Executive Engineer (Electrical)
O/o Executive Engineer (Electrical) BSNL Electrical Division 1ST Floor, Bhopal House, Lalbagh Lucknow
Redressing rearrangement of existing electrical supply distribution system at entrance of Sr DDG Office CTO Compound Lucknow
2024_BSNL_181659_1
31/TEDL/BSNL/LKO/2023-24,Dated 05/01/2024
Open Tender
Electrical Works
Item Rate
15 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
ACCOUNTS OFFICER, (Cash), BSNL O/o PGMTD, LUCKNOW
₹2,416
29 Jan 2024
15 Jan 2024
23 Jan 2024
15 Jan 2024
22 Jan 2024
15 Jan 2024
Dismantalling of existing electrical supply distribution system i/c various circuits SFU units,Bus bar chambers with disconnection of cables,wires etc and retermination of all circuit in disrtibution board ,laying of cables,repairing of damage wall plaster,complete testing of distribution system after resoration of supply etc complete as reqd.
Supplying and fixing of following ways surface/ recess mounting,vertical type, 415 V, TPN MCB distribution board of sheet steel,dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.). (a) 8 way (4 +24), Double door
Supplying and fixing 32A rating 415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 32 Amp Triple pole
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (a) 4 way (4 + 12), Double door
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 A Four Pole Isolator
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (b) 100 A Four Pole Isolator
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (a) 100 A, 30kA, FPMCCB
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 6-32A 'C' Series single pole
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (b) 3x4 sq mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the samein case of recessed conduit as required. (a) 20 mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (b) 25 mm
Supplying, Laying and Fixing of 3.5X25sqmm PVC insulated and PVC sheathed / XLPE Aluminium conductor armoured power cable of 1.1 kV grade in following way complete as reqd .
Supplying and installing following size of perforated painted with powder coating M.S. cable tray with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts,painting suspenders etc as reqd. (a) 200mm x 50mm x 1.6mm thick
Supplying and installing following size of perforated painted with powder coating M.S. cable tray bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts,painting suspenders etc as reqd. (a) 200mm x 50mm x 1.6mm thick
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1kV grade as required. (a) 3.5 x 25 sq. mm
(b) 3.5 x 35 sq. mm
© 3.5 x 50 sq. mm
Dismantalling of existing LT Panel with opening of all existing cable connection and retermination of cables in DB i/c shifting of panel at appripiate place /store etc complete as reqd.
Dismantalling of existing aluminium batten wiring,SFU's and shifting of DG control panel and other useless items lying in passage complete with cleaning etc complete as reqd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .