Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC 2 BAISHNAB SETH 1ST LANE KOLKATA 700006 | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹35.4 L+₹38,561 (1.10%)Rejected-Finance 8 27 BEJOYGARH JADAVPUR KOLKATA 700 032 | KOLKATA | WEST BENGAL | 700032 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.6 L+₹56,327 (1.61%)Rejected-Finance 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹35.9 L+₹88,215 (2.52%)Rejected-Finance 25A KUSTIA ROAD KOLKATA 700 039 | KOLKATA | WEST BENGAL | 700039 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹36.2 L+₹1.1 L (3.13%)Rejected-Finance 7 11 1 BROJONATH LAHIRI BISHNUPUR SOUTH 24 PGS WEST BENGAL 743503 | 24 PARAGANAS SOUTH | WEST BENGAL | 743503 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹35.5 L
EMD Value
₹71,000
Closing Date
22 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR MAINT OF BOOSTER PUMP, CENTRIFUGAL DEEP BORE, MONOBLOCK PUMPS, OPEN WELL SUBMERSIBLE PUMPING SETS WITH CONNECTED ALLIED WORKS AT INSIDE FORT WILLIAM UNDER GE(FW) KOLKATA
2023_MES_630689_1
8196/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (FW) Kolkata
₹71,000
19 Jan 2024
1 Dec 2023
23 Dec 2023
1 Dec 2023
22 Dec 2023
15 Dec 2023
Amount
Demolition of cement concrete of any description and in any position along with taking out of common steel base of pump sets of any capacity in foundation for support of pumps for reuse/stacking in store all as specified and as directed by Engr-in-Charge NOTE:-Dismantling of pump & motor and pipe lines shall be measured under relevant items of this schedule.
M & L plain cement concrete (1:2:4), type B2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete as suitable for foundation of pump set of rating not exc 100 HP capacity complete all as specified and directed.
M & L plain cement concrete (1:1.5:3), type A1 (using 20mm graded stone aggregate) as in filling and mass concrete above foundation as directed by Engr-in-Charge suitable for capacity exc 100 HP Motor & Pump any type complete all as specified and directed.
M&L Framed Work such as brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary, gusset plates, riveting, etc. conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any descriptions, complete all as specified and directed.
M&L Brick Work with Flyash Bricks (with Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:6, complete all as specified and as directed.
M & L rendering 10 mm thick on brick or concrete surface in cement mortar (1:6), finished even and smooth without using extra cement complete all as specified and directed.
Disconnecting all electric / water supply connection from the monoblock / cenrtifugal pump set of make Kirloskar electric driven AC 3 phase, 415 Volts, transporting to workshop dismantling, removing the burnt out windings, cleaning the starter slots and rewinding with super enamelled copper wire of suitable gauge, insulating, proper heat varnishing, re-transportation and re-installation at same position including commissioning and testing complete for the following capacity :-
Motor of capacity 2HP/3HP Make : Crompton Greaves, Model No -632/1117-CF
Motor of capacity 5 HP Make : Kirloskar, Model No 632/1127.CF
Motor of capacity 7.5 HP Make : Kirloskar, KDS 852
Motor of capacity 10 HP Make : Kirloskar, Model No KDS 1050
Motor of capacity 15 HP Make : Kirloskar, Model No KDS 1570
Motor of capacity 20HP Make : Kirloskar, Model No KDS 2050 +
Motor of capacity 25 HP Make : Kirloskar, Model No KDS 2560
Motor of capacity 30 HP Make : Kirloskar, Model No KDS 3068
S&F Ball bearing for AC 3 phase 415 Volts induction motor / monoblock pump set of the following capacities, in replacement as directed by the Engineer-in-Charge :-
Motor / Pump set of capacity 2HP/3HP Make-SKF 6305 - RS1
Motor / Pump set of capacity 5 HP Make-SKF 6306 - 2RS1/C3
Motor / Pump set of capacity 7.5 HP. Make-SKF 6306 - 2Z, 6306-2Z/C3
Motor / Pump set of capacity 10 HP. Make-SKF 6307 - 2RS1
Motor / Pump set of capacity 15 HP. Make-SKF 6308 - 2 RZNR/C3
Motor / Pump set of capacity 20 HP. Make-SKF 6308 - 2 RZNR/C3
Motor / Pump set of capacity 25 HP. Make-SKF 6309 - 2 RZNR/C3
Motor / Pump set of capacity 30HP Make-SKF 6310 - 2RS1
Dismantling and taking out of the following capacity pump sets of any type (monoblock/centrifugal) complete of any make from any installation , transporting to workshop and re-installation in same position after replacement of worn out spare parts and painting with one coat of synthetic enamell paint to pump only including commissioning and testing on completion all as directed by the Engr-in-Charge. Note : Spares parts will be measured and paid separately under relevent item
Motor / Pump set Capacity of 2 to 3 HP
Motor / Pump setCapacity 5 HP
Motor / Pump set Capacity of 7.5 HP
Motor / Pump set Capacity of 10 HP
Motor / Pump set Capacity of 15 HP
Motor / Pump set Capacity 20HP
Motor / Pump set Capacity 25 HP
Motor / Pump set Capacity 30HP
Disconnecting of all electric connection, taking out 3 phase, 415 Volts induction electric motor from any installation of any make (other than, as catered under Item No. 1 & 2 here-in-before), transporting to workshop, dismantling, overhauling with proper heat varnishing, (for proper insulation), re-metalling, machine polishing of rotor shaft, terminal box and applying one coat synthetic enanel paint, transporting back to work-site for reinstallation of the same including testing complete for the following capacities :-
Motor of capacity 2 HP/3HP
Motor of capacity 5 HP
Motor of capacity 7.5 HP.
Motor of capacity 10 HP.
Motor of capacity 15 HP
Motor of capacity 20HP
Motor of capacity 25 HP
Motor of capacity 30 HP
Taking out exisiting open well submersible pumping sets, of capacity 7.5 HP, 03 phase dismantling the pump sets from motor and removing all burnt/worn out coils cleaning the slots and rewinding with super enamelled copper wire of existing size including varnishing two coats, drying and reassembling the electric motor re-transporting, re-installation and testing complete all as specified and as directed by Engr in Charge.Make:Kirloskar,Model No-KOS 830+
All as per Item No.12 here-in-before but of capacity 10 HP & three phase.Make:Kirloskar,Model No-M-KOS 1030+
S/F stainless steel filter net suitable for 7.5 HP/10 HP submersible pump as in repair ,complete all as specified and as directed by Engr in Charge.
Supply only cast iron impeller, suitable for 5 HP capacity monoblock pump as directed by the Engineer-in-Charge. Make - Kirloskar/CG/
All as per item serial No 15.00 but suitable for 7.5 HP
All as per item serial No 15.00 but suitable for 10HP
All as per item serial No 15.00 but suitable upto 15HP
All as per item serial No 15.00 but suitable upto 20HP
All as per item serial No 15.00 but suitable upto 25HP
All as per item serial No 15.00 but suitable upto 30HP
M&L Re-metaling, grinding and re polishing of damaged CI impeller cover of pump capacity 5 HP to 20 HP monoblock pump complete as directed by Eng-in-charge.
M&L Re-metalling, grinding and re polishing of damage CI impeller of pump capacity 20 HP to 30 HP, completed as directed by the Engineer-in-Charge.
S&F Gun metal gland bush including graphite gland packing for induction / monoblock pump set of capacity 5 HP to 30 HP, as in replacement complete all as specified and as directed.
S&F MS studs with nut as per exsiting size & shape of size 1/4" to 5/8" as directed as in repair complete all as specified and as directed.
S&F Impeller key suitable for any type of pump , as in repair complete all as specified and as directed.
S&F Check nut (suitable for any type of pump), as in repair complete all as specified and as directed.
Cutting and removing of old unserviceable nut bolt and washer of size 3/8" to 5/8" from the pump set and base frame and S&F MS nut bolt and washer of same size fixed in same position, complete as directed by the Engineer-in-Charge.
Re-metalling and re-shaping of impeller key slot, for pumps complete as directed by the Engineer-in-Charge.
Removing the existing foot valve/check valve of any type carefully by disconnecting water supply pipes of size 50mm to 65mm dia and opening, cleaning including replacement of new gasket (Flap) bolt, nut, washers of suitable size and refixing the same after repairs complete as directed by the Engineer-in-Charge.
All as per item Ser No 31 here in before but of pipe size 80 mm to 100 mm.
M&L Checking and balancing of old shaft for monoblock / centrifugal pump of any capacity / type including re-metalling and polishing, and re fixing complete as directed by the Engineer-in-Charge.
S&F SS Sleeve for any type of monoblock and centrifugal pump of capacity 5 to 20HP as in repair complete all as specified and as directed.
Ditto all as per item No 31 for 20 to 30 HP centrifugal pump set.
M&L Greasing for bearing (of centrifugal pumps / Monoblock pumps) of 5 to 15 HP pump sets any make complete all as directed by Engr-in-Charge.
M&L Greasing for bearing (of centrifugal pumps / Monoblock pumps) of 20 to 30 HP pump sets complete all as directed by Engr-in-Charge.
S&F MS star/round coupling with star rubber bush / Rubber round coupling with MS plate incl necessary nut, bolt & washers complete of centrifugal pumps 5 HP to 15 HP capacity complete all as specified and as directed.
Ditto all as per item No 36 -above but of pump capacity 20 to 30 HP.
S&F Motor cooling fan suitable for 5 HP to 15 HP induction motor as in repair complete all as specified and as directed.
All as per item No 38 but for 20 to 30 HP induction motor.
Disconnecting of all electric / water supply connection from the panel/water line, taking out submersible pump set including column pipe (motor and pump) of 22.5 HP to 25 HP capacity by using tripod & chain pully from site and transporting to workshop, dismantling the pump part by part, after stripping off the pump and motor, segregating the unserviceable and serviceable parts, cleaning, slot cutting, re-metalling and machine polishing of outer cover, threading of all parts as required, re-assembling including replacement of worn out spares and painting with one coat of synthetic enamel paint, re-transporting to work-site lowering the pump set including column pipe and re-connection of electrical and mechanical joint, testing of pump set at Queen's Barrack, Royal Barrack, AOI, Training Area, complete all as directed by Engr- in- Charge. Note : Column pipe, New spares, nuts, bolts, gasket & painting of column pipes shall be measured and paid separately
M&L Rewinding of submersible motor of capacity 22.5HP to 25 HP of any make and any type with super enamelled copper wire of suitable gauge, insulated and including re-assembling the motor, jointing with insulated materials etc,. including testing complete all as directed by Engr-in-Charge. Make : CALAMA,KSB & Crompton Greaves
S&F PVC insulated flat industrial copper cable, of cross-sectional area 10 sq mm x 3 core, suitable for submersible pump, including necessary incoming and outgoing electric connections, copper lugs, water proofing compound etc., connected to starter / motor as in repair complete all as specified and as directed.
Supply only following spare parts for replacing unserviceable parts against Item No.41 here-in-before.
Cable guard
Suction case strainer
Counter thrust bearing
Diffuser ring
Bearing sleeve
Bearing bush upper / lower
Suction case (Intermediate)
Neck ring (Intermediate seal ring)
SS Pump shaft
Shaft sealing bush
Impeller (Gun metal)
Gun metal impeller
Key of impeller
Sand guard
Seal cap
Coupling for pump
Stage casing (Bowl)
Adjusting cap
Rubber cap
Sleeve for shaft
Seal for shaft
Ring insert for non-return valve
Oil seal
Diaphragm
Circlip
Coupling sleeve
Upper bearing bush
Lower bearing bush
Thrust bearing plate
Counter thrust segments
Drain plug
Sealing ring
Stud ring upper / lower
Thrust carbon
Rotor sleeve
Motor base
Pressure compensation rubber
Gunmetal bearing bush
Stainless steel stud
Rotor re-metalling, grinding & polishing complete
SS nut of size 8 mm / 12 mm
Nylon washer
Bearing bush (rubber)
Flange upper / lower
Lock nut
Supply only MS column pipe 125mm bore grade (heavy duty) flanged type complete with nuts, bolts, rubber including groove for cable entry system with gasket etc of 10 ft length, complete all as specified and as directed. Make : Jindal /TATA/SAIL
All as per item No 45 but of size 150 mm bore
S&F MS Nipple 150 mm bore with heavy flange with suitable holes and reducer complete duly welded and threaded as required in repair, complete all as directed by Engineer-in-Charge.
All as per item No 43 but for pipe of size 80 to 125 mm
Taking down Non return valve assembly size 100mm to 200mm by opening the nut, bolts and washers, cleaning the valve replace with new rubber gasket, balls and refix the same after completion, complete all as directed by Engineer-in-Charge.
S&F Mild steel bore well cap for 8" x 12" tube well in two parts 10mm thick with cable/column pipe entry system and locking arrangements as in repair complete all as specified and as directed.
S&F MS nut and bolt with MS washer of any size for jointing of MS column pipes / pump mounting bolts / valves etc. as in repair , complete all as specified and as directed.
S&F Rubber gasket 3mm thick for jointing of column pipe of 100 to 150 mm bore as in repair , complete all as specified and as directed.
M&L Cleaning of old painted surfaces of 150 mm bore column pipe with iron brushes and applying one coat of black bituminous paint (suitable for drinking) on the surface of column pipe (inside and outside) of length 10' Ft, complete all as specified and as directed.
All as per item No 53 but of pipe size 125 mm bore
Welding work in exc 6mm but n. exc 9mm running pipe line / MS frame in any length and thickness not exceeding 9 mm in any position complete all as directed by Engr-in-Charge.
S&F Three pole power contactor of type ML-3, suitable for 415 Volts, including necessary incoming and outgoing electric connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T Cat No. SS 90721 or equivalent model in other makes specified in tender).
S&F Three pole power contactor of type ML-2, suitable for 415 Volts, including necessary incoming and outgoing elect connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T, Cat No SS 90701 oor equivalent model in other makes specified in tender).
S&F Three pole power contactor of type ML-1.5, suitable for 415 Volts, including necessary incoming and outgoing electric connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T, Cat No SS 91851 or equivalent model in other makes specified in tender).
S&F Fully automatic star delta starter in Sheet-Steel Enclosure Type ML 3 FASD (Motor Rating AC-3 Duty, 415V, 50Hz, 3Ph) incl necessary incoming & outgoing elect connections, copper lugs, etc., as directed. Make : L&T, Cat No SS90730 / BCH Cat No:NASANLEN
Ditto all as per item No 54 above but type ML 2 FASD (Motor Rating AC-3 Duty, 415V, 50Hz, 3Ph. Make : L&T, Cat No SS90705 / BCH Cat No:NASAMLEN
S&F DOL starter in sheet steel enclosure MN 16 for motor rating of 9 to 15 Amps including all necessary electric connections and fixing arrangement as per site requirement all as directed by Engr-in-charge. Make :- L&T Cat Part No SS-94351 / BCH Cat No:SAWPLZ
S&F MCB triple pole 32 Amps, 'C' curve including necessary incoming and outgoing elect connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L & T Cat Part No. BB30400C or equivalent model in other makes specified in tender).
S&F Single Phase Preventor Relay - Sz5 380V AC (6 wires) including necessary electric connections as in repair complete all as specified and as directed. Make : L&T Cat No CS94824LOOO or equivalent model in other makes specified in tender).
S&F Push button Actuator switch of any colour including necssary connections complete all as specified and as directed. Make: L & T Cat No SS91519 or equivalent model in other makes specified in tender).
S&F Indication lamp set LED type as in repair complete all as specified and as directed.
S&F ML bi-metal overload relays, ranging from 10 Amp to 16 Amp, including necessary incoming and outgoing elect connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T, Cat No SS 91858 OO BO / BCH Cat No:MC305ANA3L
S&F Single phase preventor relay with timer- SDz5, SPPR + Timer, 415V including necessary electric connections as in repair complete all as specified and as directed. Make : L&T, Cat No XM81809OOOO or equivalent model in other makes specified in tender).
S&F ML bi-metal overload relays, ranging from 10 Amp to 16 Amp, including necessary incoming and outgoing elect connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T, Cat No SS 91858 OO BO / BCH Cat No:MC305ANA3L
S&F AC electronicl timer ST 100 3 phase electronic timer ranging from 3 - 30 sec including necessary incoming and outgoing elect connections, copper lugs, etc., as in repair complete all as specified and as directed. Make : L&T, Cat No ST80328OOOO
S&F in repairs, 80mm dia Gun metal, globe or gate valves with iron wheel head, ISI marked screwed both ends for iron/GI pipe and fixed complete all as specified and as directed.
All as per item No 71 above but 25mm dia globe or gate valve.
All as per item No 71 above but 40mm dia globe or gate valve.
All as per item No 71 above but 50mm dia globe or gate valve.
All as per item No 71 above but 40mm dia globe or gate valve.
S&F PVC insulated single core solid copper conductor of cross sectional area 25 sq mm for inter-connection as in repair complete all as directed by the Engr-in-Charge.Make:MESCAB/Finolex
All as per item No 76 but of cable size 16 Sqmm.
All as per item No 76 but of cable size 10 Sqmm.
All as per item No 76 but of cable size 6 Sqmm.
All as per item No 76 but of cable size 2.5 Sqmm.
S&F Add on block 2NO + 2NC including necessary electric connections as in repair complete all as directed by the Engr-in-Charge. Make : L&T Cat No CS94114 or equivalent model in other makes specified in tender).
S&F Add on block 1NO + 1NC including necessary electric connections as in repair complete all as directed by the Engr-in-Charge. Make : L&T Cat No CS94118 /BCH Cat No:C320KGT*11 or equivalent
S&F Single phase preventor (auto re-set, 40 Volts unbalance), as in repair complete all as directed by the Engr-in-Charge. Make : Minilec, Cat No VSP 2 or equivalent
M&L Stripping off existing starter panel and replace of single phase preventor matching with motor of type VSP-3 and re-assembling of the panel including rectification of fault and safety device, adjustment of time etc complete as directed by the Engr-in-Charge. Make : Minilec/ BCH.
S&F MCCB 3 pole 25 KA breaking capacity 63 A with thermal magnetic release as in repair complete all as directed by the Engr-in-Charge.Make: L&T Cat No:CM91612OOJOOG or equivalent model in other makes specified in tender).
S&F MCCB 3 pole 25 KA breaking capacity 100 A with thermal magnetic release as in repair complete all as directed by the Engr-in-Charge.Make: L&T Cat No:CM91612OOKOOG or equivalent model in other makes specified in tender).
S&F MCCB 3 pole 25 KA breaking capacity 200 A with thermal magnetic release as in repair complete all as directed by the Engr-in-Charge.Make: L&T Cat No:CM90638OONO/BCH Cat No:XT2S250NJ3FB0U0 or equivalent model in other makes specified in tender).
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level,connected to galvanised iron strip of size 32X6 mm as earthing lead by means of bolts ,nuts,check nuts and washers protected by 40mm Dia (medium grade) GI tubing ,funnel ,wire mesh,20mm bore GI tubing (light grade) watering pipe including concrete pit in PCC (1:3:6)type C-1, all as shown in Electric plate no.3 connected to earthing test point all as specified or indicated including testing on completion alongwith Pit Cover of Dimension 45X45X5 CM complete all as specified and as directed.
S&F Three pole power contactor MNX-12 suitable for 415V, 50Hz as in repair all as directed. Make : L&T, Cat No- CS 94109 or equivalent model in other makes specified in tender).
S&F Three pole power contactor MNX-25 suitable for 415V, 50Hz as in repair complete all specified and as directed. Make : L&T, Cat No- CS 94110 or equivalent model in other makes specified in tender)
S&F Three pole power contactor MNX-32 suitable for 415V, 50Hz as in repair complete all specified and as directed. Make : L&T, Cat No- CS 94111or equivalent model in other makes specified in tender).
S&F Three pole power contactor MNX-50 suitable for 415V, 50Hz as in repair complete all specified and as directed. Make : L&T, Cat No- CS 97075 or equivalent model in other makes specified in tender).
S&F MCB 'C' curve 6-32 A,10 KA as in repair complete all specified and as directed. Make : L&T, Cat No- BB10320C, BCH,Cat part No:BCHX10SPC32or equivalent model in other makes specified in tender).
S&F SPN MCB 'C' curve 40 A,10 KA as in repair complete all specified and as directed. Make : L&T, Cat No- BB20400C,BCH,Cat part No:BCHX10SNC40 or equivalent model in other makes specified in tender).
Supply and fix in repairs MS pump set base frame suitable for 5 to 7.5 HP pump set incl necessary dismantling of old PCC and provision of new PCC 1:2:6 foundation, MS foundation bolt, nut & washers complete all as directed.
Supply and fix in repairs MS pump set base frame suitable for 10 to 20 HP pump set incl necessary dismantling of old PCC and provision of new PCC 1:2:6 foundation, MS foundation bolt, nut & washers complete all as directed.
M&L for complete removal of existing paint from electrically operated centrifugal pump set of 5 HP capacity and applying two coats of duco paint of approved shade in spray painting over a coat of red oxide primer and cleaning of name plates complete all specified and directed.
All as per Sl item No.97 above but 7.5 HP
All as per Sl item No.97 above but 10 HP
All as per Sl item No.97 above but 15 HP
All as per Sl item No.96 above but 20/25/30HP HP
Taking out unserviceble LT panel board of any size and Supply, install, commissioning and testing of Indoor type LT Starter Panel Board, cubical type, dust and vermin proof,doule door with locking arranngemet, both side openable made out of 2.00 mm thick CRCA sheet of minimum size 1200 mm x 1200 mm x 400 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, cabinet and all members chemically treated with MSR solution for anticorrosive treatment and powder coated (shade RAL-7032) inclusive of four numbers copper bus bar 200 Amps capacity of suitable (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 40X 40X 5 mm with legs not more than 60 cm including grouting with PCC (1:2:4) complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories :- Location :-Horse Riding Pump House /SO-II Pump House
S&F earth contuinity conductor with aluminium strips of size 25 mm X 3 mm, fixed to wall/on batten/ recess/ chases/ buried in ground/drawn in conduit or pipes/fixed to poles/ from top of pump house to test point or any other indicated situation for loop earthing etc including providing fixing saddles, porcelain insulators etc as required complete all as specified and directed.
Development of Tube Well with Air Compressor of suitable Capacity till Sand/Mud/Silt-Free Water of Potable quality obtained and to achieve Minimum Discharging Capacity of 10000 GPH from the Tube Well by using same Air Compressor and the testing carried out for at least 8 continuous hours uninterrupted Run Per Day for 2 Continuous Days, complete all as specified and as directed. NOTE : Air Compressor with all accessories and Fuel, V Notch, etc., shall be born by the Contractor and the rated quoted for the same shall deemed to be included in the QUOTED UNIT RATE.
Taking out unserviceble LT panel board of any size and Supply, install, commissioning and testing of Indoor type LT Starter Panel Board, cubical type, dust and vermin proof,doule door with locking arranngemet, both side openable made out of 2.00 mm thick CRCA sheet of minimum size 1200 mm x 1200 mm x 400 mm, fabricated in CPRI approved factory with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, cabinet and all members chemically treated with MSR solution for anticorrosive treatment and powder coated (shade RAL-7032) inclusive of four numbers copper bus bar 200 Amps capacity of suitable (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland),and two numbers Danger Notice Plate (of size 20 cm x 15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with angle iron frame with base 40X 40X 5 mm with legs not more than 60 cm including grouting with PCC (1:2:4) complete all as directed by the Engr-in-Charge including supply and fixing of the following accessories
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
MAZUMDER ENTERPRISE
SANTOSH INTERNATIONAL
SIMPLEX DRILLING COMPANY
SK CONSTRUCTION SYNDICATE & ENGG CO
M/S SHRI P K ACHARJEE
MS HORIZEN
MS JYOTI INDUSTRIES
S.S.ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .