Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.8 L
EMD Value
₹4,900
Closing Date
17 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineering UPSIC KANPUR
Executive Engineering UPSIC KANPUR
Construction work of Toilets at Dayanand Girls Inter College Alakanda Enclave Chakeri Maharajpur Kanpur Nagar
2026_MSME_1105186_4
1823/EE4/25-26
Open Tender
Civil Works
Percentage
90 days
KANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Executive Engineering UPSIC KANPUR
₹4,900
9 Jan 2026
9 Jan 2026
19 Jan 2026
9 Jan 2026
17 Jan 2026
9 Jan 2026
Brick work with common burnt clay (Non Modular) Bricks of class-150 in Superstructure above plinth level up to floor v level in all shape and sizes: cement mortar 1:4 (Coarse sand) DSR 6.4.1
Structural steel work in single section fixed with or without connecting plate including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete. PWD/DSR10.2
Provinding and fixing 1st quality ceramic glazed wall tiles conforming to is:15622 (thickness to be specified by the manfacturee) of approved make,in all colour shades except burgundy,bottle black of any size as approved by engineer in charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1:3 and jointing with grey slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.PWD/DSR 8.31
Provinding and fixing 1st quality ceramic glazed floor tiles of size 300 x 300 mm conforming to is:15622 (thickness to be specified by the manfacturee) of approved make,in all colour shades except white,ivory,grey fume red brown laidon 20 mm thick bed of cement mortar 1:4 and jointing with grey slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.PWD/DSR 11.38
Painting 1st coat over priming coat (but excluding cost of priming coat) on steel and other metal surface upto 10 cm width or girth or small articles not exceeding 0.10 sqm in area with superior synthetic enamel such as luxol 3,hi gloss apcolite superlac dulex specified brushing to give and even shade and including the cleaning the surfacw of all dirt dust and other foreign matter sand papering and scrapping including cost of all materials labour,tools and plants etc.required for proper completion of work. PWD/DSR 13.62.1
25mm nominal outer dia pipe
40 mm nominal outer dia pipe
20mm Nominal outer dia pipes
110mm dia
160 mm dia
110mm dia
Providing and fixing of 110x110mm Nahani trap Prince, supreme, Vectus or equivalant make class ISI marked U-PVC, SWR .
Providing and fixingwash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste ofstandard pattern, includingpainting of fittings and brackets cutting and makinggood thewalls wherever require: White Vitreous China Wash basin size 450X 300 mm with a pair of 15 mmC.P.DSR 17.7.7
32mm dia
25 mm nominal bore
15 mm nominal bore
Orissa pattern W.C.pan of size 580 x 440 mm 17.13.2
Provinding and fixing P.V.C Low level flushing cisten with manually controlled device (Handle lever ) conforming to is 7231 with all fitting and fixtures complete. 10 litre capacity white DSR 17.19.1
Providing and fixing PTMT bib cock of approved quality & Colour (DSR 18.54.2) 15 mm nominal bore 122 mm long, weiting not less then 99 gms
Provinding and fixing c.p brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal size DSR/PWD 18.53.1
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 450x450 mm (DSR : 17.32.2)
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter (DSR : 19.21.1)
Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineerin- Charge. (DSR : 9.119)
Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer's specification & drawing. (DSR : 9.120)
100mm nominal dia pipe Sewar
S/F of 4x2.5 feet size granite stone at site including writing painting with graving and cartage up to site complete/
Group - A
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Upto 450 mm sweep
300mm EXHAUST FAN
6 way , Double door
Supply fixing of 5A to 32 Amp MCB
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but with charcoal or coke and salt) as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_2039251.xls
BOQ • 0.33 MB
TermsandConditionTenderCivilWorks.pdf
Tender Documents • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .