| 1 | L1₹46.6 LAdmitted-Finance B 163 SWARN JAYANTI PURAM GHAZIABAD GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | L1 | Admitted-Finance | |
| 2 | No RankAdmitted-Finance 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | No Rank | Admitted-Finance | |
| 3 | No RankAdmitted-Finance CRYSTAL TOWER 4TH FLOOR TELIBANDHA RAIPUR | RAIPUR | RAIPUR | CHHATTISGARH | No Rank | Admitted-Finance | |
| 4 | No RankAdmitted-Finance 307 SWAIKA CENTRE 4A POLLOCK STREET KOLKATA 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | No Rank | Admitted-Finance | |
| 5 | No RankAdmitted-Finance UNIT NO 12 4 MERLIN ACROPOLIS 12TH FLOOR 1858 1 RAJDANGA MAIN ROAD KOLKATA 700107 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700107 | No Rank | Admitted-Finance |
| Sl No | Description | Qty | Unit | LASER POWER AND INFRA PVT. LTD No Rank | Montecarlo Limited No Rank | Lumino Industries Limited No Rank | CAPITAL ELECTECH PVT LTD L1 | Jakson Limited No Rank | LARSEN AND TOUBRO LIMITED No Rank |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply for ( 2 X 5 MVA) New 33/11 KV Substation- SCADA Compatible as per technical specifications, scope of works and approved drawings | |||||||||
| 1.01 | Supply & installation, testing and commissioning of 5 MVA Power Transformer | 22 | No. | - | - | - | 12,88,28,634 ₹10,06,786 Lowest | - | - |
| 1.02 | Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level. | 22 | No. | - | - | - | 0 ₹36,49,580 Lowest | - | - |
| 1.03 | Supply & Erection of 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminium wound,(Energy Efficiency Level-1) CRGO core, outdoor type Station Transformer Completely filled with transformer oil as per technical specifications. | 11 | No. | - | - | - | - | - | - |
| 1.04 | Supply & Erection of hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS for all structural members. As per TS | 66 | MT | - | - | - | - | - | - |
| 1.05 | Gantry Foundation | 44 | Cum. | - | - | - | - | - | - |
| 1.06 | Supply & Erecrion of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure. | 34 | No. | - | - | - | - | - | - |
| 1.07 | Construction of Plinth & foundation for 33 kv VCB | 34 | No. | - | - | - | - | - | - |
| 1.08 | Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect. | 12 | Set | - | - | - | - | - | - |
| 1.09 | Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect. | 22 | Set | - | - | - | - | - | - |
Tender Value
₹564.8 Cr
EMD Value
₹5 Cr
Closing Date
15 Oct 2024, 4:00 pmClosed
CE REVAMPED
MD Office PuVVNL Bhikharipur Varanasi 221004
Modernization Work under RDSS
2024_PVVNV_941804_2
EAV-08/24-25
Open Tender
Electrical Works
Turn-key
730 days
Varanasi
Please refer Tender documents.
4 documents required · 4 mandatory
₹29,500
Administrative Officer for MD Office
₹5 Cr
16 Nov 2024
30 Sept 2024
16 Oct 2024
30 Sept 2024
15 Oct 2024
30 Sept 2024
30 Sept 2024 - 2 Oct 2024
Supply for ( 2 X 5 MVA) New 33/11 KV Substation- SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply & installation, testing and commissioning of 5 MVA Power Transformer
Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level.
Supply & Erection of 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminium wound,(Energy Efficiency Level-1) CRGO core, outdoor type Station Transformer Completely filled with transformer oil as per technical specifications.
Supply & Erection of hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS for all structural members. As per TS
Gantry Foundation
Supply & Erecrion of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Construction of Plinth & foundation for 33 kv VCB
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Construction of Plinth & foundation for 33 kV Single Phase CT (3 Nos.)
Supply & Erection of 36 kV, 1-Phase, 33kV/110 volt, Single core outdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no) As per TS
Construction of Plinth & foundation for 33 kV Single PT (3 Nos.)
36kV, indoor, Control & Relay panel along with E/F & O/C, Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS:
Supply & Erection of 33 kV feeder Panel (without diffirential relays) complete As per TS.
Supply & Erection of 33 kV Double Transformer Panel (with diffirential relay and 5/1 A auxillary CT) complete As per TS .
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch)
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch)
Construction of Plinth & foundation for 33 kV isolator
Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.)
Construction of Plinth & foundation for 33 kV LA
Supply & Erectionof of 9kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 Set = 3 Nos.)
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for Incomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase ,with Numerical Relays & accessories complete as per specifications for transformer breaker protection with earth fault, overcurrent .
Supply & Erection of 12 kV, 1600 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protection with earth fault, overcurrent .
Supply & Erection of 12 KV 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
Supply & Erection of 24V, 150 AH Pb(Lead) Acid battery,with cabinet specifications.
Supply & Erection of 24V, 150 AH. Float-cum-Boost Battery Charger for 230 V, 1 phase, 50 Hz AC Input Supply as per technical specifications.
Supply & Erection of 24V DCDB complete in all respect suitable for 20 nos. of DC circuit for smooth operation of DC supply as per technical specifications.
Supply & Erection of 415V AC Distribution Board/Panel of sheet steal enclosed cubical floor mounting type for catering auxiliary power supply for Suitable 100 KV T/F of the substaion etc. complete
Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations
Earthing & Grounding conductor as per Approved Electrical Layout for each sub- station with
Supply & Erection of 75 x 8 mm GI flat.
Supply & Erection of 50 x 6 mm GI flat.
Supply & Erection of 32 mm dia MS rod 6 m long for earth mat
Supply & Erection of 40 mm dia., 3000 mm long GI pipe earth electrode as per Technical Specification
33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shall be MS hot dip galvanised)
Supply & Erection of 33 KV Post Insulator (1 Set = 2 Nos of 22 KV)
Construction of Plinth & foundation for 33 kV Post Insulator
Supply & Erection of 33 KV Disc Insulator Insulator (1 Set = 4 Nos Disc Insulator 70 KN)
Supply & Erection of Hardware fitting for 33 KV Disc Insulator (B&S Type 70 KN)
Supply & Erection of 33 KV Polymer Pin Insulator with Nut & Bolt .
Supply & Erection of Bimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required.
Supply & Erection of Station Lighting System (External) 120 Watt, LED with proper illumination complete for switchyard, main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room building )
Supply & Erection of Station Lighting System (internal) with proper illumination complete for control room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc. including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. and Celling Fan , wall Fan & exhaust fan (Total 8 nos.) all complte as per applicable TS and approved drawing.
Supply of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide Wrench 8" & 12" 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth Tester - 1 no, Insulation Megger (hand operated) 2500 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 2 Sets, Rubber mat (1.25" Thick) for laying in front of all panels in control room completely
Supply & Erection Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for control room, CO 2 Type of 4.5Kg Capacity 4 nos for Control Room, Fire buckets with Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings
11 KV, XLPE, Power cable, aluminium conductor, stranded
Supply of 11 kv 3Cx 300 sqmm (armoured) Cable
Supply of 11 kv 3Cx 185 sqmm (armoured) Cable
Supply of 11 kv 3Cx70 Sqmm (armoured) Cable
Laying of 11 KV U/G cable includnig cost of sand and bricks
Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor
Control Cable
Supply of 4x2.5 mm sq.
Supply of of 2x2.5 mm sq.
Supply of LT Power Cable 3.5Cx95 sq. mm .
Laying of Control Cable
Furniture items as required
Office table Godrej make
Office chair Godrej make
Godrej Storwel (Almirah) standard size.
11kV Feeder Double Pole structure on 11kV STP alongwith fitting
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP- (410 SP 55).
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of Barbed wire
Supply & Erection of Danger Board
Suplly & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt.
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
Supply & Erection of S/S name board (SMC) with stand.
Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS
Earth work by mechanical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil
Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil :
Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth.
Deduct for not watering the excavated earth for banking
Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
First class brick laid dry in foundation and plinth as in circular soakpit walls of one brick thickness and 2.0 to 3.0M depth including cutting moulding bricks as required including cost of all materials labour and T&P complete.
S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) .
Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge.
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3)
Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4)
S/F Angle/Batten Holder.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)(DSR E&M 2022 1.27.2)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6)
S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit.
Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6)
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1)
Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make
Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.
S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12)
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required for proper completion of work.
Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. (CSI No. 19.28)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Providing and fixing of 150 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25)
Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work.
Supply and fixing of 110mm dia PVC. bail plug of heavy quality including all labour material & T&P.
Supply and fixing of 160mm dia PVC top plug of heavy quality including all labour material & T&P.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31) a) for 1 HP pump set single phase
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. c)110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etc required for proper completion of the work c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Coupler including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Supply of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel)
Supply & Erection of 12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel , Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumunium wound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No.
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit outoor(1.98 MVAr HT Capacitor bank)
Supply & Erection 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(1.98 MVAr HT Capacitor bank)
Casting of Civil foundation(1.98 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank)
Supply for ( 1X 10 MVA) New 33/11 KV Substation- SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply &installation, testing and commissioning of 10 MVA Power Transformer
Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level.
Supply & Erection of 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminium wound, CRGO core, outdoor type Station Transformer Completely filled with transformer oil as per technical specifications.( Energy Efficiency Level-1)
Supply & Erection of hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS for all structural members. As per TS
Gantry Foundation
Supply & Erection of GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS.
Supply & Erecrion of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Construction of Plinth & foundation for 33 kv VCB
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Construction of Plinth & foundation for 33 kV Single Phase CT (3 Nos.)
Supply & Erection of 36 kV, 1-Phase, 33kV/110 volt, Single core outdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no)
Construction of Plinth & foundation for 33 kV Single PT (3 Nos.)
36kV, indoor, Control & Relay panel along with E/F & O/C, Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS:
Supply & Erection of 33 kV feeder Panel (without diffirential relays) complete.
Supply & Erection of 33 kV Transformer Panel (with diffirential relay and 5/1 A auxillary CT) complete.
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch)
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch)
Construction of Plinth & foundation for 33 kV Isolator
Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.)
Construction of Plinth & foundation for 33 kV LA
Supply & Erectionof of 9kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 Set = 3 Nos.)
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for Incomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , with Numerical Relays & accessories complete as per specifications for transformer breaker protection with earth fault, overcurrent .
Supply & Erection of 12 KV 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
Supply & Erection of 24V, 150 AH Pb(Lead) Acid battery,as per technical specifications.
Supply & Erection of 24V, 150 AH. Float-cum-Boost Battery Charger with full wave rectification for 230 V, 1 phase, 50 Hz AC Input Supply as per technical specifications.
Supply & Erection of 24V DCDB complete in all respect suitable for 20 nos. of DC circuit for smooth operation of DC supply as per technical specifications.
Supply & Erection of 415V AC Distribution Board/Panel of sheet steal enclosed cubical floor mounting type for catering auxiliary power supply for Suitable 100 KV T/F of the substaion etc. complete
Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations
Earthing & Grounding conductor as per Approved Electrical Layout for each sub- station with
Supply & Erection of 75 x 8 mm GI flat.
Supply & Erection of 50 x 6 mm GI flat.
Supply & Erection of 32 mm dia MS rod 6 m long for earth mat
Supply & Erection of 40 mm dia., 3000 mm long GI pipe earth electrode as per Technical Specification
33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shall be MS hot dip galvanised)
Supply & Erection of 33 KV Post Insulator (1 Set = 2 Nos of 22 KV)
Construction of Plinth & foundation for 33 kV Post Insulator
Supply & Erection of 33 KV Disc Insulator Insulator (1 Set = 4 Nos Disc Insulator 70 KN)
Supply & Erection of Hardware fitting for 33 KV Disc Insulator (B&S Type 70 KN)
Supply & Erection of 33 KV Polymer Pin Insulator with Nut & Bolt .
Supply & Erection of Bimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required.
Supply & Erection of Station Lighting System (External) 120 Watt, LED with proper illumination complete for switchyard, main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room )
Supply & Erection of Station Lighting System (internal) with proper illumination complete for control room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc. including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing.
Supply & Erection of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8" & 12" 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25" Thick) for laying in front of all panels in control room completely
Supply & Erection Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for control room, CO 2 Type of 4.5Kg Capacity 4 nos for Control Room, Fire buckets with Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings
11 KV, XLPE, Power cable, aluminium conductor, stranded
Supply of 11 kv 3Cx 300 sqmm (armoured) Cable
Supply of 11 kv 3Cx 185 sqmm (armoured) Cable
Supply of 11 kv 3Cx70 Sqmm (armoured) Cable
Laying of 11 KV U/G cable includnig cost of sand and bricks
Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor
Control Cable
Supply of 4x2.5 mm sq.
Supply of of 2x2.5 mm sq.
Supply of LT Power Cable 3.5Cx95 sq. mm.
Laying of Control Cable
11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9)
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Suplly & Erection of 11KV TPMO switch with fixing clamps
Suplly & Erection Barbed wire
Suplly & Erection of Danger Board
Supply & Erection of 11 KV fuse set with fixing clamps
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
Supply & Erection of S/S name board (SMC) with stand.
Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS
Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil
Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil :
Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth.
Deduct for not watering the excavated earth for banking
Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
First class brick laid dry in foundation and plinth as in circular soakpit walls of one brick thickness and 2.0 to 3.0M depth including cutting moulding bricks as required including cost of all materials labour and T&P complete.
S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) .
Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge.
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3)
Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4)
S/F Angle/Batten Holder.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)(DSR E&M 2022 1.27.2)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6)
S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit.
Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6)
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1)
Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make
Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.
S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12)
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required for proper completion of work.
Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. (CSI No. 19.28)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Providing and fixing of 150 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25)
Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work.
Supply and fixing of 110mm dia PVC. bail plug of heavy quality including all labour material & T&P.
Supply and fixing of 160mm dia PVC top plug of heavy quality including all labour material & T&P.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31) a) for 1 HP pump set single phase
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. c)110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etc required for proper completion of the work c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Coupler including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
3.96 MVAr With APFC Panel As per TS
Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/s housed in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(3.96 MVAr HT Capacitor bank)
Casting of Civil foundation(3.96 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank)
Supply for ( 2X 10 MVA) New 33/11 KV Substation- SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply & installation, testing and commissioning of 10 MVA Power Transformer
Construction of Power Transformer Plinth of size 3.46x4.46 Mtr. having 0.5 Mtr. below ground level and 0.4 Mtr. above ground level.
Supply & Erection of 63 KVA, 11/0.415 kV, 3 ph, 50 Hz, ONAN,Aluminium wound, CRGO core, outdoor type Station Transformer Completely filled with transformer oil as per technical specifications. Energy Efficiency Level-1
Supply & Erection of hot dip Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. Anchor plate shall be of relevant IS
Gantry Foundation
Supply & Erection of GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanized as per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS
Supply & Erecrion of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Construction of Plinth & foundation for 33 kV VCB.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 200-100/1-1 Amps ( having 2 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Construction of Plinth & foundation for 33 kV CT .
Supply & Erection of 36 kV, 1-Phase, 33kV/110 volt, Single core outdoor type Potential Transformer including accessories etc., complete as per technical specifications.( 1 set=3 no)
Construction of Plinth & foundation for 33 kV PT
36kV, indoor, Control & Relay panel along with E/F & O/C, Mimic Diagram,Voltmeter, Ammeter, Annunciation Windows with annunciation relays and other components etc. complete as per approved drawings & TS:
Supply & Erection of 33 kV feeder Panel (without diffirential relays) complete.
Supply & Erection of 33 kV Double Transformer Panel (with diffirential relay and 5/1 A auxillary CT) complete As per TS.
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch)
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch)
Construction of Plinth & foundation for 33 kV Isolator .
Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.)
construction of Plinth & foundation for 33 kV LA
Supply & Erection of of 9kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 Set = 3 Nos.)
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for Incomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , Numerical Relays & accessories complete as per specifications for transformer breaker protection with earth fault, overcurrent .
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protection with earth fault, overcurrent .
Supply & Erection of 12 KV 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
Supply & Erection of 24V, 150 AH Pb(Lead) Acid battery As per TS.
Supply & Erection of 24V, 150 AH. Float-cum-Boost Battery Charger for 230 V, 1 phase, 50 Hz AC Input Supply as per technical specifications.
Supply & Erection of 24V DCDB complete in all respect suitable for 20 nos. of DC circuit for smooth operation of DC supply as per technical specifications.
Supply & Erection of 415V AC Distribution Board/Panel of sheet steal enclosed cubical floor mounting type for catering auxiliary power supply for Suitable 100 KV T/F of the substaion etc. complete
Supply & Erection of ACSR Panther Conductor for Bus-Bars & Jumpers/Droppers/Terminations
Earthing & Grounding conductor as per Approved Electrical Layout for each sub- station with
Supply & Erection of 75 x 8 mm GI flat.
Supply & Erection of 50 x 6 mm GI flat.
Supply & Erection of 32 mm dia MS rod 6 m long for earth mat
Supply & Erection of 40 mm dia., 3000 mm long GI pipe earth electrode as per Technical Specification
33 KV and 11 KV Insulator - Pin, Post and Disc insulators along with G.I. Pin, Hardware & Accessories suitable for Panther conductors as per Technical secifications(All the materials shall be MS hot dip galvanised)
Supply & Erection of 33 KV Post Insulator (1 Set = 2 Nos of 22 KV)
Construction of Plinth & foundation for 33 kV Post Insulator
Supply & Erection of 33 KV Disc Insulator Insulator (1 Set = 4 Nos Disc Insulator 70 KN)
Supply & Erection of Hardware fitting for 33 KV Disc Insulator (B&S Type 70 KN)
Supply & Erection of 33 KV Polymer Pin Insulator with Pin
Supply & Erection of Bimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required.
Supply & Erection of Station Lighting System (External) 120 Watt, LED with proper illumination complete for switchyard, main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room )
Supply & Erection of Station Lighting System (internal) with proper illumination complete for control room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc. including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing.
Supply of Tool & Plant: Gum Boot- 2 pair, Hand Gloves- 2 pair, Insulated Plier- 2 nos., D E spanner set- 2 sets, Slide range 8" & 12" 2 nos each, Torch (Flash Light) 4 cell- 2 nos, Earth megger- 1 no, Insulation Megger (hand operated) 1000 V-1 no, Tong Tester (Digital)- 1 no, Discharge Rod (1 Set=3 Nos)- 6 Sets, Rubber mat (1.25" Thick) for laying in front of all panels in control room completely
Supply Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for control room, CO 2 Type of 4.5Kg Capacity 4 nos for Control Room, Fire buckets with Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings
11 KV, XLPE, Power cable, aluminium conductor, stranded
Supply of 11 kv 3Cx 300 sqmm (armoured) Cable
Supply of 11 kv 3Cx 185 sqmm (armoured) Cable
Supply of 11 kv 3Cx70 Sqmm (armoured) Cable
Laying of 11 KV U/G cable includnig cost of sand and bricks
Heat Shrinkable jointing kit suitable for 11 kV XLPE 3x300 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x300 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x185 Sq. mm. XLPE Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x70 Sq.mm. cable size
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE outdoor
Supply & Erection of Heat Shrinkable jointing kit for 11 kV 3x70 Sq. mm. XLPE Indoor
Control Cable
Supply of 4x2.5 mm sq.
Supply of of 2x2.5 mm sq.
Supply of LT Power Cable 3.5Cx95 sq. mm.
Laying of Control Cable
11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9)
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of Barbd wire
Supply & Erection of Danger Board
Suplly & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt.
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
Supply & Erection of S/S name board (SMC) with stand.
Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS
Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil
Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil :
Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth.
Deduct for not watering the excavated earth for banking
Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
First class brick laid dry in foundation and plinth as in circular soakpit walls of one brick thickness and 2.0 to 3.0M depth including cutting moulding bricks as required including cost of all materials labour and T&P complete.
S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) .
Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge.
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3)
Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4)
S/F Angle/Batten Holder.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)(DSR E&M 2022 1.27.2)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6)
S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit.
Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6)
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1)
Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make
Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.
S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12)
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required for proper completion of work.
Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. (CSI No. 19.28)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Providing and fixing of 150 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25)
Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work.
Supply and fixing of 110mm dia PVC. bail plug of heavy quality including all labour material & T&P.
Supply and fixing of 160mm dia PVC top plug of heavy quality including all labour material & T&P.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31) a) for 1 HP pump set single phase
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. c)110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etc required for proper completion of the work c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Coupler including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
3.96 MVAr With APFC Panel As per TS
Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/s housed in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(3.96 MVAr HT Capacitor bank)
Casting of Civil foundation(3.96 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank)
Supply for New 33/11 KV Indoor GIS Type Substation- SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply & installation, testing and commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS
Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS ( On As it is where it is basis)
Supply & Erection of 33 KV GIS Panels with 2 line bays, 2 transformer bays, 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required.
Supply & Erection of 11 KV GIS Panels with 6 line bays, 2 transformer bays, 1 station transformer bay & 1 bus coupler bay, Bus PT, all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section.
Supply & Erection of 24 V, 150AH,Pb(Lead) Acid type battery set scomplete.
Supply & Erecion of Float-cum-boost battery charger (SMPS based ) with full wave , full control rectification, 50Hz input voltage for charging 24V, 150 AH Battery alongwith DCDB, connectors etc. complete and connection with 24 V , 150 AH Battery set and single phase AC input supply.
Supply & Erection of 415V AC Distribution Board/Panel of sheet steal enclosed cubical floor mounting type for catering auxiliary power supply of the substaion etc. complete
Supply & Erection of 63KVA, 11 kV/0.415 kv Station Transformer alongwith all accessories as per TS.Energy Efficiency Level-1
Supply & Erection of 40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS.
Supply & Erection of 75x6 mm Galvanized flat for raiser for earthing as per TS
Supply & Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS.
Supply & Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS.
Supply & Laying of 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 1 Run) with cable tray.
Supply & Laynibg of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 2 Run) with cable tray.
Suppy & Laying of LT Power Cable 3.5Cx95 sq. mm.
Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items
Supply & Laynibg of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items
Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items
Supply of Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for control room, CO 2 Type of 4.5Kg Capacity 4 nos for Control Room, Fire buckets with Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings
Supply of Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik
Supply & Erection of 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm
Supply & Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming)
Supply & Erection of 11KV XLPE Cable (3x300 sq.mm.) Heat Shrinkable Jointing kit outdoor
Supply & Erection of 33KV XLPE Cable (3x400 sq.mm.) Heat Shrinkable Jointing kit outdoor
Supply & Erection of Complete lighting system for control room building,main gate and substation boundary including fans as per detailed Technical Specifications.
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of Barbd wire
Supply & Erection of Danger Board
Suplly & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt.
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
Civil works: Design, supply of all material, T&P, labour etc for the following civil works complete as per TS
Earth work by mechinical / manual means in rough excavation, banking excavated earth in layers not exceeding 20cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead upto 50 m and for all lift :All kinds of soil
Banking excavated earth by mechanical / manual means in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and for all lift All kinds of soil :
Deduct for not rolling with power roller of minimum 8 tonnes for banking excavated earth in layers not exceeding 20 cm in depth.
Deduct for not watering the excavated earth for banking
Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
CEMENT CONCRETE (CAST IN SITU) Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CAST IN SITU :- Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Foundations, footings, bases of columns, etc. for mass concrete
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Columns, Pillars, Piers, Abutments, Posts and Struts
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Edges of slabs and breaks in floors and walls, Under 20 cm wide
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for,Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
FORM WORK:- Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto & above to plinth level.
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement : 4 coarse sand)
First class brick laid dry in foundation and plinth as in circular soakpit walls of one brick thickness and 2.0 to 3.0M depth including cutting moulding bricks as required including cost of all materials labour and T&P complete.
S/Filling brick bats including supply of material labour T&P etc. complete ( based on materials rates +10% contracor profit).
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, priming coat of approved steel primer, but excluding the cost of other fittings,glass panes complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only) .
Placing of Trench Cover of all sizes in proper position including transportation from different places within the s/s area including all labour, T&P etc. required for proper complection of the work as per direction of Engineer-in- charge.
Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives. New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C (DSR E&M 2022 1.10.3)
Wiring Point for Plug with 1.5 sq. mm. PVC insulated single core copper conductor cable in heavy guage rigid PVC conduit pipe concealed in the wall, complete with 1.5 Sq mm multistand copper earth continuity wire with piano type switch & ceiling rose/angle/batten holder on 3mm. thick phenolic laminated backlite sheet etc. complete in all respect, as directed including matching colour wash as.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet (DSR E&M 2022 1.24.4)
S/F Angle/Batten Holder.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)(DSR E&M 2022 1.27.1)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm)(DSR E&M 2022 1.27.2)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)(DSR E&M 2022 1.27.3)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)(DSR E&M 2022 1.27.4)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)(DSR E&M 2022 1.27.5)
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)(DSR E&M 2022 1.27.6)
S/wiring Sub main with 2 No. 16sq mm PVC insulated 1100v grade single multistand single core copper conductor cable in 20mm dia heavy gauage PVC condut concealed with wall including one number 2.5 sqmm FR PVC insulated multistand copper cable as earth contuity wire drawn in conduit.
Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED light fitting including tube on Surface complete in all respect.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.(DSR E&M 2022 5.6)
Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR E&M 2022 2.5.1)
Supply and fixing of 50Amps to 63 Amps MCB 9KA/10KA HAVELLS or equivalent make
Supply and fixing of 63A 240 volts I.C. Cut out of approved make on the metre board or polished MDFEG/Teak ply board. Complete in all respect.
Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.
S/F of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. Box of 175mm x 100mm x50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.(DSR E&M 2022 1.12)
Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Supply and Fixing of 3 blade ceiling fan 1200 mm of Havells or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge.
Cleaning and dressing of site for tube well boring including cost of all labour, materials and T&P required for proper completion of work.
Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc. (CSI No. 19.28)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia
Providing and fixing of 150 mm dia PVC pipe of 6 Kg/sqcm with special such as Tee, bend, socket, elbow etc including supply of all labour,material,T & P etc complete required for proper completion of work. (CSI No. 26.25)
Providing 110mm dia Slotted PVC CASING PIPES (Aroma /Supreme) (Pressure10 Kg./ Sqcm.) for making tubewell assembly and cartage to boring site, including cost of all labour, materials and T&P required for assembly making and proper completion of work.
Supply and fixing of 110mm dia PVC. bail plug of heavy quality including all labour material & T&P.
Supply and fixing of 160mm dia PVC top plug of heavy quality including all labour material & T&P.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 150 mm clamp
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. (CSI No. 19.34)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 40 mm nominal bore, 206mm long, weighing not less than 690 gms
Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. (CSI No. 19.32) a) 1 HP outlet 32 mm dia. or more, Head 78/30,Discharge 1100/2800 LPH
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. (CSI No. 19.31) a) for 1 HP pump set single phase
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
S/F of 2.5 sq. mm 3 core P.V.C. sheathed P.V.C. insulated water proof ISI marked, flat flexible copper cable of BEST or other equivalent make, for 1HP and up to 3HP submersible pump sets, complete in all respect.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 30cm length
Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 25mm nominal bore, weighing not less than 62 gms
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet , Sand cast iron S&S as per IS: 3989
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in reinforced cement concrete slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Bends including cost of all materials, labour and T&P etc required for proper completion of the work. c)110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Socket including cost of all materials, labour and T&P etc required for proper completion of the work c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Coupler including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) plain Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door Tee including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Providing and fixing SWR, PVC ( Finolex or equivalent ) Door “Y” including cost of all materials, labour and T&P etc required for proper completion of the work. c) 110 mm dia.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
Contouring of sub-station with help of leveling instrument/ total station instrument & staff including plotting of trees and structure if any including preparation of contour plan in 6 copies including marking periphery including all labour, Supervisor, instrument, T&P materials complete as per direction of Engineer I/C.
Undisturbed soil samples collected in field will be tested in Laboratory and preparation of samples for tests mentioned below, will be done/governed in accordance with IS 2720 (Part 1)-1983,i) Tri axial compression test and determination of shear parameters(c & ) as per ISS –2720 (Part ix) ISS 2720-(Part xii) ISS 2720-(Part xiii) on silty/sandy soil .Consolidation Test as per ISS-2720( Part xv )on clay soil,ii) Sieve analysis test as per ISS 2720 (Part iv),iii) Atterberg’s limit tests as per ISS –2720 (Part v).iv) Particle size analysis test as per ISS 2720 (Part iv),v) Natural moisture content test as per ISS 2720 (Part vi),vi) Wet density test and dry density test as per ISS 2720 (Part vi),vii) Specific gravity test as per ISS 2720 (Part iii) section 2,Disturbed soil samples will be prepared in accordance with ISS 2720 (Part I) 1983 and tested as follows,i) Sieve analysis test as per ISS – 2720 (part iv),ii) Atterberg’s limit tests as per ISS- 2720(Part v)
Augmentationl Power Transformers( 5 to 10 MVA) SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply &installation, testing and commissioning of 10 MVA 33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS
Supply & Erectoion of MS Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. Anchor plat shall be of relevant IS
GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanized as per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS
Supply & Erection of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Construction of Plinth & foundation for 33 kV VCB
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 200-100/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications.
Supply & Erection of 33 kV Single Transformer Panel (with diffirential relay and 5/1 A auxillary CT) complete As per TS .
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for Incomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type 3 core Current Transformer, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , Numerical Relays & accessories complete as per specifications for transformer breaker protection with earth fault, overcurrent .
Supply & Erection of 12 KV, 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
11 KV, XLPE, Power cable, aluminium conductor, stranded
Supply of 3Cx 300 sqmm (armoured)
Supply of 3Cx 185 sqmm (armoured)
Laying of 11 KV U/G cable includnig cost of sand and bricks
Cable termination kit suitable for termination in transformer cable box/ breaker panel/ outdoor 11 KV terminals complete with all accessories etc
Supply & Erection Termination kit 3Cx 300 sqmm outdoor
Supply & Erection Termination kit 3Cx 300 sqmm indoor
Supply & Erection of Termination kit 3Cx 185 sqmmoutdoor
Supply & Erection of Termination kit 3Cx 185 sqmm Indoor
Control Cable
Supply of 4x2.5 mm sq.
Supply of of 2x2.5 mm sq.
Laying of Control Cable
Dismantaling &Transportation from existing site to Store, Installation, Erection, Testing and Commisiioning of 5/8 MVA Power Transformers with suitable Clamps, Connectors, bolts nuts and washers of Brass etc as required with 2 sets each of body & neutral earthing with 50x8 mm GS Strip as per TS completely required for commissioning.
Modification of existing Power Transformer foundation required for installation and commissionig of augmented 5/10 MVA Power Transformers completely as per TS. (As per requirement)
Additional 5 MVA & 10 MVA Power Transformers SCADA Compatible as per technical specifications, scope of works and approved drawings
Supply &installation, testing and commissioning of 5 MVA Power Transformer
Supply &installation, testing and commissioning of 10 MVA Power Transformer
Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS ( On As it is where it is basis)
Construction of Plinth & FoundationFoundation for 5 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS ( On As it is where it is basis)
Supply & Erectoion of MS Galvanised structures (all Type) made of joist / channel / angle / flat of different sections as per approved drawings. All structural steel members shall be galvanized after fabrication as per IS:4759 for all structural members. 3.5mm spring washers are to be used under each structural steel shall conform to IS 2026. All weld shall be 6mm filled weld unless specified otherwise. Anchor plat shall be of relevant IS
Supply & Erection of GI bolts & nuts, washers etc. (all Type) should be as per approved drawings & TS. All bolts & nuts, washers etc. shall be galvanized as per IS:4759. 3.5mm spring washers are to be used under each nut shall conform to IS 2026. All nuts and bolts shall be of property class 5.6 of IS 1367. Plain washers shall be as per IS 2016 & spring washers shall be IS: 3063 and foundation bolts, shall be of relevant IS
Gantry Foundation
Supply & Erecrion of 36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Construction of Plinth & foundation for 33 kV VCB
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch)
Supply & Erection of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications. (Without Earth Switch)
Construction of Plinth & foundation for 33 kV Isolator
Supply & Erection of 30kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.)
Construction of Plinth & foundation for 33 kV LA
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 3 secondery, core), 1 set = 3 Nos outdoor type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Construction of Plinth & foundation for 33 kV CT
Supply & Erection of 33 kV Transformer Panel (with diffirential relay and 5/1 A auxillary CT) complete
Supply & Erection 11 KV VCB Switchgears
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for Incomer along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer 3 Core, Potential Transformer 11KV/110 V, indoor mounting type control panel for incoming breaker and required accessories, A-meter, volt-meter, 3-phase , , Numerical Relays & accessories complete as per specifications for transformer breaker protection with earth fault, overcurrent .
Supply & Erection of 12 kV, 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit Breaker for along with 12 kV, 1-Phase, 25kA, 600-300/5-5 A, 3 Nos indoor type Current Transformer, control panel for Bus couplar and required accessories, A-meter, Numerical Relays & accessories complete as per specifications for Bus Coupler protection with earth fault, overcurrent .
Supply & Erection of 12 KV 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
11 KV 3 Core Al. XLPE Insulated Cable
Supply of 3x300mm sq.
Supply of 3x185mm sq.
Laying of 11 KV U/G cable includnig cost of sand and bricks
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x300 Sq.mm. cable size
Supply & Erection Termination kit 3Cx 300 sqmm outdoor
Supply & Erection of Termination kit 3Cx 300 sqmm Indoor
Heat Shrinkable jointing kit suitable for 11kV XLPE 3x185 Sq.mm. cable size
Supply & Erection Termination kit 3Cx 185sqmm outdoor
Supply & Erection of Termination kit 3Cx 185 sqmm Indoor
Control Cable
Supply & Laying 4x2.5 mm sq.
Supply & Laying 2x2.5 mm sq.
Earthing of substation complete as per specification
Supply & Erection of 75 x 8 mm GI flat.
Supply & Erection of 50 x 6 mm GI flat.
Supply & Erection of 32 mm dia MS rod 6 m long for earth mat
Supply & Erection of 40 mm dia., 3000 mm long GI pipe earth electrode as per Technical Specification
Supply & Erection of 33 KV Post Insulator (1 Set = 2 Nos of 22 KV)
Construction of Plinth & foundation for 33 kV Post Insulator
Supply & Erection of 33 KV Disc Insulator Insulator (1 Set = 4 Nos Disc Insulator 70 KN)
Supply & Erection of Hardware fitting for 33 KV Disc Insulator (B&S Type 70 KN)
Supply & Erection of 33 KV Polymer Pin Insulator with Nut & Bolt .
Supply & Erection of Bimetalic Clamps , Al. Connectors, Al. tape etc. complete in all respect as required.
11kV Feeder Double Pole structure on 11kV STP alongwith fitting
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of Barbed wire
Supply & Erection of Adnger Board
Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt.
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
conversion of Existing substations to GIS substations with Increasing capacity and One no E-House additional substation establish SCADA compatibility( 2x10 MVA -2Nos ,3x10 MVA -1 No & 4x10 MVA 2 nos
Supply & installation & Commissioning of 10 MVA 33/11 kV Transformer with all complete assesories as per TS
Construction of Plinth &Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS
Supply & Erection of 33 KV GIS incomer Panels , all complete with numerical relays, facility for data transmission and remote control . Ap per TS
Supply & Erection of 33 KV GIS outgoing Panels , all complete with numerical relays, facility for data transmission and remote control . As per TS
Supply & Erection of 33 KV GIS bus coupler Panels , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. As per TS
Supply & Erection of 11 KV GIS incomer Panels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section.
Supply & Erection of 11 KV GIS Outgoing Panels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section.
Supply & Erection of 11 KV GIS Bus couplerPanels with , all complete with numerical relays, facility for data transmission and remote control this includes PT raiser panel etc. if required. PT required for each of the bus section.
Supply & Erection of 40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories as per TS.
Supply & Erection of 60x8 mm Galvanized flat for raiser for earthing as per TS
Supply & Laying of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray.
Supply & Laying of 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray.
Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items
Supply & Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items
Supply & Laying of Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items
Supply & Erection of 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm
Supply & Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm(Incoming)
Supply & Erection of 33KV XLPE Cable (3x400 Sq.mm.) outdoor Heat Shrinkable Termination kit boxes mounted.
Supply & Erection of 11KV XLPE Cable (3x300 Sq.mm.) outdoor Heat Shrinkable Termination kit boxes mounted.
Dismentling of existing 33 KV & 11 Panel including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory.
Dismentling of existing 33 KV isolator,CT ,PT & CB with structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory.
Dismentling of existing 33 KV Bay with structure including storage, handling, insurance, loading, unloading, transportation to store of Utility as per the direction of Engineer-in-charge with propoer accounting as per the inventory.
E-House Substation establish SCADA compatibility ( 2x10MVA)
Supply , installation, testing and comrnissiong of 10 MVA Power Transformer,33/11 kV, 3 ph, 50 Hz, ONAN, Cu Wound, Outdoor Conventional type PowerTransformer with off load tap charger ( completely field with oil) as per TS per the specifications. The bansformer shall be complete with all accessories shall be provided with cable box termination arrangement on HV & LV side.
Supply, installation, testing and commissioning of Pre-fabricated Containerized Substation shall made of GI (2mm thick for load bearing and 1.5mm for non load bearing members) having IP 54 enclosure with 50mm rockwool 2hr Fire rated thermal insulation Along with a. 33kV Indoor Primary GIS as per TS ( 2 Incomer VCB +1 Bus Caupler +2 Outgoing VCB for 10 MVA Transformer) — 1 Set b. llkV Indoor Primary GIS as per TS ( 2 Incomer VCB + 1Bus Caupler +6 Outgoing VCB)- 1 Set c. 1 No Entry/Exit door Provision for E-House. 1 door shall be suitable for equipment entry from inside only d. Battery Bank 48VDC 150 AH - 1 Set e. Dual Float cum Boost Battery Charger suitable for 48 V DC, 80 A ( Auto and Manual) - lNo. f. ACDB - 1 Set g. DCDB- 1 set h. Fire Alarm System & Fire Extinguisher(Co2 type) - 1 Set i. AC system (N+1) & AC Control panel - 1 Set j. LT power & control cabling within the container equipment k. Station earthing grid internal to Container. l. Lightning protection for Metallic container . m. Ilumination System normal & emergency (48V DC) lighting, Lighting Panels, switches and sockets. n. Survillance system complete in all respects(with data backup facilty for 60days)camera 6nos i.e. 2Nos for covering entrance, 2Nos for internal area & 2Nos for acess control system with acess card o. Metallic container with doors with access control, access platforms. p. Supply of termination kits for 33kV & llKV GIS & termination of cables at site. q. Rubber Insulation mats — As required. Size of Container should be 15 meter X 4.5Meter with sufficient provision for acess (max) The enclosure shall contain all the indoor equipments like 33KV GIS, llKV GIS, ACDB,DCDB, RTU panel, RTCC panel, banery chargers, Lightining system, Fire safety system as per the tender specifications.The Container should have following A)33kv Indoor Gas Insulated Switchgear Panel 1250 A, 31.5KA/3sec which consists of 2 No Line feeder,1 Bus Caupler, 2No transformer feeder ( 9 Panels GIS BOARD) as per the enclosed Technical specifications. Internal arc tested panel as per IAC AFLR 31.5 kA for 1sec.The GIS shall be 3 phase combined and single bus type. CT ratio shall be 400/1+1+1+1 A and PT shall be 33000/sqrt3 Volt/110/sqrt3 Volt. Vacuum Circuit breaker, numerical relays having IEC 61850 protocol and multifunctional meters for SCADA compatibility as per atmched technical specification.All the GIS panels shall be operated and monitored through SCADA. B)11kv Indoor Gas Insulated Switchgear Panel 1250A, 25 KA/3sec which consists of 1 No Line feeder, 2 No Substation transformer feeder, 6 Nos Outgoing feeders (9 Panel GIS BOARD) as per the enclosed Technical specifications.Internal arc tested panel as per IAC AFLR 25 kA for 1 sec.The GIS shall be 3 phase combined and single bus type. CT ratio for the incomer shall be ***/1+1+1 A and PT shall be 11000/sqrt3 Volt/110/sqrt 3 Volt. Vacuum Circuit breaker, numerical relays having IEC 61850 protocol and multifunctional meters for SCADA compatibility as per attached technical specification.All the GIS panels shall be operated and monitored through SCADA. C) Remote Terminal Unit Panel with Ethernet Switch and interposing relay DI/DO as per the mentioned GIS panels list which includes Master Remote Terminal unit, RTU Control Panel & Cabling between RTU and GIS Panel boards.
Supply & Erection of 100KVA, 11 kV/0.415 kv Station Transformer alongwith all accessories as per TS.Energy Efficiency Level-1
Supply & Erection of 40mm dia 3000mm long GI Pipe (Medium Grade) earth electrodes & other accessories for treated earth erection is including of Excavation and other associated activities as per TS.
Supply & Erection of 60x8 mm Galvanized flat for raiser for earthing as per TS
Suplly & Erection of 30 KV, 1 Phase, 10KA LA with all accessories as per TS.
Supply & Erection of 9 KV, 1 Phase, 10KA LA with all accessories as per TS.
Supply & Erection of 3Cx400 sqmm. 33 KV cable (Panel to Transformer- 1 Run) with cable tray.
Supply & Erection of 3Cx300 sqmm. 11 KV cable (Panel to Transformer- 2 Run) with cable tray.
Supply & Laying of Control Cable of 2 core 2.5 sq. mm copper cable with cable tray and associated items
Supply & Laying of Control Cable of 4 core 2.5 sq. mm copper cable with cable tray associated items
Supply & Layingof Control Cable of 10 core 2.5 sq. mm copper cable with cable tray associated items
Supply & Erection Fire Fighting Equipment comprises of Dry Chemical Powder Type (ABC MAP50 Type As per IS 2171) (6 Kg). 4nos for control room, CO 2 Type of 4.5Kg Capacity 4 nos for Control Room, Fire buckets with Stand set( 4 nos ) including their stand as per technical specifications, scope of works and approved drawings
Supply of Synthetic Rubber mats as per IS 15652 in control room 2.5 mm thik
Supply and Erection of 33 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 400 sqmm
Supply and erection of 11 kV Silicon coated touchproof Indoor termination joint (Al) kit for XLPE 3 C X 300 sqmm(Incoming)
Supply and Erection of 33KV XLPE Cable (3x400 Sq.mm.) outdoor Heat Shrinkable Termination kit boxes mounted with transformer.
Supply and Erection of 11KV XLPE Cable (3x300 Sq.mm.) outdoor Heat Shrinkable Termination kit boxes mounted with transformer.
Construction of Plinth & Foundation for 10 MVA, 33/11 kV transformer including rail poles as per approved drawing as per TS
Supply & Erection of Station Lighting System (External) 120 Watt, LED with proper illumination complete for switchyard, main gate and sub-station boundry including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. all complte as per applicable TS and approved drawing. (minimum 8 nos on Lighting Poles & 8 nos on structure & control room )
Supply & Erection of Station Lighting System (internal) with proper illumination complete for control room building, Incharge room, Battery room, Store room, Washroom, Guard room, portico etc. including all associated materials such as insulated wires, cables, boards, switches and fixing arrangements etc. and Celling, wall Fan & exhast fan (Total 8 nos.) all complte as per applicable TS and approved drawing.
Construction of Boundary Wall (including supply of material) with fixing of MS angle & Barbed wire fencing(around Transformer and wherever required) all along the boudary wall including Plastering and Distempering(both sides),supply and fixing of main gate - complete with painting (with double coating of metallic primer and paint)etc. all as per approved drawing & TS (Measurement for this purpose will include length of the gate along the boundary wall).
Civils works(including supply of material) for 33/1 lkV containerised substation including foundation, including RCC cable trench with precast trench covers for incoming and outgoing cables(Both 33KV & llKV ) and other related works to complete installation, testing, commissioning of substation included.
Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system, drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per approved drawing or as per instruction of Engineer -in- Charge (including supply of material)
Development of land includes filling of land upto two feet above thr adjoining road, construction of wash room cum toilet with septic and overhead water tanks,drainage system, drinking water supply(Borewell with submersible pump set complete),sewerage system of substation, construction of approch road(5mtr wide) etc. as per
Constriction (including supply of all material) of RCC cable trench along with pre-cast RCC trench cover, Brick work whenever required all complete as per approved drawing and TS outside the conbol room building - 0.5 Mtrs wide bench.
11kV Feeder Double Pole structure on 11kV STP alongwith fitting (as per Annex-9)
Supply & Erection of 11 Mtr. long Steel Tubulor Pole SP-55 with Base Plate. (410 SP 55)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Suplly & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of 11 KV fuse set with fixing clamps Angle & Nut & Bolt.
Supply & Erection of Earthing of pole by GI earthing rod of 20x2500 mm. and 6 SWG earthing wire etc.
3.96 MVAr With APFC Panel As per TS
Supply & Erection of 12.65 kV, 3960 kVAr, 3-Phase, 50 C/s housed in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(3.96 MVAr HT Capacitor bank)
Casting of Civil foundation(3.96 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank)
Supply & Erection for New 33 KV Line on 9 mtr PCC pole with DOG conductor as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Eerection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice)
Supply & Erection of Stone Pad (300x300x75mm)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 33 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings
Supply & Erection of 33 KV 10 KN Polymer Pin Insulators
8 SWG GI Coil 115 turns (1.85 Kg)
Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Grouting of complete stay set with 0.3 cumt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Erection for New 33 KV Line on 11 mtr steel tubular pole with DOG conductor as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for erection of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 33 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type)
Supply & Erection of 33 KV 10 KN Polymer Pin Insulators
8 SWG GI Coil 115 turns (1.85 Kg)
Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Pinting of silver paint
Supply & Painting of red oxide paint
Supply & Erection for New 33 KV Line on 13 mtr steel tubular pole with DOG conductor as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Supply & Erection of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) As per TS
Excvation & Grouting of 13 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 33 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings (B&S Type)
Supply & Erection of 33 KV 10 KN Polymer Pin Insulators
8 SWG GI Coil 115 turns (1.85 Kg)
Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Painting of silver paint
Supply & Paintingof red oxide paint
Supply & Erection of 33 KV Under ground cable as per technical specification, approved drawings and scope of work.
Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable .
Digging of trench for laying of Double circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab ("PuVVNL 33 KV HT" engraved) after laying of cable into the trench including providing and fixing cable route marker.
Digging of trench for laying of Single circuit 33KV 3x300 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone/Precast slab ("PuVVNL 33 KV HT" engraved) after laying of cable into the trench including providing and fixing cable route marker.
Laying of Single circuit of 3x300 Sq. mm 33 KV XLPE insulated cable underground in cable trenches and earth filling of trenches
Laying of 33 KV 3x300 Sqmm. XLPE Cable underground through HDPE Pipe at 1050 mm below the ground surface.(by HDD method) for road crossing including providing and fixing cable route marker.
Supply of 160 mm dia. HDPE pipe.(PE -80 & PN-6)
Laying of 160 mm dia. HDPE pipe by Horizontal drilling by HDD method as per site condition, for underground piping (trenchless) for road crossing.
Supply & Erection of of Heat Shrinkable Jointing Straight Through Kit for 33 KV 3x300 sq. mm XLPE Cable
Supply & Erection of of Heat Shrinkable Jointing Straight Through Kit for 33 KV 3x300 sq. mm XLPE Cable
Supply & Erection of G.I. pipe 150mm with clamp and nut & bolts
Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size
Supply & Erection of 33 KV Line underground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection, testing & commissioning of 33 kV LINE FOR UNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE) 3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
Supply & Erection of 11 KV Line underground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection, testing & commissioning of 33 kV LINE FOR UNDER GROUND Highway CROSSING (200 Mtr) BY 2 Nos (INCLUDING ONE SPARE) 3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
Supply & Erection For Construction of new 11 KV line on 8.5 mtr PCC pole with weasel conductor as per technical specifications, scope of works and approved drawings
Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Supply & Erection of Stone Pad (300x300x75mm)
Erection of 8.5 m/180 Kgs PCC Poles with Base stone pad including cement concrete foundation using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications (state practices of PCC pole and base plate/stone to be used)
Supply & Erection of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Weasel to Weasel conductor
Supply & Erection For Construction of new 11 KV line on 11 mtr STP pole with Rabbit conductor as per technical specifications, scope of works and approved drawings
Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection for Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Rabbit to Rabbit conductor
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Supply & Erection For Construction of new 11 KV line on 11 mtr STP pole with Dog conductor as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings (B&S Type)
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt.
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Grouthing 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Supply & Erection For Construction of new 11 KV line on 8.5 mtr PCC pole with Rabbit conductor as per technical specifications, scope of works and approved drawings
Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Supply & Erection of Stone Pad (300x300x75mm)
Excavation and Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with Nut & Bolt.
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Rabbit to Rabbit conductor
Supply & Erection of 11 KV Line underground 3*185 XLPE Cable ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply of 3Cx185 Sqmm 11 KV XLPE Armored Cable
Digging of trench for laying of double circuit 11KV 3x185 sq.mm XLPE cable and making of trench for two nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab /Precast slab ("PuVVNL 11 KV HT" engraved) after laying of cable into the trench including providing and fixing cable route marker.
Digging of trench for laying of Single circuit 11KV 3x185 sq.mm XLPE cable and making of trench for one nos cable with brick on both side, sand filling into the trench and finally trench will be covered with stone slab after laying of cable into the trench.
Laying of single circuit of 3x185 Sq. mm 11 KV XLPE insulated cable underground in cable trenches and earth filling of trenches
Laying of 11 KV 3Cx185 sq.mm XLPE Cable underground through HDPE Pipe at 950 mm below the ground surface. (by HDD method) including providing and fixing cable route marker.
Supply & Erection of 110 mm dia. HDPE pipe .
Supply & Erection of Heat Shrinkable Jointing Kit Straight through for 11 KV 3x185 sq. mm XLPE Cable
Supply & Erection of Heat Shrinkable Jointing Kit Outdoor for 11 KV 3x185 sq. mm XLPE Cable
Supply & Erection of G.I. pipe 110 mm dia with clamps, Nut and Bolts.
Hoisting of cable on double pole with the help of cable clamp with N&B of suitable size
Supply & Erection For new 11 KV line on 11 mtr STP with insulated covered (50 sq mm) conductor as per technical specifications, scope of works and approved drawings
Supply Of Insulated ACS Covered Conductor Size equivalent to Rabbit conductor.
Erection of Insulated ACS Covered Conductor Size equivalent to Rabbit conductor.
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection Tension clamp/Dead Clamp/Anchoring Clamp with Piercing Connectors suitable for MVCC.
Supply & Erection of IPC for CC to CC Connection suitable for MVCC
Supply & Erection of IPC/Connector for Bare to CC Connection suitable for MVCC
Supply & Erection of Suspension/Insulated Ties
Supply & Erection of Mid Span Jointing Kit
Supply & Erection of IPC with Aluminium bail for earthing
Supply & Erection of Termination Kits
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Supply & Erection For new 11 KV line on 3x70 sqmm XLPE cable as per technical specifications, scope of works and approved drawings
Supply of 11 Kv Line on 3x70 sqmm XLPE Cable
Erection of 11 Kv Line on 3x70 sqmm XLPE Cable
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp, pole clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of cable Jointing kit for 11 kv Line 70 sqmm
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Supply & Erection of 11 KV Line underground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection , testing & commissioning for 11 KV line under ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
Supply & Erection of 11 LV Line underground Highway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection , testing & commissioning of 11 KV LINE FOR UNDER GROUND Highway CROSSING BY 2 Nos (INCLUDING ONE SPARE) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) USING 160 mm HDPE pipe at road crossing and 150MM DIA GI PIPES (grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, 7/20 GI wire, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
New Distribution Transformer 25 KVA 11/433 KV - Supply
supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11 mtr STP Pole of depth 1.8 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel, Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators
Supply & Erection of 11 KV 45 KN polymer Disc insulator as per TS.
Supply & Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductor as per TS.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Barbed GI wire 12 SWG
Supply & Erection of PG Clamp suitable for ACSR Rabbit conductor as per TS
Supply & Erection of 11 KV danger board
Supply & Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS
Supply Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS
Supply of 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1
Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCB for two no outgoing feeder suitable for 25 kVA, Distribution Transformer alongwith suitable for pole mounting as per TS
Supply & Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestor with Disconnector for DT as per TS. (3 nos=1 set)
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Supply & Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS
New Distribution Transformer 63 KVA 11/433 KV - Supply
supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11 mtr STP Pole of depth 1.8 meter with 300 mm Muffing.As per TS.
Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel, Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators
Supply & Erection of 11 KV 45 KN polymer Disc insulator as per TS.
Supply & Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductor as per TS.
Supply & Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erectoin of 6 SWG GI wire for earthing as per TS
Supply & Erection of Barbed GI wire 12 SWG
Supply & Erection of PG Clamp suitable for ACSR Weasel conductor as per TS
Supply & Erection of 11 KV danger board
Supply & Erection of 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS
Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS
Supply & Erection of 3-Phase, 11/0.4 kV, 63 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1
Supply & Erection of of LT Distribution box with suitable rating MCCB for incomer & MCCB for two no outgoing feeder suitable for 63 kVA, Dist1ibution Transformer alongwith suitable for pole mounting as per TS
Supply & Erection of of 9 kV, 5 KA porcelain housing Lightning Arrestor with Disconnector for DT as per TS. (3 nos=1 set)
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Supply & Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS
New Distribution Transformer 100 KVA 11/433 KV - Supply
supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11 mtr STP Pole of depth 1.8 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel, Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators
Supply & Erection of 11 KV 45 KN polymer Disc insulator as per TS.
Supply & Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductor as per TS.
Supply & Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erectoin of 6 SWG GI wire for earthing as per TS
Supply & Erection of Barbed GI wire 12 SWG
Supply & Erection of PG Clamp suitable for ACSR Weasel conductor as per TS
Supply & Erection of 11 KV danger board
Supply & Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS
Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS
Supply & Erection of 3-Phase, 11/0.4 kV, 100 KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS ,Energy Efficiency Level-1
Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCB for two no outgoing feeder suitable for 100 kVA, Dist1ibution Transformer alongwith suitable for pole mounting as per TS
Supply & Erection of 9 kV, 5 KA porcelain housing Lightning Arrestor with Disconnector for DT as per TS. (3 nos=1 set)
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm .
Supply & Erection Earthing Arrangement of chemical pipe size of 40x3000 mm. a etc.
Supply & Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS
New Distribution Transformer 250 KVA 11/433 KV - Supply
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting f 0.5 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 11 mtr STP Pole of depth 1.8 meter with 300 mm Muffing.As per TS.
Supply & Erectionof new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel, Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete as per TS & approved drawings.
Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators
Supply & Erection of 11 KV 45 KN polymer Disc insulator as per TS.
Supply & Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductor as per TS.
Supply & Erectoin of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erectoin of 6 SWG GI wire for earthing as per TS
Supply & Erection of Barbed GI wire 12 SWG
Supply & Erection of PG Clamp suitable for ACSR Weasel conductor as per TS
Supply & Erection of 11 KV danger board
Supply & Erectionof 11 KV, 3-Pole, 3-Ph, 400A, A B Switch as per TS
Supply & Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS
Supply & Erection of 3-Phase, 11/0.4 kV, 250 KVA, Self Protected, Copper winding & CRGO core Distribution Transformer as per TS, Energy Efficiency Level-1
Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCB for two no outgoing feeder suitable for 250 kVA, Dist1ibution Transformer alongwith suitable for pole mounting as per TS
Supply & Erection of 9 kV, 5 KA porcelain housing Lightning Arrestor with Disconnector for DT as per TS. (3 nos=1 set)
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Supply & Erection of 1-Core 240 mm2, Al. LT XLPE Cable as per TS
Augmentation of 10 kva & 16 kva to 25kva Distribution transformer
Supply & Erection of 11/0.433 kV 25 kVA Distribution Transformer as per TS.Energy Efficiency Level-1
Supply & Erection of LT PVC Cable 3.5x70Sq.mm
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Replacment & Transpotation Charge of Existing Distribution Transformer
Augmentation of 25 Kva to 63kva Distribution transformer
Supply & Erection 11/0.433 kV 63 kVA Distribution Transformer as per TS. Energy Efficiency Level-1
Supply & Erection LT PVC Cable 3.5x70Sq.mm
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Replacment & Transpotation Charge of Existing Distribution Transformer
Augmentation of 63 kva to 100 kva Distribution transformer
Supply & Erection of 11/0.433 kV 100 kVA Distribution Transformer as per TS. Energy Efficiency Level-1
Supply & Erection of LT PVC Cable 3.5x150Sq.mm
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Replacment & Transpotation Charge of Existing Distribution Transformer
Augmentation of 100 kva & 160 kva to 250 kva Distribution transformer
Supply & Erection of 11/0.4 KV Distribution Transformer 250 KVA 3 phase DTR(Copper Winding), Energy Efficiency Level-1
Supply & Erectionof LT PVC cable AI 3.5x400 sq mm
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erectionof Earthing for pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erection of Earthing for Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Replacment & Transpotation Charge of Existing Distribution Transformer
Augmentation of 250 kva to 400 kva Distribution transformer
Supply & Erection of 11/0.4 KV Distribution Transformer 400 KVA 3 phase DTR(Copper Winding, Energy Efficiency Level-1
Supply & Erection of LT PVC XLPE cable AI 1x400 sq mm
Supply & Erection of LT PVC XLPE cable AI 1x240 sq mm
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm & 6SWG earthing wire etc.
Supply & Erectionof Earthing Arrangement of chemical pipe size of 40x3000 mm. and 6 SWG earthing wire etc.
Supply & Erection of Al Lug long barrel, off size (LS)
Replacment & Transpotation Charge of Existing Distribution Transformer
Supply & Erection of Trolly Mounted DT- of 400KVA as per technical specifications, scope of works and approved drawings
Supply & Erection of 11/0.415 kV 400 KVA Distribution Transformer Copper Winding. Energy Efficiency Level-1
Supply & Erection of Fabricated Trolley With 4 Tyre wheels to house Transformer with all fixing Arrangement along with fencing and locking mechanism.
Supply & Erection of 3x50 mm² 11KV class XLPE Cable.
Supply & Erection of Heat shrinkable Termination kits suitable for 3x50 mm²Xlpe Cable (out door) including bushing cap.
Supply & Erection of 400 Sq.mm., LT single core `XLPE insulated un-armoured aluminium conductor cable
Supply & Erection of Protection of DT as per technical specifications, scope of works and approved drawings
Supply & Erection of AB switch suitable for Distribution Transformer 100 KVA and above
Supply & Erection of DO Fuse set suitable for Distribution Transformer 100 KVA and above
Supply & Erection of LT ACB suitable for Distribution transformers having capacity 250 KVA and above Ap per TS
Supply & Erection of LT Distribution box suitable for Distribution Transformer upto 250 KVA As per TS
Supply & Erection of LT Distribution box suitable for Distribution Transformer 400 KVA and above As per TS
Supply & Erection of DT Cable with Lugs & Clamp as per technical specifications, scope of works and approved drawings
Supply & Erection of LT XLPE Insulated Cable 1CX240 Sqmm
Supply & Erection LT XLPE Insulated Cable 1CX400 Sqmm
Supply & ErectionLTXLPE Insulated Cable 1CX630 Sqmm
New LT line on 8.5 mtr PCC pole with AB cable ( (1x16+1x25+1x16)
Supply of LT Aerial bunched XLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Eection of LT Aerial bunched XLPE cable 1X16 sqmm (Ph) + 1x25 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erectionof 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 16 -16 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-25 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
New Lt 8.5 Mtr PCC LT Ckt. with AB Cable (3x50+1x35+1x16)
Supply of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16)
Supply of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erectionof 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erectionof hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16)
Supply of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Gruoting Of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Strengthening of LT infrastructure by removal of bans and balli in identified areas-Schedule for regularisation of Bas Balli cable for under Varanasi -1 as per TS & Approved Drawings.
Supply & Erection of PCC Pole 8.5 mtr long
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 mtr PCC pole Pole of .As per TS.
Supply & Erection of stone pad (300x300x75mm)
Supply & Erection of STP 9 mtr SP-33 (410 SP 33)
Concreting of supports with Grounting of 0.3 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9 mtr stp pole Pole of depth 1.8 meter with 300 mm Muffing.As per TS.
Supply & erection of Stay set 16x1800 sq mm (including stay rod , turn buckle,I bolt and anchor plate with Guy insulator)
Supply & Erection of GI Earthing rod (20x2500)mm
Supply & Erection of Stay wire 7/10 SWG
Supply of & Erection of G.I. wire 5 mm 6 swg
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply of LT A B Cable Size (3x50+1x35+1x16) sq mm with Bare Massenger ( Insulated Street Lighting )
Erection of LT A B Cable Size (3x50+1x35+1x16) sq mm with Bare Massenger ( Insulated Street Lighting )
Supply of LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger ( Insulated Street Lighting )
Erectionof LT A B Cable Size (3x95+1x70+1x16) sq mm with Bare Massenger ( Insulated Street Lighting )
Supply of & Erection of Suspension clamp with eye hook
Supply of & Erection of Dead end clamp insulated with I hook
Supply of & Erection of HDG pole Clamp for I-Hook with N&B
Supply of & Erection of LT Insulation piercing connector 95-35 sqmm / 50-35 sqmm size
Supply of & Erection of Three phase LT SMC Box with clamp
Supply of & Erection of PG clamp for Neutral
Supply of L T XLPE unarmoured Cable of size 4C x 35 sq mm
Erection of L T XLPE unarmoured Cable of size 4C x 35 sq mm
Supply of & Erection of pre insulated compression connector of size 95/50 Sqmm
Supply of & Erection of Stay clamp with N&B
Extra Circuits 8.5 Mtr PCC LT Ckt. with AB Cable (3x50+1x35+1x16)
Supply of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuits 8.5 Mtr PCC LT Ckt. with AB Cable (3x95+1x70+1x16)
Supply of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting f 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuits 9 mtr STP Pole LT Ckt. with AB Cable (3x95+1x70+1x16)
Supply of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 8.5 Mtr/180 kgs PCC Poles with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erectionof 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 9 mtr steel tubular pole with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Gruoting Of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1120+1x16)
Supply of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 9 mtr steel tubular pole with AB cable (3x150+1x120+1x16)
Supply of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Extra Circuit LT line with 11 mtr steel tubular pole with AB cable (3x150+1x120+1x16)
Supply of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X150 sqmm (Ph) + 1x120 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 150 -150 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 150-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Augmentation of LT line with 8.5 Mtr PCC Pole pole with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Augmentation of LT line with 9 Mtr STP Pole pole with AB cable (3x120+1x95+1x16)
Supply of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X120 sqmm (Ph) + 1x95 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 120 -120 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 120-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Augmentation of LT line on 8.5 mtr PCC pole with AB cable (3x95+1x70+1x16)
Supply of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Augmentation of LT line on 9 Mtr STP pole with AB cable (3x95+1x70+1x16)
Supply of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X95 sqmm (Ph) + 1x70 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 9 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 33 (IS 2713, Pt I, II, III 1980)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 95 -95 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 95-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
Supply & Erection of Feeder Bifurcation ( 33KV line on 9 mtr PCC pole(Dog conductor)) as per approved drawings, technical specifications and scope of work
Supply of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Erection of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Supply & Erection 9m/400 kgs PCC Poles (PCC pole as per state practice)
Supply & Erection of Stone Pad 300x300x75 MM
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter .As per TS.
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of Barbed wire
Supply & Erection of Danger Board
Supply & Erection of Number Plate
Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire
Grouting of complete stay set with 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection 33 KV polymer Disc insulator 70 KN B&S along with suitable hardware fittings
Supplt & Erection of 33 KV polymer Pin insulators with GI Pin & nuts
Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt
Supply & Erection of 6 SWG GI wire,
Supply & Eection of 8 SWG GI wire
Supply & Erection of Feeder Bifurcation (33KV line on 11 mtr steel tubular pole(Dog conductor)) as per approved drawings, technical specifications and scope of work
Supply of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Erection of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Supply & Erection of 11 m long steel tubular poles with welded steel base plate of designation 410 SP 55 (As per IS: 2713 , pt. I,II,III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of Danger Board
Supply & Erection of barbed wire
Supply & Erection of Number Plate
Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire
Erection of complete stay set with 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 33 KV polymer Disc insulator 70 KN B&S along with suitable hardware fittings
Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts
Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt
Supply & Erection of 6 SWG Wire
Supply & Erection of 8 SWG GI wire,
Supply & Painting of silver paint
Supply & painting of red oxide paint
Supply & Erection of Feeder Bifurcation (33KV Line on 13 mtr steel tubular pole Dog conductor) as per approved drawings, technical specifications and scope of work
Supply of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Erection of 6/4.72 + 7/1.57 mm (100 mm2 Al.area ) - Dog
Supply & Erection of 13 m long STP SP72
Supply & Erection of Stone Pad 300x300x75 MM
Concreting of poles as per specification
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of Danger Board
Supply & Erection of Barbed wire
Supply & Erection of Number Plate
Supply & Erection of Stay Set ( Galvanised) GI stay rod 20x1800 mm, stay wire 7/8 SWG GI wire, 50x8 mm stay clamp, stay insulator (2 nos.), anchor plate (300x300x8), nut bolts, 2 nos. turn buckles, 1.8 m long 20 mm dia. Solid GI Stay Rod, 7/4.0mm dia. GI stranded wire
Grouting of stay set with 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 33 KV polymer Disc insulator 70 KN B&S along with suitable hardware fittings
Supply & Erection of 33 KV polymer Pin insulators with GI Pin & nuts
Supply & Erection of GI earthing Spike earthing 20x2500 mm solid rod & 6 SWG earthwire with nut and bolt
Supply & Erection of 6 SWG GI wire,
Supply & Erection of 8 SWG GI wire,
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Supply & Erection of 33 KV Line underground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection, testing & commissioning of 33 kV LINE FOR UNDER GROUND RAILWAY CROSSING (300 Mtr) BY 2 Nos (INCLUDING ONE SPARE) 3Cx300 Sqmm XLPE Armoured Cable USING 150MM DIA GI PIPES (grade A for underground laying and grade B for pole support), OUTDOOR HEAT SHRINKABLE CABLE JOINTING KITS, LUGS, 4 Nos GI 3-Meters LONG pipe, EARTHING, 8 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS, JUMPERING , AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Weasel conductor) using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings
Supply of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor
Erection of 6/2.59 + 1/2.59 mm (30 mm² Al. Area) - Weasel conductor
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Grouting of 8.5 PCC pole using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used)
Supply & Erection of Stone Pad (300x300x75mm)
Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Weasel to Weasel conductor
Supply & Erection of Aluminium Jointing sleave for ACSR Weasel
Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Rabbit conductor)using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings
Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit conductor
Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit conductor
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Grouting of 8.5 PCC pole using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used)
Supply & Erection of Stone Pad (300x300x75mm)
Supply & Erection for New 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Rabbit to Rabbit conductor
Supply & Erection of Aluminium Jointing sleave for ACSR Rabbit
Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 8.5 mtr PCC pole (Dog conductor) using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Grouting of 8.5 PCC pole using 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) 0.268 cum. etc as per scope of work, approved drawings and specifications: (state practices of PCC pole and base plate/stone to be used,)
Supply & Erection of Stone Pad (300x300x75mm)
Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Erection of Aluminium Jointing sleave for ACSR DOG
Supply & Erection for Feeder Bifurcation of 3 phase 11 kV line on 11 mtr STP (Dog conductor) using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog conductor
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erectio of Stone Pad (300x300x75mm)
Supply & Erection for new 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Erection of Aluminium Jointing sleave for ACSR DOG
Supply & Erection of 11 KV Line underground railway crossing ensuring statutory clearances as required as per technical specification, approved drawings and scope of work
Supply & Erection for 11 KV line under ground Railway crossing with 2 nos (Including one spare) 3Cx185 Sqmm XLPE Armored Cable (0.3 km each) using 150mm dia GI pipes (grade A for underground laying and grade B for pole support), Outdoor heat shrinkable cable jointing kit, 11 KV LIGHTENING ARRESTOR STATION CLASS 10KA (6 NOS.), LUGS, 4 Nos GI 3-Meters LONG pipe EARTHING, 6 SWG GI WIRES, CABLE MARKERS, BI METALLICK CLAMPS and JUMPERING etc AS REQUIRED AS PER TECHNICAL SPECIFICATIONS, DRAWINGS AND SCOPE OF THE WORK.
Supply & Erection of 12 KV 3ph Indoor type switch gear and 11 KV XLPE cable as per technical specifications, approved drawings and scope of works:
Supply & Erection of Indoor type 12 KV 3 Ph 1250 A VCB with control and protection system for out going feeder consisting of CT, A-meter, volt-meter, Relays, compliant & accessories complete as per specifications for feeder breaker
Supply & Laying of Cable AL 3X185 sqmm XLPE 11 KV
Supply & Erection of 11 KV cable jointing kit indoor 185 sq.mm.
Supply & Erection of 11 KV cable jointing kit outdoor 185 sq.mm.
Control Cable
Supply & Laying of 4x2.5 mm sq
Supply & Laying of 2x2.5mm sq
Supply & Erection of 11KV Agriculture Feeder Splitting LT line on 8.5 mtr PCC pole with AB cable (3x50+1x35+1x16) due to overloading as per approved drawings, technical specifications and scope of work
Supply of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Erection of LT Aerial bunched XLPE cable 3X50 sqmm (Ph) + 1x35 sqmm (bare messenger cum neutral) + 1x16 sqmm (insulated Street lighting)
Supply & Erection of 8.5 Mtr/180 kgs PCC Poles as per TS
Concreting of supports with Grounting of 0.268 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 8.5 Mtr PCC Pole of depth 1.4 meter.As per TS.
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. LT Pole Clamp, Eye Hook, Stay clamp, etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 20 mm dia 2500 mm long GI Earthing Rod together with fixing arrangement (excluding GI wire required for earthing) as per approved drawing.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for LT stay set
Supply & Erection of 8 SWG GI wire for earthing as per TS
Supply & Erection of Three phase SMC Distribution box with clamps
Supply & Erection of 4X35 mm^2 XLPE/PVC insulated AL. cable for energising the distribution boxes/Kiosk
Supply & Erection of Suspension clamp for LT Aerial Bunched Cable as per TS
Supply & Erection of Tension /dead end clamps for LT Aerial Bunched Cable as per TS
Supply & Erection of 35 Sqmm PG Clamps as per TS
Supply & Erection of LT Insulation piercing connector 50 -50 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 50-35 sqmm size for phase connection as per TS & approve drawing
Supply & Erection of LT Insulation piercing connector 16-16 sqmm size suitable for street light connection as per TS
New Distribution Transformer 25 KVA 11/433 KV - Supply
Supply & Erection of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of new Pre-fabricated hot dip galvanized steel items i.e. V cross arm, Pole Top Bracket, top channel, top clamp, Channel & Clamps, strain plate, 50x8 mm stay clamp,back clamps, MS transformer base channel, Transformer angles & Channels, AB switch channels & angles, HG fuse channls & angles, anti climbing device clamp etc. complete as per TS & approved drawings.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers as per TS
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators
Supply & Erection of 11 KV 45 KN polymer Disc insulator as per TS.
Supply & Erection of suitable 11KV 45KN disc hardware fittings T&C type 2U for ACSR Weasel conductor as per TS.
Supply & Erection of Stay Set (Galvanized) with anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod complete stay set as per TS
Stay Set Grouting 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per approved drawings, scope of works and TS.
Supply & Erection of stay guy insulator (1 Nos.), as per TS
Supply & Erection of 7/3.15 mm dia GI stranded Stay wire as per TS for 11 kV stay set
Supply & Erection of 6 SWG GI wire for earthing as per TS
Supply & Erection of Barbed GI wire 12 SWG
Supply & Erection of PG Clamp suitable for ACSR Rabbit conductor as per TS
Supply & Erection of 11 KV danger board
Supply & Erection of 11 KV, 3-Pole, 3-Ph, 400A, TPMO as per TS
Supply Erection of 11 KV, 3-Ph, 400A, DO Fuse as per TS
Supply & Erection of 3-Phase, 11/0.4 kV, 25KVA, Self Protected, Aluminium winding & CRGO core Distribution Transformer as per TS . Energy Efficiency Level-1
Supply & Erection of LT Distribution box with suitable rating MCCB for incomer & MCCB for two no outgoing feeder suitable for 25 kVA, Dist1ibution Transformer alongwith suitable for pole mounting as per TS
Supply & Erectionof 9 kV, 5 KA porcelain housing Lightning Arrestor with Disconnector for DT as per TS. (3 nos=1 set)
Supply & Erection of Earthing of pole by MS earthing rod of 20x2500mm .
Supply & Erection of Earthing Arrangement of chemical pipe size of 40x3000 mm.
Supply & Erection of 1-Core 70 mm2, Al. LT XLPE Cable as per TS
Supply & Erection for Augmentation / Reconductoring of 33 kV line With ACSR Panther Conductor of 3 phase 33 kV line using additional supports matching with length and type of existing support as per technical specifications, scope of works and approved drawings
Supply of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor
Erection of 30/3.00 + 7/3.00 mm (200 mm² Al. Area) - Panther conductor
Supply & Erection of 11 M long steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980)
Grouting of 11 M long Steel Tubular poles with welded steel base plate of Designation 410 SP 55 (IS 2713, Pt I, II, III 1980) - Cement concreting 0.5 cmt + 0.014 cmt (Muffing)
Supply & Erection of 9 m PCC Poles - (PCC Pole as per state practice)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr PCC Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection New Pre-fabricated hot dip galvanized steel item, for augmentation of 33 KV line, like V cross arm, top channel, top clamp, cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle (65x65x6mm), MS flats (65x8mm) anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 33 KV danger board
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 33 KV 70 KN polymer Disc Insulator along with suitable hardware fittings
Supply & Erection of 33 KV 10 KN Polymer Pin Insulators
Supply & Erection of 8 SWG GI Coil 115 turns (1.85 Kg)
Supply & Erection of new Stay Set (Galvanized) for 33 kV line with 50x8 mm stay clamp, 2 nos. guy insulator, anchor plate (300x300x8mm) , nut bolts, 1 no. turn-buckles, 1.8 m long, 20 mm diameter solid GS stay rod & 7/4.00 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Panther to panther conductor
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Dismantling of existing overhead line conductor and fittings, depositing the dismantled material to employer's store .
Supply & Erection of Augmentation / Reconductoring of 11KV line With ACSR DOG Conductorof Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work
Supply of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP
Erection of 6/4.72 mm+7/1.57 mm (100 mm² Al. Area) - Dog by replacing existing racoon/rabbit conductor on 11 Mtr STP
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing)
Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of Stone Pad (300x300x75mm)
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Dog to Dog conductor
Supply & Erection of Augmentation / Reconductoring of 11KV line With ACSR Rabbit Conductor of Feeder ( Older than 25 years ) as per approved drawings, technical specifications and scope of work
Supply of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP
Erection of 6/3.35 + 1/3.35 mm (50 mm² Al. Area) - Rabbit by replacing existing weasel/squirrel conductor- On 11 mtr STP
Supply & Erection of 8.5 meter long /180 KG PCC Poles (PCC Pole as per state practice)
Erection of 8.5 PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used) 0.268 cum Cement concreting+0.014 cmt (Muffing)
Supply & Erection for Augmentation of 3 phase 11 kV line using new Pre-fabricated hot dip galvanized steel items like V cross arm, top channel, top clamp, Cross arm, bracket, clamps, cross bracings, bracings, strain plate, guarding channels, back clamp, MS angle, MS flats pole extension canal with welded plate, anti climbing device clamp etc of given sizes for over head structures as per technical specification, approved drawings and scope of work.
Supply & Erection of hot dip galvanized MS Nuts, Bolts with Washers and turn buckle for guarding as per technical specification, approved drawings and scope of work.
Supply & Erection of 11 KV danger board
Supply & Erection of Stone Pad (300x300x75mm)
Supply & Erection of GI Barbed wire 12 SWG
Supply & Erection of 11 KV 45 KN polymer Disc insulator along with suitable hardware fittings
Supply & Erection of 11 KV 5 KN Polymer Pin Insulators with suitable hardware fittings
Supply & Erection of GI Earthing spike made of 20x2500mm solid Rod
Supply & Erection for Augmentation of 3 phase 11 kV line using new Stay Set (Galvanized) with 50x8 mm stay clamp, 1 no. guy insulator, anchor plate (200x200x6mm) , nut bolts, 1 no. turn-buckles, 1.8 m long 16 mm diameter solid GI stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.3 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of 6 SWG GI wire
Supply & Erection of 8 SWG GI wire
Supply & Erection of PG Clamp for Rabbit to Rabbit conductor
Supply & Erection of Automatic Capacitor Bank as per approved drawings, technical specifications and scope of work (1.98 MVAr With APFC Panel)
Supply & Erection of 12.65 kV, 1980 kVAr, 3-Phase, 50 C/s, housed in Outdoor Type CRCA panel , Capacitor bank having two variable step of 792 Kvar & one Variable steps of 396 kVAr. Bank shall be complete with Capacitor units of 264/132 kVAr,Aluminium busbars, Epoxy insulators, HT HRC fuse,Surge suppressor etc.with details as follows-(1 )11 KV Alumunium wound ,Dry type series reactor(a)0.528 KVAr for 792 KVAr step-6 nos. (b)0.264 KVAr for 396 kVAr step-3 nos. (2) 11 kV, 3-Phase Indoor Dry Type RVT-1 nos. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor-3 nos. (4) Indoor Type Automatic Control Unit-1 No. (5) IP 55, outdoor CRCA cubicle panel for accommodating capacitors, series reactors, vacuum contactor, surge supressor etc., along with FRP canopy-1 No.
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(1.98 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(1.98 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(1.98 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(1.98 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(1.98 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(1.98 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(1.98 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(1.98 MVAr HT Capacitor bank)
Supply & Erectio of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(1.98 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(1.98 MVAr HT Capacitor bank)
Casting of Civil foundation(1.98 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(1.98 MVAr HT Capacitor bank)
Supply & Erection of 3.96 MVAr With APFC Panel
Supply & Erection12.65 kV, 3960 kVAr, 3-Phase, 50 C/s housed in Outdoor Type CRCA Panel, Capacitor bank having two variable step of 792 Kvar& two Variable steps of 1188 kVAr. Bank shall be complete with Capacitor units of 396/264 kVAr, Aluminium busbars, Epoxy insulators, HT HRC fuse, Surge Suppressor etc.with details as follows-(1) 11 kV, Aluminium Wound, Dry type Series reactors a) 0.528 kVAr for 792 kVArstep - 6 Nos. , b) 0.792 kVAr for 1188 kVAr step - 6 Nos. (2) 11 kV, 3-Phase Dry Type RVT - 1 No. (3) 12 kV 3 Phase Indoor type metal enclosed Vacuum Contactor - 4 Nos. (4) Indoor Type Automatic Control Unit - 1 No.(5) IP 55 , Outdoor CRCA cubicle Panel for accommodating capacitors, Series Reactor, Vacuum contactor, Surge Suppressor etc., along with FRP Canopy- 1 set
Supply & Erection of 11 kV, 400 Amp, Off Load Isolator with earth switch and mounting structure.(3.96 MVAr HT Capacitor bank)
Supply & Erection of 9 kV, 10 kA,Station Class, Lightning Arrestors(3.96 MVAr HT Capacitor bank)
Supply & Erection of Indoor Type Automatic Control Unit(3.96 MVAr HT Capacitor bank)
Supply & Erection of IP 55 , Outdoor CRCA cubicle Panel for accomdating capacitors,Series Reactor,Vacuum contactor,Surge arrestor,Fuses(3.96 MVAr HT Capacitor bank)
Supply & Erection of Control cables, lugs/thimble, Junction Box etc.(3.96 MVAr HT Capacitor bank)
Supply & Laying of 11 KV 3 Core Al. XLPE Insulated 3x185 mm sq. Cable(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Indoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11KV XLPE Cable (3x185 sq.mm.) Heat Shrinkable Jointing kit Outdoor(3.96 MVAr HT Capacitor bank)
Supply & Erection of 11 KV VCB Switchgear with complete arangement for connection with existing 11 KV bus bar.(3.96 MVAr HT Capacitor bank)
Supply & Erection of Earthing for Panel and LA's by pipe in pipe earthing(3.96 MVAr HT Capacitor bank)
Casting of Civil foundation(3.96 MVAr HT Capacitor bank)
Cable trench for laying of power/control cables.(3.96 MVAr HT Capacitor bank)
Supply & Erection of Earthing of existing substation and Distribution Transformer
Supply & Erection of Pipe rod earthing with 3000mm long, 40 mm diameter GI pipe, GI Strip of 24x3mm.
Supply & Erection of Spike Earthing 20mm X 2500 mm GI solid Rod
Supply & Erection of 8 SWG GI wire for earthing
Supply ,Erection,Design & Engineering of Renovation and Modernization of Existing Substation, Battery Charger and Battery set
Supply & Erection of 24V, 150 AH Pb(Lead) Acid battery, battery stand made of teak wood duly painted with anti acid resistive paint, battery insulators, inter-battery wiring using 30 sqm, 1.1 kv, copper single core multi strand cable, terminal connectors, Rubber mats & all other accessories and connectors as per technical specifications.
Supply & Erection of 24V, 150 AH. Float-cum-Boost Battery Charger with full wave rectification for 230 V, 1 phase, 50 Hz AC Input Supply & Erection as per technical specifications.
Supply & Erection of36kV, 1250A, 25kA for 3 seconds, 3-ph, Outdoor type Vacuum Circuit breaker with marshalling box etc Complete in all respect along with support structure.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 400-200/1-1 Amps ( having 3 secondery, core), type Current Transformers along with junction box (1 no junction box for 3 no of 1- phase CTs), as required as per technical specifications complete in all respect.
Supply & Erection of 36kV, 1-Phase, 25kA/3 seconds, 33 Kv/110 V single core outdoor type Potential Transformers along with junction box, as required as per technical specifications complete in all respect.
Supply & Erection of 30 kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 set= 3 Nos.)
Supply & Erectio of 36kV, 800A, 25kA , 3-ph double break center rotating type (DBCR), Gang Operated, isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per Technical Specifications. (with Earth Switch)
Supply & Erection of 33 kV feeder Panel (without diffirential relays) complete
Supply & Erection of 12 KV 3 Ph 1250 A, 25kA for 3 seconds, 3-ph, indoor type Vacuum Circuit breaker along with 12 kV, 1-Phase, 25kA, 400-200/5-5 A, 3 Nos indoor type Current Transformer, indoor mounting type control panel for feeder protection and required accessories, A-meter, Numerical Relay & accessories complete as per specifications for feeder breaker protection & Protection for Earth fault and over current) with extensible arrangement for future
Supply & Erection of 11 KV 400-200/5-5 AMP moulded CT
Supply & Erection of Indoor Type 11KV/110/√3 V 3-Phase PT for Indoor Type Control & Relay panel
Supply & Erection of 9kV, 10kA, 1-ph Station Class Lightening Arrester complete (1 Set = 3 Nos.)
Suplly & Erection of 11KV TPMO switch with fixing clamps,chanel & Nut & bolt.
Supply & Erection of 11 kv Bus-Coupler with all required accessories complete as per technical specifications, scope of works and approved drawings .
Supply of 3CX300 Sqmm 33 KV XLPE Armored Cable
Erection of 3CX300 Sqmm 33 KV XLPE Armored Cable
Supply of 3Cx185 Sqmm 11 KV XLPE Armored Cable
Erection of 3Cx185 Sqmm 11 KV XLPE Armored Cable
Civil Works for Control room extension, Strengthning and Miscellaneous Works required as per Scope of work, Approved drawings and Technical Specifications.
Design, Engineering construction of Control room building extension 300 Sq feet for installation of Capacitor Bank pannel, including cost of all materials, T&P and Labour, etc. as per Technical specification and approved drawing as per direction of Employer
Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for additional T/F, including cost of all materials, T&P and Labour, etc. as per Technical specification and approved drawing as per direction of Employer
Design, Engineering construction of Control room building extension 300 Sq feet for installation of pannels for Augmentation of T/F, including cost of all materials, T&P and Labour, etc. as per Technical specification and approved drawing as per direction of Employer
Old Conrol Room Building Strengthning & Miscellaneous Construction Works required as per Scope of work, Approved Drawings and Technical Specifications
Construction of boundary wall (200 mtr for each substation) as per Scope of work, approved drawings and Technical specifications.
Construction of fire wall between two Power Transformes at Existing 33/11 KV S/S as per Scope of work, approved drawings and Technical specifications.
Supply & Erection of DT Capacitor with Fitting as per Technical Specification, Approved Drawing and scope of work
Supply & Erection of LT Shunt capacitor 440 Volt 10 KVAr 3Phase 50Hz IP65
Supply & Erection of LT Shunt capacitor 440 Volt 25 KVAr 3Phase 50Hz IP65
LT Line with 1CX25 sqmm LT armoured XLPE Cable in high loss area
Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31
Grouting of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work
Supply & Erection of Stone Pad 300X300X75
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Erection of complete stay set with 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of Single core XLPE armoured cable single phase 2 wire as per technical specifications, approved drawings and scope of work.
Supply & Erectio of 1.1 kV Single Core 25sqmm XLPE armoured cable (1Cx25 sqmm)
Supply & Erection of Angle for vertical Arm L50x50x6 (Type -A)-900MM
Supply & Erection Angle for vertical Arm L50x50x6 (Type -B)- 900MM
Supply & Erection of C-Clamp with Nut & bolts
Supply & Erection of LT shakle insulator
Supply & Erection of Distribution tie for shakle insulator
Supply & Erection of Mid span joint 25sqmm
Supply & Erection of Insulation mastic tape (2inc X 10 feet).
Supply & Erection of Satellite Multi-Tap Connector as per TS
Supply & Erection of Single Phase SMC Distribution Box with clamps
Supply & Erection of 2Cx25 SQMM Stranded Unarmoured Cable (Al Conductor ) for charging Single Phase DB
Supply & Erection of Spike Earthing 20mm X 2500 mm GI solid Rod
Supply & Erection of 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Removing and shifting of Existing Material to client store
LT Line with 1CX120 sqmm LT XLPE Armoured Cable in high loss area
Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31
Grouting of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work
Supply & Erection of Stone Pad 300X300X75
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Grouting stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of Single core XLPE armoured cable for three pahse 4 wire as per technical specifications, approved drawings and scope of work.
Supply & Erection of 1.1 kV Single Core 120sqmm XLPE armoured cable (1Cx120 sqmm)
Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg) with Nuts and bolts
Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts
Supply & Erection of C-Clamp with Nut & bolts
Supply & Erection of LT shakle insulator
Supply & Erection of Distribution tie for shakle insulator
Supply & Erection of Mid span joint 120sqmm
Supply & Erection of Insulation mastic tape (2inc X 10 feet).
Supply & Erection of Satellite Multi-Tap Connector as per TS
Supply & Erection of Three Phase SMC Distribution Box with clamps
Suppply & Erection of 4Cx35 SQMM Stranded Unarmoured Cable (Al Conductor ) for charging Three Phase DB
Supply & Erection of Spike Earthing 20mm X 2500 mm GI solid Rod
Supply & Erection of 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Removing and shifting of Existing Material to client store
LT Line with 1CX95 sqmm XLPE Armoured Cable in high loss area
Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31
Grouting of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work
Supply & Erection of Stone Pad 300X300X75
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Grouting stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of Single core XLPE armoured cable for three phase 4 wire as per technical specifications, approved drawings and scope of work.
Supply & Erectionof 1.1 kV Single Core 95sqmm XLPE armoured cable (1Cx95 sqmm)
Suppl & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg) with Nuts and bolts
Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts
Supply & Erection of C-Clamp with Nut & bolts
Supply & Erection of LT shakle insulator
Supply & Erection of Distribution tie for shakle insulator
Supply & Erection of Mid span joint 95sqmm
Supply & Erection of Insulation mastic tape (2inc X 10 feet).
Supply & Erection of Satellite Multi-Tap Connector as per TS
Supply & Eection of Three Phase SMC Distribution Box with clamps
Suppply of 4Cx35 SQMM Stranded Unarmoured Cable (Al Conductor ) for charging Three Phase DB
Supply & Erection of Spike Earthing 20mm X 2500 mm GI solid Rod
Supply & Erection of 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Removing and shifting of Existing Material to client store
LT Line with 1CX50 sqmm XLPE Armoured Cable in high loss area
Supply & Erection of 8.5 m/180 kgs PCC Poles (PCC Pole as per state practice)
Supply & Erection of 9 M long steel Tubular poles with welded steel base plate of Designation 410 SP 31
Grouting of 8.5 m/180 Kgs PCC Poles with Base pad including Cement concreting, (state practices of PCC pole, stone to be used)
Concreting of supports with Grounting of 0.294 cum (1:2:4,1-cement, 2-coarse sand,4-concerate of 20mm Size) of 9mtr mtr STP Pole of depth 1.5 meter with 300 mm Muffing.As per TS.
Supply & Erection of Pole accessories as per technical specification, approved drawing and scope of work
Supply & Erection of Stone Pad 300X300X75
Supply & Erection of Stay Set (Galvanized) with 50x8 mm stay clamp, stay guy insulator (1 Nos.), anchor plate (200x200x6), nut bolts, 1 Nos turn-buckles, 1.8 m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete as per technical specification, approved drawings and scope of work.
Grouting of stay set with GI stay wire (7x3.15 mm dia), binding of stay wire, by providing Guy stay insulator (1 no.) and 0.2 cmt concreting 1 part cement, 2 part sand, 4 part 40 mm size stone aggregate chips (1:2:4) as per technical specifications, approved drawings and scope of works.
Supply & Erection of Single core XLPE armoured cable for three pahse 4 wire as per technical specifications, approved drawings and scope of work.
Supply & Erection of 1.1 kV Single Core 50sqmm XLPE armoured cable (1Cx50 sqmm)
Supply & Erection of LT cross arm arrangement angel (50x50x6mm) (50x8mm) (weight-9.41 kg) with Nuts and bolts
Supply & Erection of LT cross arm arrangement angel (75x75x8mm) (65x8mm) (weight-18.6 kg) with Nuts and bolts
Supply & erection of C-Clamp with Nut & bolts
Supply & Erection of LT shakle insulator
Supply & Erection of Distribution tie for shakle insulator
Supply & Erection of Mid span joint 50sqmm
Supply & Erection of Insulation mastic tape (2inc X 10 feet).
Supply & Erection of Satellite Multi-Tap Connector as per TS
Supply & Erection of Three Phase SMC Distribution Box with clamps
Suppply & Erection of 4Cx35 SQMM Stranded Unarmoured Cable (Al Conductor ) for charging Three Phase DB
Supply & Erection of Spike Earthing 20mm X 2500 mm GI solid Rod
Supply & Erection of 8 SWG GI wire for pole,DB earthing with GI nuts, bolts & washers
Supply & Erection of LT insulation Piercing Connectors of 16-150 sqmm size for energizing distibution Kiosk/box
Supply & Painting of silver paint
Supply & Painting of red oxide paint
Removing and shifting of Existing Material to client store
LASER POWER AND INFRA PVT. LTD (BID ID -4620894)
Montecarlo Limited (BID ID -4622035)
Lumino Industries Limited (BID ID -4624079)
Jakson Limited (BID ID -4634277)
LARSEN AND TOUBRO LIMITED (BID ID -4655600)
Bidder Name
Jakson Limited
CAPITAL ELECTECH PVT LTD
LASER POWER AND INFRA PVT. LTD
Lumino Industries Limited
Montecarlo Limited
LARSEN AND TOUBRO LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
153265991.pdf
Tender Documents • 1.52 MB
153265992.html
Tender Documents • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .