| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC 1723 GUPTA AND SONS SECTOR 39 B CHANDIGARH CHANDIGARH CHANDIGARH 160036 UDYAM CH 01 0042756 | CHANDIGARH | CHANDIGARH | 160036 | ₹1.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 Cr+₹7.5 L (4.10%)Rejected-AOC | ₹1.9 Cr+₹7.5 L (4.10%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.0 Cr+₹15.4 L (8.42%)Rejected-AOC ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | ₹2.0 Cr+₹15.4 L (8.42%) | L3 | Rejected-AOC L3 |
| 4 | L4₹2.1 Cr+₹22.9 L (12.5%)Rejected-AOC | ₹2.1 Cr+₹22.9 L (12.5%) | L4 | Rejected-AOC L4 |
| 5 | L5₹2.1 Cr+₹24.5 L (13.4%)Rejected-AOC | ₹2.1 Cr+₹24.5 L (13.4%) | L5 | Rejected-AOC L5 |
Tender Value
₹2.4 Cr
EMD Value
₹3.2 L
Closing Date
18 Apr 2022, 6:00 pmClosed
SH AP SINGH, IDSE, CWE CHM
HQ CWE CHANDIMADNIR
CA NO CWE/CHM-87/2021-22 ADDN/ ALTN AND ALLIED WORK OF GARAGES FOR PARKING OF UNIT SPECIALIST VEH AND EQPTS AT CHANDIMANDIR MIL STN
2022_MES_514386_1
CWE/CHM-87/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
HQ CWE CHANDIMADNIR
Class B cat a(i)
9 documents required · 9 mandatory
₹2,000
Yes
GE CHANDIMADNIR
₹3.2 L
Yes
19 May 2022
19 Mar 2022
25 Apr 2022
19 Mar 2022
18 Apr 2022
11 Apr 2022
20 Mar 2022 - 29 Mar 2022
Amount
Demolition of Plain cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and as directed by Eng-in-Charge.
Hardcore broken stone or boulders of gauge n exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to true surface complete all as specified and directed.
50mm thick PCC (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified.
Reinforced cement concrete (RMC) (Design mix M-25) work as in pavement/ hard standing of thickness of concrete 25 cm or less with and incl necessary formwork and finished with spike rolling to surface or make impression of expanded metal, whilst the concrete in green complete all as specified and directed.
Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound Grade 'B' thickness of slab 200 mm complete all as specified and directed.
Machine cut kota stone slab flooring 18-20 mm thick over and including 15mm thick cement screed in CM 1:6 laid and jointed with grey cement slurry and pointed with grey cement pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
All as per ser No 06 herein before but on vertical surfaces as skirting over and including 10mm thick rendering in cement mortar 1:4.
60 mm thick pre polished rubber moulded factory made Machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment (Coloured ) confirming to IS 15658-2006, M-35 Grade, Size and pattern as approved by GE.
Sand filling under paver block including consolidation complete all as specified and directed
75 mm thick PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified and directed
Demolition of brickwork or stone boulder masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed.
Taking down chowkat or frames exc 1.5 Sqm but n exc 4 Sqm with shutters of any description (without taking off shutters from the frame) and removal from site complete all as specified and directed.
Pressed steel door frames of size 105mm x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with and including filling of PCC 1:2:4 type B0 using 12.5mm graded stone aggregate complete all as specified and directed.
Flush shutter 35 mm thick factory made solid core construction with block board core and ply wood face panels commercials type on both side complete all as specified and directed.
Aluminium handles cast type anodised of size 150mm long ISI marked complete all as specified.
150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified.
Butt hinges, 100mm size of mild steel with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
Factory made steel windows box type with side hung shutters including box type hinges, 125 mm size steel handle-02 Nos, mild steel ISI marked tower bolt 125 mm size minimum 2 nos for each shutter with and including necessary MS hold fasts complete with glazing bars, dovetailed or welded with and including a shop coat of red oxide primer including taking down old windows complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips complete all as specified and directed.
3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.
Taking down cement plaster from brick work concrete surfaces including raking out joints,hacking keys, scrubbing down with water etc. complete all as specified and directed.
10 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
15 mm thick rendering in cement mortar 1:4 with water proofing compound @ 2% by weight of cement on fair faces of brick wall or concrete surfaces finished even and fair without using extra cement complete all as specified and directed. Note : WPC will be measured and paid separately)
5 mm thick rendering in cement mortar 1:3 on ceiling finished even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed.
Preparation new plastered surfaces and applying two coats of cement base paint on new wall surfaces including all necessary wetting and curing complete all as specified and directed.
Applying three coats of white wash on wall of newly plastered surface incl perparation complete all as specified and directed.
Applying three coats of white wash on ceiling of newly plastered surface incl perparation complete all as specified and directed.
Preparation of old surface and applying two coats of white wash on ceiling complete all as specified and directed
Preparation of old surface and applying two coats of white wash on walls complete all as specified and directed
Preparation of old decorated surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Preparation of new steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint on Steel sheeting as in roofing complete all as specified.
All items as per Ser No 34 here-in-before but w/o priming with red oxide zinc chrome
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
Preparation of old painted steel surfaces of any description exc 10 cm width or girth and painting with two coats of synthetic enamel paint complete all as specified and directed.
110 mm bore PVC (SWR) rain water pipes single socketed in any length with rubber ring joints fixed to walls with and including M S clamps and making good the disturbed surface of wall with Cement mortar 1 :4 and including taking down existing U/S pipe of any description complete all as specified and directed.
110 mm bore PVC (SWR) bend for rain water pipes fixed to top & bottom of rain water pipe walls with and making good the disturbed surface with cement mortar 1:4 etc complete all as specified and directed.
Pre-painted galvalume aluminium zinc coating AZ-70 GI based corrugated steel sheet 0.50mm thick TCT of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating AZ-70 GI based plain steel sheet 0.50mm thick TCT of an colour having tensile strength of 550 Mpa as in roof in ridges, hips, facia boarding, valley gutters, drip and straight flashings (length and girth as fixed with grade of zinc coating) fixed with self tapping screws complete all as specified and as directed.
Roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming to Fe 410 -W (Gde E- 250) quality A complete all as specified and directed.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe 410-W (Gde-E 250 quality A) complete all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and directed.
Reinforced cement concrete RCC design mix M25 as in slab supported on walls, beams and col in floors, roofs and in shelves and the like complete all as specified and directed
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick complete all as specified and directed.
PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) , as in padding on RCC roof finished fair and even including demolition of existing PCC complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm garded crushed stone aggregate) as in seismic and other similar bands, hold fast, coping, benching and like incl necessary form work etc complete all as specified and directed.
PCC 1:2:4 type B0 ( using 12.5 mm graded crushed stone aggregate) as in kerbs or mud stops and similar work including necessary form work complete all as specified and directed.
Rendering 20mm thick in ratio 1:3 (cement and graded stone grits of size 6mm and below) on roof surfaces mixed with WPC @ 3% by weight of cement finished even and smooth using extra cement incl supply and fixing of chiken wire mess complete all as specified and directed (WPC will be measured and paid seperately). Note. Size of crushed graded stone aggregates shall be less than 6mm and more than 2.36mm.
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, The membrane shall be laid with 75mm side lap and 100mm end lap using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed.
M&L for taking down, chipping and removing the loose spailt, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforced cement concrete ,wire brushing and cleaning the exposed steel reinforced bar, applying rust remover over the cleaned re-bar surface, wash with clean water for removing all rusts from the old reinforcement bar surfaces, fixing new reinforcement, cut to lenghts, bend to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia for stregthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water, applying one coat of water, Nitbond or equivalent SBR (Latex) and cement in ratio (1:1:3) slurry as bond coat after that applying Nitbond or equivalent SBR (Latex), cement and quartz sand mortar in ratio (1:10:30) , 40 mm average thick in any number of coats, to provide at least 30mm thick cover to reinforcement finish the surfaces even and fair including erecting and dismantling steel scaffolding for carrying out the work upto height of 6m (approx) complete all as specified and as directed. Make : fosrock/Dr Fixit/ sunanda Note :- (i) New reinforcement will be measured and paid seperately (ii) Cost of fixing of new reinforcement by welding/ binding with old reinforcement and providing errecting or dismentling steel scaffolding shall deemed to be inclusive in quoted rates. (iii) Only crushed stone quartz sand shall be used for preparation of Nitbond or equivalent SBR (Latex), cement and quartz sand mortar.
Note :- A BOO shall be convened by Accepting Officer for passing the following stages for each portion of work under this item:- (i) Stage 1. Taking down/removing damaged cement concrete of RCC member, exposing and cleaning of exposed steel reinforcement, applying rust remover on old reinforced bar. (ii) Stage 2. Fixinig new MS steel TMT bars/ hard drawn steel wire fabric as per site requrement for strengthen the RCC member and applying two coats of eposy zinc primer on new of old steel surface. (iii) Stage 3. Applying one coat of water, Nitbond SBR (Latex) and cement in ratio (1:1:3) slurry as bond coat after that applying Nitbond SBR (Latex), cement and quartz sand mortar in ratio ( 1:10:30) , 40 mm average thickness in any number of coats, to provide at least 30mm thick cover to reinforcement.
Supply only hard drawn steel wire fabric weight per sqm n exc. 4 Kg completed all as specified and directed.
Supply only mild steel TMT bars of 10mm dia and over complete all as specified and directed.
M & L for mild steel TMT bars of 6 to 8mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, sockets, etc. removing materials to store for keeping in safe custody or for taking credit (credit for items should be made as per conditions seperately) and making good disturbed surfaces of walls, floors etc and removing materials from the site complete all as specified and directed.
Point wiring with PVC insulated unsheathed FRLSH 1100 volts grade single core muti stranded copper conductor cables of size 1.5 sqmm for phase & neutral in and including concealed PVC conduits, sheet steel sunken boxes1.2mm thickness covered inculding with 3mm thick plastic laminated sheet for mounting switches, scockets, regulator etc and including 1.5 Sqmm copper conductor PVC insulated and unsheathed multi stranded green cable as earth wire for one light point/fan point / buzzer point controlled by one switch complete all as specified and directed. (unit rate quoted including cutting chases wall/floor/pcc and making good the disturbed surface to match with the original. Nothing extra shall be paid on this account) complete all as specified and directed.
All as per item No 57 here-in-before but for one socket outlet 3pin, 5 Amps on the same board.
All as per item No 57 here-in-before but for one socket outlet 3pin, 5 Amps on the independent board.
All as per item No 57 here-in-before but for one socket outlet 3 pin, 15 Amps on independent board using cables of size 2.5 sq mm for phase & neutral and 2.5 sq mm as earth wire complete all as specified and directed.
Switch piano flush type, single pole, 230 volt one way , 5 Amps complete all as specified and directed.
Switch piano flush type, single pole, 230 volt one way , 15 Amps complete all as specified and directed.
Socket out let 2 in 1, 3 pin 5 Amps, ISI marked, 230 Volts complete all as specified and directed.
Socket out let 2 in 1, 5/15 Amps, ISI marked, 230 Volts complete all as specified and directed.
Ceiling rose 6 Amps three terminals complete all as specified and directed.
LED Light fittings 1x 20 watt , 220 volts, AC decorative box type with driver , holder including LED tubelight connecting up three core flexible copper conductor of suitable size from ceiling rose all as specified and directed.
LED light fitting 1x 9w / 1x 10 w bulkhead luminaire including LED Lightdriver holder connecting up with three core flexible copper conductor of suitable size all as specified and directed.
Disconnecting the power supply and taking down old unserviceable DBs/junction box/panels ect of any type and size complete along with all MCCBs/MCBs etc all as directed.
TPN distribution board double door flush mounting with provisions for MCBs TPN 4 way , 415 Volt having IP 43 protection complete all as specified and directed.
MCB TPN/FP 40-100 Amps 415 Volts having braking capacity 16 KA "C" characterstic complete all as specified and directed.
MCB DB, with provision for incoming 2 pole (MCB/Isolator) and single phase outgoing, suitable for surface and flush mounting, IP 43 protection, double door of metal 8 way complete all as specified and directed.
MCB SPN 32 Amp 230 Amps 240 Volts having braking capacity 10 KA "C" characterstic complete all as specified and directed.
MCB SP 6 to 32 Amps 240 Volts having braking capacity 10 KA "C" characterstic complete all as specified and directed.
Taking down carefully copper/aluminium sub main wiring complete, including existing batten/conduit etc., removing materials and making good disturbed surfaces of wall, floors, etc. complete all as specified and directed.
Sub main wiring (with approved colour coding as per IS) with two single core 6 sqmm FRLSH PVC insulated multistranded copper conductor cable 1.1 KV grade (main cable two runs of main cable) alongwith one run of single core 6 sqmm FRLSH PVC insulated flexible stranded copper donductor 1.1 KV grade of earth for earthing in and including PVC Concealed conduit minimum size 25 mm along with its accessories. (i) Cost of PVC Conduit & Cutting Chases for conduit and its accessories and making good for walls shall be deemed to be included in quoted rates. (ii) Colour code shall be Red for phase, black for neutral and green for earth. (iii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 running meter"
Earthing complete with galvanized steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm bore connected to main earth wire on pole light grade 20 mm bore connected to main earth wire on poleor control board or main switch and GI pipe medium grade 20mm bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:2:4 type B-1 20 mm graded stone aggregate excavation and earth work all as shown in electrical plate No 3 of MES Schedule part I of 2009 connected to earthing test point indicaed including testing on completion, complete all as specified and directed. Note : Cost for protection pipe and GI strip 32x6mm from top to earth plate up to 7.5 mete shall deemed to be included in quoted rates.
GI bracket made of GI pipe 'Light Grade' of size 40 mm dia 1.5 mtr length bend to shape of 120 degree fixed on pole/wall with clamp of size 50x6 of suitable length fixed with nuts/bolts and 1.5 sqmm 2 core flexible wire from conductor/ceiling rose to light fitting complete all as specified and directed.
LED building security light fittings 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver lamp bracket with impact and corrison resistant including thermal management in optical complete with IP 65/66 protection complete all as specified and directed.
XLPE cable Insulated heavy duty electric cable with aluminium conductor 1100 Volts cross sectional area 16 sqmm 4 core , complete all as specified and directed.
Excavation in trenches in hard/dense soil n. exc. 1.5m wide and n. exc. 1.5m in depth for laying of cables, poles, stay etc. and getting out complete all as specified and as directed.
Returning filling in including spreading, watering and well ramming in layers n.exc. 25 cm thick after the cable are laid and testsd complete all as specified and as directed.
Removal of surplus soil to a distance n. exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and as directed.
32 mm outer dia , double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Pt II with Anti Rodent and non flame propogating properties of approved color with fittings for cable protection from approval make complete all as specified and as directed.
aggarwal traders
NARINDER KUMAR SONS
shree balaji builders
Standard Const. Co.
Siya constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .