Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-Finance 145 1 0 NEAR OLD LIC SHIV NAGAR VILLAGE TOWN MODIPURAM CITY MEERUT MEERUT UTTAR PRADESH 250110 INDIA | MEERUT | UTTAR PRADESH | 250110 | L1 | Accepted-Finance OK | |
| 2 | L2₹1.9 L+₹19,305 (11.4%)Accepted-Finance | L2 | Accepted-Finance OK | |
| 3 | L3₹1.9 L+₹21,435 (12.7%)Accepted-Finance 23 B NEW MANDI NEW MANDI MUZAFFARNAGAR MUZAFFARNAGAR UTTAR PRADESH 251001 INDIA | MUZAFFARNAGAR | UTTAR PRADESH | 251001 | L3 | Accepted-Finance OK |
Tender Value
₹1.8 L
EMD Value
₹2,000
Closing Date
13 Sept 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC NOIDA
220 KV SUBSTATION SECTOR-20 NOIDA
Construction of 1 No. 33 kV AIS Bay at various 220 kV and 132 kV substations under ETD-I, Noida
2023_UPTCL_820947_2
E-T-28/ETCN/2023-24
Open Tender
Electrical Works
Item Rate
30 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD NOIDA
₹2,000
29 Sept 2023
19 Aug 2023
14 Sept 2023
19 Aug 2023
13 Sept 2023
19 Aug 2023
Amount
Shifting of following structures from store to the site of work and complete erection of the ABL, ALP etc. (auxiliary structures),spring washers and flat washers shall be provided in each of the Nuts and bolts of the structures (These will be provided free of cost by the department alongwith the structures) approximate quantity and weight of these structures alongwith nuts, nolts and washers is as under. (i) Auxiliary structure type ABL (02 Nos) (ii) Auxiliary structure type ALP (06Nos)
Erection of following equipments as per technical specification including shifting from store site to erect
33 KV Vaccum Circuit Breaker
33 KV Bus Isolator
33 KV Line Issolator
33 KV CTs
33 KV CT Juction Box
Erection of 33 kV Tripple feeder control panle
Jumpering work as given below by ACSR panther conductor- (i) Between Main Bus and Bus Isolator of new bay (ii) Between Bus Isolator and Circuit Breaker (iii) Between Circuit Breaker and CTs (iv)Between CTs and Isolator,All jumpering work from point (i) to (iv) make one job.
Laying of following control cables in trenches and cable asement racks including dressing,clamping etc.
PVC control cable 2x2.5 sq.mm
PVC control cable 4x2.5 sq. mm
PVC control cable 6x2.5 sq. mm
PVC control cable 10x2.5 sq.mm
Preparation of cable interconnection for 33 KV Bay from CB to C&R Panel.
Termination of control cables and fixing of cable glands as per the protection scheme and cable schedule for the all equipments associated with 01 Nos 33 KV Bay.
Earthing of various equipment structur with MS Flat of size 50x6 mm, the work comprises of making trenches by digging of earth upto the earthmat level,laying of MS flat on the dug trench as well as above the fround on equipment/structures alongwith its bendinf to give proper shape, MS flat size 50x6 mm shall be provided by department free of cost. The work also including making of half round joints (between MS flat and earthmat bar) , lap joints ( for joining MS flat) tack welding joints ( on structures) and end points on structure/ equipments.Painting of the MS flat with one coat of red oxide primer and two coats of synthetic enamel paint (First quality of Berger/Asian make) would have to be done alongwith back filling of earth in trecnches.
M/s S.S. Refregeration
RAHUL ELECTRIC ENGGINEERING WORKS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .