| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹37.4 L Quoted ₹37.9 L | L1 | Accepted-AOC TENDER FOUND LOWEST, HENCE TENDER ACCEPTED |
| 2 | L2₹44.5 LRejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | ₹44.5 L | L2 | Rejected-AOC NOT LOWEST |
| 3 | Rejected-Technical | - | - | Rejected-Technical The contractor does not have c(i) category hence bid is technically rejected. |
| Sl No | Description | Qty | Unit | Universal refrigeration and Engineering Company L1 | THE DECAN ENGINEERING AND REFRIGERATION COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down existing unserviceable point wiring of any type/ size of light/fan/socket/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and as directed. | 928 | Point | 5 ₹4,640 | 28 ₹25,984 |
| 2.00 | Taking down existing unserviceable light fittings,security light fittings,bulk head fittings,fall ceiling light fittings etc. from any height of building complete all as specified and as directed. | 323 | Each | 10 ₹3,230 | 28 ₹9,044 |
| 3.00 | Taking down existing unserviceable MCB's/MCCB's/Distribution boards any capacity complete all as specified and as directed. | 134 | Each | 5 ₹670 | 28 ₹3,752 |
| 4.00 | Taking down earthing material complete plate and pipe etc from 2.25 mtrs depth complete all as specified and as directed. | 5 | Job | 100 ₹500 | 100 ₹500 |
| 5.00 | M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded, copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade, ISI marked, 20 mm bore with conduit accessories concealed in wall /floor and fixed on ceiling/roof/truss/columns etc, including provision of fabricated branded pressed steel terminal box of suitable sizes with 1.6mm thickness duly painted inner and outer side by anti corrosive paint for housing the switches, sockets, fan regulators etc and covered with 3mm thick plastic laminated sheet cover with cadmium plated screw, cup washer etc. complete concealed in walls and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one light point controlled by one switch complete all as specified and as directed.
Note (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
(2) The cost of cutting of chases of required width and depth for concealled conduit incl plastering, making good to disturbed surface, painting two coats to match the existing wall colour is deemed to be included in the quoted rate by the contractor. | 40 | Point | 650 ₹26,000 | 750 ₹30,000 |
| 6.00 | All as per Sl item No 5 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator complete all as specified and as directed | 20 | Point | 650 ₹13,000 | 750 ₹15,000 |
| 7.00 | All as per Sl item No 5 above, but for One 5 Amps socket outlet point on the independent board complete all as specified and as directed | 30 | Point | 650 ₹19,500 | 250 ₹7,500 |
| 8.00 | All as per Sl item No 5 above, but for One 5 Amps socket outlet point on the same board complete all as specified and as directed | 20 | Point | 115 ₹2,300 | 750 ₹15,000 |
| 9.00 | All as per Sl item No. 5 here in before, but for One Bell point controlled by one, bell push complete all as specified and as directed | 2 | Point | 650 ₹1,300 | 750 ₹1,500 |
| 10.00 | All as per Sl item No 5 above but for One light point controlled by two way switch complete all as specified and as directed | 1 | Point | 690 ₹690 | 750 ₹750 |
Updated dates
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
6 Apr 2026, 6:00 pmClosed
RAMESH CHANDRA MEENA
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD PIN - 500003
REPAIR REPLACEMENT TO INTERNAL ELECTRIFICATION AND ITS CONNECTED WORKS OF OTM AND MD ACCNS AT MH MDC AREA AND REPAIR REPLACEMENT OF COOLING APPLIANCES AT VARIOUS OTM ACCNS OF TASA UNDER AGE E M (SOUTH) OF GE (SOUTH) SECUNDERABAD.
2026_MES_755185_1
GE(S)/SEC/TOKEN-114 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
GE SOUTH, MUDFORT, SECUNDERABAD
For Enlisted contractors class D and above category b (i) and c (i) for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABAD
₹98,000
Yes
13 Jun 2026
5 Mar 2026
8 Apr 2026
5 Mar 2026
6 Apr 2026
19 Mar 2026
5 Mar 2026 - 18 Mar 2026
Taking down existing unserviceable point wiring of any type/ size of light/fan/socket/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area complete all as specified and as directed.
Taking down existing unserviceable light fittings,security light fittings,bulk head fittings,fall ceiling light fittings etc. from any height of building complete all as specified and as directed.
Taking down existing unserviceable MCB's/MCCB's/Distribution boards any capacity complete all as specified and as directed.
Taking down earthing material complete plate and pipe etc from 2.25 mtrs depth complete all as specified and as directed.
All as per Sl item No 5 above but for One ceiling fan/exhaust fan point controlled by one switch through regulator complete all as specified and as directed
All as per Sl item No 5 above, but for One 5 Amps socket outlet point on the independent board complete all as specified and as directed
All as per Sl item No 5 above, but for One 5 Amps socket outlet point on the same board complete all as specified and as directed
All as per Sl item No. 5 here in before, but for One Bell point controlled by one, bell push complete all as specified and as directed
All as per Sl item No 5 above but for One light point controlled by two way switch complete all as specified and as directed
M & L for Point wiring complete with two runs of 1.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets, fan regulators etc and provn of 1.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one light point controlled by one switch. Note (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
All as per Sl item No 13 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed
All as per Sl item No. 13 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular board complete all as specified and as directed.
All as per Sl item No. 13 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board.
All as per Sl item No. 13 here in before, but for One Bell point controlled by one, one way modular switch 5 amps, SP complete all as specified and as directed
All as per Sl item No. 13 here in before, but for One light point controlled by two 2 - w a y modular s w i t c h 5 amps, SP complete all as specified and as directed
M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 15 Amps socket out point independent boardcomplete all as specified and as directed Note (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
M & L for Point wiring complete with two runs of 2.5 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 2.5 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc. complete all as specified and as directed for one 15 Amps socket out point same board Note (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
M & L for Point wiring complete with two runs of 4 Sq mm (for Phase and neutral) PVC insulated unsheathed multi stranded ,copper conductor FRLS cable of 1100V grade drawn through and including new non metallic rigid PVC conduit medium grade , ISI marked , 20 mm bore with conduit accessories for Modular surface wiring mount on wall or fixed on ceiling/roof/truss/columns etc, including provision of branded modular PVC terminal box of suitable sizes with 1.6mm thickness including modular cover frame & box of suitable size for modular switch boards any size of modules for housing modular switches, sockets,etc and provn of 4 Sqmm PVC insulated unsheathed copper conductor cable of green colour to common earth dolly etc for one 15 Amps socket out point independent board complete all as specified and as directed Note (1) The wiring shall be done in proper color coding using red, yellow, blue for phases, black for neutral and green for earth.
All as per Sl item No 22 above but for One ceiling fan/exhaust fan point controlled by one switch through modular regulator complete all as specified and as directed
All as per Sl item No. 22 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent modular board complete all as specified and as directed
All as per Sl item No. 22 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same modular board complete all as specified and as directed
All as per Sl item No. 22 here in before, but for One Bell point controlled by one, one way modular switch 5 amps, SP complete all as specified and as directed
All as per Sl item No. 22 here in before, but for One light point controlled by two 2 - w a y modular s w i t c h 5 amps, SP complete all as specified and as directed
S & F switch piano single pole flush type 6 amps, 230 volts. complete all as specified and as directed
S & F switch piano single pole flush type 16 amps, 230 volts.complete all as specified and as directed
S & F single pole Modular switch 1 way 6 Amps, 1 Module Note: (i)All light/fan switches shall be symbol embossed (light/fan) type complete all as specified and as directed (ii) All switches for sockets shall be LED indicator type.
S & F single pole Modular switch 1 way 16 Amps, 1 Module with red LED indicator complete all as specified and as directed
S & F Switch piano two way flush type 6 Amps capacity 230 volts complete all as specified and as directed
S & F Modular switch 2 way 6 Amps, 1 Module complete all as specified and as directed
S & F bell push 5 A flush type complete all as specified and as directed
S & F Modular Bell Push 6A, 1 Module with bell symbol complete all as specified and as directed
S & F Socket modular type multipurpose 2/3 Pin, 6 amps, 230 volts 2 Module complete all as specified and as directed.
S & F Socket modular type multipurpose 3/6 Pin, 16 amps, 230 volts 2 Module complete all as specified and as directed.
S & F Socket flush type multipurpose 2 in 1, 3 Pin, 6 amps, 230 volts complete all as specified and as directed
S & F Socket flush type multipurpose 2 in 1, 3/6 Pin, 16 amps, 230 volts complete all as specified and as directed
S & F Switch socket combination flush type multipurpose 2/3 pin 6 amps 2 in 1 230 Volts without point wiring complete all as specified and as directed
S & F Switch socket combination 5 in 1 multipurpose 3/5 pin 16 amps flush typewith without point wiring complete all as specified and as directed
S & F Modular ceiling fan regulator stepped socket size, 2 module suitable to work on 230 volts complete all as specified and as directed
S&F Modular frames of any size, capacity of moldule configuration suitable existing switch boards up to 24 modules white colour 6/16Amps complete all as specified and as directed
S & F hot and cold PVC connection pipe 60CM length 120 degrees centigrade temperature suitable for geysers 15/25/50 ltrs complete all as specified and as directed.
S & F Electronic type fan regulator socket type single module, suitable to work on 230 volts all as specified.
S&F calling bell ding dong working on 230 volts AC with different ring tones optional complete all as specified and as directed.
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed.
S & F lamp holder any angle suitable for LED Bulbs of capacity 7/15 watts insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and as directed
S & F 20 W surface / wall mounted LED batten light fitting aluminium extrusion input voltage range 250 V, input frequency 50 Hz, efficacy not less than 120 Lumen/Watt, rated llife 50000 Burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed. Make: Crompton CCS-100-20-65-HSL2-DP-NWH/ PHILIPS BN308CLED20S-6500L120PSUWH / WIPRO LL31-251-XXX-65AL5/Havells ENDURALINEARPROBS20WLED865PCSSIND/Bajaj-BCLAB20WCWLEDXT
S & F 10 W surface / wall mounted 2 feet LED batten light fitting input voltage range 250 V, input frequency 50Hz, efficacy not less than 100 Lumen/Watt rated life 25000 burning hours including 2 nos PVC Connector blocks electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and as directed. Make:Crompton CCS-103-10-65-SL-DP-NWH/ Havells LHEXAZP7PN1W010 / PHILIPS BN021LED12S 6500K PSU GR / WIPROLL20-111-XXX-65NE3 /Bajaj-BCLAB10WLEDCWLED
S & F LED light fitting 10W bulkhead luminaires, efficacy not less than 100 lm/w, rated life 25000 burning hours including LED light driver holder connecting up with three core flexible copper conductor cable IP 65 out door type metal body of suitable size complete all as specified and as directed Make: Crompton CIS-306-10-57-SL-DP-NBK/ PHILIPS WT202W LED10S CW PSU S3 PC/ HAVELLS HEXAFT10WLED857SSYMBOPC /WIPRO LW07-141-XXX-57-G1/Bajaj-BIBWP10W LED
S & F ing LED security light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in complete all as specified and as directed. Make:Crompton CRP-409-70-57-SL-GL-NSG/ PHILIPS-URBAN EDGE-BRP501LED078CWR5CPSUS1V1 / HAVELLS-ENDURA SUNDOWN SL70WLED765PASYBOTG /WIPRO-LR09-781-XXX-57-XX/Bajaj-ZELAP86LWHPOTGSDJ72W/GOLDMEDAL-SL-70WQV1
S & F ing LED security light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant,efficacy not less than 120 lm/Watts,rated life 50000 burning hours complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection with wall mounting bracket arm OD 35 mm to 42 mm including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete suitable for pop/grid false ceiling in complete all as specified and as directed. Make:Crompton TRP-409-45-57-SL-GL-NSG / PHILIPS BRP331LED48CWR5NPCPSUS1V1 / HAVELLS ENDURASUNDOWNSL45WLED765PASYBOPC /WIPRO LR22-501-XXX-57-XX/Bajaj-VISTAP45LWHPOPCSD
S & F 15 Watt LED Bulb minimum 2 star rated efficacy not less than 100 Lumen/watts,rated life 25000 burning hours with lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings including taking down the old unserviceable complete all as specified and as directed.
S & F LED Bulb 7 watts mimimum 2 star rated efficacy not less than 100 Lumen/watts,rated life 25000 burning hours with lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings including taking down the old unserviceable complete all as specified and as directed.
S & F recess mounting LED down light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow,efficacy 120 lumen/watts rated life 50000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make:Crompton: LCTLRP-36-FO-CDL / PHILIPS RC308LED36S6500 / HAVELLS VENUSEXL2X2PLR36WLED865SWH /WIPRO-CRCO10R036HE57G4/Bajaj-BZRSQL43LXEWHODSD
S & F surface mounting light fitting with new LED down light fitting 2' x 2' of capacity 36 Watts powder coated white CRCA full glow suitable for True ceiling rated life 50,000 burning hours including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make: HAVELLS PLANOSUR2X2PLS36WLED857G2S / PHILIPS SM367 LED36S-6500 G6 L54W54 PSU OD/ WIPRO CRCO10R036HE57G4+Frame/Bajaj-BZSSQL43LXEWHODSD
S & F recess mounting LED round down light fitting of capacity 15 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make:Crompton:LSCRM-15-CDL/Havells VIBEFLRDDLR15WLED857S/Philips DN296B LED 20S-6500 PSU WH S2/Bajaj-BGSLO15LLEDWHVC/Gold Medal-GL91327CD/Wipro-LD13R-171-XXX-57-XX
S & F recess mounting LED round down light fitting of capacity 12 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make:Crompton:LSCRM-12-CDL/Havells VIBEFLRDDLR12WLED857S/Philips DN296B LED 12S-6500 PSU WH /WiproLD13R-151-XXX-57-XX/Bajaj-BGSLO12LLEDWHVC
S & F recess mounting LED round down light fitting of capacity 10 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make:Crompton:LSCRM-12-CDL/Havells:INTEGRANEODLR10WLED830S/Philips DN296B LED 10S-6500 PSU WH /WiproLD13R-151-XXX-57-XX/Bajaj-BGSLO12LLEDWHVC
S & F recess mounting LED round down light fitting of capacity 6 Watts powder coated white glow,efficacy 100 lumen/watts rated life 25000 burning hours suitable for false ceiling pop/grid ceiling including making electrical connection from ceiling rose to light fitting complete all as specified and as directed . Make:Crompton:LSCRM-6W-CDL/Havells VIBEFLRDDLR6WLED857S/Philips DN295B LED 8S-6500 PSU WH/Wipro-LD13R-670-XX-57-XX /Bajaj-BGSLO6LLEDWHVC
S&F in replacement of LED Bulb not less than 0.5Watts Red and Green Colour complete all as specified and as directed
S & F surface mounted spot/focus/Track light fixture,adjustable light beam angle ,aluminium housing, including making electrical connection from ceiling rose to light fitting,suitable metal track of length minimum 12 inches fixing on RCC ceiling/roof/ Structure with necessary fixing arrangements complete all as specified and as directed. MakeM/s Shakti Cat Part No.SZSTCMX020/M/s Luker Cat Part No.LSPT24SN/M/s Fortune Artt Cat Part No.TSR20/8/M/s Philips CatPart No.ST033TLED17SWW/NW/CW20W or equivalent
Decorative wall light fitting and fixture including making electrical connection from ceiling rose to light fitting complete all as specified and as directed. Make:WIPRO-WL-WALLY-B22/Havells-FlorentineWL1LSB22SS-LHFOAJE1TZ1I060/Bajaj-BJLF4 7W TO 15 W
S & F Electric water heater, storage type,vertical, single phase, electric operated, 50Hz, steel body heating element up to 2 KW capacity 25 Ltrs, BEE 5 star rated innner tank as per OEM specification with minimum 2 years warranty on over all product (inner tank ,heating element & thermostat) complete with all accessories such as safety valve, thermostate, NRV, connection piece, FRLS multistranded copper conductor cable 3 core PVC insulated, plug top 3 pin 15 Amp , 15 mm dia, brass coupler, flexible pipe suitable to withstand upto 120 °C for hot and cold water, Anchor fastener- 04 Nos of suitable size etc. including marking of MES number on water heater by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on geyser complete all as specified and as directed Make:Crompton VERSA 25L / HAVELLS FABIA GHWAFATWB025 / Gold Medal SWMS01025VWH / Bajaj SPECTRUM15096625L/Luker-LPST25
M & L for steel water tubing medium grade 15 mm dia including all fittings laid on wall complete all as specified and as directed.
S & F Bib tap 15mm dia chromium plated copper alloy material complete all as specified and as directed.
S & F chromium plated copper alloy material ball/stop/gate valve 15mm dia complete all as specified and as directed.
S&F rgid PVC conduit of dia 20 mm dia ISI marked complete all as specified and as directed.
S & F ing ceiling fans complete with blades,copper winding, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery not less than 210 CFM with service value more than equal to (≥) 6.00, BEE Five star rated with brushless direct current motor (BLDC) white colour and marking of MES number on ceiling fan by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on fan complete all as specified and as directed. Make:Gold Medal cat part No.SCFS 500748/Bajaj Cat part No:ENERGOS 28/ Crompton Cat part No:ENERGION RIVIRA/Havells Cat part No:PRO 28BLDC/Luker Cat part No:ECO28NEOBLDC Regulator 230cmm/Orient Cat Part No:Hector 500-230CMM/Polar Cat part No:PS-32
S & F exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm sweep including marking of MES number on ceiling fan by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on fan complete all as specified and as directed.Make:Havells Cat part No:Vetil Air DX HS/Gold Medal EFS850310 AIR MAXX/Crompton VENTILUS250MM/Bajaj-Maxima neo/Luker cat part No:Viento LX10
S & F exhaust fan, metal body AC single Phase 230V of size 225 mm sweep,RPM 1200 with, copper winding,blades,rag-bolts, and frame and louvers complete including making suitable size hole in wall for fixing of fan with marking of MES number on ceiling fan by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on fan complete all as specified and as directed. Make:M/s Luker TUULI Metal/M/s Bjaj 70079MAXAIR 225 MM DOM EX FAN/M/s Orient HIGHAIR 230MM 550CMH 1350RPM/M/s Crompton FLUX AIR225MM1380RPM800CMM
S & F exhaust fan, metal body AC single Phase 230V of size 300 mm sweep,RPM 1200 with, copper winding,blades,rag-bolts, and frame and louvers complete including making suitable size hole in wall for fixing of fan with marking of MES number on ceiling fan by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on fan complete all as specified and as directed. Make: Havells Cat part No:Ventil air DSB /Gold Medal EFS851012 HAVAC PLUS /Crompton drift air plus300mm/Bajaj-Supreme plus/Luker cat part No:TuuliLME12
S & F exhaust fan, metal body AC single Phase 230V of size 450 mm sweep,RPM 1200 with, copper winding,blades,rag-bolts, and frame and louvers complete including making suitable size hole in wall for fixing of fan with marking of MES number on ceiling fan by stamping with ink print of lettering frame size Length 20cm width 2.5 cm " at least two sides on fan complete all as specified and as directed. Make: Havells Cat part No:Turbo Force Ex Neo 1PH(1400RPM) /Crompton:EXHD450-4-1-1400RPM-350W /Bajaj-70064 Supreme plus 1400RPM
S & F PVC sleeve tail piece for fixing exhaust fan on the wall complete all as specified and as directed.
S & F MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed
S & F MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KA complete all as specified and as directed
S & F MCB TPN,63 Amps, rupturing capacity 10 KA 415 volts suitable for fixing in existing DB of any capacity complete all as specified and as directed .
S & F in replacement sheet metal enclosure MCB DB SPN 4 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed .
S & F in replacement sheet metal enclosure MCB DB SPN 8 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed .
S & F in replacement sheet metal enclosure MCB DB SPN 12 way double door with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed .
S & F in replacement of TPN DB 4 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed.
S & F in replacement of TPN DB 8 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed.
S & F in replacement of TPN DB 12 way double door horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed.
S & F in replacement of TPN DB 4 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed .
S & F in replacement of TPN DB 8 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed .
S & F in replacement of TPN DB 12 way double door vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed .
S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) complete all as specified and as directed.
S&F MCCB 415V, 16KA, 100 amps 4 Pole, thermal magnetic release fixedtype,short circuit and over load protection suitable for DB including removing the existing unserviceable one complete all as specified and as directed.
S&F MCCB 415V, 16KA, 63 amps 4 Pole thermal magnetic release fixedtype,short circuit and over load protection suitable for DB including removing the existing unserviceable one all as specified and as directed.
M & L for repairs to copper inner tank, like denting, soldering, brazing, leak testing and reassembling of any Ltrs capacity water heater (Geyser) complete all as specified and as directed
Supply and replace Geyser element 2000 watts /1500watts of any type (Circular OR tringular) or as per site requirement complete all as specified and as directed.
Supply and replace Thermostat suitable for existing geyserof 15/25/50 litres of any make complete all as specified and as directed.
Supply and replace Indicator bulb 230 V suitable for any make and colour complete all as specified and as directed.
S &F Bib taps chromium plated with crutch or butter fly handle 15 mm dia screwed for iron pipe or for brass ferrule and fixed including cutting of GI pipe complete all as specified and as directed.
S & F GI pipe 15 mm dia medium grade for geysers raising main & down comer connections includning complete fittings and accessories and earthings complete all as specified and as directed.
S & F gate valve 15 mm dia complete all as specified and as directed.
S & F ing in replacement inner tank, ISI marked made of stainless steel suitable for 25 Litters capacity geyser complete all as specified and as directed.
S & F ing PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire complete all as specified and as directed.
Supply and replace Plug top 5 Amps 3 pin 250 Volts complete all as specified and as directed.
S & F Plug Top 3 pin 15 Amps for storage geyser including removal of existing plug top complete all as specified and as directed. .
Supply and replace Industrial type Plug top 3 pin, 20 Amps suitable for industrial socket for storage geyser including taking down old UNSV / rusted complete all as specified.
Taking down ceiling/exhaust fans of any type and size after disconnecting from existing ceiling rose to connector and clamp hooks and transportation to MES Complaint Cell, cleaning externally, dismantling and examining the rotor, startor, bearings, bushes, etc; for serviceability and repairing/replacing the defective parts subsequently oiling, greasing, assembling, testing for proper functioning, checking for safety security and proper locking, transporting back to building/site from work shop, hanging at its original position and connecting electrical connections,complete servicing, testing for noise free smooth running etc complete all as specified and as directed.
Taking down old unserviceable rusted ceiling/exhaust fan blades and providing new ceiling fan blades & screws as appropriate shape and size suitable for ceiling fans any make and size 1200mm/1400mm sweep complete all as specified and as directed.
S & F in replacement new metallic clamps (minium 03 mm thick), rubber bush, nut bolt, washer and cotter pin and for various types of ceiling fans to complete the repair work complete all as specified and as directed.
M & L for painting of ceiling fans/exhuast fans along with blades of any make/model of size upto 1400mm sweep , cleaning thoroughly with sand paper,remove residue, three coats of supper enameled white colour paint over a coat of primer,dried in woven, printing MES No in 20mm letter size stamping template with black paint etc complete all as specified and as directed . Note :-The rate quoted deemed to be inclusive of hiring of painting equipment, taking down and shifting of celing fans at users site.
Taking out defective/worn out Ball Bearing of any make and S & F new bearing suitable for various makes of ceiling fans of size 1200 to 1400mm sweep complete all as specified and as directed.
Taking out defective capacitor and S & F new capacitor of 2.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed.
Taking out defective capacitor and S & F new capacitor of 3.5 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed.
Taking out defective capacitor and S & F new capacitor of 4.0 mfd of approved make with holding clamp for various makes of ceiling fans complete all as specified and as directed.
Taking out worn out Gun metal bush and S & F new Gun metal bush for various makes of ceiling fans of size 1200mm/1400mm sweep. (as per sample) complete all as specified and as directed.
Taking down Canopy S & F new canopy as approved suitable for Ceiling Fans of 1200/1400 mm sweep of any make/colour complete all as specified and as directed.
S&F in replacement of ceiling fan downrod of required height including drilling of holes and threads of dia 15 mm as per the site requirement as directed at site complete all as specified and as directed.
S & F in replacement of unserviceable gang box wtih modular Gang box 5 Amps modular switch socket complete all as specified and as directed.
S & F in replacement of unserviceable gang box wtih modular Gang box 15 Amps modular switch socket complete all as specified and as directed.
Supply and replace PVC Dummy sheets circular type of 4" complete all as specified and as directed.
Supply and replace PVC Dummy sheets circular type of 6" complete all as specified and as directed.
M & L for Cutting chases required width and depth goove cutting on brick wall/stone masonry wall for conceald the existing surface submian wiring , pinning , making good to facings where required and pointing in cement mortar 1:3 to ends or edges incl plastering ,painting two coats of distemper to match the existing wall colour complete of all as specified and as directed .
M & L for Cutting chases required width and depth goove cutting on brick wall/stone masonry wall for conceald the existing surface 1.5 Sq.mm / 2.5 Sq.mm point wiring , pinning , making good to facings where required and pointing in cement mortar 1:3 to ends or edges incl plastering ,painting two coats of distemper to match the existing wall colour complete of all as specified and as directed .
M & L for replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and as directed.
S&F rigid PVC conduit of 20/30 mm dia ISI marked complete all as specified and as dierected.
S&F LED Drivers suitable for any type/size of LED lights up to 40 watts complete all as specified and as directed..
S&F Surge protection device suitable for any type/size of LED lights up to 40 watts complete all as specified and as directed.
S&F in replacement of louvers duly fabrcated with aluminium sheet metal frame suitable for 250 to 450 mm sweep Exhaust fans complete all as specified and as directed. Note: The rated quoted deemed to be inclusive of required T&P for any height of building for fixing of louvers.
Taking down and servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors, fan motor etc,(Out door unit) with vacuum cleaner OR cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc., changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition after necessary servicing/ repair/ replacement of defective spares as required and refixing the same in existing position complete all specified and as directed .
S&F Capillary tube including filter / stainer complete for Split Type AC of 1.5/2 Ton Type AC and taking out the old unserviceable one complete all as specified and as directed.
Supply and replacement of Outdoor unit fan motor of existing capacity and size for 1.5 Ton / 2.0 Ton capacity split type Air conditioner of any make and model complete all as specified and as directed. Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of Running capacitor 36 / 45 MFD complete all as specified and as directed.
Supply and replacement of Running capacitor 50 / 50+6 MFD complete all as specified and as directed.
Supply and repalcement of Starting capacitor 60-100 MFD complete all as specified and as directed.
Supply and repalcement of condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for Split Type AC 1.5 Ton complete all as specified and as directed.
Supply and repalcement of condensercoil/Evaporator coil made out of 25 SWG copper tubing having 30/34G Aluminum Fins per cm length for Split Type AC 2.0 Ton complete all as specified and as directed.
M & L for complete rewiring of Outdoor Split AC complete all as specified and as directed.
S & F ing in replacement of Outdoor Unit stand including removing the old rusted stand for fixing on wall complete accesories all as specified as directed.
Supply and replacement of remote control unit for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed.
M& L for repair of PCB circuit board of disconnecting of electrical connection of from split AC suitable for inverter or non inverter and taking out the unserviceable PCB and repair ,any type and any make 1.5 Ton, 2 Ton capacity complete all as specified and as directed.
M & L for replacement of new PCB of Indoor Unit of Spilt Type AC of Existing capacity incl taking down complete all as specified and as directed.
Supply and replacement of copper capillary tube including filter/stainer complete all as specified and as directed.
Supply and replacement of brass service valve and flurry nut complete all as specified and as directed.
Supply and replacement of indoor blower motor with fan for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed.
Supply and replacement of fan blade of existing size for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed.
Supply and replacement of Oscillator motor including blade for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed.
S&F Air Filter for Split type AC and taking out the old unserviceable one complete all as specified and as directed.
Supply and replacement of Room sensor with coil for Split type Air Conditioner of 1.5 Ton/2.0 Ton capacity of any type and make complete all as specified and as directed.
Supply and replacement of Split Type AC front side PVC grills of suitable size/make as per sample complete all as specified and as directed.
S & F ing in replacement of insulation kit of copper tubing refrigerent pipe of suction and discharge including sleeves for split AC 1.5 / 2.0 Ton of size 1/4", 1/2",3/4" & 5/8" ,complete taking down of existing insulation complete all as specified and as directed.
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and as directed. Note: (a) The rate quoted Deemed to be inclusive of transportation of AC where the location under Area of responsibility of AGE E/M (S) Secunderabad.
M & L for Leak Test, leak detection and refitting the same including brazing in the entire system , testing of Split type AC upto 2.0 Ton complete all as specified and as directed.
Supply and replacement of 1 Pole contactors of Indoor Unit for Split Type AC and removing the old Unserviceable one complete all as specified and as directed..
Supply and replacement of Display Board of Split Type AC Indoor unit and removing the existing one complete all as specified and as directed.
M & L for complete wiring kit for Split Type AC of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing complete all as specified and as directed.
S&F PVC Drain pipe 25mm for rectifying water leakage from AC Units complete all as specified and as directed.
S & F ing in replacement of Indoor Unit comprising of evaporator tube with copper coil set,indoor blower motor set assembly, ocillators, sensors, louvers & Complete set suitable for 1.5 Ton split AC to match with the make of existing outdoor unit, preferably of same make and model including making electrical connection and suitable connecting copper pipes complete all as specified and as directed. at site. Note : Existing taking down unserviceable indoor unit shall be transported and deposited at MES store yard.
S & F ing in replacement of outdoor Unit comprising of compressor,condenser copper coil set with fins assembly,blower motor with fan assebly set with canopy Complete set out door unit suitable for 1.5 Ton split AC indoor unit complete to match with the make,type, capcity, model of existing indoor unit, preferably of same make and model including making electrical connection and connecting copper pipes complete all as specified and as directed. at site. Note : Existing taking down unserviceable outdoor unit shall be transported and deposited at MES store yard.
M & L for Water leakage checking of Split AC and rectiy the same at site complete including drilling of hole in any type/height of wall/wood panelling with dimond core cutting machine including fixing of PVC flexible pipes, PVC conduit etc.to match the existing surface neat and clean with paint/white wash complete all as specified and as directed. Note:The rate quoted deemed to be inclusive of hiring of diamond core cutting machine and transportation of T&P.
S&F gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and as directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and as directed."
Dismantling of existing repairable Non-Inverter/inverter Refrigerators of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop for carrying out repairs and renewal/replacement of parts, reassembling and transporting back to the site including installation of the same on the same location and making electric connection etc, complete all as specified and as directed. .
M & L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Refrigerator of any capacity upto 320 ltr complete including refrigerant gas and charging all as specified. Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH. Note : (1) As per the existing type & make of the Refrigerator . (2) Cost of charging refrigerant gas will be measured and paid under respect item of work of this Schedule.
M & L for replacement of old over load protector with new over load protector for Refrigerator of any Capacity complete all as specified and as directed..
M & L for replacement of old over relay with new over load relay for Refrigerator of any Capacity complete all as specified and as directed.
S&F Thermostat set complete for Refrigerator of any capcity including removing the old unserviceable complete all as specified and as directed.
S&F Copper Capillary tube including filter / stainer with necessary brazing ,Leak testing for Refrigerator of any capacity complete all as specified and as directed.
Supply and charging of refrigerant gas including testing of refrigerator of capacity upto 320 ltrs all as specified and as directed. Note :- There shall not be any duplication of gas charging for the entire period of contract.
M & L for Leak test complete with leak detection and refitting including brazing / welding the same in the entire system , testing of refrigerator of capacity upto 320 ltrs complete all as specified and as directed.
S&F Magnetic door gasket for Refrigerator including removing the old unserviceable complete all as specified and as directed.
S&F Refrigerator condensor coil of existing capacity including necessary welding / brazing / pressure testing and removing the old unserviceable one complete all as specified and as directed.
S&F fan motor for Refrigerator of any make/capacity and removing the burnt out fan motor complete all as specified and as directed.
S&F PVC fan blade for refrigerator and removing the old unserviceable blade complete all as specified and as directed. .
M & L for removing the burnt out Glass heater of frost free refrigerator and fixing with new one complete all as specified and as directed.
S&F Refrigerator freezer box with door of existing shape and size including necessary taking out the old unserviceable one complete all as specified and as directed.
M & L for complete wiring kit for Refrigerator of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed.
S&F all kinds of PVC trays bottle tray etc on the outer door unit of the refrigerator incl removing the damaged u/s trays complete all as specified and as directed.
S&F timer of Refrigerator in replacement of any make and model suitable upto 310 Ltrs capacity complete all as specified and as directed.
S&F PCB for refrigerator of any capacity and taking out the old unserviceable one complete all as specified and as directed.
M & L for repairing and refixing of PCB for refrigerator of any capacity complete all as specified and as directed.
M & L for servicing/cleaning of Deep freezer of existing capacity with suitable chemical acid complete all as specified and as directed .
M & L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Deep Freezers complete all as specified and as directed. Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH. Note : (1) .As per the existing make of the Refrigerator . (2) Cost of charging refrigerant gas will be measured and paid under respect item of this Schedule.
M & L for replacement of old over load protector / relay with new over load protector /relay for Deep Freezer of any Capacity complete all as specified and as directed.
S&F Thermostat set complete for Deep Freezer of any capcity including removing the old unserviceable complete all as specified and as directed.
S&F Copper Capillary tube including filter / stainer with necessary brazing ,Leak testing for Deep Freezer of existing capacity complete all as specified and as directed.
M & L for supply and charging of refrigerant gas as per the requirement, testing of Deep Freezer all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract.
M & L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of Deep Freezer complete all as specified and as directed.
S&F Magnetic door gasket for Deep Freezer including removing the old unserviceable complete all as specified and as directed.
S&F fan motor for Deep Freezer and removing the burnt out fan motor complete all as specified and as directed.
S&F fan blade for Deep Freezer and removing the old unserviceable blade complete all as specified and as directed.
M & L for complete wiring kit for Deep Freezer of any make and capacity with copper wire PVC insulated single core of size 1.5 Sqmm ,testing & complete all as specified and as directed. Note: any Accessories required for this job will be measured & paid separately and taking out the old unserviceable one.
M & L for servicing of water cooler of capacity 40/80 ,60/120 Ltrs and 150/150 Ltrs including cleaning of water cooler from inside and outside with potassium permanganate, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings with suitable chemical acid complete all as specified and as directed .
M & L for replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity 40/80 Ltrs complete all as specified and as directed.
Replacement of old unserviceable compressor with new Factory made hermatically sealed compressor including rubber bushes sleeves, washers, nuts and bolts, terminal covers, clips etc for Water coolers of capacity 60/120 &150/150Ltrs complete all as specified and as directed. Note for Item No 86 & 87 :- (1) .As per the existing make of the Refrigerator . (2) Cost of charging refrigerant gas will be measured and paid under respect item of this Schedule. Make: Kirloskar / Emerson / Hitachi / Sriram / Tecum SCH.
M & L for replacement of Over load protector assembly with new OLP for Water Coolers 40 /60/150 Ltrs capacity complete all as specified and as directed.
M & L for replacement of Over relay package assembly with new relay package assembly for Water Coolers 40 /60/150 Ltrs capacity complete all as specified and as directed.
S&F Thermostat set complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directed.
S&F copper capillary tube including strainer with necessary brazing,Leak testing complete for water coolers of any capcity including removing the old unserviceable complete all as specified and as directed.
S&F Condensor fan motor of 1.5/2 Ton AC including blades complete all as specified suitable for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed.
S&F PVC Ball valve high pressure with polythene float and fly nut screwed for Iron pipe 15 mm dia complete water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed.
S&F Magnetic door gasket for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity including removing the old unserviceable complete all as specified and as directed.
S&F GI / Stainless steel water drain tray as per suitable size for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity complete all as specified and as directed.
S&F PVC Drain pipe 40mm dia for water cooler taking out the old unserviceable one complete all as specified and as directed.
S&F Running Capacitor 6/10/20 MFD for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity complete all as specified and as directed.
S&F starting Capacitor 60/80/100 MFD for water coolers 40/80 , 60/120 & 150/150 Ltrs capacity complete all as specified and as directed.
S&F Self closing taps/push cock, cast copper alloy, chromium plated screwed for iron pipe 15 mm diasuitable for 40/80,60/120 & 150/150 Ltrs capacity complete all as specified and as directed.
M & L for supply and charging of refrigerant gas as per the requirement, testing of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity complete all as specified and as directed. Note: There shall not be any duplication of gas charging for the entire period of contract.
M & L for Leak Test, leak detection and refitting the same including brazing / welding in the entire system , testing of water coolers of 40/80 ltrs, 60/120 ltrs and 150 ltrs capacity complete all as specified and as directed.
M & L for preparation of old painted surfaces of water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and as directed. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
M & L for servicing/cleaning of Desert Cooler any capacity with suitable chemical acid complete all as specified and as directed .
Supply and replacement of 4 MFD capacitor complete all as specified and as directed.
Supply and replacement of desert cooler front side PVC grills of suitable size/make as per sample complete all as specified and as directed.
Supply and replacement of water lifting pump , 240 V, Single phase submersible type (plastic body) suitable for Desert coolers complete all as specified and as directed. Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of wood wool cool pad (Khas- Khas screen) 15mm thick (minimum) of required size for side & back panel of coolers (set of three) complete all as specified and as directed.
Supply and replacement of Fan motor 230 Volts, 50Hz, three speed of existing make and capacity including fan blade complete all as specified and as directed. Make: Crompton Greeves/GE/Cool Home/AUE
Supply and replacement of swing motor 230 Volts, 50Hz, including blade for desert cooler complete all as specified and as directed.
S&F replacement of side grill (set of three for three side) made of 20 SWG GI sheet as per existing type and size suitable for existing size of desert coolers complete all as specified and as directed.
S&F and replacement of flexible PVC pipe set complete for distribution of water of desert cooler (having droping elbow-3 Nos, distribution 3 way) as per existing size, including clamping by screw/strip complete all as specified and as directed.
Supply and fix switches used to control water pump for desert cooler of any size/capacity complete all as specified and as directed.
Material and labour in repair for MS iron cross arms, bracing supports , clamps and back plates fabricated from strctural steel sections including nuts, bolts,washers, welding bending cold or hot , drilling holes for bolts in any shape or size for desert cooler stand as indicated and inclusive of one coat of zinc cromate primer , one under coat & one finishing coat & good quality of aluminium paint complete all as specified and as directed.
M & L for repairing of body of desert cooler including denting,cutting worn out portion of body upto 0.5 Sqm area and replacing with MS sheet of same guage including necessary welding,painting etc complete all as specified and as directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and as directed.
Supply and replacement of old unserviceable Rectifier unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed.
Supply and replacement of old unserviceable Relay unit of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed.
Supply and replacement of old unserviceable indication bulbs of voltage stabilizer single phase upto 5 KVA capacity complete all as specified and as directed.
Supply and replacement of Transformer unit of 5.0 KVA,4.0 KVA,3.0 KVA for voltage stabilizer complete all as specified and as directed.
Supply and replacement of Transformer unit of 2.0 KVA,1.0 KVA,0.5 KVA for voltage stabilizer complete all as specified and as directed.
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-)2.5% and of capacity 5 KVA, marking of MES number on voltage stabilizer by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on stabilizer complete all as specified and as directed. Make:Sinetrac-WMD5000UT140 to 280V/Volina-S.No-6-5.0KVA-140-280V/Microtech-PEARL EM 5170+PLUS
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-)2.5% and of capacity 4 KVA, marking of MES number on voltage stabilizer by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on stabilizer complete all as specified and as directed. Make:Sinetrac-WMD4000UT140 to 280V/Volina-S.No-5-4.0KVA-140-280V/Microtech-PEARL EM 4140+PLUS
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-)2.5% and of capacity 2 KVA, marking of MES number on voltage stabilizer by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on stabilizer complete all as specified and as directed. Make:Sinetrac-WMD2000UT140 to 280 Volts/Volina-S.No.3-2.0KVA-140-280V/Microtech-SMART EMR 4013- 130V-295V
S&F Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+/-)2.5% and of capacity 1 KVA, marking of MES number on voltage stabilizer by stamping with ink print of lettering frame size Length 20cm width 2.5 cm at least two sides on stabilizer complete all as specified and as directed. Make:Sinetrac-WMD1000UT140 to 280 Volts/Volina-S.No.2-1.0KVA-140-280V/Microtech-SMART EMR 2090-90V-260V
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 1.5 Sqmm for desert cooler complete all as specified and as directed.
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 2.5 Sqmm complete all as specified and as directed.
Supply and replacement of PVC insulated and PVC Round Sheathed, Copper Conductor of size three core 4.0 Sqmm complete all as specified and as directed.
M & L for writing/marking of MES number on E/M appliances by stamping with ink print of lettering frame size Length 15cm width 2.5 cm at least two sides on E/M appliances complete complete all as specified and as directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
BOQ_845844.xls
BOQ • 0.42 MB
8917TENDERDOCUMENTS.pdf
Tender Documents • 2.22 MB
Download all tender documents and submit your bid