cable of size 6.00 Sqmm 1100 volts grade drawn PVC concealed conduit of size 20 mm (ISI marked) including PVC accessories complete incl cutting and chasing and making good etc including one run of 6.00 Sqmm single core copper conductor multi-stranded PVC insulated, unsheathed cable as earth wire continuity conductor complete all as specified and directed by Engineer-in-Charge. Note : Three run of 6.00 Sqmm cable and one run of PVC Conduit shall be measured & paid as one unit.)
Taking down old unserviceable wall mounting fitting & supply & fix decorative wall light fixture made up of polycarbonate suitable for 1 x 12 W retrofit LED/CFL rings, and glass shade with lamp holders, connectors block, 1 x 12 watt LED Blub,glass fitted engineering plastic B22 d lamp holder with electrical copper contactcs, self screwed polycarbonate diffuser in opal finish for soothing light effect, LED 15 watt etc complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable complete cat part No LHDL02160099 Make ; Havells or equivalent in bajaj & philips
Taking down old unserviceable bulkhead fitting & supply & fix bulkhead fitting decorative ceiling/wall mounted BULK HEAD with engineering plastic housing and top frame with opal PMMA diffuser suitable for 1 X 06 watt LED Blub including 1 No of 06 watt LED of cat part No CG80IB6WLED of C&S electric or equivalent in model of Philips or Bajaj complete all as specified and directed by Engineer-in-Charge,
Supply and fixing sheet metal enlosure single pole and neutral with two pin socket and earth plug complete with one MCB single pole 240 volts 20 amps complete all as specified and directed by EIC.
S&F Exhaust fans of 230 Volt 300 mm sweep ventilator DB bouble ball bearing heavy duty motor, metal blade with protection steel bird guard and roubst complete including M&L for providing/cutting the round hole of required size in wall finishing the same supply and grounting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated three core 23/.0076 copper cable rubber insulated from ceiling rose to exhaust fan motor and writing MES No. with black synthetic enamel paint 2.0 cm high complete all as specirfied and directed( Make-BAJAJ, HAVELLS, USHA)
Supply and fixing MCB distribution board TPN 4 way double door 415 V with bus bar neutral link complete all as specified and directed.
Taking down old unserviceable DB and supply and fixing factory made sheet metal enclosure double door distribution board class IP-43 with 200 Amp rated copper bus bar 240 volts 8 way single pole and neutral link complete all as directed by Engineer-in-Charge.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric cable (heavy duty) 1100 volts grade with standard aaluminium conductor of size 16 Sqmm 2.0 core
Taking down old unserviceable GI pipe & Supply and fixing 40 mm dia GI tubing light grade complete with all fittings (ISI Marked) lain in trenches/fixed complete to wall and ceiling or laid in floors
Removal of surplus spoil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Material and labour for sand cushioning with a layer of sand 18cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. (Note :- 23 cm thickness if sand after punnping down shall be measured, recorded & paid)
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with length of bricks perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick surrounded with charcoal and salt, buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) Item includes the cost of 7.50m GI pipe for protection of earth wire/strip Any variation in length shall be adjusted through deviation order. (iii) Item includes cost of 7.50m earth lead wire/strip. Any variation in length shall be adjusted through deviation order. (iv) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
COSMO BUILDERS
KAMAL AGGARWAL
Motorway Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .