Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹26.9 LQualified Make: Keysight Technologies
Model: Keysight N9344C E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: Keysight N9344C | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
₹71,514
Closing Date
22 Oct 2018, 6:00 pmClosed
spectrum analyzers vector network analyzers ( PAC Only ) Spectrum Analyzers Vector Network Analyzers ( 3 ) ( Under PAC ) Make keysighttechnologies Model keysightn9344c Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers
Two port vector network analyzers(with spectrum analyser)
Two port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal
delta * Trigger Free run
video
External * Display TFT Colour display with provision for three traces * Interface USB
LAN * 1/5 Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 100 kHz to 18 GHz 9 kHz to 3 GHz
9 kHz to 7 GHz
9 kHz to 13 GHz
100 kHz to 18 GHz
9 kHz to 26.5 GHz
9 kHz to 40 GHz
9 kHz to 6 GHz
NA Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * Frequency counter Resolution(minimum) (Hz) 1 * Frequency Span 100Hz to 18 GHz * Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 2.5mS to 1000S * Sweep time @span = 0 Hz 100 micro S to 20 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=2 * Average noise level dis played(@300HzRBW
10 Hz VBW) NA * Average noise level dis played(@100HzRBW
1 Hz VBW) <= -125dBm for 3GHz to 13 GHz * 2/5 Average noise level dis played(@300HzRBW
1 Hz VBW) NA * Measurement features C/N ratio
AM%
time domain power measurement
channel power measurement
Phase noise measurement
TOI (THIRD ORDER INTERC EPT)
OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer NA * Frequency Resolution (CW ON) (Hz) NA * Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open
short
load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels - * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay - * 3/5 measurement OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
50Hz
Rechargeable battery 230 +- 10 VAC
Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 15 * capacity of rechargeable battery (millAh) 5300 * Suitable charger adaptor provided Yes * WARRANTY Warranty 3 1
2
3
4
5 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply - * GENERIC Other features - * CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest yes * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH yes * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number - * 4/5 and date for the specification test Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biswajeet Tripathy 756025
Integrated Test Range Ministry of Defence DRDO
Chandipur 3 30
688801
GEM/2018/B/97513
spectrum analyzers vector network analyzers
30 days
Odisha; Baleshwar
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| spectrum analyzers vector network analyzers ( PAC Only ) Spectrum Analyzers Vector Network Analyzers ( 3 ) ( Under PAC ) Make keysighttechnologies Model keysightn9344c Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers | - | - | - |
| Two port vector network analyzers(with spectrum analyser) | - | - | - |
| Two port vector network analyzers (without spectrum analyser) GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal | - | - | - |
| delta * Trigger Free run | - | - | - |
| video | - | - | - |
| External * Display TFT Colour display with provision for three traces * Interface USB | - | - | - |
| LAN * 1/5 Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 100 kHz to 18 GHz 9 kHz to 3 GHz | - | - | - |
| 9 kHz to 7 GHz | - | - | - |
| 9 kHz to 13 GHz | - | - | - |
| 100 kHz to 18 GHz | - | - | - |
| 9 kHz to 26.5 GHz | - | - | - |
| 9 kHz to 40 GHz | - | - | - |
| 9 kHz to 6 GHz | - | - | - |
| NA Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * Frequency counter Resolution(minimum) (Hz) 1 * Frequency Span 100Hz to 18 GHz * Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 2.5mS to 1000S * Sweep time @span = 0 Hz 100 micro S to 20 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=2 * Average noise level dis played(@300HzRBW | - | - | - |
| 10 Hz VBW) NA * Average noise level dis played(@100HzRBW | - | - | - |
| 1 Hz VBW) <= -125dBm for 3GHz to 13 GHz * 2/5 Average noise level dis played(@300HzRBW | - | - | - |
| 1 Hz VBW) NA * Measurement features C/N ratio | - | - | - |
| AM% | - | - | - |
| time domain power measurement | - | - | - |
| channel power measurement | - | - | - |
| Phase noise measurement | - | - | - |
| TOI (THIRD ORDER INTERC EPT) | - | - | - |
| OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer NA * Frequency Resolution (CW ON) (Hz) NA * Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open | - | - | - |
| short | - | - | - |
| load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels - * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay - * 3/5 measurement OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC | - | - | - |
| 50Hz | - | - | - |
| Rechargeable battery 230 +- 10 VAC | - | - | - |
| Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 15 * capacity of rechargeable battery (millAh) 5300 * Suitable charger adaptor provided Yes * WARRANTY Warranty 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply - * GENERIC Other features - * CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest yes * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest yes * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH yes * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number - * 4/5 and date for the specification test Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Biswajeet Tripathy 756025 | - | - | - |
| Integrated Test Range Ministry of Defence DRDO | - | - | - |
| Chandipur 3 30 | - | - | - |
₹71,514
22 Oct 2018
3 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_688801.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .