Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC P O RANGIA WARD NO 3 DIST KAMRUP ASSAM | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹40.1 L+₹9,915.23 (0.25%)Rejected-Finance | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹41.2 L+₹1.2 L (2.97%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹42.2 L+₹2.2 L (5.62%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹43.2 L+₹3.2 L (8.03%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
27 Jan 2020, 6:00 pmClosed
GE RANGIA
GE Rangia C/O 99 APO Rangia
SPECIAL REPAIR TO BUILDING NO. ET-209, ET-210, ET-167 AND OTHER SANCTIONED WORKS AT RANGIA MILITARY STATION UNDER GE RANGIA
2019_MES_310883_1
8338/RNG/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
RANGIA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹88,000
Yes
14 Feb 2020
31 Dec 2019
28 Jan 2020
31 Dec 2019
27 Jan 2020
15 Jan 2020
Amount
Taking down carefully aluminum/copper point wiring (light fan, socket or power) complete incl fittings and fixtures such as switches, sockets, light fittings, ceiling rose, pendants, lamp holders, shade conical, regulators, DBs, MCBs, etc. and removing unserviceable fittings and fixtures with wiring cable, battens, wooden boards etc from site and making good disturbed surfaces of walls, floors, ceiling etc, complete all as per specified and as directed by Engineer-in-Charge.
Taking down main switches, DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs of any type complete all as per specified and as directed by Engineer-in-Charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLS copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with sunk iron pressed steel terminal box & 3.00mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator including 1.5 sqmm size PVC insulated multistranded FRLS copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
Supply and fix ceiling rose surface backelite three terminals, PVC/polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch piano flush type, 6 Amps 240 volts single pole one way, complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosure for double door SPN 02 Ways DB when MCBs to be used single pole neutral, complete all as specified and as directed by Engineer-in-charge.
Supply and fix MCB, SPN, 6-32 Amps, AC 230Volts, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED batten 4ft long, Ultra bright, glass shell, glare free, wide angle, suitable for 20W LED tube, single side connection, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED tube 20W with single side connection complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down old unserviceable one, complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 5 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs), complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
Supply and lay earth continuity conductor or main GI earthing lead fixed to wall or on batten or recces or chasses or burried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. of 4mm dia galvanised iron or steel wire complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 10 Sqmm 3 Core including taking down old unserviceable cable complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 10 Sqmm 3 Core complete all as specified and as directed by Engineer-in-charge.
Taking down and hanging ceiling fan of 1200/1400 mm sweep to its original position after painting it with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc complete all as specified and as directed by engineer-in-charge.
All as per Serial item No. 03 above but for one fan point controlled by one way switch.
All as per Serial item No. 03 above but for one exhaust fan point controlled by one way switch.
All as per Serial item No. 03 above but for one 3 pin socket outlet 5 AMPs on same board.
All as per Serial item No. 03 above but for one 3 pin socket outlet 5 AMPs on independent board.
All as per Serial item No. 03 above but with 4 sqmm (nominal area) cable with 4.0 sqmm size copper earth continuity conductor for 3 pin 15 Amps socket out let on independent board.
All as per Serial item No. 03 above but for one bell point controlled by 5 Amps bell push.
Supply and fix switch modular type, 6 Amps 230 volts, single pole, one way, with white cover plate and frame, complete all as specified and as directed by Engineer-in-charge.
Supply and fix bell push, modular type, 10 Amps 230 volts, single pole, one way, with white cover plate and frame, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling fan step regulator, modular type, 2 modules, 100W with white cover plate and frame, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination, modular type, 6 Amp 5 pin, with white cover plate and frame complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination, modular type, 6/16 Amp 5 pin, with white cover plate and frame complete all as specified and as directed by Engineer-in-charge.
Supply and fix SP&N DBs, double door, 240 volt, 12 way, complete all as specified and as directed by Engineer-in-charge.
S&F MCB single pole & neutral 240 volts 63 Amps, complete all as specified and as directed by Engineer-in-charge.
S&F MCB single pole, 240 volts, 6 - 32 Amps, 10 KA, complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED bulb, 7watt, Retrofit type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix recess/pendant mounting ultraslim LED flat panel 2'x2', 36W with high efficient LEDs and glare free opal diffuser complete all as specified and as directed by Engineer-in-charge.
Supply and fix Call bell ding dong muscial type, AC, 230 Volts, Single pole, complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 25 Sqmm 3 Core including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
M&L for power socket MCB protected (sheet metal enclosures) with plug top and single pole MCB of 20 A 'C' curve 10KA capacity, complete all as specified and as directed by Engineer-in-charge.
Supply and fix PVC/Non-metallic exhaust fan, single phase, 230 V and 200 mm dia complete all as specified and as directed by Engineer-in-charge.
Taking down vertical storage type electric water heater (geyser) of storage capacity 25 ltrs for servicing by dismantling inner tank including replacement of unserviceable spare parts like thermostat, heating element & indicating lamps, pressure release valve, fiber gasket, nuts & bolts, repairs to internal wiring and painting externally including fixing back on wall after repairing complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLS copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00 mm thick laminated sheet cover for mounting fittings etc like switches sockets and fan regulator incl 1.5 sqmm size PVC insulated multistranded FRLS copper conductor cable as earth continuity conductor and connected to earth dolly complete all as specified and as directed for one light point controlled by one switch, complete all as per specified and as directed by Engineer-in-Charge.
All as per Serial item No. 38 above but for one ceiling fan/exhaust fan point controlled by one way switch.
All as per Serial item No. 38 above but for one 3 pin socket outlet 5 AMPs on independent board.
All as per Serial item No. 38 above but for one 3 pin socket outlet 5 AMPs on same board.
All as per Serial item No. 38 above but with 4 sqmm (nominal area) cable with 4.0 sqmm size copper earth continuity conductor for 3 pin 15 Amps socket out let on independent board.
All as per Serial item No. 38 above but for one bell point controlled by 5 Amps bell push.
Supply and fix bell push, 5 Amp, flush type, single pole, 230 volts, complete all as specified and as directed by Engineer-in-charge.
Supply and fix socket outlet, 5 pin 6 Amps, flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 6 Amp 5 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix switch socket combination 05/16 Amp 6 pin flush type, complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED light fitting single tube 1 X 20 Watts, 240 V surface and wall mounted led batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper contactor cable with 1.5M long suitable size, complete all as specified and as directed by Engineer-in-charge.
Supply and fix lamp holder, PVC/Polycarbonate type with back plate suitable for batten / angular fittings including 10 Watt LED bulb, complete all as specified and as directed by Engineer-in-charge.
Supply and fix recess/pendant mounting ultraslim LED flat panel 2'x2', 34W with high efficient LEDs and glare free opal diffuser complete all as specified and as directed by Engineer-in-charge.
Supply and fix Bulk head fitting in di-cast aluminium housing and frosted glass with LED 18W lamp complete all as specified and as directed by Engineer-in-charge.
Supply and install 1.5 TR capacity BEE 5 star rating window type AC complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality, 5 star rating, electric driven, single phase, complete all as per specified and as directed by Engineer-in-charge.
M&L for submain wiring including PVC casing caping 2 run 6 Sqmm cable PVC insulated copper conductor multi-standed or FRLS cable drawn through PVC casing caping with all accessories including 4 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly, complete all as per specified and as directed by Engineer-in-charge.
Supply and fix metallic finish exhaust fan, single phase, 230 V and 225-230 mm dia with steel bird guard to protect fan in running condition, complete all as specified and as directed by Engineer-in-charge.
Supply and fix SP&N DBs, double door, 240 volt, 08 way, complete all as specified and as directed by Engineer-in-charge.
S&F in repair PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 16 Sqmm 2 Core including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 16 Sqmm 2 Core complete all as specified and as directed by Engineer-in-charge.
S&F House service bracket (Hook type) complete with 3.0m long G.I pipe 40mm dia medium grade, two nos. 90 degree bends, M.S hook and stay or guy, complete all as specified and as directed by Engineer-in-charge.
Supply and fix ceiling fan AC single phase 230/240V of size 1200 mm sweep, BEE 5star rating, including electronic type regulator and accessories like hook, rubber insulators, split pin, bush etc. complete all as specified and as directed by Engineer-in-charge.
S&F 5 KVA capacity of volatge stabilizer for automatic operation, single phase, naturally air cooled, designed for input voltage variation between 170V to 250V with output volatge stabilized at 230V with accuracy of +/- 2.5%, complete all as specified and as directed by Engineer-in-charge.
S&F flood light integral type hoarding light fitting with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP-66 of 30 W LED fitting, including channel for fitting LED flood light, complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 06 Sqmm 2 Core complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal enclosure for single door SPN 02 Ways DB when MCBs to be used single pole neutral, complete all as specified and as directed by Engineer-in-charge.
S&F post-top, energy saving, spun aluminium landscape luminaire light fitting LED type 25W, 5700K with LED bulb on gate pillar/G.I pipe of dia up to 80mm including necessary electric connections, complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated, electric cable with copper conductor, 1100 volts grade having cross-sectional area 2.5 Sqmm 3 Core complete all as specified and as directed by Engineer-in-charge.
Supply & fixing or laying galvanised steel tubing light grade (ISI marked) for protection of under-ground cable on poles/ walls alongwith fixing clamp, nuts, bolts & washers or under road crossing etc. of size 32 mm bore, complete all as per specified and as directed by Engineer-in-charge.
Boring of holes under road, pavement, hard standing, drain etc. by conventional method not exceeding 5 mtr in length for laying of cable for protection under GI pipe complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing rigid non-metallic PVC conduit heavy duty exclusive of boxes, but inclusive of all tees, bends, elbows, reducers and all other fixing accessories of size 25 mm on wall/floor etc. complete all as per specified and as directed by Engineer-in-charge.
Supply and fix VTP&N DB, degree of protection : IP43, 415 volts, 8 ways, 8 modules for incoming for MCCB and 24 modules for out-going with 100 Amp rated bus bar triple pole & neutral, double door, complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 100 amps, 4 pole, 415 Volt with breaking capacity 25 KA, complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 63 amps, 4 pole, 415 Volt with breaking capacity 35 KA, complete all as per specified and as directed by Engineer-in-charge.
S&F MCCB 63 amps, 4 pole, 415 Volt with breaking capacity 25 KA, complete all as per specified and as directed by Engineer-in-charge.
Supply and fix Heavy duty exhaust fan, AC, single phase 230/240V of size 450mm sweep, 900RPM with louver on wall including cutting of hole on wall for fixing and finishing wall surfaces with the existing colour wash/white wash etc, complete all as per specified and as directed by Engineer-in-charge.
Supply and fix PVC exhaust fan, AC, single phase, 230/240V of size 250mm sweep including cutting of hole on wall for fixing and finishing wall surfaces with the existing colour wash/white wash etc, complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing rigid non-metallic PVC conduit heavy duty exclusive of boxes, but inclusive of all tees, bends, elbows, reducers and all other fixing accessories of size 32 mm on wall/floor etc. complete all as per specified and as directed by Engineer-in-charge.
S&F external LED light fitting of 8W, 4000K(500mm) with diffusar at the upper portion acts a beacon of path guidance in a landscape environment including necessary PCC work for mounting the light fitting complete all as per specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel plate electrode 60 cm x 60 cm x 6 mm thick burried directly under ground (earth pit not less than 2.25 mtr deep below ground level) connected with galvanized earth strip 32x6 mm by means of nuts, bolts, check nuts and washers of galvanized iron strip or steel all as shown in electrical plate No 5 connected to earthing test point including necessary earth work and PCC (1:3:6) type (using 20 mm graded stone aggregate) pit and CI cover and watering pipe 15mm dia medium grade, GI pipe 40 mm dia for earthing lead to protect it from any mechanical damage/ injury including testing on completion complete all as per specified and as directed by Engineer-in-charge.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
Returning filling in soil including spreading, levelling, watering and well ramming in layers not exc. 25 cm complete all as per specified and as directed by Engineer-in-charge.
Supply and fix Heavy duty exhaust fan, AC, single phase 230/240V of size 300mm sweep, 1400RPM with louver on wall including cutting of hole on wall for fixing and finishing wall surfaces with the existing colour wash/white wash etc, complete all as per specified and as directed by Engineer-in-charge.
Taking out old existing CI water mains 80 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge.
Taking out old existing galvanised iron water mains 20 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge.
Taking out old existing galvanised iron water mains 50 mm bore (including all fittings) with spigot and socket ends and fittings for re-use in the work and removing unserviceable pipes and fittings from site complete all as per specified and as directed by Engineer-in-charge.
Laying only old serviceable galvanised iron water pipe of any grade 20 mm bore in trenches including cleaning of pipes as required and testing complete all as per specified and as directed by Engineer-in-charge.
Laying only old serviceable galvanised iron water pipe of any grade 50 mm bore in trenches including cleaning of pipes as required and testing complete all as per specified and as directed by Engineer-in-charge.
Supply and laying 3 layers PP-R Pipes 25 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
Supply and laying 3 layers PP-R Pipes 63 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
Supply and laying 3 layers PP-R Pipes 90 mm dia ( PN 16/ SDR 7.4) with all fittings laid in trenches including testing complete all as per specified and as directed by Engineer-in-charge.
S&F in repair gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 25 mm bore including taking down old unserviceable one, complete all as per specified and as directed by Engineer-in-charge.
S&F gun metal globe or gate valve, with iron wheel head screwed both ends for iron pipe of 25 mm bore complete all as per specified and as directed by Engineer-in-charge.
Supply and fix SP&N DBs, single door, 240 volt, 04 way, complete all as specified and as directed by Engineer-in-charge.
Supply and fix water heater geyser of capacity 25 Ltrs, BEE 5 star rated with puff insulation including all safety devices complete all as specified and as directed by Engineer-in-charge.
Supply & laying in trenches GI pipe 20 mm bore medium grade for protection of U/G cable complete all as specified and as directed by Engineer-in-charge.
Supply & laying in trenches GI pipe 25 mm bore medium grade for protection of U/G cable complete all as specified and as directed by Engineer-in-charge.
Cutting existing steel tubing for alterations or additions (Each cut measured) for pipe outer dia 25 to 32mm done in position without taking down complete all as specified and as directed by Engineer-in-charge.
Supply and fix fancy type, CP, bib tap of 20 mm size, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fix fancy type, CP, stop valves 20 mm, cast copper alloy, screwed dowd, high pressure with crutch or butterfly handle, swrewed both ends for iron or for unions and fixed complete all as specified and as directed by Engineer-in-charge.
Supply and fix hot and cold water pipe of length 900mm PVC connections 15mm size with PTMT nuts complete all as specified and as directed by Engineer-in-charge.
Supply, installation & commisioning of water cooler having partially stainless steel body, 120 Ltr storage capacity, 60 Ltr/hour cooling capacity, CFC-free refrigerant, single phase, electric driven, complete all as specified and as directed by Engineer-in-charge.
Supply and laying 3 layers PP-R Pipes 20 mm dia ( PN 16/ SDR 7.4) with all fittings fixed to walls, ceiling or in floors including testing complete all as per specified and as directed by Engineer-in-charge.
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc. for outer dia of pipe 16 to 40mm complete all as per specified and as directed by Engineer-in-charge.
Supply and fixing PP-R Gate valves (brass insert) suitable for PP-R pipe of outer dia 20mm complete all as per specified and as directed by Engineer-in-charge.
S&F Building security light fitting, energy saving new generation of 10W LED IP65 bulk head luminaire with opal diffuser complete with LED lamp of 10W LED 6000K complete all as per specified and as directed by Engineer-in-charge.
S&F Cast iron/pressed steel terminal boxes 60mm deep for mounting mounting of DBs with 3mm thick plastic laminated sheet cover of size 300 mmX250 mm complete all as per specified and as directed by Engineer-in-charge.
S&F PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 10 Sqmm 2 Core complete all as specified and as directed by Engineer-in-charge.
Supply and fixing stepped type, electronic ceiling fan regulator 120 watts piano type complete all as specified and as directed by Engineer-in-charge.
Supply and fix LED light fitting single tube 1 X 18 Watts, 240 V surface and wall mounted led batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with all accessories internally pre-wired and including connecting up with twine core twisted flexible copper contactor cable with 1.5M long suitable size, complete all as specified and as directed by Engineer-in-charge.
S&F PVC insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade having cross-sectional area 16 Sqmm 2 Core including taking down old unserviceable cable, complete all as specified and as directed by Engineer-in-charge.
Supply and fix angle type lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed by Engineer-in-charge.
Demolition of cement concrete in ground floors and pavings not exc. 15 cm thickness (below or above ground level) unreinforced complete all as specified and as directed by Engineer-in-charge.
M&L 40 mm thick PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in floor, finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge.
Dismantling Unframed timber scantlings 40 Sqcm and over in section and in any position complete all as specified and as directed by Engineer-in-charge.
Dismantling AC corrugated sheets as in roof covering complete all as specified and as directed by Engineer-in-charge.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-charge.
S&F Coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0. 11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) of size 300x200x6 mm thick on vertical surfaces such as dados, skirting, etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 10 mm thick screed bed in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) of size 300x200x6 mm thick on floor surfaces etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
Removing excvated materials (soils) exceeding 250m but not exc. 500.00 m and deposited where directed at a level not exc. 1.50 M above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
Removing excvated materials (soils) not exceeding 50m and depositing where directed at a level not exc. 1.50 m above the starting point in soil, complete all as specified and as directed by Engineer-in-charge.
M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete, complete all as specified and as directed by Engineer-in-charge.
M&L for Plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, etc., complete all as per specified and as directed by Engineer-in-charge.
S&F compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices, etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. Fe 410-W (Gde-E- 250) quality- A, complete all as per specified and as directed by Engineer-in-charge.
M&L for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161- 1979 grade St.-240, complete all as per specified and as directed by Engineer-in-charge.
M&L for plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment Fe 410-W (Gde-E- 250) quality- A, complete all as per specified and as directed by Engineer-in-charge.
S&F mild steel screw bolts with hexagonal or square heads at one end and screwed the other and screwed end to be fitted with washers, one nut exc. 30 cm long and dia of neck exc. 12mm & not exc. 20mm, complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as per specified and as directed by Engineer-in-charge.
S & F Chromium plated shower rose of 125 mm size with or without swivel joints, including fixing to steel pipe or union, complete all as per specified and as directed by Engineer-in-charge.
Taking up or down 15 mm bore steel tubing and connections, complete all as per specified and as directed by Engineer-in-charge.
S & F 15 mm bore Galvanized Steel tubes, medium grade water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as per specified and as directed by Engineer-in-charge.
S & F 20 mm bore Galvanized Steel tubes, medium grade water supply pipes etc., fixed to walls and ceilings or laid in floors complete all as per specified and as directed by Engineer-in-charge.
S&F Vitreous China wash down water closet pan 580 x 440 mm (Pedestal pattern) white complete including seat and cover, flush pipe incl all joints complete all as per specified and as directed by Engineer-in-charge.
S&F Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as per specified and as directed by Engineer-in-charge.
S&F 15mm dia bore pillar tap cast copper alloy with capston heads chroumium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as per specified and as directed by Engineer-in-charge.
S&F 15 mm bore chromium plated bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as per specified and as directed by Engineer-in-charge.
S&F solid PVC wall linning consisting of 5 mm thick single side prelam PVC sheetused instead of plain colour sheet inclusive of solvent cement and fixing at site as per specification and direted in any position complete all as per specified and as directed by Engineer-in-charge.
S&F 5mm thick PVC sheet fillets of width 35mm for wall paneling inclusive of fixing on wall to make frame complete all as per specified and as directed by Engineer-in-charge.
S&F second class hard wood plain fillets in rectangular or triangular in section, clean swan secured with screws or beads sectional area exc. 6 sqcm but not exc. 13 sqcm complete all as per specified and as directed by Engineer-in-charge.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as per specified and as directed by Engineer-in-charge.
S&F Anodised aluminium snap grid framed work for false ceiling all as specified with 4mm thick GI suspender complete all as per specified and as directed by Engineer-in-charge.
M & L for 4m thick Non Asbestos Cement E-board, designer type, fixed or laid/inserted to Alum frame work in ceiling complete all as per specified and as directed by Engineer-in-charge.
Demolition of reed lathing single or double including battens and plaster or chicken wire lathing complete all as per specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick wall of any description, including raking out joints, hacking for key, scrubbing down with water etc complete all as per specified and as directed by Engineer-in-charge.
G I Wire netting 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joists, etc., in walls, ceilings, stanchions, beams, etc., including all laps, cutting and waste complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick on brick or on one side of lathing in cement mortar 1:6 to be finished fair & even without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for second class hard wood in scantling wrought timber unframed complete all as per specified and as directed by Engineer-in-charge.
M&L for preparing surfaces of wood and wood based materials new or old of any description and girth, not otherwise described and treated with two coats of creosote oil complete all as per specified and as directed by Engineer-in-charge.
Surface dressing not exceeding 15cm deep in soft/loose soil including removing of bushes complete all as per specified and as directed by Engineer-in-charge.
M&L for brickwork with subclass 'B' brick straight and curvrd on plan to exc. 6 m mean radius built in 1:6 cement mortar complete all as per specified and as directed by Engineer-in-charge.
M&L for half brick thick brickwork with subclass 'B' brick straight and curvrd on plan to any radius built in 1:4 cement mortar complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as per specified and as directed by Engineer-in-charge.
M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete block surfaces finished even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
Supply only water proofing compound (integral) confirming to IS complete all as per specified and as directed by Engineer-in-charge.
M&L for rendering 15 mm thick with CM 1:6 on fair face of brick work or concrete surfaces including finishing even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for preparation of new plastered surface and applying two coats of cement base paint over one coat of primer on wall complete all as per specified and as directed by Engineer-in-charge.
M&L for three coats of white wash on new plastered surfaces including preparation of surfaces complete all as per specified and as directed by Engineer-in-charge.
M&L for hardcore of gauge not exc. 63mm, deposited, spread and levelling in layers not exceeding 15 cm thick, watered and rammed to true surface with broken stone or boulder complete all as per specified and as directed by Engineer-in-charge.
M&L for 75mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub-base complete all as per specified and as directed by Engineer-in-charge.
M&L for 75mm thick PCC (1:3:6 type C2) using 40mm graded stone aggregate in plinth protection, foot path and hard standing finished concrete surface even and smooth without using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for 25mm thick cement concrete 1:2:4 type B0 (using 12.50mm graded stone aaggregate) as in floor finished even and smooth using extra cement complete all as per specified and as directed by Engineer-in-charge.
M&L for vitrified ceramic tiles 10 mm thick of light shade (square/rectangular) polished area of each tile not exceeding 0.36 sqm in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM 1:6 complete all as per specified and as directed by Engineer-in-charge.
M&L for glazed coloured ceramic tiles of size (450mm x 300mm ) X 7 to 8mm thickness in vertical surface set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 15 mm thick screed bed or bedding layers in CM (1:6) complete all as per specified and as directed by Engineer-in-charge.
M&L for TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending and binding with M.S wire (annealed) not less than 0.9 mm dia or securing with clips complete all as per specified and as directed by Engineer-in-charge.
M&L for TMT bar 5mm dia and over upto and incl 8mm dia in stirrups cut to length, bent to shape required including cranking bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as per specified and as directed by Engineer-in-charge.
Supply, fabrication and fixing window of powder coated of extrusions Aluminium section two track with two sliding shutters with Frame 63.50mm x 38.40mm x 2mm thick, Two track bottom rail for sliding of shutters 61.98mm x 29.70mm, Top and side members for sliding shutters with Aluminium section of extrusions of 29.70mm x 61.58mm, Central rail for sliding inter lock shutter section size 39.00mm x 20mm, Top and bottom of sliding shutter extrusions size 20mm x 41mm, Side rail of sliding shutters handle section of size 20mm x 39mm, 5.5mm thick tinted/frosted/plain glass with rubber gasket of suitable size, colour of powder coating decided by EIC, all hardware also powder coated by same colour, complete all as specified and as directed by Engineer-in-charge.
M&L for anodised aluminium door shutters with powder coating of any colour (Thickness of powder coating not less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading, screws, etc. complete all as specified and as directed by Engineer-in-charge.
M&L for 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in square exc. 0.5 sqm in each pane, sheet glass is ground or obscured or frosted on one side complete all as specified and as directed by Engineer-in-charge.
M&L for 4mm thick Non-asbestos fibre cement Designer E-board ceiling of size (595x595) mm fixed in powder coated anodised aluminium frame (snapgrid) of standard section complete all as specified and as directed by Engineer-in-charge.
S&F pre-painted gavalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed by Engineer-in-charge.
S&F soild PVC Door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube, complete all as specified and as directed by Engineer-in-charge.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S tubes for top & bottom rails. M.S frame shall be covered with heat moulded plain colour PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and botom rail on either side & as gap insert for tip rail & bottom rails; panelling of plain colour PVC sheet to be fitted in the MS frame weloded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement. suppling and fixing in the frame at site complete all as specified and as directed by Engineer-in-charge.
S&F 15 mm bore stop valve, fancy type, chromimum plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed by Engineer-in-charge.
S&F grating doom 100 mm size of PTMT (min weight 25 grams) complete all as specified and as directed by Engineer-in-charge.
S & F PVC Connection of 15 mm size with PTMT nuts & of length 450mm complete all as specified and as directed by Engineer-in-charge.
S & F brass chromium plated tubular towel rail, 20 mm dia., D-type, 60 cm long between flanges complete all as specified and as directed by Engineer-in-charge.
S & F soap dish, vitreous China, white, of approximate size 160 x 160 x 90 mm complete all as specified and as directed by Engineer-in-charge.
S&F PVC valve-less, syphonic action type, flushing cistern, 10 Ltr capacity, low level, white with inlet ball valve float and handle including brackets including flush pipe complete all as specified and as directed by Engineer-in-charge.
S&F vitreous china squatting pan of pattern long pan, size 580 mm white with `P' or `S' trap, front or back inlet and foot rests any pattern including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including concrete complete including making good to floor complete all as specified and as directed by Engineer-in-charge.
S&F 32 mm dia waste coupling of PTMT (half or full threaded) complete all as specified and as directed by Engineer-in-charge.
S&F 32 mm dia low density polyethylene pipe (LDPE) of pressure rating @ 6Kgf per sqcm fixed to wall complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm dia. PVC (SWR) pipes single socketed, in any length, laid in trenches or in floors complete all as specified and as directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tank (cylinderical, vertical with closed top) of 1000 Ltrs capacity hoisted and fixed in position complete all as specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B1 (1:1.5:3) nominal mix (20mm graded stone aggregate) in foundation, including rafts, footing foundations beams, plinth beams, pile-caps, under reamed piles & mass concrete complete all as specified and as directed by Engineer-in-charge.
M&L for reinforced cement concrete type B-1 (1:1.5:3) nominal mix (using 20mm graded stone aggregate) as in column, pillar, post & struts complete all as specified and as directed by Engineer-in-charge.
M&L for formwork for foundation footing, pile caps, bases of columns, plinth beams & similar works on vertical or batter complete all as specified and as directed by Engineer-in-charge.
M&L for form work for side of pillars, posts, columns & similar works vertical or batter complete all as specified and as directed by Engineer-in-charge.
S&F rolled mild steel Fe-410-W (Gde-E-250 quality A) as in framed work for doors, gates or grill of angle or other section with gusset plates, rails, braces etc. complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with & including either hooks or hinges or steel hanging door fittings also fastening & fixing complete all as specified and as directed by Engineer-in-charge.
M&L for 15 mm thick screed bed or bedding layer of morter (1:6) for laying floor finishes complete all as specified and as directed by Engineer-in-charge.
M&L for 10 mm thick screed bed or bedding layer of morter (1:4) for vertical surfaces complete all as specified and as directed by Engineer-in-charge.
M&L for 18 to 20 mm thick granite (of any type) tiles, machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigmint to match the shade of granite stone including griding & polishing complete all as specified and as directed by Engineer-in-charge.
M&L for 18 to 20 mm thick granite (of any type) tiles in verticle surfaces such as skirting/dado, machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigmint to match the shade of granite stone including griding & polishing complete all as specified and as directed by Engineer-in-charge.
M&L for roughing surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and as directed by Engineer-in-charge.
M&L for brushing neat cement slurry with 3.00 kg of cement per sqm complete all as specified and as directed by Engineer-in-charge.
S&F coloured non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles complete all as specified and as directed by Engineer-in-charge.
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in skirting, dado, etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and as directed by Engineer-in-charge.
M&L for 100mm thick PCC type B 2 1:2:4 using (40mm gradded aggregate) as in sub base complete all as specified and as directed by Engineer-in-charge.
M&L for forming 12mm thick expansion joints filled with performed bituminous filler and top 30mm primed and sealed with sealing compound Grade ‘A’ for 100mm thick concrete floor complete all as specified and as directed by Engineer-in-charge.
M&L for construction of soakage well, excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM (1:4), RCC cover slab in M-25/SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M Dia X 3.00 M effective depth complete all as specified and as directed by Engineer-in-charge.
M&L for 1:3:6 type C-2 concrete bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed by Engineer-in-charge.
M&L for construction of manholes with 150 mm dia bore for connecting new drains making good to pipe, rendering, benching, forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished as required, ref drg No. CESZ/TD/40 complete all as specified and as directed by Engineer-in-charge.
M&L for excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc. 50 m and making good surface in hard/dence soil complete all as specified and as directed by Engineer-in-charge.
S&F Galvanised, corrugated mild steel 0.8mm thick sheeting with two corrugations side lap, fixed with J & L type hook bolts and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed by Engineer-in-charge.
M&L for surface excavation not exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles 300 x 450 x 7 mm thick, on vertical surfaces such as skirting, dados and risers to steps etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shades of tiles over 10 mm thick rendering layers in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L for mild steel TMT bar 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by Engineer-in-charge.
S&F 6 mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls etc complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of distemper oil emulsion over a coat of primer on surfaces of walls complete all as specified and as directed by Engineer-in-charge.
Fixing only for anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engineer-in-charge.
Fixing only for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed by Engineer-in-charge.
Fixing only for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed by Engineer-in-charge.
Dismantling of timber boarding of any description fixed in any position with nails complete all as specified and as directed by Engineer-in-charge.
S&F 20 mm thick second class hard wood boarding with butt joints clean sawn fixed with nails in any situation (except flooring and skirting) complete all as specified and as directed by Engineer-in-charge.
Taking down wooden shutters of any description exc. 1 but not exceeding 2 sqm each complete all as specified and as directed by Engineer-in-charge.
S&F 35 mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed by Engineer-in-charge.
S&F butt hinges 100 mm long medium weight, cold rolled mild steel complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and as directed by Engineer-in-charge.
S&F 150 mm long extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engineer-in-charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously untreated surfaces of wood and wood based surfaces of any description not other wise described of over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by Engineer-in-charge.
M&L for preparing new plastered surfaces and applying two coats of oil bound distemper on walls over 1 mm thick wall putty including one coat of chalk whiting primer complete all as specified and as directed by Engineer-in-charge.
M&L for complete removal of existing old distempared surfaces and applying two coat of oil bound distemper on walls over 1 mm thick wall putty including one coat of chalk whiting primer complete all as specified and as directed by Engineer-in-charge.
M&L for 4 mm thick asbestos cement plain building boards, fixed to timber frame work with screws as in ceiling complete all as specified and as directed by Engineer-in-charge.
M&L for 4 mm thick asbestos cement plain building boards, fixed to timber frame work with screws as in walls complete all as specified and as directed by Engineer-in-charge.
M&L for applying two coats of white wash incl preparation of AC wall board complete all as specified and as directed by Engineer-in-charge.
M&L for applying two coats of white wash incl preparation of AC ceiling board complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
RAJKAMAL ENTERPRISE
OM CONSTRUCTIONS
M/S NARAYAN ENTERPRISE
M/S MD ABDUL RAHMAT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .