Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹20.1 L+₹7.2 L (56.3%)Rejected-Finance RANGIYA DIST KAMRUP ASSAM 781365 | BAKSA | ASSAM | 781365 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹23.7 L+₹10.8 L (84.1%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L3 | Rejected-Finance Unsuccessful bidder |
Tender Value
Refer Docs
EMD Value
₹52,400
Closing Date
28 Oct 2020, 6:00 pmClosed
CWE Tezpur
HQ CWE Tezpur Post Dekargaon Dist Sonitpur (Assam) PIN 784501
CONVERSION OF OH CONDUCTOR TO LT UG CABLE AND ALLIED WORKS FROM TCP NO 1 TO TCP NO 2 AT HATTIGOR MIL STN UNDER GE RANGIYA
2020_MES_382292_1
CWE/TEZ(R)/T-33 of 20-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Rangiya
as per tender docus
8 documents required · 8 mandatory
₹500
GE Rangiya
₹52,400
Yes
4 Nov 2020
30 Sept 2020
30 Oct 2020
30 Sept 2020
28 Oct 2020
14 Oct 2020
Amount
Dismantling of LT over head ACSR conductor of any size and removing from site complete all as specified and directed.
Dismantling of LT insulators of any type and size from positionand removing from site complete all as specified and directed.
Dismantling of cross arms fixed on Steel tubular poles carefully and removing from site complete all as specified and directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as specified and directed.
Dismantling of old tubular pole/ RCC of any size with necessary disconnection of electric wire, demolition of concrete foundation and removing the same from site complete all as specified and directed. Note : (Dismantling of cross arms and insulators fixed with pole shall be measured and paid separately under relevant items here-in-before).
Disconnecting the existing service connections of any size and removing from site complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core including end termination joint complete all as specified and directed.
All as per item No 07 above but of 95 Sqmm, 3.5 Core
All as per item No. 07 above but of 70 Sqmm, 3.5 Core
All as per item No. 07 above but of 50 Sqmm, 3.5 Core
All as per item No. 07 above but of 16 Sqmm, 4 Core
Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 630 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., to accomodate the following items including supply and fix following items :- (a) MCCB 4 pole 400 Amps with breaking capacity 35 KA adjustable type with extended terminals - 01 No.[Incoming]. (b) Outgoing MCCB, 4 pole of capacity 200 amps with breaking capacity of 25 KA . - 2 No (c) Outgoing MCCB, 4 pole of capacity 160 amps with breaking capacity of 25 KA . - 1 No (d) Outgoing MCCB of 4 pole of capacity 125 amps with breaking capacity of 25 KA . - 2 No (e) Electronic energy meter three phase panel mounting type with LCD display 96mm x 96mm flush mounted case class 1.0 accuracy 3x240 volts AC supply 200/5 Amp LT CT operated programable upto 6000 amps primary current with Rs 485 - 01 No Note : The feeders of each control may be marked location with fluorescent paint.
Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, factory made powder coated as approved colour, aluminum bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 800 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers to accomodate the following items including supply and fix following items :- (a) MCCB, 4 pole of capacity 630 amps with breaking capacity of 50 KA. - 01 No. (Main Incomer) (b) Electronic energy meter three phase panel mounting type with LCD display 96mm x 96mm flush mounted case class 1.0 accuracy 3x240 volts AC supply 200/5 Amp LT CT operated programable upto 6000 amps primary current with Rs 485 - 01 No Note : The feeders of each control may be marked location with fluorescent paint.
M&L for equipment earthing complete incl necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to galvanised earth strip 32x6 mm by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.5 of MES SSR Part-1 connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanised iron 40 mm dia. light grade pipe and watering pipe shall be 20 mm ore medium grade PCC pipt with pre cast RCC cover, charcoal/salt funnel etc. complete all as directed. Note : The conctrete pit shall be PCC 1:3:6 tye C -1 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 8 mm TMT bars @10 cm C/C on both sides with suitable cast iron handle shall be provided in liew of cast iron cover shown in electrical plate No.5 of MES SSR Part-1 (ii) Item includes the cost of 7.5 m GI pipe for protectio of earth strip. (iii) PCC pits shall be provided atleast 500 mm away from the pit and not on the earth pipt itself and the extra cost of additional length of watering pipe, bends , elbows etc. shall be deemed to be included in the quioted rate. (iv) Item includes the cost of 7.5 mtr length earth strip.
S&F of thermoplastic polycarbonate cable terminal box, IP 66 protection, screw cover top type, suitable for 16 sqmm, 4 core cable, 3P+N incoming/outgoing cable and P+N PVC sheathed connection cable for light fitting, having DIN rail mounting arrangement for holding SPN MCB, with and including SPN MCB 10 Amp, cable junction terminals, IP 55 cable glands of sutable size for cable entry/out and 02 nos of MS clamps and 04 nos of mounting brackets, including all fixing accessories etc, complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter depth for foundation of pole etc and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm in soft/loose soil after the pipes/fittings are laid/fixed jointed and tested complete all as specified and directed.
Removing excavated material from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5 mtr from the starting point complete all as specified and directed.
Material and labour for sand cushisioning to under ground cable with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable (total 230 mm in trenches complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the IRC specifications shall be followed. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule "A" notes for details.
M/S NARAYAN ENTERPRISE
M/S S.S. Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .