Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹24.8 LAccepted-AOC PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹27.0 L+₹1.2 L (4.55%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹30.1 L+₹4.3 L (16.6%)Rejected-Finance | L-3 | Rejected-Finance L-3 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
13 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) FARIDABAD
GE (AF) FARIDABAD
CERTAIN REPAIRS TO B/R E/M SERVICES FOR CAMP AREA IN AOR OF GE (AF) FARIDABAD UNDER GE (AF) FARIDABAD (2ND CALL)
2022_MES_548420_2
GE (FBD)/AF-39/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹50,000
Yes
21 Nov 2022
30 Sept 2022
15 Oct 2022
30 Sept 2022
13 Oct 2022
30 Sept 2022
Amount
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 above but except bricks complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Checking of floor, plinth, plaster etc requiring masonry work and carrying out minor repairs such as edges patches etc, including petty repairs material like sand, cement & aggregate to make it functional complete all as specified and directed by Engineer-in-Charge. Any items required to be replaced or major repair shall be repair under respective items.
Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed by Engineer-in-Charge.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual at any height etc complete all as specified and directed by Engineer-in-Charge. (WPC will be measured and paid separately).
Supply only liquid WPC complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 5 mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/old surfaces on walls, pillars cornices etc surfaces by spray gun machine incl by complete removal of existing sureface & filling necessary putty where required as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of plastic emultion paint in internal wall surface on wall over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surface & apply two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of plastic emultion paint on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of plastic emultion paint over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of plastic emultion paint on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge.
M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed by Engineer-in-Charge.
M&L for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance and complete all as specified and directed by Engineer-in-Charge.
M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl preparation of new plasterd surface complete all as specified and directed by Engineer-in-Charge. Note : Colour and make as approved by Engr-in-Charge.
M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of oil emulsion distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatmen and applying one coat of oil emulsion distemper over a coat of primer on surface of walls through electrical operated grinder etc, complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatment and apply two coats of cement based paint over a coat alkali primer resistance etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatment and apply one coat of cement based paint over a coat alkali primer resistance etc complete all as specified and directed by Engineer-in-Charge.
M&L for applying two coat of Acrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray gun machine incl by complete removal of existing sureface & filling necessary putty where required as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of Acrylic smooth exterior emulsion paint on walls, pillars cornices etc surfaces by spray gun machine incl by complete removal of existing sureface & filling necessary putty where required as in pathces or nail holes obtain smooth finish using sand paper and matching the existing surface complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces by removal of existing treatment and applying one coat of distemper oil emulsion on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces and applying two coats of white washing on wall complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces and applying one coat of white washing on wall complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces and applying two coats of white washing on ceiling complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces and applying one coat of white washing on ceiling complete all as specified and directed by Engineer-in-Charge.
M&L for providing RCC nominal mix 1:2:4 incl necessary formwork and providing plaster in cement mortar 1:3 and two coats of finishes over a coat of primer for RCC projected portion as in facias, fins upto a height of 30 cm facia etc incl demolition of existing and providing TMT bars if reqd complete all as specified and directed by Engineer-in-Charge.. (Note length of fins, facias shall be measured irrespective of any thickness and height).
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the mild steel wire (annealed) not less than 0.9mm dia or securing with clips and complete all as specified and directed by Engineer-in-Charge.
All as per item No 41 above but 6 to 8 mm dia and over and including in stirrups, spacers and binders and complete all as specified and directed by Engineer-in-Charge.
M&L for reparing of RCC projection, chajja, roof facia, celling by scrapping, cutting, derusting and cleaning exposed reinforcement surfaces of damaged loose RCC surface and applying neat cement slurry @ 3 kg/Sqm and filling the surface with cement plaster 1:3 one or two layer as reqd or PCC 1:2:4 as directed by Engr-in-Charge with or without facia and smooth finished and smotth edges incl two coats of finished to match with the existing surface at any height and in any situation including necessary form work complete all as specified and directed by Engineer-in-Charge.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) n.exc 1.5 Sqm each including cutting holes for taking out hold fasts, dismantling brick work (holes cut and any other damages to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost) complete all as specified and directed by Engineer-in-Charge.
All as per srl item No 43 above but exc 1.50 Sqm and not exc. 4.00 Sqm complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description n. exceeding 1 square metre each complete all as specified and directed by Engineer-in-Charge.
Refixing in same opening of shutters of any description n. exceeding 1 square metre each incl easing, adjusting and renewal of screws complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exceeding 1 square metre but n. exc 2 sqm each complete all as specified and directed by Engineer-in-Charge.
Refixing in same opening of shutters of any description exceeding 1 square metre but n. exc 2 Sqm each incl easing, adjusting and renewal of screws complete all as specified and directed by Engineer-in-Charge.
M&L for pressed steel frames of size 105mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, incl taking down old frame/chowkat complete all as specified and directed by Engineer-in-Charge.
All as per item No 49 above item but here-in size of frame 125mmx60mm for doors complete all as specified and directed by Engineer-in-Charge.
S&F for factory made 35mm thick 2nd class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
S&F for 35mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping/frame to match incl taking down old shutter complete all as specified and directed by Engineer-in-Charge.
S&F for 2nd class H.W. glazed and skelton door shutters 35mm thick, open rebated and prepared to received glass/gauge etc (without sash bars) edges of framing plain, chamfered or rounded and mitred , beads for securing glass etc the size of member of shutter as specified in SSR part-I clause 8.23(b) and fitted to chowkahts incl stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads & taking down old shutter etc complete all as specified and directed by Engineer-in-Charge.
S & F solid PVC door frame of size 50 x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube incl taking down old frame any type complete all as specified and directed by Engineer-in-Charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be convered with heat moulded plain colour PVC `C' channel having a PVC sheet strip of 20 mm width stuck inside with solvant cement for stiles and plain colour PVC sheet top rail, lock rail and bottom rail on either side and as gap insert of top rail and bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and raials with suitabale PVC sheet beading, and jointed together with solvant cement, fixing in the frame at side as per specification and drawing incl taking down old shutter & 3Nos- 100mm Aluminium hinges for each shutter complete all as specified and directed by Engineer-in-Charge.
M&L for box type steel window 1.25 mm thick made of ERW tube P-Section of size 60 x 25 mm double rebated outer frame comprise of glazed skeleton shutter(two gauged shutters and two glazed shutter) of ERW tube P-Section size 50 x 20 mm and 1mm thick one/two Nos openable leaf consisting of two Nos sash bar of T-Section 20x3mm welded to frame with one No Vertical mullion of ERW box type T-Section of size 60 x 25 mm and 1.25 mm thick and FI 2 mm thick welded / screwed to frame for fixing of glass including fittings and fixture like Handle, Tower Bolt, stopper, cleat, pintal hinges, hold fast etc. (i) Hold Fast, 150mm long of 120mm x 3 mm made to shape -04 Nos per window. (ii) Handle of Z sec 20mm x 25mm, 100 mm long -1 No per leaf (iii) MS Tower bolt 150mm long - 2 No per leaf (iv) Z Sec 20mm x 25 mm, 100 mm long stopper - 1 No per leaf (v) Cleat 55 mm long of hollow square 15mm x 20mm x.63mm welded to hinge -1 No per leaf. (vi) MS Pintal hinges of size 75mm x 12mm - 2 Nos per leaf . (vii) 8 mm square guard bar, 10 cm centre to centre. (viii) 40x6 mm flat iron all around for joint of both frame. (ix) stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples & 3mm thick, sheet glass ordinary quality and glazing with oil putty .(x) Two coat of synthetic enamel paint to MS window and guard bar , Incl taking down old steel / wooden window and making good dismantled portion with PCC 1:2:4 type B0 incl hold fast PCC (four No’s for Each window) & around required plaster in CM 1:4 and match with existing finishing complete all as specified and directed by Engineer-in-Charge.
S & F for Steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed by Engineer-in-Charge.
S & F for 3mm thick sheet glass ordinary quality glazing with oil putty in square n exc 0.5 sqm quality or description from steel frame and complete all as specified and directed by Engineer-in-Charge.
S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bar and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
M&L for anodised aluminium powder coated framed work for door, window / vent (powder coated) aluminium section weighting 0.55kg/RM with one or more rebated incl jointed cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
M&L Anodised aluminium powder coated window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 to 5.5mm thick float glass ordinary quality, glazing or black with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed by Engineer-in-Charge.
S & F in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
Easing andAdjusting aluminium door and window including refixing beading after replacement of defective portions such as door closer, aluminium handles, hinges, locks, new rubber gasket, aluminium beading, preleminated prarticle board, sheet glass etc complete all as specified and directed by Engineer-in-Charge. Notes : Door closer, door spring, aluminium beading, preleminated gasket, aluminum beading, preleminated particle board, sheet glass shall be measured and paid separately under respective item of schedules.
S&F of 12 mm thick particle board preleminated on both side decorative choice etc complete all as specified and directed by Engineer-in-Charge.
S&F of floor door spring etc complete all as specified and directed by Engineer-in-Charge.
S&F of door closer hydraulically regulated design No 2etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron body Door closer hydrau?lically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed by Engineer-in-Charge.
S&F of Mortice lock vertical type 4 lever etc complete all as specified and as directed etc complete all as specified and directed by Engineer-in-Charge.
S&F of Neoprene/EPDM Rubber gasket for fixing aluminium door and window shutters etc complete all as specified and directed by Engineer-in-Charge.
S&F of aluminium beading for fixing of aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F of 150 mm long aluminium tower bolts for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F of aluminium handles 150 mm long for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F of aluminium handles 100 mm long for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair 2nd class hard wood beading straight (any size) for glazed/gauged joinery, renewed incl mitered etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair door seals made of aluminium strip powder coated 20 mm wide and provided rubber/ cotton mat lining fixed with screws to door shutters up to 1m width opening complete all as specified and directed by Engineer-in-Charge.
S&F double legged door stopper of aluminium alloy with rubber complete all as specified and directed by Engineer-in-Charge.
M&L for extruded brass handle, fancy type as approved by the GE, polished, 150mm long (ISI marked), complete all as specified and directed by Engineer-in-Charge.
M&L for continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified and directed by Engineer-in-Charge.
S&F for mild steel cold rolled butt hinges medium weight 75 mm long , including fixing to pressed steel door frame.cupboard & Almirah if required complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium Fanlight catch with 14mm catch and fixed suitable for any shutters complete all as specified and directed by Engineer-in-Charge.
S&F for aluminum handles cast type anodized 200mm long (ISI Marked) complete all as specified and directed by Engineer-in-Charge.
S&F for 250mm long aluminium alloy, anodised, sliding door bolt of 16mm dia with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified and directed by Engineer-in-Charge.
S&F in repair for 25 mm dia decorative/fancy type stainless steel curtain rod with brackets and knobs at both ends as per site requirement incl taking down old existing pipes with accessories complete all as specified and directed by Engineer-in-Charge.. Note: the cost of brackets and knobs is deemed to be incl in the quoted rate.
S&F in repair, 150 mm ordinay rat tail rod pattern springs incl roller and rabber plate fixed to chowkhats in repairs incl necessary welding if reqd complete all as specified and directed by Engineer-in-Charge.
S&F for 3mm thick figured glass, pin head type and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F in repair mild steel, chromium plated curtain rod cut to size 20mm dia with holder/bracket, stops, rollers etc, complete fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S & F in repair 3mm thick sheet glass, ordinary quality and with oil putty in Square n. exc 0.5 sqm in each pane incl hacking out old broken glass from metal/wooden frame incl punching or drilling out old glazing pins/spring clips and glazed with oil putty complete complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
S & F in repair for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples or wooden beads complete all as specified and directed by Engineer-in-Charge.
M&L in repair for PVC hollow wall panelling 7 to 8mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site incl dismantling of panelling complete all as specified and directed by Engineer-in-Charge.
Dismantling of steel sheet (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as specified and directed by Engineer-in-Charge.
S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality complete all as specified and directed by Engineer-in-Charge.
All as per item 95 above but fixing only complete all as specified and directed by Engineer-in-Charge.
Mild steel framed work such as grills, gratings,etc, with ends of bars shouldered and/ or riveted or forged into spikes, framed guard bar ; barred iron doors, ladder ; framed balusters ; railing ; frame work for water tanks and similar work conforming to Fe-410,Gde-E-310, complete all as specified and directed by Engineer-in-Charge.
S&F for Framed work as in cupboard, almirah and ceiling frame of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering. etc. to be prepered for hanging or sliding with hinges also fastening and fixing complete all as specified and directed by Engineer-in-Charge.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
fixing only for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Fixing only for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
S & F dor plain gypsum board panel 12.5mm thick on ceiling with and incl necessary GI frame used with ' T ' or any section accessories etc of galvanized steel all as per manufacturer design conforming to IS-2095 and 2542(1981) the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type and two coat of OBD over a coat of putty complete all as specified and directed by Engineer-in-Charge.
M&L for providing and fixing 10 mm thick plaster of paris ceiling (Gypsum anhydrous) of approved design/pattern to flat surfaces incl all necessary MS frame work, 12 mm thick board and fittings as per standard practice and as per manufacturer's instrs reinforced with GI wire mesh incl dismantling of walls and ceiling board any type complete all as specified and directed by Engineer-in-Charge.
Checking and attending to water leakage from taps, flushing cisterns, wash hand basins and other sanitary fittings/fixtures and any obstruction to water supply, requiring plumber work and carryout minor repairs such as replacement of washers, check nuts, tightening of fittings of flushing cistern etc including petty materials like washers of all sizes, thread(shoot), M-seal, screws, nails to make water supply/ plumbing lines functional and leak proof complete all as specified and directed by Engineer-in-Charge. Note Any items required to be replaced shall be paid under respective items
Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed by Engineer-in-Charge.
S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed by Engineer-in-Charge.
Fixing only in repair steel tubing and connection 15 mm dia bore to wall and laid in floors complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed by Engineer-in-Charge.
S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
Fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors complete all as specified and directed by Engineer-in-Charge.
S&Fin repair for Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15 mm bore Twin one angle valve/ bib tap cast copper alloy chromium plated, fancy type, screwed down high pressure, screwed both ends for iron pipe or for union complete all as specified and directed by Engineer-in-Charge.
S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed by Engineer-in-Charge.
S&F in repair corner shelf with CP railing 300mm x 300mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair CP jet for EWC along with pvc connectioncomplete all as specified and directed by Engineer-in-Charge.
S&F for liquid soap container of PTMT fixed with and incl CP brass screws and wooden/plastic cleats complete all as specified and directed by Engineer-in-Charge.
S & F for Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe in repairs complete with all fittings complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stop cock /angle CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed by Engineer-in-Charge.
S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed by Engineer-in-Charge.
S& F for swan neck pillar cock fancy type chromium plated screw with iron pipe incl all fittings in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for PVC connections 60cm long superior quality with PTMT nut on both side complete all as specified and directed by Engineer-in-Charge.
S&F in repair grating round 125mm size of CP complete all as specified and directed by Engineer-in-Charge.
S&F in repair 32 mm dia Waste coupling of PTMT (half or full threaded) suiotable for urinal . (Minimum weight 32mm?45gms )complete all as specified and directed by Engineer-in-Charge.
S & F in repair vitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, CP urinal spreader and fitting with bottel trap & CP waste coupling all as specified and approved by Enger-in-Charge.
S&F in repair PVC water tank lid with locking arrangement complete capacity (500 ltr -1000 Ltr) complete all as specified and directed by Engineer-in-Charge.
S&F in repair for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repair for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for Brass chromium plated Tubular towel rail, 20mm dia, D type, 60cm long between flanges and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed by Engineer-in-Charge.
S&F for Towel ring brass chromium plated, fixed with brass screws and plugs complete all as specified and directed by Engineer-in-Charge.
S&F for Brass Chromium plated shower roses 125 mm size incl arm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stainless steel sink without drainboard, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc., overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm etc complete all as specified and directed by Engineer-in-Charge.
S&F in repair sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe incl sink coupling, 40mm waste fitting, overall size915mmx460mm with bowl size 410 mm x 330mm x 160mm, etc complete all as specified and directed by Engineer-in-Charge.
S&F for Toilet paper holder,stainless steel, fixed with and including chromium plated brass screws and and wooden/plastic cleats on walls complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Health faucet brass CP with 8mm dia 1.2 mtr long flexible pipe and wall hook fixed with brass chromium plated screws, complete all as specified and directed by Engineer-in-Charge.
S&F in repair for Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/40mm-270 gms), complete all as specified and directed by Engineer-in-Charge.
M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engr-in-charge.
Fixing only for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed by Engr-in-charge.
S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed by Engineer-in-Charge.
Fixing only for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed by Engineer-in-Charge.
S&F of PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400 mm incl brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
fixing only for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400 mm incl brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for One piece water closet with bowl for cupled WC with PP soft seat cover, cistern hinges fixing accessories and accessories set of size 650x375x750mm, 3.S trap outlet with cistern fittings and necessary fixing fittings complete, fixed in repairs, complete all as specified and directed by Engineer-in-Charge.
S&F for wall mixer with provision for overhead showes with 115mm long bend pipe on upper side, connecting legs and wall flanges, in repairs complete all as specified and directed by Engineer-in-Charge.
S&F for CP brass Centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, in repairs complete all as specified and directed by Engineer-in-Charge.
M&L in repair cast Iron floor trap with dia of outlet 75mm with CI grating including jointing to waste pipe fixed in cement concrete PCC 1:2:4 type B-1 complete all as specified and directed by Engineer-in-Charge.
All as per item No 148 above but 100mm complete all as specified and directed by Engineer-in-Charge.
S&F for steel locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia , 100mm size complete all as specified and directed by Engineer-in-Charge.
S&F in repair flush pipe of PVC, 32mm dia, for low level cistern complete all as specified and directed by Engineer-in-Charge.
Supply only flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern complete all as specified and directed by Engineer-in-Charge.
S&F in repair plate rack made of stainless steel 785x760x250x0.63mm including fixing as per manufacturers instruction complete all as specified and directed by Engineer-in-Charge.
S&F in repair stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore, complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engineer-in-Charge.
S&F in repair, 32/40mm dia waste coupling fittings brass chromium plated for glazed ware sink, basins,etc with long screwed shank and fly nuts, flanges end bedded in red lead cement and other end fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stainless steel grating doom 100 mm dia of PTMT (minimum weight 25 gms) but in repair complete all as specified and directed by Engineer-in-Charge.
S&F in repair 32/40 mm dia PVC waste pipe for WHB/sink, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing "as in repair" ball valves of size 20mm bore dia high pressure of PTMT (Make-Prayag) with epoxy coated aluminium rod and high density plastic ball (Minimum weight not less than 210 gms) screwed for iron pipe and fixed including necessary fitting as reqd at site complete all as specified and directed by Engr-in-Charge
Supply and fixing "as in repair" stop valves/angle valve of 15 mm bore, but fancy type, chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions including necessary fitting as required at site complete all as specified and directed by Engr-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required of internal dia of pipe 50/75/100 mm complete all as specified and directed by Engineer-in-Charge.
M&L for 100 mm bore cast iron soil, sand cast, waste and vent pipes in any length with or without ears, with cement joints fixed to walls complete all as specified and directed by Engineer-in-Charge.
All as per item No 162 above but except pipe, any type complete all as specified and directed by Engineer-in-Charge.
S&F for cast iron soil, waste and vent pipes in any length with or without ears, with cement joints fixed to walls, 75mm dia, sand cast pipes including two coats of black Japan paint complete all as specified and directed by Engineer-in-Charge.
All as per item No 164 above but except pipe, any type complete all as specified and directed by Engineer-in-Charge.
M&L 50 mm bore cast iron soil, sand cast, waste and vent pipes in any length with or without ears, with cement joints fixed to wall, complete all as specified and directed by Engineer-in-Charge.
All as per item No 166 above, but except pipe, any type complete all as specified and directed by Engineer-in-Charge.
M&L 100 mm bore cast iron soil, sand cast, waste and vent pipes in any length with or without ears, with cement joints laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
All as per item No 168 above but 75mm dia complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron bends (any radius) with for 75mm bore fitted with oval access doors complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron bends (any radius),diminishing pieces or tapers (larger bore measured) for 100mm bore fitted with oval access doors complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron branch pieces, single (equal of unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 100mm bore fitted oval access door complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron cowl suitable for pipes of 50mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair cast iron cowl suitable for pipes of 75mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair Stack clamps made out of 50mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 100mm bore complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete unreinforced in of any desciption and in any position not otherwise specifically provided for (sunken floor) and concrete debris and rubbishoff to a distance n exc 100m complete all as specified and directed by Engineer-in-Charge.
M&L, for rendering 10mm thick in CM 1:3 with WPC in sunken slab complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed by Engineer-in-Charge.
M&L, cement concrete 1:7:12 F-2 (40 mm graded aggregate ) in lean concrete complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length "medium grade " with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings all as specified and directed by Engineer-in-Charge.
All as per ser item No 180 above but laid in trench or in floor complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC Gully Trap setting / jointed with solvent cement complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
All as per item 184 above but here- in area of each tile exe 0.11 sqm but n.exe 0.18 sqm, in floors & dado etc complete all as specified and directed by Engineer-in-Charge.
M& L for Glazed ceramic jointless light/coloured group of size 350mmx450mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by EIC/GE
M&L for Virified tiles light shade /dark shade 10 mm thick (square/ rectangular) polished, area of each tiles not exc 0.36 sqm , in floors, dado , skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling tiles etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 187 above but here-in- area of each tiles exc 0.36 sqm but not exc 0.42 sqm, in floors & dado complete all as specified and directed by Engineer-in-Charge.
M&L for 20 to 25 mm thick Kota stone slab (Machine cut) of any size laid over and incl 20mm thick bedding layer in cement mortar 1:6 over neat cement slurry @ 3Kg/sqm over sub base , jointed and pointed in grey cement mixed with pigment to match the shade of slab including rubbing and polishing to achieve mirror finish complete as in flooring /steps/ riser / skirting incl dismantling stone slabs etc complete all as specified and directed by Engineer-in-Charge.
M&L for Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana white incl roundening the edge of stone complete all as spd and directed.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing and dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor finishes incl demolition complete all as specified and directed by Engineer-in-Charge.
M & L for 100mm thick PCC 1:2:4 type B-2 (using 40 mm agg. ) in hardstanding /base of flooring incl demolition complete all as specified and directed by Engineer-in-Charge.
M & L for 75 mm thick PCC 1:4:8 type D-2 (using 40 mm agg. ) in sub base of flooring incl demolition complete all as specified and directed by Engineer-in-Charge.
M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area incl demolition complete all as specified and directed by Engineer-in-Charge.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for machine pressed precast concrete interlocking paver block of 60mm thickness any shape and size confirming to IS 15658 -2006, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed by Engineer-in-Charge.
Except machine pressed precast concrete interlocking paver block of 60mm thickness any shape and size confirming to IS 15658 -2006, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed by Engineer-in-Charge.
M & L broken stone hard core of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed by Engineer-in-Charge.
M&L for precast cement concrete type B0 1:2:4 (12.5mm graded agg) louvers and jallies set in CM 1:4, 25mm thk including all mouldings incl dismantlling but excluding frame complete all as specified and directed by Engineer-in-Charge.
Cleaning and removing all scale and dirt etc from over head water tanks and mouth of circulating pipe etc of capacity up to 500 ltr using bleaching & refixing in the same position complete all as specified and directed.Note:- Date of cleaning write on tank with paint complete all as specified and directed by Engineer-in-Charge.
All as per item No 202 above but capacity up to 1000 ltr using bleaching & refixing in the same position complete all as specified and directed by Engineer-in-Charge. Note :- 1. Contractor shall be bounded to carryout repair / maint upto G+3 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories. Note 2. (a) Contractors representative /Engineer will report to Engr-in-Charge / concerned JE daily in morning to collect complaint for routine / urgent works related to day to day maint till completion of contract. (b) All routine day to day / urgent jobs received on docket slip shall be attended within 24 hrs. If the nature of job is such that which can not be completed within 24 hrs, it shall be immediately brought in to the notice of Engr-in-charge. (c) The period for working to the such complaints shall be decided by GE/Engr-in-Charge. If delay is more than 24 hrs and GE/Engr –in-charge is not satisfied with reason for delay in working then the penalty of Rs 350/- per complain per day shall be recovered from the Contractor. (d) In case of any dispute arising from above, the decision GE shall be final and binding.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including all electrical fittings & fixtures(DBs, submain,cables etc) and making good disturbed surfaces of wall , floor etc and matching wth original colour of wall, complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and in existing concealed / surface PVC Conduit/ saddle medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet (Make: Hylam) for provision of switches/regulators as per specified SSR and as directed by Engineer- in- Charge. NOTE:-After rewiring cutting chasing portion should be matched with existing finishes of walls..
All as per item No 205 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer-in-Charge.
All as per item No 205 above but on the same board complete all as specified and directed by Engineer-in-Charge.
All as per item No 205 above but for one bell/Buzzer point controlled by one push button on the same board with other switches or independent with 1.50 sqmm size cable complete all as specified and directed by Engineer-in-Charge.
All as per item No 205 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of switch 15 Amps SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of socket outlet 2-in-1, 3 pin 5 amps and 15 amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of stepped type electronic fan regulator flush type on the existing phenolic sheet etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for modular switches 6 amps single pole one way complete all as specified and directed by Engr-in-charge.
S&F in replacement for modular sockets out let 6 amps 6 pin 2 module with shutter complete all as specified and directedby Engr-in-charge.
S&F in replacement for modular switches 16 Amps single pole one way complete all as specified and directed.by Engr-in-charge.
S&Fin replacement modular socket out let 6-16 Amps 3 pin combined shuttered complete all as specified and directed by Engr-in-charge.
Supply & fixing in replacement of ding dong bell electric 230 volt AC complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of SPN enclosure with two pin and earth plug and socket complete with on SP MCB 25 Amps complete all as specified and directed by Engineer-in-Charge.
M&L PVC insulated FRLS single core with strandard copper cable of size 6 Sqmm in two run and 4 Sqmm one run for earth and drawing through existing concealed conduit including taking down old UNSV cable complete all as specified and directed by Engineer-in-Charge. NOTE :- 2 runs of 6 Sqmm cable and one run of 4 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
All as per item No 49 above here-in-before but copper cable single core of size 4 Sqmm in two run with earth wire 2.5 Sqmm single run for continuity complete all as specified and directed by Engineer-in-Charge. NOTE :- 2 runs of 4 Sqmm cable and one run of 2.5 sqmm cable will be measured as one running meter for the purpose of measurement and payment.
Supply and Fixing LED street light fitting 60 Watt pressure die case aluminium housing LED street light luminaires suitable for existing street light pole including all fixing accessaries all as per specified and directed by Engineer-in-Charge.
S& fixing LED flood light luminarie 70 W 5000 K with high pressure die cast housing acting as heat sink in order to ensure better performance having IP66 ingress protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement post top lantern LED 40 W or next highest wattage having IP65 protction for single phase connection 50 Hz 230 Volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of bulb LED with B22 base 9 Watt pin type or holder type of warm white complete all as specified and directed by Engineer-in-Charge
S&F in replacement wall mounting box type LED tube light fitting , extruded aluminium heat sink provided for efficient heat dissipation & Integrated electronic driver 1x20 watt comprising of strong jointless CRCA body complete with all accessories and all as specified and directed by Engr-in-Charge.
M&L for Recess mounted 36/ 40 Watt high efficancy 2x2 recess LED flat panel with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge .
M&L for Recess mounted 15 Watt high efficancy recess LED slim square downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge .
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge.
Supply and fixing bed-side wall mounted LED 3 W 3000k warm white with high efficienc LED and clear diffuser IP20 all as specified and complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out all as specified and directed by Engineer-in-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm apart all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection all as specified and directed by Engineer-in-Charge.
Taking down/ out XLPE PVC insulated LT cable 1100 Volts grade from loose / hard soil / of any size all as specified and directed by Engineer-in-Charge.
Supplying, laying and testing XLPE cable, insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 volts grade (Heavy Duty) with stranded aluminium conducotr of cross secional area 10 Sqmm 4 core all as specified and directed by Engineer-in-Charge.
Supplying, laying and testing XLPE cable, insulated screened PVC bedded galvanised steel strip or wire armoured LT 1100 volts grade (Heavy Duty) with stranded aluminium conducotr of cross secional area 25 Sqmm 4 core all as specified and directed by Engineer-in-Charge.
M&L for 40mm dia of light grade GI pipe laid under road/floor/on pole for laying/fixing of cable complete all as specified and directed by Engineer-in-Charge.
S&F syntex street light box with 3 phase aluminium bus bar including 6 Amps SP MCB with mounting /fixing acessories complete all as specified and directed by Enginer-in-charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 16 to 35 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 70 to 95 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ XLPE, armoured, Al conductor cable of size 150 to 185 sqmm,Outdoor type complete all as specified and directed by Engineer-in-Charge.
M&L danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15 cm size all as specified and directed by Engineer-in-Charge.
M&L, rewinding motor 5 HP - 7.5 HP 1400 RPM operating on 415 Volts, 3 phase 50 H AC supply for powering multi stage booster pump. The scope of work include dismantling of motor, cutting and removing the burnt winding cleaning the slots, rewinding with same size and turns of super enameled copper wire, taking out connections, tapping, varnishing backing and reassembling including replacement of UNSV parts such as nuts, bolts & washer etc inclduing testing on load complete all as specified and directed by Engineer-in-Charge.
Taking down old GI pipes 20 mm to 50 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix steel water tubing 40mm dia bore. medium grade galvanized including all fitting such as tees, bends, elbows redness, unions, clamps etc ISI marked laid in trench complete all as specified and directed by Engr-in-Charge.
Supply and fix steel water tubing 20 mm dia bore. medium grade galvanized including all fitting such as tees, bends, elbows redness, unions, clamps etc ISI marked laid in trench complete all as specified and directed by Engr-in-Charge.
Supply and fixing Gun metal gate valves 50 mm dia bore. ISI marked cast copper alloy screwed down high pressure with crutch or butter handle screwed both ends for Iron pipe or union and fixed complete as specified and directed by Engineer -in-Cahrge.
Supply and fixing Gun metal gate valves 20 mm dia bore. ISI marked cast copper alloy screwed down high pressure with crutch or butter handle screwed both ends for Iron pipe or union and fixed complete as specified and directed by Engineer -in-Charge.
Repair maintainance of HT VCB panel, detection of defective components, replacement of worn out parts and servicing/ cleaning of mechanical components, by the representative of authorized service contre of VCB Mfr's, Re insertion of trolly in HT panel, including calibration test ,relay test and testing for smooth operationcomplete all as specified and directed by Engineer-in-Charge. Note:- Worn out parts shall be measured & paid separately as supply only under relevant items
M&L for bringing cable Fault locator at site for locating the fault in Exixing 11000 Volts HT cable complete all as specified and directed by Engineer-in-Charge.
M&L for cable jinting kit for 11 KV (Earthed) grade cable for straight through heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 Sqmm complete all as specified and directed by Engineer-in-Charge.
M&L for cable jinting kit for 11 KV (Earthed) grade cable for indoor termination heat shrinkable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosures DB Double door Verticle distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge. Note : - MCCB shall be measured and paid separately
S&F sheet metal enclosures DB Double door distribution type, 04 way, TPN DB , IP43, 415V & suitable for 4 POLE MCB as incomming including shruded neutral bar & Pan assy with earthing terminal as provided by manufacturer complete all as specified and directed by Engineer-in-Charge. Note : - 4 pole MCB shall be measured and paid separately
S&F in replacement of MCCB TPN 125 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB TPN 100 Amps 415 Volts 16 KA as per suitable sample of size complete all as specified and directed by Engineer-in-Charge.
S/Fix in replacement MCB DB SPN 8 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one and complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 63Amps 16KA complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 160 Amps 4 pole 25 KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 200 Amps 4 pole 36 KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 250 Amps 4 pole 36 KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCCB 315 Amps 4 pole 36 KA 415 volts complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement of MCB SP 6 t0 32 amps 230 Volt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB TPN 40 amps 415 Volt complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB 4 pole 63 Amps 415 Volt complete all as specified and directed by Engineer-in-Charge.
M&L for carefully dismantling Split AC of 2 TR and shifting and re-installation of existing split AC after servicing complete all as specified and as directed by Engineer-in-Charge
Repair , servicing & preventive maintenance of split type AC's of capacity 1.5 TR comprising of the following tasks installed at different locations including refixing, commissioning and testing complete all as specified and directed by Engr-in-charge.
M/L charging of refrigerant to refrigerator up to required capacity as per site condition complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of starting capacitor 80-100/100-120 mfd for split type A/C's of capacity 1.5TR complete all as specified and directed by Engineer-in-Charge. Make-Telsa or ISI Marked.
S/F in replacement of running capacitor 30/36 mfd for split type AC unit as required at Site and as directed by Engineer-in-Charge.
Taking down desert cooler of any size by disconnecting electrical supply, cleaning, oiling of all moving part of pump & exhaust fan/kit, Replacing PVC pipes, nozzles, distributors, pads, checking electrical connections complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of wood pads(set of three)as per sample all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement the new desert cooler pump including testing for proper functioning all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement the new fan 450mm sweep for desert cooler all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement new body of desert cooler as per sample duly painted of 20 SWG sheet with 22 SWG flops, front grill, PVC pipe, nozzle, distributor and nut bolts washers for fixing fan clamps, complete all as specified and directed by Engineer-in-Charge.
Taking down and rewinding of fan 400mm of desert cooler with super enameled copper winding wire including replacement of bush complete all as specified and directed by Engineer-in-Charge.
Supply and fixing front grill PVC of desert cooler as per sample complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement plug top 15 Amps all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC flexible copper wire 3 core of size 4 Sqmm complete all as specified and directed by Engineer-in-Charge.
S&F ceiling fan 1200mm sweep 5 star rated complete with all accesories with canopy set,down rod and flexible cable from cealing rose to fan complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan of any sweep from existing place and repair/replacement of UNSV items all as specified and directed by Engr-In-Charge. Spare parts will be measured and paid separately.
M&L in replacement of defective shaft of ceiling fans including matching work for any make as per sample complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of ball bearing for fans of various size complete all as specified and directed by Engineer-in-Charge.
Supply and fixing and connecting flexible copper twisted twin core of size 23/.00076 complete all as specified and directed by Engineer-in-Charge.
M&L for painting of Ceiling Fan of size 1200mm” size complete in size with supper enameled synthetic paint by spraying including fitting cavities etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor 2.00 Mfd. in replacement of old unsv item complete all as specified and directed by Engineer-in-Charge.
Supply and fixing capacitor 2.5 Mfd. in replacement of old unsv item complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of ceiling fan of any sweep with supper enameled coper wire of suitable size of any make/type/model including transportation and old material to be deposited in stores complete all as specified and directed by Engineer-in-Charge
Taking down exhaust fans of any size as per details given below and cleaning the dust properly. Oiling, greasing of ball and bearing including re-fixing and connecting of all as specified and directed by Enginer-in-Charge.
M&L for rewinding of exhaust fan 250 mm to 300 mm sweep with supper enameled coper wire of suitable size of any make/type/model including transportation and old material to be deposited in stores complete all as specified and directed by Engineer-in-Charge :-
Supply and fix in replacement of ball bearing of exhaust fan of any size complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan sweep 250 mm in replacement made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
Supply and fix exhaust fan sweep 300 mm in replacement metallic type complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
Supply installation,testing and commissioning of abs Plastic body water heater 25 Ltrs thermal cutout including 02 Nos PVC pipe complete all as specified and directed by Engineer-in-Charge.
Taking down carefully water heater (Geyser) any capacity any make after removing electric & water connections from existing system for carrying out repairs(Repairs will be measured and paid separately) and refixing the same after carrying out necessary repairs to original place complete all as specified and directed by Engineer-in-Charge.
Removing existing hot & cold water copper/PVC flexible pipe connection from geyser and S&F new brass chromium plated water connection pipe with brass nut and washers of good quality about 45cm long in hot & cold water connections and connecting complete all as specified and directed by Engineer-in-Charge.
Replacement of heating element 1.5 kW for 35ltrs capacity geyser complete all as specified and directed by Engineer-in-Charge.
Replacement of thermo static switch of geyser complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Fancy type Bib tap of cast copper alloy with crutch screwed down, screwed for iron pipe of 15mm bore complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch screwed both ends for iron pipe or for unions of dia 15mm complete all as specified and directed by Engineer-in-Charge.
Cutting/drilling or taping from existing 15 or 20mm dia G I pipe in position for branch connection of 15mm dia including suitable fitting/fixtures complete all as specified and directed by Engineer-in-Charge.
Replacement of apparatus plate with nut, bolts, clamps, washer, etc. of geyser suitable for Record/Ditz make or any other make and any capacity including PRV & NRV system.
Welding with new brass studs for holding of heating element with replacement of suitable element holding clamps-3 nos. complete all as specified and directed by Engineer-in-Charge.
Replacement of indicating bulb of geyser complete all as specified and directed by Engineer-in-Charge.
S&F in repairs apparatus plate bottom cover in two halves made out of GI sheet duly painted all as directed by Engineer-in-Charge.
S&F water heater outer cover suitable for 25ltrs. Capacity of existing make including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
S& F geyser assembly including gasket and nuts and bolts complete with fixing arrangement all as specified and directed by Engineer - in- charge
S&F in replacement of water storage tank of suitable for 25ltrs capacity incl glass wool complete all as specified and directed by Engineer-in-Charge.
M& L for taking down and refixing light, fan, socket, bell or power point of any type and rating on any surface all as specified and as directed by Engineer-in-Charge.
Taking down and refixing pressure pump motor of capacity upto 1 HP, single phase , 230 Volt all as per specified and as directed by Engineer-in-Charge.
S&F single pole blanking plate in the existing cover plate complete as required complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Casing capping double lock type supper quality size 15 mm width ISI marked with fixing accessories complete all as specified and directed by Engineer-in-Charge.
Supply and installation of PVC Duct 100 mm width For AC copper pipes and insulation complete all as specified and directed by Engineer-in-Charge.
S&F street light GI pipe bracket 50 mm dia 1.50metre length (ISI marked) light grade bend to shape with two Nos MS clamp duly painted nuts and bolts etc complete all as specified and directed by Engineer-in-Charge. Note :Brackets to be installed / grouted on wall or pole upto 11 mtr height.
M&L for scrapping of surface of steel tubular poles of any size with emery paper and painting of pole one coat of primer and two coats of silver colour paint including writing pole No on yellow colour with 30cm strip upto 1.5 Mtr height from ground level complete all as specified and directed by Engineer-in-Charge.
Supply and filling transformer oil with breaking capacity 45 KV testing on load complete all as specified and directed by Engineer-in-Charge.
Dehyderation and filteration in cycles of transformer oil upto breaking capacity 45 KV is achieved and testing on load complete all as specified and directed by Engineer-in-Charge.
M&L for earthing with galvanised steel plate electrode 60cmx60cmx6mm thick buried directly in ground (Earth pit not less than 2.25mtr deep from ground level) surrounded from all directions with charcoal dust, salt and edge of earth plate not less than 1.5 mtr below ground level connected to galvanised iron strip 32mmx6mm earth lead by means of nuts, bolts and washers incl excavation and earth work PCC chamber and RCC cover of 1:2:4 type B-1 using XPM weighing not less than 4 Kg/Sqmm using 20mm graded stone aggregate for coping/under covers, 20mm size GI pipe light grade for watering funnel wire mesh etc, complete all as specified and shown in electrical plate No-03 of SSR Part-I complete all as specified and directed by Engineer-in-Charge.
Akhil Enterprises
GAR CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .